{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T13:06:43Z","timestamp":1791378403614,"version":"4.3.2"},"reference-count":60,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T00:00:00Z","timestamp":1750204800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T00:00:00Z","timestamp":1750204800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Phys Eng Sci Med"],"published-print":{"date-parts":[[2025,9]]},"DOI":"10.1007\/s13246-025-01562-w","type":"journal-article","created":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T09:18:01Z","timestamp":1750238281000},"page":"999-1014","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Optimum design of a biodegradable implant for femoral shaft fracture fixation using finite element method"],"prefix":"10.1007","volume":"48","author":[{"given":"Sina","family":"Taghipour","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Farid","family":"Vakili-Tahami","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akbar","family":"Allahverdizadeh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,6,18]]},"reference":[{"key":"1562_CR1","doi-asserted-by":"publisher","first-page":"540","DOI":"10.1016\/j.matpr.2022.12.254","volume":"74","author":"FD Al-Shalawi","year":"2023","unstructured":"Al-Shalawi FD et al (2023) Biodegradable synthetic polymer in orthopaedic application: a review. Mater Today: Proc 74:540\u2013546. https:\/\/doi.org\/10.1016\/j.matpr.2022.12.254","journal-title":"Mater Today: Proc"},{"issue":"1","key":"1562_CR2","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1016\/j.jma.2018.11.001","volume":"7","author":"VK Bommala","year":"2019","unstructured":"Bommala VK, Krishna MG, Rao CT (2019) Magnesium matrix composites for biomedical applications: a review. J Magn Alloy 7(1):72\u201379. https:\/\/doi.org\/10.1016\/j.jma.2018.11.001","journal-title":"J Magn Alloy"},{"key":"1562_CR3","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1016\/j.biomaterials.2017.12.025","volume":"196","author":"J Pajarinen","year":"2019","unstructured":"Pajarinen J et al (2019) Mesenchymal stem cell-macrophage crosstalk and bone healing. Biomaterials 196:80\u201389. https:\/\/doi.org\/10.1016\/j.biomaterials.2017.12.025","journal-title":"Biomaterials"},{"key":"1562_CR4","doi-asserted-by":"publisher","first-page":"878257","DOI":"10.3389\/fbioe.2022.878257","volume":"10","author":"M-Q Chen","year":"2022","unstructured":"Chen M-Q (2022) Recent advances and perspective of nanotechnology-based implants for orthopedic applications. Front Bioeng Biotechnol 10:878257. https:\/\/doi.org\/10.3389\/fbioe.2022.878257","journal-title":"Front Bioeng Biotechnol"},{"issue":"12","key":"1562_CR5","doi-asserted-by":"publisher","first-page":"2601","DOI":"10.3390\/polym15122601","volume":"15","author":"FD Al-Shalawi","year":"2023","unstructured":"Al-Shalawi FD et al (2023) Biomaterials as implants in the orthopedic field for regenerative medicine: metal versus synthetic polymers. Polymers 15(12):2601. https:\/\/doi.org\/10.3390\/polym15122601","journal-title":"Polymers"},{"issue":"1","key":"1562_CR6","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1007\/BF02013247","volume":"26","author":"F Driessens","year":"1978","unstructured":"Driessens F, Van Dijk J, Borggreven J (1978) Biological calcium phosphates and their role in the physiology of bone and dental tissues I. Composition and solubility of calcium phosphates. Calcif Tissue Res 26(1):127\u2013137. https:\/\/doi.org\/10.1007\/BF02013247","journal-title":"Calcif Tissue Res"},{"key":"1562_CR7","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1016\/B978-012068700-8\/50009-8","volume-title":"Metabolic bone disease and clinically related disorders","author":"M-C Monier-Faugere","year":"1998","unstructured":"Monier-Faugere M-C, Langub MC, Malluche HH (1998) Bone biopsies: a modern approach. Metabolic bone disease and