{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T15:23:06Z","timestamp":1787844186344,"version":"build-2784847793"},"reference-count":59,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T00:00:00Z","timestamp":1787788800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T00:00:00Z","timestamp":1787788800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Phys Eng Sci Med"],"DOI":"10.1007\/s13246-026-01798-0","type":"journal-article","created":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T15:13:33Z","timestamp":1787843613000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Ultrasound swallowing assessment: the impact of image post-processing on measurement reliability"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2739-1684","authenticated-orcid":false,"given":"Katharina","family":"Winiker","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sruthy","family":"Vijayan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alan","family":"Brook","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8806-7116","authenticated-orcid":false,"given":"Maggie-Lee","family":"Huckabee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,27]]},"reference":[{"key":"1798_CR1","doi-asserted-by":"crossref","unstructured":"Jean A (2001) \/03\/29 Brain stem control of swallowing: Neuronal network and cellular mechanisms. Physiol Rev. 2001;81(2):929\u2013969","DOI":"10.1152\/physrev.2001.81.2.929"},{"key":"1798_CR2","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1007\/978-1-4614-3794-9_5","volume-title":"Principles of deglutition A multidisciplinary text for swallowing and its disorder","author":"DH Vasant","year":"2013","unstructured":"Vasant DH, Hamdy S (2013) Cerebral cortical control of deglutition. In: Shaker R, Belafsky P, Postma G et al (eds) Principles of deglutition A multidisciplinary text for swallowing and its disorder. Springer, New York, 55\u201365"},{"issue":"1","key":"1798_CR3","doi-asserted-by":"publisher","first-page":"486","DOI":"10.1044\/2021_AJSLP-21-00249","volume":"31","author":"D Rangira","year":"2022","unstructured":"Rangira D, Najeeb H, Shune SE et al (2022) Understanding Burden in Caregivers of Adults With Dysphagia: A Systematic Review. Am J Speech Lang Pathol 31(1):486\u2013501","journal-title":"Am J Speech Lang Pathol"},{"key":"1798_CR4","doi-asserted-by":"crossref","unstructured":"Rivelsrud MC, Hartelius L, Bergstr\u00f6m L et al (2022) Prevalence of Oropharyngeal Dysphagia in Adults in Different Healthcare Settings: A Systematic Review and Meta-analyses. Dysphagia","DOI":"10.1007\/s00455-022-10465-x"},{"issue":"2S","key":"1798_CR5","doi-asserted-by":"publisher","first-page":"919","DOI":"10.1044\/2020_AJSLP-19-00063","volume":"29","author":"KL Garand","year":"2020","unstructured":"Garand KL, McCullough G, Crary M et al (2020) Assessment across the life span: The clinical swallow evaluation. Am J Speech Lang Pathol 29(2S):919\u2013933","journal-title":"Am J Speech Lang Pathol"},{"key":"1798_CR6","doi-asserted-by":"publisher","DOI":"10.1007\/s00455-021-10283-7","author":"R Speyer","year":"2021","unstructured":"Speyer R, Cordier R, Farneti D et al (2021) White paper by the European Society for Swallowing Disorders: Screening and non-instrumental assessment for dysphagia in adults. Dysphagia. https:\/\/doi.org\/10.1007\/s00455-021-10283-7","journal-title":"Dysphagia"},{"issue":"3","key":"1798_CR7","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1097\/MOO.0000000000000708","volume":"29","author":"JE Allen","year":"2021","unstructured":"Allen JE, Clunie GM, Winiker K (2021) Ultrasound: An emerging modality