{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T15:16:25Z","timestamp":1774451785056,"version":"3.50.1"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2024,2,19]],"date-time":"2024-02-19T00:00:00Z","timestamp":1708300800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,2,19]],"date-time":"2024-02-19T00:00:00Z","timestamp":1708300800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"JSPS KAKENHI","award":["JP23K07063"],"award-info":[{"award-number":["JP23K07063"]}]},{"DOI":"10.13039\/501100012330","name":"Okayama University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100012330","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Phys Eng Sci Med"],"published-print":{"date-parts":[[2024,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>To investigate the impact of sagging correction calibration errors in radiotherapy software on image matching. Three software applications were used, with and without a polymethyl methacrylate rod supporting the ball bearings (BB). The calibration error for sagging correction across nine flex maps (FMs) was determined by shifting the BB positions along the Left\u2013Right (LR), Gun\u2013Target (GT), and Up\u2013Down (UD) directions from the reference point. Lucy and pelvic phantom cone-beam computed tomography (CBCT) images underwent auto-matching after modifying each FM. Image deformation was assessed in orthogonal CBCT planes, and the correlations among BB shift magnitude, deformation vector value, and differences in auto-matching were analyzed. The average difference in analysis results among the three softwares for the Winston\u2013Lutz test was within 0.1\u00a0mm. The determination coefficients (R<jats:sup>2<\/jats:sup>) between the BB shift amount and Lucy phantom matching error in each FM were 0.99, 0.99, and 1.00 in the LR-, GT-, and UD-directions, respectively. The pelvis phantom demonstrated no cross-correlation in the GT direction during auto-matching error evaluation using each FM. The correlation coefficient (r) between the BB shift and the deformation vector value was 0.95 on average for all image planes. Slight differences were observed among software in the evaluation of the Winston\u2013Lutz test. The sagging correction calibration error in the radiotherapy imaging system was caused by an auto-matching error of the phantom and deformation of CBCT images.<\/jats:p>","DOI":"10.1007\/s13246-024-01388-y","type":"journal-article","created":{"date-parts":[[2024,2,19]],"date-time":"2024-02-19T11:03:24Z","timestamp":1708340604000},"page":"589-596","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Evaluation of the effect of sagging correction calibration errors in radiotherapy software on image matching"],"prefix":"10.1007","volume":"47","author":[{"given":"Yumi","family":"Yamazawa","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akitane","family":"Osaka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasushi","family":"Fujii","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takahiro","family":"Nakayama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kunio","family":"Nishioka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7259-3317","authenticated-orcid":false,"given":"Yoshinori","family":"Tanabe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,2,19]]},"reference":[{"issue":"9Part1","key":"1388_CR1","doi-asserted-by":"publisher","first-page":"4197","DOI":"10.1118\/1.3190392","volume":"36","author":"EE Klein","year":"2009","unstructured":"Klein EE, Hanley J, Bayouth J et al\u00a0(2009) Task Group 142 report: quality assurance of medical accelerators a. Med Phys\u00a036(9Part1):4197\u20134212.