clinically related disorders. Elsevier, Amsterdam, pp 237\u2013280e"},{"issue":"15","key":"1562_CR8","doi-asserted-by":"publisher","first-page":"1742","DOI":"10.1080\/10255842.2021.1918123","volume":"24","author":"H Ahirwar","year":"2021","unstructured":"Ahirwar H, Gupta VK, Nanda HS (2021) Finite element analysis of fixed bone plates over fractured femur model. Comput Methods Biomech Biomed Engin 24(15):1742\u20131751. https:\/\/doi.org\/10.1080\/10255842.2021.1918123","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"1562_CR9","doi-asserted-by":"publisher","DOI":"10.1007\/s00590-021-03160-4","author":"SF Shams","year":"2023","unstructured":"Shams SF et al (2023) The comparison of stress and strain between custom-designed bone plates (CDBP) and locking compression plate (LCP) for distal femur fracture. Eur J Orthop Surg Traumatol. https:\/\/doi.org\/10.1007\/s00590-021-03160-4","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"1562_CR10","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1016\/j.bonr.2017.03.002","volume":"6","author":"M Ghiasi","year":"2017","unstructured":"Ghiasi M et al (2017) Bone fracture healing in mechanobiological modeling: a review of principles and methods. Bone Rep 6:87\u2013100","journal-title":"Bone Rep"},{"issue":"2","key":"1562_CR11","doi-asserted-by":"publisher","first-page":"596","DOI":"10.1016\/j.bbe.2020.02.003","volume":"40","author":"G Chandra","year":"2020","unstructured":"Chandra G, Pandey A (2020) Biodegradable bone implants in orthopedic applications: a review. Biocybern Biomed Eng 40(2):596\u2013610. https:\/\/doi.org\/10.1016\/j.bbe.2020.02.003","journal-title":"Biocybern Biomed Eng"},{"key":"1562_CR12","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1016\/j.actbio.2015.02.010","volume":"18","author":"A Chaya","year":"2015","unstructured":"Chaya A et al (2015) In vivo study of magnesium plate and screw degradation and bone fracture healing. Acta Biomater 18:262\u2013269. https:\/\/doi.org\/10.1016\/j.actbio.2015.02.010","journal-title":"Acta Biomater"},{"key":"1562_CR13","unstructured":"Institute, J.o. distal-femur-fracture. 2024, may 4. https:\/\/www.joionline.net\/trending\/content\/distal-femur-fracture"},{"issue":"12","key":"1562_CR14","doi-asserted-by":"publisher","first-page":"3233","DOI":"10.1007\/s11517-023-02900-4","volume":"61","author":"S Brouwer de Koning","year":"2023","unstructured":"Brouwer de Koning S et al (2023) Design considerations for patient-specific bone fixation plates: a literature review. Med Biol Eng Comput 61(12):3233\u20133252. https:\/\/doi.org\/10.1007\/s11517-023-02900-4","journal-title":"Med Biol Eng Comput"},{"key":"1562_CR15","doi-asserted-by":"publisher","first-page":"1099","DOI":"10.1007\/s11517-018-1945-6","volume":"57","author":"G Caiti","year":"2019","unstructured":"Caiti G et al (2019) Biomechanical considerations in the design of patient-specific fixation plates for the distal radius. Med Biol Eng Compu 57:1099\u20131107. https:\/\/doi.org\/10.1007\/s11517-018-1945-6","journal-title":"Med Biol Eng Compu"},{"key":"1562_CR16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1471-2474-9-73","volume":"9","author":"B Hanson","year":"2008","unstructured":"Hanson B, van der Werken C, Stengel D (2008) Surgeons\u2019 beliefs and perceptions about removal of orthopaedic implants. BMC Musculoskelet Disord 9:1\u20138. https:\/\/doi.org\/10.1186\/1471-2474-9-73","journal-title":"BMC Musculoskelet Disord"},{"key":"1562_CR17","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1007\/s00776-005-0984-7","volume":"11","author":"HK Uhthoff","year":"2006","unstructured":"Uhthoff HK, Poitras P, Backman DS (2006) Internal plate fixation of fractures: short history and recent developments. J Orthop Sci 11:118\u2013126","journal-title":"J Orthop Sci"},{"key":"1562_CR18","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.actbio.2019.01.035","volume":"87","author":"J