{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T19:24:22Z","timestamp":1792783462274,"version":"4.5.0"},"reference-count":49,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2026,6,8]],"date-time":"2026-06-08T00:00:00Z","timestamp":1780876800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,6,8]],"date-time":"2026-06-08T00:00:00Z","timestamp":1780876800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"Jiangxi Cancer Hospital & Institute","award":["WCDJ2024JQ01"],"award-info":[{"award-number":["WCDJ2024JQ01"]}],"id":[{"id":"https:\/\/ror.org\/00v8g0168","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Phys Eng Sci Med"],"published-print":{"date-parts":[[2026,9]]},"DOI":"10.1007\/s13246-026-01750-2","type":"journal-article","created":{"date-parts":[[2026,6,8]],"date-time":"2026-06-08T10:29:26Z","timestamp":1780914566000},"page":"1383-1391","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Complementary roles of GPU-accelerated Monte Carlo and ArcCHECK in TomoTherapy quality assurance"],"prefix":"10.1007","volume":"49","author":[{"given":"Panxia","family":"Wu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenheng","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Longfei","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"XingXing","family":"Yuan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Changfei","family":"Gong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Changwei","family":"Luo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junming","family":"Jian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shenggou","family":"Ding","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yun","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,8]]},"reference":[{"key":"1750_CR1","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2023.1114652","volume":"13","author":"F Zhao","year":"2023","unstructured":"Zhao F, Yang D, Li X (2023) Effect of radiotherapy interruption on nasopharyngeal cancer. Front Oncol 13:1114652. https:\/\/doi.org\/10.3389\/fonc.2023.1114652","journal-title":"Front Oncol"},{"issue":"1","key":"1750_CR2","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1002\/pro6.1219","volume":"8","author":"Z Zhang","year":"2024","unstructured":"Zhang Z, Chen X, Yuan T (2024) Precision radiotherapy for nasopharyngeal carcinoma. Precis Radiat Oncol 8(1):37\u201341. https:\/\/doi.org\/10.1002\/pro6.1219","journal-title":"Precis Radiat Oncol"},{"issue":"2","key":"1750_CR3","doi-asserted-by":"publisher","DOI":"10.3390\/cancers16020383","volume":"16","author":"PL Yip","year":"2024","unstructured":"Yip PL, You R, Chen MY et al (2024) Embracing personalized strategies in radiotherapy for nasopharyngeal carcinoma: beyond the conventional bounds of fields and borders. Cancers 16(2):383. https:\/\/doi.org\/10.3390\/cancers16020383","journal-title":"Cancers"},{"issue":"1","key":"1750_CR4","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1186\/s13014-022-02059-6","volume":"17","author":"Y Xu","year":"2022","unstructured":"Xu Y, Xu Y, Men K et al (2022) Application of piecewise VMAT technique to whole-brain radiotherapy with simultaneous integrated boost for multiple metastases. Radiat Oncol 17(1):86. https:\/\/doi.org\/10.1186\/s13014-022-02059-6","journal-title":"Radiat Oncol"},{"key":"1750_CR5","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2023.1195266","volume":"13","author":"Y Wang","year":"2023","unstructured":"Wang Y, Shen J, Gu P et al (2023) Recent advances progress in radiotherapy for breast cancer after breast-conserving surgery: a review. Front Oncol 13:1195266. https:\/\/doi.org\/10.3389\/fonc.2023.1195266","journal-title":"Front Oncol"},{"issue":"Suppl 2","key":"1750_CR6","doi-asserted-by":"publisher","first-page":"S731","DOI":"10.4103\/jcrt.jcrt29822","volume":"19","author":"BC Bicakci","year":"2023","unstructured":"Bicakci BC, Demircioglu F, Can SSN et al (2023) Optimal plan target in cases with locally advanced nasopharyngeal cancer: comparison of VMAT, IMRT, hybrid, and tomotherapy results. J Cancer