{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T19:24:47Z","timestamp":1792783487650,"version":"4.5.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2026,3,30]],"date-time":"2026-03-30T00:00:00Z","timestamp":1774828800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,3,30]],"date-time":"2026-03-30T00:00:00Z","timestamp":1774828800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Queensland University of Technology","id":[{"id":"https:\/\/ror.org\/03pnv4752","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Phys Eng Sci Med"],"published-print":{"date-parts":[[2026,9]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Children are more radiosensitive than adults, making dose optimisation in paediatric computed tomography (CT) essential. Although Diagnostic Reference Levels (DRLs) are internationally recommended as optimisation tools, national DRLs for paediatric CT in Jordan remain limited and outdated. This study aimed to establish national DRLs for six paediatric CT protocols, evaluate inter-hospital and age-related dose variations, and compare results with international benchmarks. A retrospective multicentre study was conducted across six Jordanian hospitals between December 2023 and September 2025, including 3794 paediatric patients stratified into four age groups (&lt;\u20091, 1\u20134, 5\u201310, and 11\u201318\u00a0years). Volumetric CT dose index (CTDI\n                    <jats:sub>vol<\/jats:sub>\n                    ) and dose-length product (DLP) data were collected for six protocols: brain, chest, abdomen\u2013pelvis, chest\u2013abdomen\u2013pelvis, sinuses, and contrast-enhanced neck soft tissue. DRLs were defined as the 75th percentile of institutional median CTDI\n                    <jats:sub>vol<\/jats:sub>\n                    and DLP values. Inter-hospital and age group variations were analysed, and univariable regression analyses assessed acquisition parameters associated with dose variation. Dose increased with patient age for trunk protocols, whereas brain, sinuses, and neck CT showed comparatively stable patterns. Substantial inter-hospital variability was observed across protocols, with institutional median CTDIvol differing markedly between centres, particularly for trunk examinations in younger age groups. In univariable regression analyses, all four acquisition parameters (kVp, mAs, pitch, and slice thickness) were significantly associated with CTDI\n                    <jats:sub>vol<\/jats:sub>\n                    and DLP (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009\u2264\u20090.001), with kVp demonstrating the strongest association (R\n                    <jats:sup>2<\/jats:sup>\n                    \u2009=\u20090.603 for CTDI\n                    <jats:sub>vol<\/jats:sub>\n                    ; R\n                    <jats:sup>2<\/jats:sup>\n                    \u2009=\u20090.630 for DLP). Compared with published international DRLs, Jordanian brain CT dose metrics were higher in multiple age groups; chest comparisons should be interpreted cautiously where international benchmarks are weight-banded. This study established national paediatric CT DRLs for Jordan, highlighting the need for standardised protocols and periodic DRL review to enhance radiation protection.\n                  <\/jats:p>","DOI":"10.1007\/s13246-026-01731-5","type":"journal-article","created":{"date-parts":[[2026,3,30]],"date-time":"2026-03-30T13:42:09Z","timestamp":1774878129000},"page":"1179-1190","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Proposing diagnostic reference levels for paediatric computed tomography in Jordan: a national multicentre analysis"],"prefix":"10.1007","volume":"49","author":[{"given":"Abdel-Baset","family":"Bani Yaseen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jamie","family":"Trapp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Davide","family":"Fontanarosa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,30]]},"reference":[{"key":"1731_CR1","first-page":"38","volume":"1","author":"R Scholz","year":"1994","unstructured":"Scholz R (1994) On the sensitivity of children to radiation. Med Glob Surviv 1:38\u201344","journal-title":"Med Glob Surviv"},{"issue":"2\u20134","key":"1731_CR2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.icrp.2007.10.003","volume":"37","author":"International Commission on Radiological Protection","year":"2007","unstructured":"International Commission on Radiological Protection (2007) The 2007 recommendations of the international commission on radiological protection. Ann ICRP 37(2\u20134):1\u2013332. https:\/\/doi.org\/10.1016\/j.icrp.2007.10.003","journal-title":"Ann ICRP"},{"issue":"2","key":"1731_CR3","first-page":"94","volume":"3","author":"KJ Strauss","year":"2015","unstructured":"Strauss KJ, Frush DP, Goske MJ (2015) Image Gently campaign: making a world of difference. Med Phys Int 3(2):94\u2013108","journal-title":"Med Phys Int"},{"key":"1731_CR4","unstructured":"United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). Sources, Effects and Risks of Ionizing Radiation: UNSCEAR 2020\/2021 Report to the General Assembly, with Scientific Annexes. Volume I: Scientific Annex A\u2014Evaluation of medical exposure to ionizing radiation. New York: United Nations; 2022. ISBN: 978\u201192\u20111\u2011139206\u20117."