Venezuela","year":"2019","unstructured":"Venezuela J, Dargusch M (2019) The influence of alloying and fabrication techniques on the mechanical properties, biodegradability and biocompatibility of zinc: a comprehensive review. Acta Biomater 87:1\u201340. https:\/\/doi.org\/10.1016\/j.actbio.2019.01.035","journal-title":"Acta Biomater"},{"key":"1562_CR19","doi-asserted-by":"publisher","DOI":"10.1016\/j.matdes.2019.108154","volume":"183","author":"M W\u0105troba","year":"2019","unstructured":"W\u0105troba M et al (2019) Design of novel Zn-Ag-Zr alloy with enhanced strength as a potential biodegradable implant material. Mater Des 183:108154. https:\/\/doi.org\/10.1016\/j.matdes.2019.108154","journal-title":"Mater Des"},{"key":"1562_CR20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jot.2018.06.006","volume":"16","author":"L Tian","year":"2019","unstructured":"Tian L et al (2019) Hybrid fracture fixation systems developed for orthopaedic applications: a general review. J Orthop Transl 16:1\u201313. https:\/\/doi.org\/10.1016\/j.jot.2018.06.006","journal-title":"J Orthop Transl"},{"issue":"7","key":"1562_CR21","doi-asserted-by":"publisher","first-page":"3463","DOI":"10.1016\/j.matdes.2010.01.036","volume":"31","author":"M Grujicic","year":"2010","unstructured":"Grujicic M et al (2010) Design-optimization and material selection for a femoral-fracture fixation-plate implant. Mater Des 31(7):3463\u20133473. https:\/\/doi.org\/10.1016\/j.matdes.2010.01.036","journal-title":"Mater Des"},{"issue":"5","key":"1562_CR22","doi-asserted-by":"publisher","first-page":"973","DOI":"10.1016\/j.joms.2008.12.032","volume":"67","author":"ST Lovald","year":"2009","unstructured":"Lovald ST et al (2009) Biomechanical optimization of bone plates used in rigid fixation of mandibular fractures. J Oral Maxillofac Surg 67(5):973\u2013985. https:\/\/doi.org\/10.1016\/j.joms.2008.12.032","journal-title":"J Oral Maxillofac Surg"},{"issue":"20","key":"1562_CR23","doi-asserted-by":"publisher","first-page":"10569","DOI":"10.3390\/app122010569","volume":"12","author":"AA Al-Tamimi","year":"2022","unstructured":"Al-Tamimi AA (2022) Topology optimization of patient-specific custom-fit distal tibia plate: a spiral distal tibia bone fracture. Appl Sci 12(20):10569. https:\/\/doi.org\/10.3390\/app122010569","journal-title":"Appl Sci"},{"issue":"4","key":"1562_CR24","doi-asserted-by":"publisher","first-page":"1461","DOI":"10.1007\/s13246-024-01456-3","volume":"47","author":"Y Li","year":"2024","unstructured":"Li Y et al (2024) Finite element simulation of treatment with locking plate for distal fibula fractures. Phys Eng Sci Med 47(4):1461\u20131468. https:\/\/doi.org\/10.1007\/s13246-024-01456-3","journal-title":"Phys Eng Sci Med"},{"issue":"3","key":"1562_CR25","doi-asserted-by":"publisher","first-page":"1101","DOI":"10.1007\/s13246-023-01277-w","volume":"46","author":"BC Jeong","year":"2023","unstructured":"Jeong BC et al (2023) Identification of screw spacing on pediatric hip locking plate in proximal femoral osteotomy. Phys Eng Sci Med 46(3):1101\u20131114. https:\/\/doi.org\/10.1007\/s13246-023-01277-w","journal-title":"Phys Eng Sci Med"},{"key":"1562_CR26","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1097\/00003086-199306000-00008","volume":"291","author":"KP Speer","year":"1993","unstructured":"Speer KP, Warren RF (1993) Arthroscopic shoulder stabilization: a role for biodegradable materials. Clin Orthop Related Res 291:67\u201374","journal-title":"Clin Orthop Related Res"},{"key":"1562_CR27","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1016\/j.bioactmat.2023.08.015","volume":"31","author":"B Huang","year":"2024","unstructured":"Huang B et al (2024) Absorbable implants in sport medicine and arthroscopic surgery: a narrative review of recent development. Bioact Mater 