for the dysphagia assessment toolkit? Curr Opin Otolaryngol Head Neck Surg 29(3):213\u2013218","journal-title":"Curr Opin Otolaryngol Head Neck Surg"},{"key":"1798_CR8","doi-asserted-by":"crossref","unstructured":"Hsiao MY, Wu CH, Wang TG (2021) Emerging Role of Ultrasound in Dysphagia Assessment and Intervention: A Narrative Review. Frontiers in Rehabilitation Sciences","DOI":"10.3389\/fresc.2021.708102"},{"key":"1798_CR9","doi-asserted-by":"crossref","unstructured":"Maeda K, Nagasaka M, Nagano A et al (2023) Ultrasonography for Eating and Swallowing Assessment: A Narrative Review of Integrated Insights for Noninvasive Clinical Practice. Nutrients 15:3560","DOI":"10.3390\/nu15163560"},{"key":"1798_CR10","volume-title":"Evaluation and treatment of swallowing disorders","author":"JA Logemann","year":"1998","unstructured":"Logemann JA (1998) Evaluation and treatment of swallowing disorders, 2nd edn. pro-ed, Texas, United States of America","edition":"2"},{"issue":"6","key":"1798_CR11","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1159\/000444636","volume":"67","author":"ML Huckabee","year":"2015","unstructured":"Huckabee ML, Macrae P, Lamvik K (2015) Expanding Instrumental Options for Dysphagia Diagnosis and Research: Ultrasound and Manometry. Folia Phoniatr et Logopaedica 67(6):269\u2013284","journal-title":"Folia Phoniatr et Logopaedica [Internet]"},{"key":"1798_CR12","doi-asserted-by":"crossref","unstructured":"Sikdar S, Wei Q, Cortes N (2014) Dynamic Ultrasound Imaging Applications to Quantify Musculoskeletal Function. Sport Sci Rev","DOI":"10.1249\/JES.0000000000000015"},{"issue":"6\u20137","key":"1798_CR13","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1080\/02699200500113558","volume":"19","author":"M Stone","year":"2005","unstructured":"Stone M (2005) A guide to analysing tongue motion from ultrasound images. Clin Linguist Phon 19(6\u20137):455\u2013501","journal-title":"Clin Linguist Phon [Internet]"},{"issue":"1","key":"1798_CR14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-020-71378-z","volume":"10","author":"PH Chang","year":"2020","unstructured":"Chang PH, Chen YJ, Chang KV et al (2020) Ultrasound measurements of superficial and deep masticatory muscles in various postures: reliability and influencers. Sci Rep 10(1):1\u20139","journal-title":"Sci Rep"},{"key":"1798_CR15","doi-asserted-by":"publisher","unstructured":"Andrade RAde, do Sales Coriolano MdasGW, de Souza ELH et al (2022) Reliability of Ultrasound Examination of Hyoid Bone Displacement Amplitude: A Systematic Review and Meta-Analysis. Dysphagia https:\/\/doi.org\/10.1007\/s00455-022-10429-1","DOI":"10.1007\/s00455-022-10429-1"},{"issue":"8","key":"1798_CR16","doi-asserted-by":"publisher","first-page":"2928","DOI":"10.1044\/2021_JSLHR-21-00026","volume":"64","author":"K Winiker","year":"2021","unstructured":"Winiker K, Burnip E, Gozdzikowska K et al (2021) Ultrasound: Reliability of a pocket-sized system in the assessment of swallowing. J Speech Lang Hear Res 64(8):2928\u20132940","journal-title":"J Speech Lang Hear Res"},{"issue":"3","key":"1798_CR17","doi-asserted-by":"publisher","first-page":"539","DOI":"10.1111\/1460-6984.12703","volume":"57","author":"K Winiker","year":"2022","unstructured":"Winiker K, Hammond R, Thomas P et al (2022) Swallowing assessment in patients with dysphagia: Validity and reliability of a pocket-sized ultrasound system. Int J Lang Commun Disord 57(3):539\u2013551","journal-title":"Int J Lang Commun Disord"},{"issue":"4","key":"1798_CR18","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1002\/ajhb.1310040410","volume":"4","author":"Y