Res Ther 19(Suppl 2):S731\u2013S736. https:\/\/doi.org\/10.4103\/jcrt.jcrt29822","journal-title":"J Cancer Res Ther"},{"key":"1750_CR7","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2021.646584","volume":"11","author":"Q Wang","year":"2021","unstructured":"Wang Q, Qin J, Cao R et al (2021) Comparison of dosimetric benefits of three precise radiotherapy techniques in nasopharyngeal carcinoma patients using a priority-classified plan optimization model. Front Oncol 11:646584. https:\/\/doi.org\/10.3389\/fonc.2021.646584","journal-title":"Front Oncol"},{"issue":"2","key":"1750_CR8","doi-asserted-by":"publisher","first-page":"e14158","DOI":"10.1002\/acm2.14158","volume":"25","author":"H Enomoto","year":"2024","unstructured":"Enomoto H, Fujita Y, Matsumoto S et al (2024) Dosimetric impact of MLC positional errors on dose distribution in IMRT. J Appl Clin Med Phys 25(2):e14158. https:\/\/doi.org\/10.1002\/acm2.14158","journal-title":"J Appl Clin Med Phys"},{"issue":"9","key":"1750_CR9","doi-asserted-by":"publisher","first-page":"26","DOI":"10.4103\/jmss.jmss_42_23","volume":"14","author":"Z Pourparvar","year":"2024","unstructured":"Pourparvar Z, Shahbazi-Gahrouei D, Najafizade N et al (2024) Evaluation and comparison of the dose received by the mandible, maxilla, and teeth in two methods of three-dimensional conformal radiation therapy and helical tomotherapy. J Med Signals Sens 14(9):26. https:\/\/doi.org\/10.4103\/jmss.jmss_42_23","journal-title":"J Med Signals Sens"},{"issue":"21","key":"1750_CR10","doi-asserted-by":"publisher","DOI":"10.3390\/cancers13215404","volume":"13","author":"JE Van Timmeren","year":"2021","unstructured":"Van Timmeren JE, Chamberlain M, Bogowicz M et al (2021) MR-guided adaptive radiotherapy for head and neck cancer: prospective evaluation of migration and anatomical changes of the major salivary glands. Cancers 13(21):5404. https:\/\/doi.org\/10.3390\/cancers13215404","journal-title":"Cancers"},{"key":"1750_CR11","doi-asserted-by":"publisher","DOI":"10.1016\/j.knosys.2023.110549","volume":"271","author":"W Liu","year":"2023","unstructured":"Liu W, Zhang L, Xie L et al (2023) Multilayer perceptron neural network with regression and ranking loss for patient-specific quality assurance. Knowl Based Syst 271:110549. https:\/\/doi.org\/10.1016\/j.knosys.2023.110549","journal-title":"Knowl Based Syst"},{"key":"1750_CR12","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1016\/j.ejmp.2021.02.025","volume":"84","author":"H Alhamada","year":"2021","unstructured":"Alhamada H, Simon S, Gulyban A et al (2021) Monte Carlo as quality control tool of stereotactic body radiation therapy treatment plans. Phys Med 84:205\u2013213. https:\/\/doi.org\/10.1016\/j.ejmp.2021.02.025","journal-title":"Phys Med"},{"key":"1750_CR13","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1016\/j.ejmp.2019.10.029","volume":"67","author":"S Diamantopoulos","year":"2019","unstructured":"Diamantopoulos S, Platoni K, Patatoukas G et al (2019) Treatment plan verification: a review on the comparison of dose distributions. Phys Med 67:107\u2013115. https:\/\/doi.org\/10.1016\/j.ejmp.2019.10.029","journal-title":"Phys Med"},{"issue":"1","key":"1750_CR14","doi-asserted-by":"publisher","DOI":"10.1186\/s13014-022-02097-0","volume":"17","author":"X Lin","year":"2022","unstructured":"Lin X, Sun T, Liu X et al (2022) Comparison of MLC positioning deviations using log files and establishment of specific assessment parameters for different accelerators with IMRT and VMAT. Radiat Oncol 17(1):123. https:\/\/doi.org\/10.1186\/s13014-022-02097-0","journal-title":"Radiat Oncol"},{"issue":"4","key":"1750_CR15","doi-asserted-by":"publisher","first-page":"1982","DOI":"10.1118\/1.4943953","volume":"43","author":"JM Steers","year":"2016","unstructured":"Steers JM, Fraass BA (2016) IMRT QA: selecting gamma criteria based on error detection sensitivity. Med Phys 43(4):1982\u20131994. https:\/\/doi.org\/10.1118\/1.4943953","journal-title":"Med