31:272\u2013283. https:\/\/doi.org\/10.1016\/j.bioactmat.2023.08.015","journal-title":"Bioact Mater"},{"key":"1562_CR28","doi-asserted-by":"publisher","first-page":"242","DOI":"10.1016\/j.matlet.2015.07.151","volume":"162","author":"X Liu","year":"2016","unstructured":"Liu X et al (2016) Microstructure, mechanical properties, in vitro degradation behavior and hemocompatibility of novel Zn\u2013Mg\u2013Sr alloys as biodegradable metals. Mater Lett 162:242\u2013245. https:\/\/doi.org\/10.1016\/j.matlet.2015.07.151","journal-title":"Mater Lett"},{"issue":"9","key":"1562_CR29","doi-asserted-by":"publisher","first-page":"8199","DOI":"10.3390\/nu7095388","volume":"7","author":"U Gr\u00f6ber","year":"2015","unstructured":"Gr\u00f6ber U, Schmidt J, Kisters K (2015) Magnesium in prevention and therapy. Nutrients 7(9):8199\u20138226. https:\/\/doi.org\/10.3390\/nu7095388","journal-title":"Nutrients"},{"key":"1562_CR30","doi-asserted-by":"publisher","first-page":"105306","DOI":"10.1016\/j.jmbbm.2022.105306","volume":"133","author":"P Lemoine","year":"2022","unstructured":"Lemoine P et al (2022) Nanoindentation and nano-scratching of hydroxyapatite coatings for resorbable magnesium alloy bone implant applications. J Mech Behav Biomed Mater 133:105306. https:\/\/doi.org\/10.1016\/j.jmbbm.2022.105306","journal-title":"J Mech Behav Biomed Mater"},{"key":"1562_CR31","doi-asserted-by":"publisher","first-page":"108259","DOI":"10.1016\/j.matdes.2019.108259","volume":"185","author":"Y Yang","year":"2020","unstructured":"Yang Y et al (2020) Mg bone implant: features, developments and perspectives. Mater Des 185:108259. https:\/\/doi.org\/10.1016\/j.matdes.2019.108259","journal-title":"Mater Des"},{"issue":"9","key":"1562_CR32","doi-asserted-by":"publisher","first-page":"5744","DOI":"10.3390\/ma8095273","volume":"8","author":"Z Sheikh","year":"2015","unstructured":"Sheikh Z et al (2015) Biodegradable materials for bone repair and tissue engineering applications. Materials 8(9):5744\u20135794. https:\/\/doi.org\/10.3390\/ma8095273","journal-title":"Materials"},{"key":"1562_CR33","doi-asserted-by":"publisher","DOI":"10.1533\/9780857097217.254","author":"J Kundu","year":"2014","unstructured":"Kundu J et al (2014) Rapid prototyping technology for bone regeneration. Rapid Prototyp Biomater. https:\/\/doi.org\/10.1533\/9780857097217.254","journal-title":"Rapid Prototyp Biomater"},{"issue":"5","key":"1562_CR34","doi-asserted-by":"publisher","first-page":"545","DOI":"10.1016\/0021-9681(66)90094-4","volume":"19","author":"HA Schroeder","year":"1966","unstructured":"Schroeder HA, Balassa JJ, Tipton IH (1966) Essential trace metals in man: manganese: a study in homeostasis. J Chronic Dis 19(5):545\u2013571. https:\/\/doi.org\/10.1016\/0021-9681(66)90094-4","journal-title":"J Chronic Dis"},{"key":"1562_CR35","doi-asserted-by":"publisher","first-page":"948","DOI":"10.1016\/j.msec.2016.06.020","volume":"68","author":"S Agarwal","year":"2016","unstructured":"Agarwal S et al (2016) Biodegradable magnesium alloys for orthopaedic applications: a review on corrosion, biocompatibility and surface modifications. Mater Sci Eng C 68:948\u2013963. https:\/\/doi.org\/10.1016\/j.msec.2016.06.020","journal-title":"Mater Sci Eng C"},{"issue":"2","key":"1562_CR36","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1080\/03067318408079924","volume":"17","author":"L Fishbein","year":"1984","unstructured":"Fishbein L (1984) Overview of analysis of carcinogenic and\/or mutagenic metals in biological and environmental samples I. Arsenic, beryllium, cadmium, chromium and selenium. Int J Environ Anal Chem 17(2):113\u2013170. https:\/\/doi.org\/10.1080\/03067318408079924","journal-title":"Int J Environ Anal Chem"},{"issue":"12","key":"1562_CR37","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1080\/10667857.2016.1212587","volume":"31","author":"J Chen","year":"2016","unstructured":"Chen J, Tan