Ishida","year":"1992","unstructured":"Ishida Y, Carroll JF, Pollock ML et al (1992) Reliability of B-Mode ultrasound for the measurement of body-fat and muscle thickness. Am J Hum Biology 4(4):511\u2013520","journal-title":"Am J Hum Biology"},{"issue":"6\u20137","key":"1798_CR19","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1080\/02699200500113558","volume":"19","author":"M Stone","year":"2005","unstructured":"Stone M (2005) A guide to analysing tongue motion from ultrasound images. Clin Linguist Phon 19(6\u20137):455\u2013501","journal-title":"Clin Linguist Phon"},{"issue":"1","key":"1798_CR20","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1530\/ERP-17-0047","volume":"5","author":"Y Nagata","year":"2018","unstructured":"Nagata Y, Kado Y, Onoue T et al (2018) Impact of image quality on reliability of the measurements of left ventricular systolic function and global longitudinal strain in 2D echocardiography. Echo Res Pract 5(1):27\u201339","journal-title":"Echo Res Pract"},{"key":"1798_CR21","doi-asserted-by":"crossref","unstructured":"Wilke L, Abellan Schneyder FE, Roskopf M et al (2018) Speckle tracking stress echocardiography in children: Interobserver and intraobserver reproducibility and the impact of echocardiographic image quality. Sci Rep 8(1):1\u201312","DOI":"10.1038\/s41598-018-27412-2"},{"issue":"1","key":"1798_CR22","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1109\/TBME.2019.2912986","volume":"67","author":"Z Zhou","year":"2019","unstructured":"Zhou Z, Wang Y, Guo Y et al (2019) Image Quality Improvement of Hand-Held Ultrasound Devices With a Two-Stage Generative Adversarial Network. IEEE Trans Biomed Eng 67(1):298\u2013311","journal-title":"IEEE Trans Biomed Eng"},{"issue":"7","key":"1798_CR23","doi-asserted-by":"publisher","first-page":"778","DOI":"10.1197\/j.aem.2003.12.030","volume":"11","author":"M Blaivas","year":"2004","unstructured":"Blaivas M, Brannam L, Theodoro D (2004) Ultrasound image quality comparison between an inexpensive handheld emergency department (ED) ultrasound machine and a large mobile ED ultrasound system. Acad Emerg Med 11(7):778\u2013781","journal-title":"Acad Emerg Med"},{"key":"1798_CR24","unstructured":"Ragesh NK, Anil AR, Rajesh R (2011) Digital Image Denoising in Medical Ultrasound Images: A Survey"},{"issue":"3","key":"1798_CR25","doi-asserted-by":"publisher","first-page":"470","DOI":"10.1109\/TUFFC.2016.2526670","volume":"63","author":"A Perperidis","year":"2016","unstructured":"Perperidis A (2016) Postprocessing Approaches for the Improvement of Cardiac Ultrasound B-Mode Images: A Review. IEEE Trans Ultrason Ferroelectr Freq Control 63(3):470\u2013485","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"key":"1798_CR26","doi-asserted-by":"crossref","unstructured":"Michailovich OV, Tannenbaum A (2006) Despeckling of Medical Ultrasound Images. IEEE Trans Ultrason Ferroelectr Freq Control","DOI":"10.1109\/TUFFC.2006.1588392"},{"key":"1798_CR27","doi-asserted-by":"crossref","unstructured":"Mitchell C, Korcarz CE, Zagzebski JA et al (2021) Effects of ultrasound technology advances on measurement of carotid intima\u2013media thickness: A review. Vascular Medicine 26(1):81\u201385","DOI":"10.1177\/1358863X20969826"},{"issue":"6","key":"1798_CR28","doi-asserted-by":"publisher","first-page":"2277","DOI":"10.1109\/TMI.2020.2970867","volume":"39","author":"O Huang","year":"2020","unstructured":"Huang O, Long W, Bottenus N et al (2020) MimickNet, Mimicking Clinical Image Post- Processing under Black-Box Constraints. IEEE Trans Med Imaging 39(6):2277\u20132286","journal-title":"IEEE