{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T19:29:07Z","timestamp":1784230147139,"version":"3.55.0"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2025,3,3]],"date-time":"2025-03-03T00:00:00Z","timestamp":1740960000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,3,3]],"date-time":"2025-03-03T00:00:00Z","timestamp":1740960000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"Department of Science and Technology, (BDTD programme of YDT Division)","award":["TDP\/BDTD\/65\/2021\/General"],"award-info":[{"award-number":["TDP\/BDTD\/65\/2021\/General"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Phys Eng Sci Med"],"published-print":{"date-parts":[[2025,6]]},"DOI":"10.1007\/s13246-025-01529-x","type":"journal-article","created":{"date-parts":[[2025,3,3]],"date-time":"2025-03-03T06:53:44Z","timestamp":1740984824000},"page":"623-634","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Feasibility of the 3D printer to design an intracavitary applicator for the treatment of cervical cancer patients with high dose rate brachytherapy system"],"prefix":"10.1007","volume":"48","author":[{"given":"Ankur","family":"Mourya","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6699-9262","authenticated-orcid":false,"given":"Lalit","family":"Mohan Aggarwal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sunil","family":"Choudhary","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Neeraj","family":"Sharma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ritusha","family":"Mishra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chandra","family":"Prakash","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Uday","family":"Pratap Shahi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,3,3]]},"reference":[{"key":"1529_CR1","doi-asserted-by":"publisher","first-page":"567","DOI":"10.1016\/j.clon.2021.06.012","volume":"33","author":"CW Williamson","year":"2021","unstructured":"Williamson CW, Liu HC, Mayadev J, Mell LK (2021) Advances in external beam radiation therapy and brachytherapy for cervical cancer. Clin Oncol 33:567\u2013578. https:\/\/doi.org\/10.1016\/j.clon.2021.06.012","journal-title":"Clin Oncol"},{"key":"1529_CR2","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1016\/j.radonc.2011.07.012","volume":"100","author":"R P\u00f6tter","year":"2011","unstructured":"P\u00f6tter R, Georg P, Dimopoulos JCA et al (2011) Clinical outcome of protocol based image (MRI) guided adaptive brachytherapy combined with 3D conformal radiotherapy with or without chemotherapy in patients with locally advanced cervical cancer. Radiother Oncol 100:116\u2013123. https:\/\/doi.org\/10.1016\/j.radonc.2011.07.012","journal-title":"Radiother Oncol"},{"key":"1529_CR3","doi-asserted-by":"publisher","first-page":"1052","DOI":"10.1016\/j.ijrobp.2019.12.019","volume":"106","author":"M Serban","year":"2020","unstructured":"Serban M, Kirisits C, de Leeuw A et al (2020) Ring versus ovoids and intracavitary versus intracavitary-interstitial applicators in cervical cancer brachytherapy: results from the EMBRACE I study. Int J Radiat Oncol Biol Phys 106:1052\u20131062. https:\/\/doi.org\/10.1016\/j.ijrobp.2019.12.019","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"1529_CR4","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1016\/j.brachy.2009.08.014","volume":"9","author":"N Magn\u00e9","year":"2010","unstructured":"Magn\u00e9 N, Chargari C, SanFilippo N et al (2010) Technical aspects and perspectives of the vaginal mold applicator for brachytherapy of gynecologic malignancies. Brachytherapy 9:274\u2013277. https:\/\/doi.org\/10.1016\/j.brachy.2009.08.014","journal-title":"Brachytherapy"},{"key":"1529_CR5","doi-asserted-by":"publisher","first-page":"580","DOI":"10.1016\/j.brachy.2018.01.003","volume":"17","author":"S Otter","year":"2018","unstructured":"Otter