Phys"},{"issue":"1","key":"1750_CR16","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1120\/jacmp.v16i1.4814","volume":"16","author":"AK Templeton","year":"2015","unstructured":"Templeton AK, Chu JCH, Turian JV (2015) The sensitivity of ArcCHECK-based gamma analysis to manufactured errors in helical tomotherapy radiation delivery. J Appl Clin Med Phys 16(1):32\u201339. https:\/\/doi.org\/10.1120\/jacmp.v16i1.4814","journal-title":"J Appl Clin Med Phys"},{"issue":"11","key":"1750_CR17","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1002\/acm2.13051","volume":"21","author":"P Szeverinski","year":"2020","unstructured":"Szeverinski P, Kowatsch M, K\u00fcnzler T et al (2020) Error sensitivity of a log file analysis tool compared with a helical diode array dosimeter for VMAT delivery quality assurance. J Appl Clin Med Phys 21(11):163\u2013171. https:\/\/doi.org\/10.1002\/acm2.13051","journal-title":"J Appl Clin Med Phys"},{"issue":"3","key":"1750_CR18","doi-asserted-by":"publisher","first-page":"S44","DOI":"10.1016\/j.ijrobp.2020.07.2157","volume":"108","author":"V Vasudevan","year":"2020","unstructured":"Vasudevan V, Huang C, Simiele E et al (2020) Combining Monte Carlo with deep learning: predicting high-resolution, low-noise dose distributions using a generative adversarial network for fast and precise Monte Carlo simulations. Int J Radiat Oncol Biol Phys 108(3):S44\u2013S45. https:\/\/doi.org\/10.1016\/j.ijrobp.2020.07.2157","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"6","key":"1750_CR19","doi-asserted-by":"publisher","first-page":"1195","DOI":"10.1007\/s13534-024-00423-x","volume":"14","author":"H Lee","year":"2024","unstructured":"Lee H (2024) Monte Carlo methods for medical imaging research. Biomed Eng Lett 14(6):1195\u20131205. https:\/\/doi.org\/10.1007\/s13534-024-00423-x","journal-title":"Biomed Eng Lett"},{"key":"1750_CR20","doi-asserted-by":"publisher","DOI":"10.1017\/S1460396923000079","volume":"22","author":"AL Fielding","year":"2023","unstructured":"Fielding AL (2023) Monte-Carlo techniques for radiotherapy applications I: introduction and overview of the different Monte-Carlo codes. J Radiother Pract 22:e80. https:\/\/doi.org\/10.1017\/S1460396923000079","journal-title":"J Radiother Pract"},{"issue":"4","key":"1750_CR21","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1002\/acm2.13209","volume":"22","author":"S Piffer","year":"2021","unstructured":"Piffer S, Casati M, Marrazzo L et al (2021) Validation of a secondary dose check tool against Monte Carlo and analytical clinical dose calculation algorithms in VMAT. J Appl Clin Med Phys 22(4):52\u201362. https:\/\/doi.org\/10.1002\/acm2.13209","journal-title":"J Appl Clin Med Phys"},{"issue":"10","key":"1750_CR22","doi-asserted-by":"publisher","DOI":"10.1118\/1.4894721","volume":"41","author":"LL Handsfield","year":"2014","unstructured":"Handsfield LL, Jones R, Wilson DD et al (2014) Phantomless patient-specific TomoTherapy QA via delivery performance monitoring and a secondary Monte Carlo dose calculation. Med Phys 41(10):101703. https:\/\/doi.org\/10.1118\/1.4894721","journal-title":"Med Phys"},{"issue":"1","key":"1750_CR23","doi-asserted-by":"publisher","DOI":"10.1186\/s13014-020-01669-2","volume":"15","author":"R Thiyagarajan","year":"2020","unstructured":"Thiyagarajan R, Sharma DS, Kaushik S et al (2020) Leaf open time sinogram (LOTS): a novel approach for patient specific quality assurance of total marrow irradiation. Radiat Oncol 15(1):236","journal-title":"Radiat Oncol"},{"issue":"6","key":"1750_CR24","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1002\/acm2.12480","volume":"19","author":"E Chung","year":"2018","unstructured":"Chung E, Kwon D, Park T et al (2018) Clinical implementation of Dosimetry Check\u2122 for TomoTherapy\u00ae delivery quality assurance. J Appl Clin Med Phys 19(6):193\u2013199. https:\/\/doi.org\/10.1002\/acm2.12480","journal-title":"J Appl Clin Med Phys"},{"key":"1750_CR25","doi-asserted-by":"crossref","unstructured":"Etemadi G, Mostaar A, Azadeh P, et al (2025) Feasibility of patient quality assurance method