{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,9]],"date-time":"2026-11-09T22:23:18Z","timestamp":1794262998890,"version":"4.9.0"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2024,2,5]],"date-time":"2024-02-05T00:00:00Z","timestamp":1707091200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,2,5]],"date-time":"2024-02-05T00:00:00Z","timestamp":1707091200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001801","name":"University of Western Australia","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100001801","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Phys Eng Sci Med"],"published-print":{"date-parts":[[2024,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Paediatric imaging protocols should be carefully optimised to maintain the desired image quality while minimising the delivered patient dose. A paediatric chest phantom was designed, constructed and evaluated to optimise chest CT examinations for infants. The phantom was designed to enable dosimetry and image quality measurements within the anthropomorphic structure. It was constructed using tissue equivalent materials to mimic thoracic structures of infants, aged 0\u20136\u00a0months. The phantom materials were validated across a range of diagnostic tube voltages with resulting CT numbers found equivalent to paediatric tissues observed via a survey of clinical paediatric chest studies. The phantom has been successfully used to measure radiation dose and evaluate various image quality parameters for paediatric specific protocols.<\/jats:p>","DOI":"10.1007\/s13246-023-01379-5","type":"journal-article","created":{"date-parts":[[2024,2,5]],"date-time":"2024-02-05T07:03:23Z","timestamp":1707116603000},"page":"491-501","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Construction and validation of an infant chest phantom for paediatric computed tomography"],"prefix":"10.1007","volume":"47","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5661-8462","authenticated-orcid":false,"given":"Seonaid","family":"Rodgers","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0188-367X","authenticated-orcid":false,"given":"Janette","family":"Atkinson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Cryer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3337-3239","authenticated-orcid":false,"given":"Cameron","family":"Storm","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1473-1379","authenticated-orcid":false,"given":"Rikki","family":"Nezich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6875-0719","authenticated-orcid":false,"given":"Martin A.","family":"Ebert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8306-7742","authenticated-orcid":false,"given":"Pejman","family":"Rowshanfarzad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,2,5]]},"reference":[{"key":"1379_CR1","doi-asserted-by":"publisher","unstructured":"Radiation, Committee & Research, Board & Studies, Division & Council, National (2006) Health risks from exposure to low levels of ionizing radiation: BEIR VII Phase 2. https:\/\/doi.org\/10.17226\/11340","DOI":"10.17226\/11340"},{"issue":"2","key":"1379_CR2","doi-asserted-by":"publisher","first-page":"289","DOI":"10.2214\/ajr.176.2.1760289","volume":"176","author":"DJ Brenner","year":"2001","unstructured":"Brenner DJ, Elliston CD, Hall EJ, Berdon WE (2001) Estimated risks of radiation-induced fatal cancer from pediatric CT. Am J Roentgenol 176(2):289\u2013296","journal-title":"Am J Roentgenol"},{"issue":"2","key":"1379_CR3","doi-asserted-by":"publisher","first-page":"95","DOI":"10.5694\/mja11.11124","volume":"197","author":"Z Brady","year":"2012","unstructured":"Brady Z, Cain T, Johnston PN (2012) Justifying referrals for paediatric CT. Med J Aust 197(2):95\u201399","journal-title":"Med J Aust"},{"issue":"2","key":"1379_CR4","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1148\/rg.262055138","volume":"26","author":"CH McCollough","year":"2006","unstructured":"McCollough CH, Bruesewitz MR, Kofler JM Jr (2006) CT dose reduction and dose management tools: overview of available options. Radiographics 26(2):503\u2013512","journal-title":"Radiographics"},{"key":"1379_CR5","unstructured":"Woods M, Brehm M (2022) Shaping the beam"},{"issue":"9","key":"1379_CR6","doi-asserted-by":"publisher","first-page":"3274","DOI":"10.1118\/1.2256686","volume":"33","author":"AK Jones","year":"2006","unstructured":"Jones, A. K., Simon, T. A., Bolch, W. E., Holman, M. M., & Hintenlang, D. E. (2006). Tomographic physical phantom of the newborn child with real-time dosimetry I. Methods and techniques for construction. Med Phys 33(9):3274\u20133282","journal-title":"Med Phys"},{"key":"1379_CR7","first-page":"185","volume":"87","author":"SW Alderson","year":"1962","unstructured":"Alderson SW, Lanzl LH (1962) An instrumented phantom system for analog computation of treatment plan. Am J Roentgenol Radium Ther Nucl Med 87:185\u2013195","journal-title":"Am J Roentgenol Radium Ther Nucl Med"},{"key":"1379_CR8","unstructured":"Computerized Imaging Reference Systems (CIRS) Inc (2022) ATOM phantom family, model 701-706. https:\/\/www.cirsinc.com\/products\/radiation-therapy\/atom-phantom-family\/. Accessed June 2022"},{"key":"1379_CR9","doi-asserted-by":"publisher","DOI":"10.1155\/2018\/3835810","author":"N Kasraie","year":"2018","unstructured":"Kasraie N, Robinson A, Chan S (2018) Construction of an anthropomorphic phantom for use in evaluating pediatric airway digital tomosynthesis protocols. Radiol Res Pract. https:\/\/doi.org\/10.1155\/2018\/3835810","journal-title":"Radiol