{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T09:54:50Z","timestamp":1791280490448,"version":"4.1.0"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T00:00:00Z","timestamp":1791244800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T00:00:00Z","timestamp":1791244800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Phys Eng Sci Med"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    This study presents a novel optical dosimetry system designed to support three-dimensional characterisation of radiotherapy beams using a single-camera imaging geometry. The system combines a large-volume cylindrical plastic scintillator with a conical reflector, enabling scintillation light emitted during beam irradiation to be captured as both direct emission and secondary reflection arcs using a single camera. These reflected signals encode spatial information about the beam\u2019s position, size, and intensity, forming the basis for extracting clinically relevant parameters such as beam geometry and intensity from a single 2D image. Controlled experiments using a 6 MV photon beam investigated the system\u2019s response to changes in beam position, lateral width, and penumbra shape. Analysis of reflection arc geometry and intensity demonstrated strong linear correlations between beam position and arc radius over lateral and longitudinal shifts of up to 60\u00a0mm and 70\u00a0mm respectively, and a clear non-linear relationship between the average arc intensity and lateral beam field widths between 10 and 80\u00a0mm. Additionally, penumbra widths derived from reflection arc profiles were linearly proportional to those measured directly in the scintillator, with the arc penumbra approximately\n                    <jats:inline-formula>\n                      <jats:tex-math>$$\\:4.9\\:\\pm\\:\\:1.8$$<\/jats:tex-math>\n                    <\/jats:inline-formula>\n                    times wider than the underlying scintillator observed beam penumbra. This proof-of-concept study demonstrated that reflection arc geometry and intensity in a single 2D image provided sufficient information to infer spatial beam position, lateral field width, and penumbra characteristics for static irradiations. The simplicity, symmetry, and static design of the system support future development towards volumetric beam reconstruction and, through sequential image acquisition, potentially time-resolved treatment verification.\n                  <\/jats:p>","DOI":"10.1007\/s13246-026-01811-6","type":"journal-article","created":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T09:29:54Z","timestamp":1791278994000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A conical-reflector scintillation device for 3-dimensional measurement of radiotherapy beams: a feasibility study"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7693-9407","authenticated-orcid":false,"given":"Benjamin","family":"Broadhead","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7028-6452","authenticated-orcid":false,"given":"Scott","family":"Crowe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2136-6138","authenticated-orcid":false,"given":"Tanya","family":"Kairn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4817-4256","authenticated-orcid":false,"given":"Samuel","family":"Peet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9955-4609","authenticated-orcid":false,"given":"Andrew","family":"Fielding","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4008-1506","authenticated-orcid":false,"given":"Timothy","family":"Moroney","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5023-1558","authenticated-orcid":false,"given":"Prabhakar","family":"Ramachandran","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5254-0728","authenticated-orcid":false,"given":"Jamie","family":"Trapp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,10,6]]},"reference":[{"key":"1811_CR1","volume-title":"Clinical 3D dosimetry in modern radiation therapy","year":"2017","unstructured":"Mijnheer B (ed) (2017) Clinical 3D dosimetry in modern radiation therapy, 1st edn. CRC","edition":"1"},{"issue":"11","key":"1811_CR2","doi-asserted-by":"publisher","first-page":"5359","DOI":"10.1118\/1.3238104","volume":"36","author":"GA Ezzell","year":"2009","unstructured":"Ezzell GA, Burmeister JW, Dogan N, LoSasso TJ, Mechalakos JG, Mihailidis D, Molineu A, Palta JR, Ramsey CR, Salter BJ, Shi J, Xia P, Yue NJ, Xiao Y (2009) IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. Med Phys 36(11):5359\u20135373","journal-title":"Med Phys"},{"issue":"4","key":"1811_CR3","doi-asserted-by":"publisher","first-page":"e53","DOI":"10.1002\/mp.12810","volume":"45","author":"M Miften","year":"2018","unstructured":"Miften M, Olch A, Mihailidis D, Moran J, Pawlicki T, Molineu A, Li H, Wijesooriya K, Shi J, Xia P, Papanikolaou N, Low DA (2018) Tolerance limits and methodologies