\u00a0https:\/\/doi.org\/10.1118\/1.3190392","journal-title":"Med Phys"},{"issue":"4","key":"1388_CR2","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1120\/jacmp.v12i4.3645","volume":"12","author":"P Rowshanfarzad","year":"2011","unstructured":"Rowshanfarzad P, Sabet M, O\u2019Connor DJ, Greer PB (2011) Isocenter verification for linac-based stereotactic radiation therapy: review of principles and techniques. J Appl Clin Med Phys 12(4):185\u2013195. https:\/\/doi.org\/10.1120\/jacmp.v12i4.3645","journal-title":"J Appl Clin Med Phys"},{"issue":"3","key":"1388_CR3","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1002\/acm2.12064","volume":"18","author":"MP Barnes","year":"2017","unstructured":"Barnes MP, Greer PB (2017) Evaluation of the truebeam machine performance check (MPC) geometric checks for daily IGRT geometric accuracy quality assurance. J Appl Clin Med Phys 18(3):200\u2013206. https:\/\/doi.org\/10.1002\/acm2.12064","journal-title":"J Appl Clin Med Phys"},{"issue":"3","key":"1388_CR4","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1007\/s13246-016-0463-9","volume":"39","author":"PB Ravindran","year":"2017","unstructured":"Ravindran PB (2016) A study of Winston\u2013Lutz test on two different electronic portal imaging devices and with low energy imaging. Aust Phys Eng Sci Med 39(3):677\u2013685. https:\/\/doi.org\/10.1007\/s13246-016-0463-9","journal-title":"Aust Phys Eng Sci Med"},{"issue":"4","key":"1388_CR5","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1120\/jacmp.v11i4.3297","volume":"11","author":"W Du","year":"2010","unstructured":"Du W, Yang JN, Chang EL, Luo D, McAleer MF, Shiu A, Martel MK (2010) A quality assurance procedure to evaluate cone-beam CT image center congruence with the radiation isocenter of a linear accelerator. J Appl Clin Med Phys 11(4):15\u201326. https:\/\/doi.org\/10.1120\/jacmp.v11i4.3297","journal-title":"J Appl Clin Med Phys"},{"issue":"6","key":"1388_CR6","doi-asserted-by":"publisher","first-page":"314","DOI":"10.1120\/jacmp.v16i6.5733","volume":"16","author":"Y Zhang","year":"2015","unstructured":"Zhang Y, Ding K, Cowan G, Tryggestad E, Armour E, Wang KKH (2015) Alignment of multiradiation isocenters for megavoltage photon beam. J Appl Clin Med Phys 16(6):314\u2013324. https:\/\/doi.org\/10.1120\/jacmp.v16i6.5733","journal-title":"J Appl Clin Med Phys"},{"key":"1388_CR7","doi-asserted-by":"publisher","unstructured":"Chojnowski JM, Warr GB, Sykes JR et al (2020) Assessment of error in the MV radiation isocenter position calculated with the Elekta XVI software. J Appl Clin Med Phys 21(5):93\u201397. https:\/\/doi.org\/10.1002\/acm2.12861","DOI":"10.1002\/acm2.12861"},{"key":"1388_CR8","unstructured":"Hand C, Fitzherbert C (2022) The utilization of the machine performance check application on a varian truebeam as a substitute for performing the Winston\u2013Lutz test for stereotactic radiotherapy treatments. Cureus J Med Sci 14(2)"},{"key":"1388_CR9","doi-asserted-by":"publisher","unstructured":"Norvill C, Bockelmann F, Blumenberg P et al (2021)  Investigation of Elekta AQUA software for kilovoltage to megavoltage radiation isocenter coincidence. Phys Eng Sci Med 44(3):667\u2013675. https:\/\/doi.org\/10.1007\/s13246-021-01014-1","DOI":"10.1007\/s13246-021-01014-1"},{"issue":"32","key":"1388_CR10","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/j.ejmp.2016.01.131","volume":"2016","author":"I L\u00f8vik","year":"2016","unstructured":"L\u00f8vik I, Anoja A, Canino S, Cristofaro A et al (2016) Verification of a port film graticule for daily quality assurance. Physica Medica Eur J Med Phys 2016(32):37\u201338. https:\/\/doi.org\/10.1016\/j.ejmp.2016.01.131","journal-title":"Physica Medica Eur J Med Phys"},{"issue":"2","key":"1388_CR11","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13501","volume":"23","author":"A Karius","year":"2022","unstructured":"Karius A, Karolczak M, Strnad V, Bert C (2022) Technical evaluation of the cone-beam computed tomography imaging performance of a novel, mobile, gantry-based X-ray system for brachytherapy. J Appl Clin Med Phys 23(2):e13501. https:\/\/doi.org\/10.1002\/acm2.13501","journal-title":"J Appl Clin Med Phys"},{"issue":"3","key":"1388_CR12","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1120\/jacmp.v15i3.4688","volume":"15","author":"S Gao","year":"2014","unstructured":"Gao S, Du