},{"issue":"1","key":"1731_CR5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/0146645317717209","volume":"46","author":"E Va\u00f1\u00f3","year":"2017","unstructured":"Va\u00f1\u00f3 E, Miller DL, Martin CJ, Rehani MM, Kang K, Rosenstein M et al (2017) Diagnostic reference levels in medical imaging: ICRP publication 135. Ann ICRP 46(1):1\u2013144. https:\/\/doi.org\/10.1177\/0146645317717209","journal-title":"Ann ICRP"},{"issue":"1129","key":"1731_CR6","doi-asserted-by":"publisher","first-page":"20210796","DOI":"10.1259\/bjr.20210796","volume":"95","author":"M Worrall","year":"2022","unstructured":"Worrall M, Holubinka M, Havariyoun G, Hodgson K, Edyvean S, Holroyd J et al (2022) Analysis and results from a UK national dose audit of paediatric CT examinations. Br J Radiol 95(1129):20210796. https:\/\/doi.org\/10.1259\/bjr.20210796","journal-title":"Br J Radiol"},{"issue":"4","key":"1731_CR7","doi-asserted-by":"publisher","first-page":"1060","DOI":"10.1088\/1361-6498\/ab3ee2","volume":"39","author":"M Rawashdeh","year":"2019","unstructured":"Rawashdeh M, Abdelrahman M, Zaitoun M, Saade C, Alewaidat H, McEntee MF (2019) Diagnostic reference levels for paediatric CT in Jordan. J Radiol Prot 39(4):1060\u20131073","journal-title":"J Radiol Prot"},{"issue":"6","key":"1731_CR8","doi-asserted-by":"publisher","first-page":"103158","DOI":"10.1016\/j.radi.2025.103158","volume":"31","author":"SF Hamedat","year":"2025","unstructured":"Hamedat SF, Md Radzi Y, Salman MD, Al\u2011 Shipli MA (2025) Evaluation of paediatric head CT radiation dose in Jordan: a new national diagnostic reference level survey. Radiography 31(6):103158. https:\/\/doi.org\/10.1016\/j.radi.2025.103158","journal-title":"Radiography"},{"key":"1731_CR9","volume-title":"Radiation protection No. 185: European guidelines on diagnostic reference levels for paediatric imaging","author":"European Commission","year":"2018","unstructured":"European Commission (2018) Radiation protection No. 185: European guidelines on diagnostic reference levels for paediatric imaging. Publications Office of the European Union, Luxembourg"},{"key":"1731_CR10","volume-title":"The measurement, reporting, and management of radiation dose in CT. AAPM report No. 96","author":"American Association of Physicists in Medicine","year":"2008","unstructured":"American Association of Physicists in Medicine (2008) The measurement, reporting, and management of radiation dose in CT. AAPM report No. 96. AAPM, College Park (MD)"},{"key":"#cr-split#-1731_CR11.1","unstructured":"UK Health Security Agency. National Diagnostic Reference Levels (NDRLs) from 11 December 2025 [Internet]. GOV.UK"},{"key":"#cr-split#-1731_CR11.2","unstructured":"2025 [cited 2026 Feb 24]. Available from: https:\/\/www.gov.uk\/government\/publications\/diagnostic-radiology-national-diagnostic-reference-levels-ndrls\/ndrl."},{"key":"1731_CR12","unstructured":"Bundesamt f\u00fcr Strahlenschutz. Bekanntmachung der aktualisierten diagnostischen Referenzwerte f\u00fcr diagnostische und interventionelle R\u00f6ntgenanwendungen (vom 17. November 2022). Bundesanzeiger. 2023 Jan 11."},{"issue":"9","key":"1731_CR13","doi-asserted-by":"publisher","first-page":"1980","DOI":"10.1007\/s00330-008-0963-4","volume":"18","author":"FR Verdun","year":"2008","unstructured":"Verdun FR, Gutierrez D, Vader JP, Aroua A, Alamo\u2011 Maestre LT, Bochud F et al (2008) CT radiation dose in children: a survey to establish age\u2011based diagnostic reference levels in Switzerland. Eur Radiol 18(9):1980\u20131986","journal-title":"Eur Radiol"},{"issue":"50","key":"1731_CR14","doi-asserted-by":"publisher","first-page":"e2146","DOI":"10.1097\/MD.0000000000002146","volume":"94","author":"JY Hwang","year":"2015","unstructured":"Hwang JY, Do KH, Yang DH, Cho YA, Yoon HK, Lee JS et al (2015) A survey of pediatric CT protocols and radiation doses in South Korean hospitals to optimize the radiation dose for pediatric CT scanning. Medicine (Baltimore) 94(50):e2146. https:\/\/doi.org\/10.1097\/MD.0000000000002146","journal-title":"Medicine (Baltimore)"},{"issue":"9","key":"1731_CR15","first-page":"216","volume":"13","author":"MO Adelodun","year":"2024","unstructured":"Adelodun MO, Anyanwu EC (2024) Global standards in radiation safety: a comparative analysis of healthcare regulations. Int J Eng Inventions 13(9):216\u2013227","journal-title":"Int J Eng