L, Yang K (2016) Recent advances on the development of biodegradable magnesium alloys: a review. Mater Technol 31(12):681\u2013688. https:\/\/doi.org\/10.1080\/10667857.2016.1212587","journal-title":"Mater Technol"},{"issue":"3","key":"1562_CR38","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/S0021-5198(19)35850-0","volume":"64","author":"T Morohashi","year":"1994","unstructured":"Morohashi T, Sano T, Yamada S (1994) Effects of strontium on calcium metabolism in rats i. A distinction between the pharmacological and toxic doses. Jpn J Pharmacol 64(3):155\u2013162. https:\/\/doi.org\/10.1016\/S0021-5198(19)35850-0","journal-title":"Jpn J Pharmacol"},{"key":"1562_CR39","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1155\/2013\/429496","volume":"20","author":"R Long","year":"2013","unstructured":"Long R et al (2013) Marked disparity in the epidemiology of tuberculosis among aboriginal peoples on the Canadian prairies: the challenges and opportunities. Can Respir J 20:223\u2013230. https:\/\/doi.org\/10.1155\/2013\/429496","journal-title":"Can Respir J"},{"issue":"1","key":"1562_CR40","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1002\/(SICI)1527-2648(199909)1:1","volume":"1","author":"GL Song","year":"1999","unstructured":"Song GL, Atrens A (1999) Corrosion mechanisms of magnesium alloys. Adv Eng Mater 1(1):11\u201333. https:\/\/doi.org\/10.1002\/(SICI)1527-2648(199909)1:1","journal-title":"Adv Eng Mater"},{"issue":"12","key":"1562_CR41","doi-asserted-by":"publisher","first-page":"837","DOI":"10.1002\/adem.200310405","volume":"5","author":"G Song","year":"2003","unstructured":"Song G, Atrens A (2003) Understanding magnesium corrosion\u2014a framework for improved alloy performance. Adv Eng Mater 5(12):837\u2013858. https:\/\/doi.org\/10.1002\/adem.200310405","journal-title":"Adv Eng Mater"},{"key":"1562_CR42","doi-asserted-by":"publisher","first-page":"639","DOI":"10.1016\/j.jallcom.2014.09.061","volume":"619","author":"Y Ali","year":"2015","unstructured":"Ali Y et al (2015) Current research progress in grain refinement of cast magnesium alloys: a review article. J Alloy Compd 619:639\u2013651. https:\/\/doi.org\/10.1016\/j.jallcom.2014.09.061","journal-title":"J Alloy Compd"},{"key":"1562_CR43","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1007\/s11837-009-0129-0","volume":"61","author":"HS Brar","year":"2009","unstructured":"Brar HS et al (2009) Magnesium as a biodegradable and bioabsorbable material for medical implants. Jom 61:31\u201334. https:\/\/doi.org\/10.1007\/s11837-009-0129-0","journal-title":"Jom"},{"key":"1562_CR44","doi-asserted-by":"publisher","first-page":"101680","DOI":"10.1016\/j.mtla.2023.101680","volume":"27","author":"B Venkateswarlu","year":"2023","unstructured":"Venkateswarlu B, Sunil BR, Kumar RS (2023) Magnesium based alloys and composites: revolutionized biodegradable temporary implants and strategies to enhance their performance. Materialia 27:101680. https:\/\/doi.org\/10.1016\/j.mtla.2023.101680","journal-title":"Materialia"},{"key":"1562_CR45","doi-asserted-by":"publisher","first-page":"1098","DOI":"10.1007\/s12540-018-00232-9","volume":"25","author":"J-K Jeon","year":"2019","unstructured":"Jeon J-K et al (2019) Conceptual study for tissue-regenerative biodegradable magnesium implant integrated with nitric oxide-releasing nanofibers. Met Mater Int 25:1098\u20131107. https:\/\/doi.org\/10.1007\/s12540-018-00232-9","journal-title":"Met Mater Int"},{"key":"1562_CR46","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1016\/j.jallcom.2016.05.241","volume":"685","author":"Z Gui","year":"2016","unstructured":"Gui Z, Kang Z, Li Y (2016) Mechanical and corrosion properties of Mg-Gd-Zn-Zr-Mn biodegradable alloy by hot extrusion. J Alloy Compd 685:222\u2013230. https:\/\/doi.org\/10.1016\/j.jallcom.2016.05.241","journal-title":"J Alloy