based on log file and onboard detector in helical tomotherapy technique. Front Biomed Technol","DOI":"10.18502\/fbt.v13i2.21939"},{"issue":"5","key":"1750_CR26","doi-asserted-by":"publisher","first-page":"3172","DOI":"10.1002\/mp.16337","volume":"50","author":"B Cheng","year":"2023","unstructured":"Cheng B, Xu Y, Li S et al (2023) Development and clinical application of a GPU\u2010based Monte Carlo dose verification module and software for 1.5 T MR\u2010LINAC. Med Phys 50(5):3172\u20133183. https:\/\/doi.org\/10.1002\/mp.16337","journal-title":"Med Phys"},{"issue":"2","key":"1750_CR27","doi-asserted-by":"publisher","first-page":"e14175","DOI":"10.1002\/acm2.14175","volume":"25","author":"Y Xu","year":"2024","unstructured":"Xu Y, Xia W, Ren W et al (2024) Is it necessary to perform measurement-based patient-specific quality assurance for online adaptive radiotherapy with Elekta Unity MR-Linac? J Appl Clin Med Phys 25(2):e14175. https:\/\/doi.org\/10.1002\/acm2.14175","journal-title":"J Appl Clin Med Phys"},{"issue":"2","key":"1750_CR28","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1120\/jacmp.v14i2.3929","volume":"14","author":"MH Lin","year":"2013","unstructured":"Lin MH, Koren S, Veltchev I et al (2013) Measurement comparison and Monte Carlo analysis for volumetric\u2010modulated arc therapy (VMAT) delivery verification using the ArcCHECK dosimetry system. J Appl Clin Med Phys 14(2):220\u2013233. https:\/\/doi.org\/10.1120\/jacmp.v14i2.3929","journal-title":"J Appl Clin Med Phys"},{"issue":"4","key":"1750_CR29","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1016\/j.brachy.2022.03.004","volume":"21","author":"A Cicho\u0144ski","year":"2022","unstructured":"Cicho\u0144ski A, Wysocka-Rabin A, Bulski W et al (2022) Validation of accordance of ArcCHECK diode detector output with Monte Carlo simulation in brachytherapy. Brachytherapy 21(4):543\u2013550. https:\/\/doi.org\/10.1016\/j.brachy.2022.03.004","journal-title":"Brachytherapy"},{"key":"1750_CR30","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2025.110934","author":"P Wall","year":"2025","unstructured":"Wall P, Tucker W, Mazur T et al (2025) Clinical validation of statistical predictive model for patient-specific quality assurance outcomes in stereotactic radiotherapy using secondary Monte Carlo dose calculations. Radiother Oncol. https:\/\/doi.org\/10.1016\/j.radonc.2025.110934","journal-title":"Radiother Oncol"},{"key":"1750_CR31","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2022.1051110","volume":"12","author":"Y Xu","year":"2022","unstructured":"Xu Y, Zhang K, Liu Z et al (2022) Treatment plan prescreening for patient-specific quality assurance measurements using independent Monte Carlo dose calculations. Front Oncol 12:1051110. https:\/\/doi.org\/10.3389\/fonc.2022.1051110","journal-title":"Front Oncol"},{"key":"1750_CR32","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2025.1509449","volume":"15","author":"J Miao","year":"2025","unstructured":"Miao J, Xu Y, Men K et al (2025) A feasibility study of deep learning prediction model for VMAT patient-specific QA. Front Oncol 15:1509449. https:\/\/doi.org\/10.3389\/fonc.2025.1509449","journal-title":"Front Oncol"},{"issue":"11","key":"1750_CR33","doi-asserted-by":"publisher","first-page":"1195","DOI":"10.1002\/cac2.12218","volume":"41","author":"LL Tang","year":"2021","unstructured":"Tang LL, Chen YP, Chen CB et al (2021) The Chinese Society of Clinical Oncology (CSCO) clinical guidelines for the diagnosis and treatment of nasopharyngeal carcinoma. Cancer Commun 41(11):1195\u20131227. https:\/\/doi.org\/10.1002\/cac2.12218","journal-title":"Cancer Commun"},{"issue":"1","key":"1750_CR34","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1007\/s00066-011-0015-x","volume":"188","author":"N Hodapp","year":"2012","unstructured":"Hodapp N (2012) The ICRU Report 83: prescribing, recording and reporting photon-beam intensity-modulated radiation therapy (IMRT). Strahlenther Onkol 188(1):97\u201399. https:\/\/doi.org\/10.1007\/s00066-011-0015-x","journal-title":"Strahlenther