Inventions"},{"key":"1731_CR16","volume-title":"Paediatric patients dose optimisation and risk assessment in computed tomography examination [thesis]","author":"TA Sackey","year":"2022","unstructured":"Sackey TA (2022) Paediatric patients dose optimisation and risk assessment in computed tomography examination [thesis]. University of Cape Coast, Cape Coast (Ghana)"},{"issue":"43","key":"1731_CR17","doi-asserted-by":"publisher","first-page":"721","DOI":"10.3238\/arztebl.2016.0721","volume":"113","author":"R Pokora","year":"2016","unstructured":"Pokora R, Krille L, Dreger S, Lee C, G\u00fcnster C, Zeeb H et al (2016) Computed tomography in Germany: results and insights from a cohort study and health insurance data (AOK). Dtsch Arztebl Int 113(43):721\u2013728. https:\/\/doi.org\/10.3238\/arztebl.2016.0721","journal-title":"Dtsch Arztebl Int"},{"issue":"948","key":"1731_CR18","doi-asserted-by":"publisher","first-page":"968","DOI":"10.1259\/bjr\/93277434","volume":"79","author":"PC Shrimpton","year":"2006","unstructured":"Shrimpton PC, Hillier MC, Lewis MA, Dunn M (2006) National survey of doses from CT in the UK: 2003. Br J Radiol 79(948):968\u2013980. https:\/\/doi.org\/10.1259\/bjr\/93277434","journal-title":"Br J Radiol"},{"issue":"7 Suppl","key":"1731_CR19","doi-asserted-by":"publisher","first-page":"S263","DOI":"10.1016\/j.jvir.2009.04.037","volume":"20","author":"MS Stecker","year":"2009","unstructured":"Stecker MS, Balter S, Towbin RB, Miller DL, Va\u00f1\u00f3 E, Bartal G et al (2009) Guidelines for patient radiation dose management. J Vasc Interv Radiol 20(7 Suppl):S263\u2013S273. https:\/\/doi.org\/10.1016\/j.jvir.2009.04.037","journal-title":"J Vasc Interv Radiol"},{"issue":"6","key":"1731_CR20","doi-asserted-by":"publisher","first-page":"810","DOI":"10.1001\/jamainternmed.2017.0445","volume":"177","author":"J Demb","year":"2017","unstructured":"Demb J, Chu P, Nelson T, Hall D, Seibert A, Lamba R et al (2017) Optimizing radiation doses for computed tomography across institutions: dose auditing and best practices. JAMA Intern Med 177(6):810\u2013817. https:\/\/doi.org\/10.1001\/jamainternmed.2017.0445","journal-title":"JAMA Intern Med"},{"key":"1731_CR21","doi-asserted-by":"crossref","unstructured":"Papadakis A, Stratakis J, Tsapaki V. (2019) Optimisation of examinations performed on paediatric patients. In: Damilakis J, editor. Radiation Dose Management of Pregnant Patients, Pregnant Staff and Paediatric Patients: Diagnostic and Interventional Radiology. Bristol (UK): IOP Publishing; p. 7\u20111\u20137\u201132.","DOI":"10.1088\/978-0-7503-1317-9ch7"},{"issue":"1048","key":"1731_CR22","doi-asserted-by":"publisher","first-page":"20140344","DOI":"10.1259\/bjr.20140344","volume":"88","author":"MM Rehani","year":"2015","unstructured":"Rehani MM (2015) Limitations of diagnostic reference level (DRL) and introduction of acceptable quality dose (AQD). Br J Radiol 88(1048):20140344. https:\/\/doi.org\/10.1259\/bjr.20140344","journal-title":"Br J Radiol"}],"container-title":["Physical and Engineering Sciences in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-026-01731-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s13246-026-01731-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-026-01731-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T23:06:13Z","timestamp":1791241573000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s13246-026-01731-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,30]]},"references-count":23,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,9]]}},"alternative-id":["1731"],"URL":"https:\/\/doi.org\/10.1007\/s13246-026-01731-5","relation":{},"ISSN":["2662-4729","2662-4737"],"issn-type":[{"value":"2662-4729","type":"print"},{"value":"2662-4737","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,30]]},"assertion":[{"value":"3 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors have no relevant financial or non-financial interests to disclose.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study received ethical clearance from both Australian and Jordanian ethics bodies. Approval was granted by the Queensland University of Technology (QUT) Human Research Ethics Advisory Team (Approval No. 7324), in line with the principles outlined in the National Statement on Ethical Conduct in Human Research (2007, updated 2018). A waiver of consent for retrospective access to clinical imaging data was approved under Section 2.3.10 of the National Statement. Ethical approval was also obtained from the Scientific Research Ethics Committee in Jordan (Approval No. SREC\/22112167), which authorised the study's conduct at participating centres.","order":2,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":3,"name":"Ethics","label":"Consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":4,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}}]}}