Compd"},{"key":"1562_CR47","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1016\/j.jmbbm.2018.01.028","volume":"80","author":"Y Zhang","year":"2018","unstructured":"Zhang Y, Li J, Li J (2018) Effects of microstructure transformation on mechanical properties, corrosion behaviors of Mg-Zn-Mn-Ca alloys in simulated body fluid. J Mech Behav Biomed Mater 80:246\u2013257. https:\/\/doi.org\/10.1016\/j.jmbbm.2018.01.028","journal-title":"J Mech Behav Biomed Mater"},{"key":"1562_CR48","doi-asserted-by":"publisher","first-page":"290","DOI":"10.1016\/j.jallcom.2017.01.178","volume":"702","author":"Z Li","year":"2017","unstructured":"Li Z et al (2017) The synergistic effect of trace Sr and Zr on the microstructure and properties of a biodegradable Mg-Zn-Zr-Sr alloy. J Alloy Compd 702:290\u2013302. https:\/\/doi.org\/10.1016\/j.jallcom.2017.01.178","journal-title":"J Alloy Compd"},{"issue":"1","key":"1562_CR49","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1016\/j.bioactmat.2016.12.002","volume":"2","author":"J Chen","year":"2017","unstructured":"Chen J, Tan L, Yang K (2017) Effect of heat treatment on mechanical and biodegradable properties of an extruded ZK60 alloy. Bioact Mater 2(1):19\u201326. https:\/\/doi.org\/10.1016\/j.bioactmat.2016.12.002","journal-title":"Bioact Mater"},{"key":"1562_CR50","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1016\/j.jmbbm.2017.01.005","volume":"69","author":"H Ibrahim","year":"2017","unstructured":"Ibrahim H et al (2017) Microstructural, mechanical and corrosion characteristics of heat-treated Mg-1.2 Zn-0.5 Ca (wt%) alloy for use as resorbable bone fixation material. J Mech Behav Biomed Mater 69:203\u2013212. https:\/\/doi.org\/10.1016\/j.jmbbm.2017.01.005","journal-title":"J Mech Behav Biomed Mater"},{"issue":"5","key":"1562_CR51","doi-asserted-by":"publisher","first-page":"1800","DOI":"10.1016\/j.actbio.2010.02.027","volume":"6","author":"A Purnama","year":"2010","unstructured":"Purnama A et al (2010) Assessing the biocompatibility of degradable metallic materials: state-of-the-art and focus on the potential of genetic regulation. Acta Biomater 6(5):1800\u20131807. https:\/\/doi.org\/10.1016\/j.actbio.2010.02.027","journal-title":"Acta Biomater"},{"issue":"9","key":"1562_CR52","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1007\/s42452-023-05477-7","volume":"5","author":"EM Safwat","year":"2023","unstructured":"Safwat EM et al (2023) Corrosion behavior, mechanical properties, and in-vitro biocompatibility of cast Mg\u20133Zn\u2013xSi biodegradable alloys for bone regeneration. SN Appl Sci 5(9):251. https:\/\/doi.org\/10.1007\/s42452-023-05477-7","journal-title":"SN Appl Sci"},{"key":"1562_CR53","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1016\/j.medengphy.2020.05.010","volume":"81","author":"G Chandra","year":"2020","unstructured":"Chandra G et al (2020) Design of a biodegradable plate for femoral shaft fracture fixation. Med Eng Phys 81:86\u201396","journal-title":"Med Eng Phys"},{"issue":"4","key":"1562_CR54","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1002\/jor.22023","volume":"30","author":"BJ Fregly","year":"2012","unstructured":"Fregly BJ et al (2012) Grand challenge competition to predict in vivo knee loads. J Orthop Res 30(4):503\u2013513. https:\/\/doi.org\/10.1002\/jor.22023","journal-title":"J Orthop Res"},{"issue":"5","key":"1562_CR55","doi-asserted-by":"publisher","first-page":"1155","DOI":"10.1016\/j.jbiomech.2004.05.022","volume":"38","author":"M Heller","year":"2005","unstructured":"Heller M et al (2005) Determination of muscle loading at the hip joint for use in pre-clinical testing. J Biomech 38(5):1155\u20131163. https:\/\/doi.org\/10.1016\/j.jbiomech.2004.05.022","journal-title":"J Biomech"},{"issue":"7","key":"1562_CR56","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1016\/s0021-9290(01)00040-9","volume":"34","author":"G