Onkol"},{"issue":"1","key":"1750_CR35","doi-asserted-by":"publisher","DOI":"10.1186\/s12885-025-14086-z","volume":"25","author":"XL Yang","year":"2025","unstructured":"Yang XL, Lin L, He SS et al (2025) Nasopharyngeal necrosis following intensity-modulated radiation therapy of primary nasopharyngeal carcinoma\u2014incidence rate and predictors of risk. BMC Cancer 25(1):802. https:\/\/doi.org\/10.1186\/s12885-025-14086-z","journal-title":"BMC Cancer"},{"key":"1750_CR36","doi-asserted-by":"publisher","DOI":"10.1016\/j.zemedi.2023.10.001","author":"M Kowatsch","year":"2023","unstructured":"Kowatsch M, Szeverinski P, Clemens P et al (2023) Sensitivity and specificity of Monte Carlo based independent secondary dose computation for detecting modulation-related dose errors in intensity modulated radiotherapy. Z Med Phys. https:\/\/doi.org\/10.1016\/j.zemedi.2023.10.001","journal-title":"Z Med Phys"},{"issue":"4","key":"1750_CR37","doi-asserted-by":"publisher","first-page":"e53","DOI":"10.1002\/mp.12810","volume":"45","author":"M Miften","year":"2018","unstructured":"Miften M, Olch A, Mihailidis D et al (2018) Tolerance limits and methodologies for IMRT measurement-based verification QA: recommendations of AAPM Task Group No. 218. Med Phys 45(4):e53\u2013e83. https:\/\/doi.org\/10.1002\/mp.12810","journal-title":"Med Phys"},{"issue":"4","key":"1750_CR38","doi-asserted-by":"publisher","DOI":"10.3390\/bioengineering9040131","volume":"9","author":"Z Ding","year":"2022","unstructured":"Ding Z, Zeng Q, Kang K et al (2022) Evaluation of plan robustness using hybrid intensity-modulated radiotherapy (IMRT) and volumetric arc modulation radiotherapy (VMAT) for left-sided breast cancer. Bioengineering 9(4):131. https:\/\/doi.org\/10.3390\/bioengineering9040131","journal-title":"Bioengineering"},{"issue":"4","key":"1750_CR39","doi-asserted-by":"publisher","first-page":"893","DOI":"10.1016\/j.ijrobp.2019.07.049","volume":"105","author":"J Li","year":"2019","unstructured":"Li J, Wang LE, Zhang X et al (2019) Machine learning for patient-specific quality assurance of VMAT: prediction and classification accuracy. Int J Radiat Oncol Biol Phys 105(4):893\u2013902. https:\/\/doi.org\/10.1016\/j.ijrobp.2019.07.049","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"1750_CR40","doi-asserted-by":"publisher","DOI":"10.1016\/j.radphyschem.2023.111236","volume":"213","author":"S Poudel","year":"2023","unstructured":"Poudel S, Kulshreshtha A, Zakaria GA et al (2023) Monte Carlo calculations of dose profiles with the \u2018given profile\u201d method and comparison with measurements. Radiat Phys Chem 213:111236. https:\/\/doi.org\/10.1016\/j.radphyschem.2023.111236","journal-title":"Radiat Phys Chem"},{"issue":"4","key":"1750_CR41","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1120\/jacmp.v15i4.4832","volume":"15","author":"V Chaswal","year":"2014","unstructured":"Chaswal V, Weldon M, Gupta N et al (2014) Commissioning and comprehensive evaluation of the ArcCHECK cylindrical diode array for VMAT pretreatment delivery QA. J Appl Clin Med Phys 15(4):212\u2013225. https:\/\/doi.org\/10.1120\/jacmp.v15i4.4832","journal-title":"J Appl Clin Med Phys"},{"issue":"3","key":"1750_CR42","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1016\/j.meddos.2014.04.004","volume":"39","author":"E Infusino","year":"2014","unstructured":"Infusino E, Mameli A, Conti R et al (2014) Initial experience of ArcCHECK and 3DVH software for RapidArc treatment plan verification. Med Dosim 39(3):276\u2013281. https:\/\/doi.org\/10.1016\/j.meddos.2014.04.004","journal-title":"Med Dosim"},{"issue":"10","key":"1750_CR43","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1002\/acm2.13409","volume":"22","author":"A J\u00e4ger","year":"2021","unstructured":"J\u00e4ger A, Wegener S, Sauer OA (2021) Dose rate correction for a silicon diode detector array. J Appl Clin Med Phys 22(10):144\u2013151. https:\/\/doi.org\/10.1002\/acm2.13409","journal-title":"J Appl Clin Med