S, Coates A, Franklin A et al (2018) Improving dose delivery by adding interstitial catheters to fixed geometry applicators in high-dose-rate brachytherapy for cervical cancer. Brachytherapy 17:580\u2013586. https:\/\/doi.org\/10.1016\/j.brachy.2018.01.003","journal-title":"Brachytherapy"},{"key":"1529_CR6","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1016\/j.ijrobp.2006.04.041","volume":"66","author":"JCA Dimopoulos","year":"2006","unstructured":"Dimopoulos JCA, Kirisits C, Petric P et al (2006) The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer: Clinical feasibility and preliminary results. Int J Radiat Oncol Biol Phys 66:83\u201390. https:\/\/doi.org\/10.1016\/j.ijrobp.2006.04.041","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"1529_CR7","doi-asserted-by":"publisher","first-page":"440","DOI":"10.1016\/j.ijrobp.2016.06.015","volume":"96","author":"DY Han","year":"2016","unstructured":"Han DY, Safigholi H, Soliman A et al (2016) Direction modulated brachytherapy for treatment of cervical cancer. II: comparative planning study with intracavitary and intracavitary-interstitial techniques. Int J Rad Oncol Biol Phys 96:440\u2013448. https:\/\/doi.org\/10.1016\/j.ijrobp.2016.06.015","journal-title":"Int J Rad Oncol Biol Phys"},{"key":"1529_CR8","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1002\/acm2.12657","volume":"20","author":"S Lozares-Cordero","year":"2019","unstructured":"Lozares-Cordero S, Font-G\u00f3mez JA, Gand\u00eda-Mart\u00ednez A et al (2019) Treatment of cervical cancer with electronic brachytherapy. J Appl Clin Med Phys 20:78\u201386. https:\/\/doi.org\/10.1002\/acm2.12657","journal-title":"J Appl Clin Med Phys"},{"key":"1529_CR9","doi-asserted-by":"publisher","first-page":"231","DOI":"10.4103\/jmp.jmp_62_21","volume":"46","author":"A Mourya","year":"2021","unstructured":"Mourya A, Aggarwal LM, Choudhary S (2021) Evolution of brachytherapy applicators for the treatment of cervical cancer. J Med Phys 46:231","journal-title":"J Med Phys"},{"key":"1529_CR10","doi-asserted-by":"publisher","first-page":"545","DOI":"10.1016\/j.promfg.2017.07.148","volume":"11","author":"UM Dilberoglu","year":"2017","unstructured":"Dilberoglu UM, Gharehpapagh B, Yaman U, Dolen M (2017) The role of additive manufacturing in the era of industry 4.0. Procedia Manuf 11:545\u2013554. https:\/\/doi.org\/10.1016\/j.promfg.2017.07.148","journal-title":"Procedia Manuf"},{"key":"1529_CR11","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1016\/j.compositesb.2018.02.012","volume":"143","author":"TD Ngo","year":"2018","unstructured":"Ngo TD, Kashani A, Imbalzano G et al (2018) Additive manufacturing (3D printing): a review of materials, methods, applications and challenges. Compos B Eng 143:172\u2013196. https:\/\/doi.org\/10.1016\/j.compositesb.2018.02.012","journal-title":"Compos B Eng"},{"key":"1529_CR12","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1016\/j.memsci.2017.05.037","volume":"537","author":"WS Tan","year":"2017","unstructured":"Tan WS, Suwarno SR, An J et al (2017) Comparison of solid, liquid and powder forms of 3D printing techniques in membrane spacer fabrication. J Memb Sci 537:283\u2013296. https:\/\/doi.org\/10.1016\/j.memsci.2017.05.037","journal-title":"J Memb Sci"},{"key":"1529_CR13","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1016\/j.actamat.2016.02.014","volume":"108","author":"SA Khairallah","year":"2016","unstructured":"Khairallah SA, Anderson AT, Rubenchik A, King WE (2016) Laser powder-bed fusion additive manufacturing: physics of complex melt flow and formation mechanisms of pores, spatter, and denudation zones. Acta Mater 108:36\u201345. https:\/\/doi.org\/10.1016\/j.actamat.2016.02.014","journal-title":"Acta