Bergmann","year":"2001","unstructured":"Bergmann G et al (2001) Hip contact forces and gait patterns from routine activities. J Biomech 34(7):859\u2013871. https:\/\/doi.org\/10.1016\/s0021-9290(01)00040-9","journal-title":"J Biomech"},{"key":"1562_CR57","volume-title":"Design of material structures using topology optimization","author":"O Sigmund","year":"1994","unstructured":"Sigmund O (1994) Design of material structures using topology optimization. Technical University of Denmark, Lyngby"},{"issue":"1","key":"1562_CR58","doi-asserted-by":"publisher","first-page":"10323","DOI":"10.1038\/s41598-024-61204-1","volume":"14","author":"X Chen","year":"2024","unstructured":"Chen X, Yan G, Hosseinzadeh H (2024) Topology optimization of the flat steel shear wall based on the volume constraint and strain energy assumptions under the seismic loading conditions. Sci Rep 14(1):10323. https:\/\/doi.org\/10.1038\/s41598-024-61204-1","journal-title":"Sci Rep"},{"key":"1562_CR59","doi-asserted-by":"publisher","first-page":"116206","DOI":"10.1016\/j.bone.2021.116206","volume":"154","author":"M Revel","year":"2022","unstructured":"Revel M et al (2022) Influence of loading conditions in finite element analysis assessed by HR\u2013pQCT on ex vivo fracture prediction. Bone 154:116206. https:\/\/doi.org\/10.1016\/j.bone.2021.116206","journal-title":"Bone"},{"key":"1562_CR60","volume-title":"Mechanical behavior of materials: engineering methods for deformation, fracture, and fatigue","author":"NE Dowling","year":"2013","unstructured":"Dowling NE (2013) Mechanical behavior of materials: engineering methods for deformation, fracture, and fatigue. Pearson, London"}],"updated-by":[{"DOI":"10.1007\/s13246-025-01697-w","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2026,1,26]],"date-time":"2026-01-26T00:00:00Z","timestamp":1769385600000}}],"container-title":["Physical and Engineering Sciences in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-025-01562-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s13246-025-01562-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-025-01562-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,26]],"date-time":"2026-01-26T15:20:32Z","timestamp":1769440832000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s13246-025-01562-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,18]]},"references-count":60,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025,9]]}},"alternative-id":["1562"],"URL":"https:\/\/doi.org\/10.1007\/s13246-025-01562-w","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-4769010\/v1","asserted-by":"object"}]},"ISSN":["2662-4729","2662-4737"],"issn-type":[{"value":"2662-4729","type":"print"},{"value":"2662-4737","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,18]]},"assertion":[{"value":"19 July 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 May 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 June 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 January 2026","order":5,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Update","order":6,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The original version of this article was revised: A processing error occurred in Figure 9, resulting in missing information. The figure has been corrected.","order":7,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 January 2026","order":8,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":9,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A Correction to this paper has been published:","order":10,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1007\/s13246-025-01697-w","URL":"https:\/\/doi.org\/10.1007\/s13246-025-01697-w","order":11,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not involve any studies with human participants or animals. Therefore, ethics approval was not required.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}}]}}