Res Pract"},{"key":"1379_CR10","doi-asserted-by":"publisher","DOI":"10.1016\/j.radphyschem.2019.108472","volume":"166","author":"NH Jamal","year":"2020","unstructured":"Jamal NH, Sayed IS, Syed WS (2020) Estimation of organ absorbed dose in pediatric chest X-ray examination: a phantom study. Radiat Phys Chem 166:108472. https:\/\/doi.org\/10.1016\/j.radphyschem.2019.108472","journal-title":"Radiat Phys Chem"},{"key":"1379_CR11","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1016\/j.ejrad.2018.09.015","volume":"108","author":"AM Ali","year":"2018","unstructured":"Ali AM, Hogg P, Johansen S, England A (2018) Construction and validation of a low cost paediatric pelvis phantom. Eur J Radiol 108:84\u201391","journal-title":"Eur J Radiol"},{"issue":"1","key":"1379_CR12","doi-asserted-by":"publisher","first-page":"94","DOI":"10.21037\/qims.2018.08.01","volume":"9","author":"F Zhang","year":"2019","unstructured":"Zhang F, Zhang H, Zhao H, He Z, Shi L, He Y et al (2019) Design and fabrication of a personalized anthropomorphic phantom using 3D printing and tissue equivalent materials. Quant Imaging Med Surg 9(1):94","journal-title":"Quant Imaging Med Surg"},{"key":"1379_CR13","unstructured":"True phantom solutions, pediatric full human body phantom for X-ray CT & MRI training. https:\/\/www.truephantom.com\/product\/pediatric-full-human-body-phantom-for-x-ray-ct-mri-training. Accessed June 2022"},{"key":"1379_CR14","unstructured":"Kyoto Kagaku (2022) Newborn wholebody phantom \u201cPBU-80\u201d https:\/\/www.kyotokagaku.com\/en\/products_data\/ph-50b\/. Accessed June 2022"},{"key":"1379_CR15","unstructured":"Computerized Imaging Reference Systems (CIRS) Inc (2022) Pediatric anthropomorphic training phantoms, model 715 series. https:\/\/www.cirsinc.com\/products\/x-ray-fluoro\/pediatric-anthropomorphic-training-phantoms\/. Accessed June 2022"},{"key":"1379_CR16","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1186\/s13014-022-02123-1","volume":"17","author":"TJ Klein","year":"2022","unstructured":"Klein TJ, Gill S, Ebert MA, Grogan G, Smith W, Alkhatib Z, Geraghty J, Scott AJD, Brown A, Rowshanfarzad P (2022) CyberKnife Xsight versus fiducial-based target-tracking: a novel 3D dosimetric comparison in a dynamic phantom. Radiat Oncol 17:154. https:\/\/doi.org\/10.1186\/s13014-022-02123-1","journal-title":"Radiat Oncol"},{"key":"1379_CR17","unstructured":"ICRU, Tissue Substitutes in Radiation Dosimetry and Measurement, ICRU Report 44 (International Commission on Radiation Units and Measurements, Bethesda, MD, 1989)"},{"key":"1379_CR18","unstructured":"American Association of Physicists in Medicine (2011) Size specific dose estimates (SSDE) in pediatric and adult body CT examinations. Technical report, AAPM"},{"issue":"9","key":"1379_CR19","doi-asserted-by":"publisher","first-page":"168","DOI":"10.21833\/ijaas.2017.09.024","volume":"4","author":"M Alssabbagh","year":"2017","unstructured":"Alssabbagh M, Tajuddin AA, MbA M, Zainon R (2017) Evaluation of nine 3D printing materials as tissue equivalent materials in terms of mass attenuation coefficient and mass density. Int J Adv Appl Sci 4(9):168-173J","journal-title":"Int J Adv Appl Sci"},{"key":"1379_CR20","doi-asserted-by":"publisher","first-page":"P09018","DOI":"10.1088\/1748-0221\/13\/09\/P09018","volume":"13","author":"J \u0160olc","year":"2018","unstructured":"\u0160olc J, Vrba T, Burianova L (2018) Tissue-equivalence of 3D-printed plastics for medical phantoms in radiology. J Instrum 13:P09018\u2013P09018. https:\/\/doi.org\/10.1088\/1748-0221\/13\/09\/P09018","journal-title":"J Instrum"},{"issue":"4","key":"1379_CR21","doi-asserted-by":"publisher","first-page":"1433","DOI":"10.1007\/s13246-020-00944-6","volume":"43","author":"S Muir","year":"2020","unstructured":"Muir S, Laban J (2020) A phantom for testing cone beam CTs. Phys Eng Sci Med 43(4):1433\u20131440","journal-title":"Phys Eng Sci Med"}],"container-title":["Physical and Engineering Sciences in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-023-01379-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s13246-023-01379-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-023-01379-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,11]],"date-time":"2024-06-11T05:54:23Z","timestamp":1718085263000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s13246-023-01379-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,5]]},"references-count":21,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,6]]}},"alternative-id":["1379"],"URL":"https:\/\/doi.org\/10.1007\/s13246-023-01379-5","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-2253613\/v1","asserted-by":"object"}]},"ISSN":["2662-4729","2662-4737"],"issn-type":[{"value":"2662-4729","type":"print"},{"value":"2662-4737","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,5]]},"assertion":[{"value":"13 November 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 December 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 February 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This research was supported by the University of Western Australia, Medical Physics Research Group and the Medical Imaging Department at Perth Children\u2019s Hospital, WA. The phantom was constructed in the department of Medical Technology and Physics, Sir Charles Gairdner Hospital and belongs to WA Health. The authors have no financial or proprietary interests in any material discussed in this article.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}