Mater"},{"key":"1529_CR14","doi-asserted-by":"publisher","first-page":"033502","DOI":"10.1088\/1468-6996\/16\/3\/033502","volume":"16","author":"SFS Shirazi","year":"2015","unstructured":"Shirazi SFS, Gharehkhani S, Mehrali M et al (2015) A review on powder-based additive manufacturing for tissue engineering: selective laser sintering and inkjet 3D printing. Sci Technol Adv Mater 16:033502. https:\/\/doi.org\/10.1088\/1468-6996\/16\/3\/033502","journal-title":"Sci Technol Adv Mater"},{"key":"1529_CR15","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1002\/jor.23075","volume":"34","author":"SL Sing","year":"2016","unstructured":"Sing SL, An J, Yeong WY, Wiria FE (2016) Laser and electron-beam powder-bed additive manufacturing of metallic implants: a review on processes, materials and designs. J Orthop Res 34:369\u2013385. https:\/\/doi.org\/10.1002\/jor.23075","journal-title":"J Orthop Res"},{"key":"1529_CR16","doi-asserted-by":"publisher","first-page":"2406","DOI":"10.3390\/ma13102406","volume":"13","author":"Y Wang","year":"2020","unstructured":"Wang Y, Xu Z, Wu D, Bai J (2020) Current status and prospects of polymer powder 3D printing technologies. Materials 13:2406. https:\/\/doi.org\/10.3390\/ma13102406","journal-title":"Materials"},{"key":"1529_CR17","doi-asserted-by":"publisher","first-page":"100638","DOI":"10.1016\/J.PMATSCI.2020.100638","volume":"111","author":"H Wu","year":"2020","unstructured":"Wu H, Fahy WP, Kim S et al (2020) Recent developments in polymers\/polymer nanocomposites for additive manufacturing. Prog Mater Sci 111:100638. https:\/\/doi.org\/10.1016\/J.PMATSCI.2020.100638","journal-title":"Prog Mater Sci"},{"key":"1529_CR18","doi-asserted-by":"publisher","DOI":"10.1002\/ACM2.13773","author":"JL Robar","year":"2022","unstructured":"Robar JL, Kammerzell B, Hulick K et al (2022) Novel multi jet fusion 3D-printed patient immobilization for radiation therapy. J Appl Clin Med Phys. https:\/\/doi.org\/10.1002\/ACM2.13773","journal-title":"J Appl Clin Med Phys"},{"key":"1529_CR19","doi-asserted-by":"publisher","DOI":"10.1186\/S12938-021-00947-8","author":"C Amstutz","year":"2021","unstructured":"Amstutz C, Weisse B, Valet S et al (2021) Temperature-dependent tensile properties of polyamide 12 for the use in percutaneous transluminal coronary angioplasty balloon catheters. Biomed Eng Online. https:\/\/doi.org\/10.1186\/S12938-021-00947-8","journal-title":"Biomed Eng Online"},{"key":"1529_CR20","doi-asserted-by":"publisher","first-page":"1909","DOI":"10.1590\/1678-5150-pvb-5776","volume":"38","author":"RGG Dias","year":"2018","unstructured":"Dias RGG, Magalh\u00e3es GM, Dias LGGG et al (2018) Biocompatibility of polyamide 12 intramedullary rod after humeral consolidation in white Plymouth Rock birds. Pesquisa Veterin\u00e1ria Brasileira 38:1909\u20131912. https:\/\/doi.org\/10.1590\/1678-5150-pvb-5776","journal-title":"Pesquisa Veterin\u00e1ria Brasileira"},{"key":"1529_CR21","doi-asserted-by":"publisher","first-page":"440","DOI":"10.3390\/polym14030440","volume":"14","author":"N Vidakis","year":"2022","unstructured":"Vidakis N, Petousis M, Velidakis E et al (2022) Medical-grade polyamide 12 nanocomposite materials for enhanced mechanical and antibacterial performance in 3D printing applications. Polymers (Basel) 14:440. https:\/\/doi.org\/10.3390\/polym14030440","journal-title":"Polymers (Basel)"},{"key":"1529_CR22","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13495","author":"D Ma","year":"2022","unstructured":"Ma D, Gao R, Li M, Qiu J (2022) Mechanical and medical imaging properties of 3D-printed materials as tissue equivalent materials. J Appl Clin Med Phys. https:\/\/doi.org\/10.1002\/acm2.13495","journal-title":"J Appl Clin Med Phys"},{"key":"1529_CR23","doi-asserted-by":"publisher","first-page":"17","DOI":"10.5114\/jcb.2020.92407","volume":"12","author":"F Biltekin","year":"2020","unstructured":"Biltekin