for IMRT measurement-based verification QA: recommendations of AAPM Task Group 218. Med Phys 45(4):e53\u2013e83","journal-title":"Med Phys"},{"issue":"5","key":"1811_CR4","doi-asserted-by":"publisher","first-page":"R1","DOI":"10.1088\/0031-9155\/55\/5\/R01","volume":"55","author":"C Baldock","year":"2010","unstructured":"Baldock C, De Deene Y, Doran S, Ibbott G, Jirasek A, Lepage M, McAuley KB, Oldham M, Schreiner LJ (2010) Polymer gel dosimetry. Phys Med Biol 55(5):R1\u2013R63","journal-title":"Phys Med Biol"},{"key":"1811_CR5","doi-asserted-by":"publisher","first-page":"107321","DOI":"10.1016\/j.radmeas.2024.107321","volume":"179","author":"Y De Deene","year":"2024","unstructured":"De Deene Y, Jirasek A (2024) Gel dosimetry: An overview of dosimetry systems and read out methods. Radiat Meas 179:107321","journal-title":"Radiat Meas"},{"key":"1811_CR6","first-page":"012014","volume":"164","author":"JV Trapp","year":"2009","unstructured":"Trapp JV, Kairn T, Crowe S, Fielding A (2009) Internal calibration of gel dosimeters: A feasibility study. J Phys: Conf Ser 164:012014","journal-title":"J Phys: Conf Ser"},{"issue":"3","key":"1811_CR7","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1007\/s13246-011-0081-5","volume":"34","author":"C Poole","year":"2011","unstructured":"Poole C, Trapp JV, Kenny J, Kairn T, Williams K, Taylor M, Franich R, Langton CM (2011) A hybrid radiation detector for simultaneous spatial and temporal dosimetry. Australas Phys Eng Sci Med 34(3):327\u2013332","journal-title":"Australas Phys Eng Sci Med"},{"key":"1811_CR8","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1016\/j.ijrobp.2009.07.1448","volume":"75","author":"B Zhao","year":"2009","unstructured":"Zhao B, Yang Y, Li T, Heron D, Huq M (2009) 3D Dose reconstruction using EPID images acquired during IMRT treatment. Int J Radiat Oncol Biol Phys 75:S633\u2013S634","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"1811_CR9","doi-asserted-by":"publisher","first-page":"e141","DOI":"10.1016\/j.ejmp.2014.10.065","volume":"30","author":"J Camilleri","year":"2014","unstructured":"Camilleri J, Mazurier J, Franck D, Gallocher O, Chevelle C, Latorzeff I, Jimenez G, Ducassou M, Marre D, Mathy N, Navarro P, Zarate D, Franceries X (2014) 2D\/3D EPID-based in-vivo dose reconstruction for dynamic IMRT treatments. Physica Med 30:e141\u2013e142","journal-title":"Physica Med"},{"key":"1811_CR10","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1016\/j.ejmp.2017.04.016","volume":"37","author":"I Olaciregui-Ruiz","year":"2017","unstructured":"Olaciregui-Ruiz I, Rozendaal R, van Oers RF, Mijnheer B, Mans A (2017) Virtual patient 3D dose reconstruction using in air EPID measurements and a back-projection algorithm for IMRT and VMAT treatments. Physica Med 37:49\u201357","journal-title":"Physica Med"},{"key":"1811_CR11","first-page":"012009","volume":"573","author":"D Low","year":"2015","unstructured":"Low D (2015) The importance of 3D dosimetry. J Phys: Conf Ser 573:012009","journal-title":"J Phys: Conf Ser"},{"key":"1811_CR12","volume-title":"Scintillation Dosimetry","year":"2016","unstructured":"Beddar S, Beaulieu L (eds) (2016) Scintillation dosimetry, 1st edn. CRC","edition":"1"},{"issue":"1","key":"1811_CR13","first-page":"296","volume":"41","author":"S Crowe","year":"2018","unstructured":"Crowe S, Sylvander S, Kairn T (2018) Art and science: fluorescence dosimetry using household materials. Australas Phys Eng Sci Med 41(1):296","journal-title":"Australas Phys Eng Sci Med"},{"issue":"13","key":"1811_CR14","doi-asserted-by":"publisher","first-page":"3063","DOI":"10.1088\/0031-9155\/50\/13\/007","volume":"50","author":"AS Kirov","year":"2005","unstructured":"Kirov AS, Piao JZ, Mathur NK, Miller TR, Devic S, Trichter S, Zaider M, Soares CG, LoSasso T (2005) The three-dimensional scintillation dosimetry method: Test for a 106Ru eye plaque applicator. Phys Med Biol 50(13):3063\u20133081","journal-title":"Phys Med Biol"},{"issue":"22","key":"1811_CR15","doi-asserted-by":"publisher","first-page":"5927","DOI":"10.1088\/0031-9155\/51\/22\/014","volume":"51","author":"Y Fukushima","year":"2006","unstructured":"Fukushima Y, Hamada M, Nishio T, Maruyama K (2006) Development of an easy-to-handle range measurement tool using a plastic scintillator for proton beam therapy. Phys Med Biol 51(22):5927\u20135936","journal-title":"Phys Med Biol"},{"issue":"5","key":"1811_CR16","doi-asserted-by":"publisher","first-page":"1736","DOI":"10.1118\/1.3117583","volume":"36","author":"S Beddar","year":"2009","unstructured":"Beddar S, Archambault L, Sahoo N, Poenisch F, Chen GT, Gillin MT, Mohan R (2009) Exploration of the potential of liquid scintillators for real-time 3D dosimetry of intensity modulated proton beams. Med Phys 36(5):1736\u20131743","journal-title":"Med Phys"},{"issue":"5","key":"1811_CR17","doi-asserted-by":"publisher","first-page":"1478","DOI":"10.1118\/1.3106390","volume":"36","author":"F