Phys"},{"issue":"1","key":"1750_CR44","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1186\/s13014-022-02151-x","volume":"17","author":"C Kim","year":"2022","unstructured":"Kim C, Han MC, Lee YK et al (2022) Comprehensive clinical evaluation of TomoEQA for patient-specific pre-treatment quality assurance in helical tomotherapy. Radiat Oncol 17(1):177. https:\/\/doi.org\/10.1186\/s13014-022-02151-x","journal-title":"Radiat Oncol"},{"key":"1750_CR45","doi-asserted-by":"publisher","DOI":"10.1177\/15330338231175781","volume":"22","author":"YH Yoon","year":"2023","unstructured":"Yoon YH, Shin HB, Han MC et al (2023) Development of automated delivery quality assurance analysis software for helical tomotherapy. Technol Cancer Res Treat 22:15330338231175781. https:\/\/doi.org\/10.1177\/15330338231175781","journal-title":"Technol Cancer Res Treat"},{"issue":"6","key":"1750_CR46","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1002\/acm2.13221","volume":"22","author":"T Alharthi","year":"2021","unstructured":"Alharthi T, Vial P, Holloway L et al (2021) Intrinsic detector sensitivity analysis as a tool to characterize ArcCHECK and EPID sensitivity to variations in delivery for lung SBRT VMAT plans. J Appl Clin Med Phys 22(6):229\u2013240. https:\/\/doi.org\/10.1002\/acm2.13221","journal-title":"J Appl Clin Med Phys"},{"issue":"5","key":"1750_CR47","doi-asserted-by":"publisher","first-page":"793","DOI":"10.5603\/RPOR.a2021.0093","volume":"26","author":"A Gray","year":"2021","unstructured":"Gray A, Bawazeer O, Arumugam S et al (2021) Evaluation of the ability of three commercially available dosimeters to detect systematic delivery errors in step-and-shoot IMRT plans. Rep Pract Oncol Radiother 26(5):793\u2013803. https:\/\/doi.org\/10.5603\/RPOR.a2021.0093","journal-title":"Rep Pract Oncol Radiother"},{"issue":"7","key":"1750_CR48","doi-asserted-by":"publisher","first-page":"720","DOI":"10.1016\/j.ejmp.2015.05.016","volume":"31","author":"L Vieillevigne","year":"2015","unstructured":"Vieillevigne L, Molinier J, Brun T et al (2015) Gamma index comparison of three VMAT QA systems and evaluation of their sensitivity to delivery errors. Phys Med 31(7):720\u2013725. https:\/\/doi.org\/10.1016\/j.ejmp.2015.05.016","journal-title":"Phys Med"},{"issue":"12","key":"1750_CR49","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.14139","volume":"24","author":"S Wegener","year":"2023","unstructured":"Wegener S, Abu Rashed R, Sauer OA et al (2023) Sensitivity and specificity of secondary dose calculation for head and neck treatment plans. J Appl Clin Med Phys 24(12):e14139. https:\/\/doi.org\/10.1002\/acm2.14139","journal-title":"J Appl Clin Med Phys"}],"container-title":["Physical and Engineering Sciences in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-026-01750-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s13246-026-01750-2","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-026-01750-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T23:07:12Z","timestamp":1791241632000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s13246-026-01750-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,8]]},"references-count":49,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,9]]}},"alternative-id":["1750"],"URL":"https:\/\/doi.org\/10.1007\/s13246-026-01750-2","relation":{},"ISSN":["2662-4729","2662-4737"],"issn-type":[{"value":"2662-4729","type":"print"},{"value":"2662-4737","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,8]]},"assertion":[{"value":"14 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study protocol was reviewed and approved by the institutional review board of Jiangxi Cancer Hospital [Approval No. 2025ky129].","order":2,"name":"Ethics","label":"Ethics approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The requirement for informed consent was waived owing to the retrospective nature of the study, and all patient data were de-identified before analysis.","order":3,"name":"Ethics","label":"Informed consent","group":{"name":"EthicsHeading","label":"Declarations"}}]}}