F, Akyol H, G\u00fcltekin M, Yildiz F (2020) 3D printer-based novel intensity-modulated vaginal brachytherapy applicator: feasibility study. J Contemp Brachytherapy 12:17\u201326. https:\/\/doi.org\/10.5114\/jcb.2020.92407","journal-title":"J Contemp Brachytherapy"},{"key":"1529_CR24","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1120\/jacmp.v16i1.5168","volume":"16","author":"JAM Cunha","year":"2015","unstructured":"Cunha JAM, Mellis K, Sethi R et al (2015) Evaluation of PC-ISO for customized, 3D printed, gynecologic 192Ir HDR brachytherapy applicators. J Appl Clin Med Phys 16:246\u2013253. https:\/\/doi.org\/10.1120\/jacmp.v16i1.5168","journal-title":"J Appl Clin Med Phys"},{"key":"1529_CR25","doi-asserted-by":"publisher","DOI":"10.1186\/s41205-019-0047-x","author":"RC Laan","year":"2019","unstructured":"Laan RC, Nout RA, Dankelman J, van de Berg NJ (2019) MRI-driven design of customised 3D printed gynaecological brachytherapy applicators with curved needle channels. 3D Print Med. https:\/\/doi.org\/10.1186\/s41205-019-0047-x","journal-title":"3D Print Med"},{"key":"1529_CR26","doi-asserted-by":"publisher","first-page":"468","DOI":"10.5114\/jcb.2021.108602","volume":"13","author":"R Bellis","year":"2021","unstructured":"Bellis R, Rembielak A et al (2021) Additive manufacturing (3D printing) in superficial brachytherapy. J Contemp Brachytherapy 13:468\u2013482. https:\/\/doi.org\/10.5114\/jcb.2021.108602","journal-title":"J Contemp Brachytherapy"},{"key":"1529_CR27","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1186\/s41205-020-00068-3","volume":"6","author":"E Subashi","year":"2020","unstructured":"Subashi E, Jacobs C, Hood R et al (2020) A design process for a 3D printed patient-specific applicator for HDR brachytherapy of the orbit. 3D Print Med 6:15. https:\/\/doi.org\/10.1186\/s41205-020-00068-3","journal-title":"3D Print Med"},{"key":"1529_CR28","unstructured":"ATC Team (2019) HP effect of different sterilization methods on MJF. https:\/\/aerosportadditive.com\/wp-content\/uploads\/2022\/10\/HP-PA12-Sterilization-WP-Aero.pdf"},{"key":"1529_CR29","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/j.radonc.2005.11.014","volume":"78","author":"R P\u00f6tter","year":"2006","unstructured":"P\u00f6tter R, Haie-Meder C, Van Limbergen E et al (2006) Recommendations from gynaecological (GYN) GEC ESTRO working group (II): Concepts and terms in 3D image-based treatment planning in cervix cancer brachytherapy - 3D dose volume parameters and aspects of 3D image-based anatomy, radiation physics, radiobiolo. Radiother Oncol 78:67\u201377. https:\/\/doi.org\/10.1016\/j.radonc.2005.11.014","journal-title":"Radiother Oncol"},{"key":"1529_CR30","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.brachy.2011.07.003","volume":"11","author":"AN Viswanathan","year":"2012","unstructured":"Viswanathan AN, Thomadsen B (2012) American Brachytherapy Society consensus guidelines for locally advanced carcinoma of the cervix. Part I: Gen Princ Brachytherapy 11:33\u201346. https:\/\/doi.org\/10.1016\/j.brachy.2011.07.003","journal-title":"Part I: Gen Princ Brachytherapy"},{"key":"1529_CR31","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.ctro.2018.01.001","volume":"9","author":"R P\u00f6tter","year":"2018","unstructured":"P\u00f6tter R, Tanderup K, Kirisits C et al (2018) The EMBRACE II study: the outcome and prospect of two decades of evolution within the GEC-ESTRO GYN working group and the EMBRACE studies. Clin Transl Radiat Oncol 9:48\u201360. https:\/\/doi.org\/10.1016\/j.ctro.2018.01.001","journal-title":"Clin Transl Radiat Oncol"},{"key":"1529_CR32","doi-asserted-by":"publisher","first-page":"428","DOI":"10.1016\/j.radonc.2016.03.011","volume":"120","author":"A Sturdza","year":"2016","unstructured":"Sturdza A, P\u00f6tter R, Fokdal LU