W, Balter P, Munro P, Jeung A (2014) Evaluation of IsoCal geometric calibration system for Varian linacs equipped with on-board imager and electronic portal imaging device imaging systems. J Appl Clin Med Phys 15(3):164\u2013181. https:\/\/doi.org\/10.1120\/jacmp.v15i3.4688","journal-title":"J Appl Clin Med Phys"},{"issue":"4","key":"1388_CR13","doi-asserted-by":"publisher","first-page":"e39","DOI":"10.1120\/jacmp.v15i3.4688","volume":"44","author":"Y Tanabe","year":"2019","unstructured":"Tanabe Y, Ishida T, Eto H, Sera T, Emoto Y (2019) Evaluation of the correlation between prostatic displacement and rectal deformation using the Dice similarity coefficient of the rectum. Med Dosim 44(4):e39\u2013e43. https:\/\/doi.org\/10.1120\/jacmp.v15i3.4688","journal-title":"Med Dosim"},{"key":"1388_CR14","doi-asserted-by":"publisher","unstructured":"Tanabe Y, Ishida T (2021) Development of a novel detection method for changes in lung conditions during radiotherapy using a temporal subtraction technique. Phys Eng Sci Med 44:1341\u20131350. https:\/\/doi.org\/10.1007\/s13246-021-01070-7","DOI":"10.1007\/s13246-021-01070-7"},{"key":"1388_CR15","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1016\/j.phro.2022.10.001","volume":"24","author":"Y Tanabe","year":"2022","unstructured":"Tanabe Y, Tanaka H (2022) Statistical evaluation of the effectiveness of dual amplitude-gated stereotactic body radiotherapy using fiducial markers and lung volume. Phys Imaging Radiat Oncol 24:82\u201387. https:\/\/doi.org\/10.1016\/j.phro.2022.10.001","journal-title":"Phys Imaging Radiat Oncol"},{"issue":"2","key":"1388_CR16","doi-asserted-by":"publisher","first-page":"85","DOI":"10.2478\/pjmpe-2023-0010","volume":"29","author":"S Imajo","year":"2023","unstructured":"Imajo S, Tanabe Y, Nakamura N, Honda M, Kuroda M (2023) Objective evaluation method using multiple image analyses for panoramic radiography improvement. Pol J Med Phys Eng 29(2):85\u201391. https:\/\/doi.org\/10.2478\/pjmpe-2023-0010","journal-title":"Pol J Med Phys Eng"},{"issue":"2","key":"1388_CR17","doi-asserted-by":"publisher","first-page":"154","DOI":"10.4236\/ijmpcero.2016.52017","volume":"5","author":"J Gao","year":"2016","unstructured":"Gao J, Liu X (2016) Off-isocenter Winston\u2013Lutz test for stereotactic radiosurgery\/stereotactic body radiotherapy. Int J Med Phys Clin Eng Radiat Oncol 5(2):154\u2013161. https:\/\/doi.org\/10.4236\/ijmpcero.2016.52017","journal-title":"Int J Med Phys Clin Eng Radiat Oncol"},{"issue":"9","key":"1388_CR18","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13665","volume":"23","author":"LM Pudsey","year":"2022","unstructured":"Pudsey LM, Biasi G, Ralston A, Rosenfeld A, Poder J (2022) Detection of rotational errors in single-isocenter multiple-target radiosurgery: is a routine off-axis Winston\u2013Lutz test necessary? J Appl Clin Med Phys 23(9):e13665. https:\/\/doi.org\/10.1002\/acm2.13665","journal-title":"J Appl Clin Med Phys"}],"container-title":["Physical and Engineering Sciences in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-024-01388-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s13246-024-01388-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-024-01388-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,11]],"date-time":"2024-06-11T09:55:27Z","timestamp":1718099727000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s13246-024-01388-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,19]]},"references-count":18,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,6]]}},"alternative-id":["1388"],"URL":"https:\/\/doi.org\/10.1007\/s13246-024-01388-y","relation":{},"ISSN":["2662-4729","2662-4737"],"issn-type":[{"value":"2662-4729","type":"print"},{"value":"2662-4737","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,19]]},"assertion":[{"value":"17 July 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 January 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 February 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}