Trans Med Imaging"},{"issue":"5","key":"1798_CR29","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1016\/j.bspc.2012.02.002","volume":"7","author":"SH Contreras Ortiz","year":"2012","unstructured":"Contreras Ortiz SH, Chiu T, Fox MD (2012) Ultrasound image enhancement: A review. Biomed Signal Process Control 7(5):419\u2013428","journal-title":"Biomed Signal Process Control"},{"issue":"1","key":"1798_CR30","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1097\/JCE.0000000000000378","volume":"45","author":"ZA Mustafa","year":"2020","unstructured":"Mustafa ZA, Abrahim BA, Omara A et al (2020) Reduction of Speckle Noise and Image Enhancement in Ultrasound Image Using Filtering Technique and Edge Detection. J Clin Eng 45(1):51\u201365","journal-title":"J Clin Eng"},{"key":"1798_CR31","unstructured":"Ali M, Magee D, Dasgupta U (2008) Signal Processing Overview of Ultrasound Systems for Medical Imaging"},{"issue":"9","key":"1798_CR32","doi-asserted-by":"publisher","first-page":"1889","DOI":"10.7863\/ultra.15.04065","volume":"35","author":"S Koppaka","year":"2016","unstructured":"Koppaka S, Shklyar I, Rutkove SB et al (2016) Quantitative ultrasound assessment of duchenne muscular dystrophy using edge detection analysis. J Ultrasound Med 35(9):1889\u20131897","journal-title":"J Ultrasound Med"},{"key":"1798_CR33","doi-asserted-by":"crossref","unstructured":"Torres HR, Morais P, Oliveira B et al (2022) A review of image processing methods for fetal head and brain analysis in ultrasound images. Comput. Methods Programs Biomed 215","DOI":"10.1016\/j.cmpb.2022.106629"},{"key":"1798_CR34","unstructured":"Miura Y, Nakagami G, Yabunaka K et al Method for detecting aspiration based on image processing-assisted B-mode video ultrasonography"},{"issue":"6","key":"1798_CR35","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1016\/j.ijnurstu.2011.01.016","volume":"48","author":"J Kottner","year":"2011","unstructured":"Kottner J, Audige L, Brorson S et al (2011) Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed. Int J Nurs Stud 48(6):661\u2013671","journal-title":"Int J Nurs Stud"},{"issue":"2","key":"1798_CR36","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1002\/jcu.20874","volume":"40","author":"PR Macrae","year":"2012","unstructured":"Macrae PR, Doeltgen SH, Jones RD et al (2012) Intra- and inter-rater reliability for analysis of hyoid displacement measured with sonography. J Clin Ultrasound 40(2):74\u201378","journal-title":"J Clin Ultrasound [Internet]"},{"issue":"4","key":"1798_CR37","doi-asserted-by":"publisher","first-page":"943","DOI":"10.1007\/s40477-025-01069-w","volume":"28","author":"S Ishino","year":"2025","unstructured":"Ishino S, Nagasaka M, Kawamura K et al (2025) Intra- and inter-rater reliability of swallowing-related muscle assessments using ultrasound devices. J Ultrasound 28(4):943\u2013952","journal-title":"J Ultrasound"},{"key":"1798_CR38","doi-asserted-by":"publisher","first-page":"208","DOI":"10.5201\/ipol.2011.bcm_nlm","volume":"1","author":"A Buades","year":"2011","unstructured":"Buades A, Coll B, Morel J-M (2011) Non-Local Means Denoising. Image Process Line 1:208\u2013212","journal-title":"Image Process Line"},{"key":"1798_CR39","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1016\/S0031-3203(00)00023-6","volume":"34","author":"L Ding","year":"2001","unstructured":"Ding L, Goshtasby A (2001) On the Canny edge detector. Pattern Recognit 34:721\u2013725","journal-title":"Pattern Recognit"},{"issue":"7","key":"1798_CR40","first-page":"1502","volume":"27","author":"Y Zhang","year":"2017","unstructured":"Zhang Y, Li