P\u00f6nisch","year":"2009","unstructured":"P\u00f6nisch F, Archambault L, Briere TM, Sahoo N, Mohan R, Beddar S, Gillin MT (2009) Liquid scintillator for 2D dosimetry for high-energy photon beams. Med Phys 36(5):1478\u20131485","journal-title":"Med Phys"},{"issue":"3","key":"1811_CR18","doi-asserted-by":"publisher","first-page":"1239","DOI":"10.1118\/1.3681948","volume":"39","author":"L Archambault","year":"2012","unstructured":"Archambault L, Poenisch F, Sahoo N, Robertson D, Lee A, Gillin MT, Mohan R, Beddar S (2012) Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector system. Med Phys 39(3):1239\u20131246","journal-title":"Med Phys"},{"key":"1811_CR19","doi-asserted-by":"publisher","first-page":"4551","DOI":"10.1088\/1361-6560\/aa67cc","volume":"62","author":"K Yogo","year":"2017","unstructured":"Yogo K, Tatsuno Y, Tsuneda M, Aono Y, Mochizuki D, Fujisawa Y, Matsushita A, Ishigami M, Ishiyama H, Hayakawa K (2017) Practical use of a plastic scintillator for quality assurance of electron beam therapy. Phys Med Biol 62:4551\u20134570","journal-title":"Phys Med Biol"},{"issue":"1","key":"1811_CR20","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1007\/s13246-020-00946-4","volume":"44","author":"Y Ando","year":"2021","unstructured":"Ando Y, Miki K, Araki J, Tsuneda M, Kiriu H, Nishio T, Nagata Y (2021) Verification system for intensity-modulated radiation therapy with scintillator. Phys Eng Sci Med 44(1):9\u201321","journal-title":"Phys Eng Sci Med"},{"issue":"8","key":"1811_CR21","doi-asserted-by":"publisher","first-page":"082104","DOI":"10.1118\/1.4813898","volume":"40","author":"F Kroll","year":"2013","unstructured":"Kroll F, Pawelke J, Karsch L (2013) Preliminary investigations on the determination of three-dimensional dose distributions using scintillator blocks and optical tomography. Med Phys 40(8):082104","journal-title":"Med Phys"},{"issue":"8","key":"1811_CR22","first-page":"1","volume":"41","author":"M Goulet","year":"2014","unstructured":"Goulet M, Rilling M, Gingras L, Beddar S, Beaulieu L, Archambault L (2014) Novel, full 3D scintillation dosimetry using a static plenoptic camera. Med Phys 41(8):1\u201313","journal-title":"Med Phys"},{"key":"1811_CR23","doi-asserted-by":"publisher","first-page":"3636","DOI":"10.1002\/mp.14213","volume":"47","author":"M Rilling","year":"2020","unstructured":"Rilling M, Allain G, Thibault S, Archambault L (2020) Tomographic-based 3D scintillation dosimetry using a three-view plenoptic imaging system. Med Phys 47:3636\u20133646","journal-title":"Med Phys"},{"key":"1811_CR24","doi-asserted-by":"publisher","first-page":"907","DOI":"10.1088\/0031-9155\/26\/5\/010","volume":"26","author":"PC Shrimpton","year":"1981","unstructured":"Shrimpton PC (1981) Electron density values of various human tissues: in vitro Compton scatter measurements and calculated ranges. Phys Med Biol 26:907","journal-title":"Phys Med Biol"},{"issue":"3","key":"1811_CR25","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1016\/j.ejmp.2012.04.005","volume":"29","author":"G Li","year":"2013","unstructured":"Li G, Zhang Y, Jiang X, Bai S, Peng G, Wu K, Jiang Q (2013) Evaluation of the ArcCHECK QA system for IMRT and VMAT verification. Physica Med 29(3):295\u2013303","journal-title":"Physica Med"},{"issue":"3","key":"1811_CR26","doi-asserted-by":"publisher","first-page":"1501","DOI":"10.1118\/1.4942488","volume":"43","author":"SB Crowe","year":"2016","unstructured":"Crowe SB, Sutherland B, Wilks R, Seshadri V, Sylvander S, Trapp JV, Kairn T (2016) Relationships between gamma criteria and action levels: results of a multicenter audit of gamma agreement index results. Med Phys 43(3):1501\u20131506","journal-title":"Med Phys"}],"container-title":["Physical and Engineering Sciences in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-026-01811-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s13246-026-01811-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-026-01811-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T09:29:56Z","timestamp":1791278996000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s13246-026-01811-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,6]]},"references-count":26,"alternative-id":["1811"],"URL":"https:\/\/doi.org\/10.1007\/s13246-026-01811-6","relation":{},"ISSN":["2662-4729","2662-4737"],"issn-type":[{"value":"2662-4729","type":"print"},{"value":"2662-4737","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,6]]},"assertion":[{"value":"12 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 September 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 October 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors have no identified conflicts of interest.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors.","order":2,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}}]}}