et al (2016) Image guided brachytherapy in cervical cancer Image guided brachytherapy in locally advanced cervical cancer: Improved pelvic control and survival in RetroEMBRACE, a multicenter cohort study. Radiother Oncol 120:428\u2013433. https:\/\/doi.org\/10.1016\/j.radonc.2016.03.011","journal-title":"Radiother Oncol"},{"key":"1529_CR33","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1016\/S0090-8258(03)00230-0","volume":"90","author":"W Irvin","year":"2003","unstructured":"Irvin W, Rice L, Taylor P et al (2003) Uterine perforation at the time of brachytherapy for carcinoma of the cervix. Gynecol Oncol 90:113\u2013122. https:\/\/doi.org\/10.1016\/S0090-8258(03)00230-0","journal-title":"Gynecol Oncol"},{"key":"1529_CR34","doi-asserted-by":"publisher","first-page":"168","DOI":"10.4103\/jmp.JMP_28_18","volume":"43","author":"R Rangarajan","year":"2018","unstructured":"Rangarajan R (2018) Incidence of suboptimal applicator placement and the resulting dosimetric impact in image-based intracavitary brachytherapy. J Med Phys 43:168\u2013172. https:\/\/doi.org\/10.4103\/jmp.JMP_28_18","journal-title":"J Med Phys"},{"key":"1529_CR35","doi-asserted-by":"publisher","first-page":"41","DOI":"10.5114\/JCB.2015.48898","volume":"7","author":"YA Bahadur","year":"2015","unstructured":"Bahadur YA, Eltaher MM, Hassouna AH et al (2015) Uterine perforation and its dosimetric implications in cervical cancer high-dose-rate brachytherapy. J Contemp Brachytherapy 7:41. https:\/\/doi.org\/10.5114\/JCB.2015.48898","journal-title":"J Contemp Brachytherapy"},{"key":"1529_CR36","doi-asserted-by":"publisher","first-page":"130","DOI":"10.5114\/JCB.2023.126441","volume":"15","author":"M Verma","year":"2023","unstructured":"Verma M, Kukreja D, Ghosh A et al (2023) An audit of uterine perforation and its effect on the final outcome in an academic research medical center: An optimized balance between overall treatment time and medical crisis. J Contemp Brachytherapy 15:130. https:\/\/doi.org\/10.5114\/JCB.2023.126441","journal-title":"J Contemp Brachytherapy"}],"container-title":["Physical and Engineering Sciences in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-025-01529-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s13246-025-01529-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-025-01529-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,30]],"date-time":"2025-06-30T07:56:13Z","timestamp":1751270173000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s13246-025-01529-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,3]]},"references-count":36,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025,6]]}},"alternative-id":["1529"],"URL":"https:\/\/doi.org\/10.1007\/s13246-025-01529-x","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-2052596\/v1","asserted-by":"object"}]},"ISSN":["2662-4729","2662-4737"],"issn-type":[{"value":"2662-4729","type":"print"},{"value":"2662-4737","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,3]]},"assertion":[{"value":"13 September 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 February 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 March 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ankur Mourya\n                      ,\n                      Lalit Mohan Aggarwal, Sunil Choudhary, Neeraj Sharma, Ritusha Mishra Chandra Prakash, and Uday Pratap Shahi declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The study was approved by the ethical committee of Institute of Medical Sciences, Banaras Hindu University (approval number: Dean\/2019\/EC\/1732, dated November 18, 2019) having title Modelling and quantitative assessment of neoteric devices for dose delivery in brachytherapy. A written informed consent was taken from all the patients.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}