X, Gao X et al (2017) A Simple Algorithm of Superpixel Segmentation with Boundary Constraint. IEEE Trans Circuits Syst Video Technol 27(7):1502\u20131514","journal-title":"IEEE Trans Circuits Syst Video Technol"},{"issue":"3","key":"1798_CR41","first-page":"2295","volume":"6","author":"A Seal","year":"2015","unstructured":"Seal A, Das A, Sen P (2015) Watershed: An Image Segmentation Approach. Int J Comput Sci Inform Technol 6(3):2295\u20132297","journal-title":"Int J Comput Sci Inform Technol"},{"key":"1798_CR42","unstructured":"De Mello CAB (2011) Digital Document Analysis and Processing"},{"key":"1798_CR43","unstructured":"Portney LG, Watkins MP, Sydney, Singapore, Hong Kong, de Toronto SA (2009) C.V, Tokyo, Malaysia, New Jersey: Pearson Education"},{"issue":"3","key":"1798_CR44","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1093\/ejechocard\/jer021","volume":"12","author":"V Mor-Avi","year":"2011","unstructured":"Mor-Avi V, Lang RM, Badano LP et al (2011) Current and evolving echocardiographic techniques for the quantitative evaluation of cardiac mechanics: ASE\/EAE consensus statement on methodology and indications endorsed by the Japanese society of echocardiography. Eur J Echocardiography 12(3):167\u2013205","journal-title":"Eur J Echocardiography"},{"key":"1798_CR45","doi-asserted-by":"crossref","unstructured":"Shin Y, Yang J, Lee YH et al (2021) Artificial intelligence in musculoskeletal ultrasound imaging. Ultrasonography. Korean Society of Ultrasound in Medicine, pp 30\u201344","DOI":"10.14366\/usg.20080"},{"key":"1798_CR46","doi-asserted-by":"crossref","unstructured":"Ardhianto P, Tsai JY, Lin CY et al (2021) A review of the challenges in deep learning for skeletal and smooth muscle ultrasound images. Appl Sci 11(9):2\u201314","DOI":"10.3390\/app11094021"},{"key":"1798_CR47","doi-asserted-by":"crossref","unstructured":"Komatsu M, Sakai A, Dozen A et al (2021) Towards clinical application of artificial intelligence in ultrasound imaging. Biomedicines. MDPI AG","DOI":"10.3390\/biomedicines9070720"},{"key":"1798_CR48","doi-asserted-by":"crossref","unstructured":"Micucci M, Iula A (2022) Recent Advances in Machine Learning Applied to Ultrasound Imaging. Electronics. MDPI","DOI":"10.3390\/electronics11111800"},{"issue":"1","key":"1798_CR49","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1016\/j.ultrasmedbio.2023.09.008","volume":"50","author":"K Barron","year":"2024","unstructured":"Barron K, Blaivas M, Blaivas L et al (2024) Bedside Ultrasound to Identify and Predict Severity of Dysphagia Following Ischemic Stroke: Human Versus Artificial Intelligence. Ultrasound Med Biol 50(1):99\u2013104","journal-title":"Ultrasound Med Biol"},{"key":"1798_CR50","doi-asserted-by":"crossref","unstructured":"Feng S, Shea QTK, Ng KY et al (2021) Automatic hyoid bone tracking in real-time ultrasound swallowing videos using deep learning based and correlation filter based trackers. Sensors 21(11):1\u201316","DOI":"10.3390\/s21113712"},{"key":"1798_CR51","doi-asserted-by":"crossref","unstructured":"Ashir A, Jerban S, Barr\u00e8re V et al (2023) Skeletal Muscle Assessment Using Quantitative Ultrasound: A Narrative Review. Sensors. MDPI","DOI":"10.3390\/s23104763"},{"issue":"3","key":"1798_CR52","doi-asserted-by":"publisher","first-page":"408","DOI":"10.1002\/mus.25513","volume":"56","author":"TG O\u2019brien","year":"2017","unstructured":"O\u2019brien TG, Cazares Gonzalez ML, Ghosh PS et al (2017) Reliability of a novel ultrasound system for gray-scale analysis of muscle. Muscle Nerve 56(3):408\u2013412","journal-title":"Muscle Nerve"},{"key":"1798_CR53","doi-asserted-by":"crossref","unstructured":"Gadour E, Awad A, Hassan Z et al (2024) Diagnostic and therapeutic role of endoscopic ultrasound in liver diseases: A systematic review and meta-analysis. World J. Gastroenterol. Baishideng Publishing Group Inc, pp 742\u2013758","DOI":"10.3748\/wjg.v30.i7.742"},{"key":"1798_CR54","doi-asserted-by":"crossref","unstructured":"Tarantini P, Cei F, Longhi F et al (2025) Heart at Hand: The Role of Point-of-Care Cardiac Ultrasound in Internal Medicine. J. Cardiovasc. Dev. Dis","DOI":"10.3390\/jcdd12100379"},{"issue":"6","key":"1798_CR55","doi-asserted-by":"publisher","first-page":"1107","DOI":"10.1002\/jum.15192","volume":"39","author":"AW Johnson","year":"2020","unstructured":"Johnson AW, Stoneman P, McClung MS et al (2020) Use of Cine Loops and Structural Landmarks in Ultrasound Image Processing Improves Reliability and Reduces Error in the Assessment of Foot and Leg Muscles. J Ultrasound Med 39(6):1107\u20131116","journal-title":"J Ultrasound Med"},{"issue":"5","key":"1798_CR56","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1016\/j.bspc.2012.02.002","volume":"7","author":"SH Contreras Ortiz","year":"2012","unstructured":"Contreras Ortiz SH, Chiu T, Fox MD (2012) Ultrasound image enhancement: A review. Biomed Signal Process Control 7(5):419\u2013428","journal-title":"Biomed Signal Process Control"},{"issue":"1","key":"1798_CR57","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1109\/TIP.2014.2371244","volume":"24","author":"G Ramos-Llord\u00e9n","year":"2015","unstructured":"Ramos-Llord\u00e9n G, Vegas-S\u00e1nchez-Ferrero G, Martin-Fernandez M et al (2015) Anisotropic diffusion filter with memory based on speckle statistics for ultrasound images. IEEE Trans Image Process 24(1):345\u2013358","journal-title":"IEEE Trans Image Process"},{"key":"1798_CR58","doi-asserted-by":"crossref","unstructured":"Bhute S, Mandal S, Guha D (2024) Speckle Noise Reduction in Ultrasound Images using Denoising Auto-encoder with Skip Connection","DOI":"10.1109\/SAUS61785.2024.10563715"},{"key":"1798_CR59","doi-asserted-by":"publisher","unstructured":"Bates D, M\u00e4chler M, Bolker B, Walker S (2015) Fitting linear mixedeffects models using [lme4]. J Statistical Softw 67:1\u201348. https:\/\/doi.org\/10.18637\/jss.v067.i0110.18637\/jss.v067.i01","DOI":"10.18637\/jss.v067.i0110.18637\/jss.v067.i01"}],"container-title":["Physical and Engineering Sciences in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-026-01798-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s13246-026-01798-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-026-01798-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T15:13:38Z","timestamp":1787843618000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s13246-026-01798-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,27]]},"references-count":59,"alternative-id":["1798"],"URL":"https:\/\/doi.org\/10.1007\/s13246-026-01798-0","relation":{},"ISSN":["2662-4729","2662-4737"],"issn-type":[{"value":"2662-4729","type":"print"},{"value":"2662-4737","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,27]]},"assertion":[{"value":"13 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 August 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was performed in line with the principles of the Declaration of Helsinki. Approval was granted by the relevant University Human Ethics Committee (HEC 2020\/60).","order":2,"name":"Ethics","label":"Ethics approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":3,"name":"Ethics","label":"Consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}}]}}