{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T16:26:20Z","timestamp":1792081580026,"version":"4.4.0"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2022,4,12]],"date-time":"2022-04-12T00:00:00Z","timestamp":1649721600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0"},{"start":{"date-parts":[[2022,4,12]],"date-time":"2022-04-12T00:00:00Z","timestamp":1649721600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["81770955"],"award-info":[{"award-number":["81770955"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Joint Research Project of New Frontier Technology in Municipal Hospitals","award":["SHDC12018103"],"award-info":[{"award-number":["SHDC12018103"]}]},{"name":"Major clinical research project of Shanghai Shenkang Hospital Development Center","award":["SHDC2020CR1043B"],"award-info":[{"award-number":["SHDC2020CR1043B"]}]},{"name":"Project of Shanghai Xuhui District Science and Technology","award":["2020-015"],"award-info":[{"award-number":["2020-015"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ophthalmol Ther"],"published-print":{"date-parts":[[2022,6]]},"DOI":"10.1007\/s40123-022-00498-8","type":"journal-article","created":{"date-parts":[[2022,4,12]],"date-time":"2022-04-12T21:02:51Z","timestamp":1649797371000},"page":"1187-1198","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":29,"title":["Outcomes of the EVO ICL Using a Customized Non-horizontal or Horizontal Implanting Orientation Based on UBM Measurement: A Pilot Study"],"prefix":"10.1007","volume":"11","author":[{"given":"Ruoyan","family":"Wei","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mingrui","family":"Cheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lingling","family":"Niu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lin","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiumei","family":"Luo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Meiyan","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaodong","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoying","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3465-1579","authenticated-orcid":false,"given":"Xingtao","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peijun","family":"Yao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,4,12]]},"reference":[{"key":"498_CR1","doi-asserted-by":"publisher","first-page":"e943","DOI":"10.1111\/aos.14459","volume":"98","author":"R Wei","year":"2020","unstructured":"Wei R, Li M, Zhang H, et al. Comparison of objective and subjective visual quality early after implantable collamer lens V4c (ICL V4c) and small incision lenticule extraction (SMILE) for high myopia correction. Acta Ophthalmol. 2020;98:e943\u201350.","journal-title":"Acta Ophthalmol"},{"key":"498_CR2","doi-asserted-by":"publisher","first-page":"7","DOI":"10.3928\/1081597X-20201013-04","volume":"37","author":"S Brar","year":"2021","unstructured":"Brar S, Gautam M, Sute SS, Pereira S, Ganesh S. Visual and refractive outcomes with the eyecryl phakic toric IOL versus the visian toric implantable collamer lens: results of a 2-year prospective comparative study. J Refract Surg. 2021;37:7\u201315.","journal-title":"J Refract Surg"},{"key":"498_CR3","doi-asserted-by":"crossref","unstructured":"Garc\u00eca-Feijo\u00f3 J, Hern\u00e1ndez-Matamoros JL, Castillo-G\u00f3mez A, et al. Secondary glaucoma and severe endothelial damage after silicone phakic posterior chamber intraocular lens implantation. J Cataract Refract Surg. 2004;30:1786\u20139.","DOI":"10.1016\/j.jcrs.2004.02.046"},{"key":"498_CR4","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1186\/s12886-017-0663-4","volume":"17","author":"SW Nam","year":"2017","unstructured":"Nam SW, Lim DH, Hyun J, Chung E-S, Chung T-Y. Buffering zone of implantable collamer lens sizing in V4c. BMC Ophthalmol. 2017;17:260.","journal-title":"BMC Ophthalmol"},{"key":"498_CR5","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1016\/j.ophtha.2011.07.047","volume":"119","author":"D-H Lee","year":"2012","unstructured":"Lee D-H, Choi S-H, Chung E-S, Chung T-Y. Correlation between preoperative biometry and posterior chamber phakic visian implantable collamer lens vaulting. Ophthalmology. 2012;119:272\u20137.","journal-title":"Ophthalmology"},{"issue":"632\u20137","key":"498_CR6","first-page":"637.e1","volume":"153","author":"T Kojima","year":"2012","unstructured":"Kojima T, Yokoyama S, Ito M, et al. Optimization of an implantable collamer lens sizing method using high-frequency ultrasound biomicroscopy. Am J Ophthalmol. 2012;153(632\u20137):637.e1.","journal-title":"Am J Ophthalmol"},{"key":"498_CR7","doi-asserted-by":"publisher","first-page":"986","DOI":"10.1016\/j.jcrs.2011.12.027","volume":"38","author":"K Petermeier","year":"2012","unstructured":"Petermeier K, Suesskind D, Altpeter E, et al. Sulcus anatomy and diameter in pseudophakic eyes and correlation with biometric data: evaluation with a 50 MHz ultrasound biomicroscope. J Cataract Refract Surg. 2012;38:986\u201391.","journal-title":"J Cataract Refract Surg"},{"key":"498_CR8","doi-asserted-by":"publisher","first-page":"1686","DOI":"10.1016\/j.jcrs.2011.03.048","volume":"37","author":"J Biermann","year":"2011","unstructured":"Biermann J, Bredow L, Boehringer D, Reinhard T. Evaluation of ciliary sulcus diameter using ultrasound biomicroscopy in emmetropic eyes and myopic eyes. J Cataract Refract Surg. 2011;37:1686\u201393.","journal-title":"J Cataract Refract Surg"},{"key":"498_CR9","doi-asserted-by":"publisher","first-page":"1099","DOI":"10.1016\/j.jcrs.2019.02.020","volume":"45","author":"A Igarashi","year":"2019","unstructured":"Igarashi A, Shimizu K, Kato S, Kamiya K. Predictability of the vault after posterior chamber phakic intraocular lens implantation using anterior segment optical coherence tomography. J Cataract Refract Surg. 2019;45:1099\u2013104.","journal-title":"J Cataract Refract Surg"},{"key":"498_CR10","doi-asserted-by":"publisher","first-page":"742","DOI":"10.1097\/j.jcrs.0000000000000134","volume":"46","author":"T Nakamura","year":"2020","unstructured":"Nakamura T, Isogai N, Kojima T, Yoshida Y, Sugiyama Y. Optimization of implantable collamer lens sizing based on swept-source anterior segment optical coherence tomography. J Cataract Refract Surg. 2020;46:742\u20138.","journal-title":"J Cataract Refract Surg"},{"key":"498_CR11","doi-asserted-by":"publisher","first-page":"380","DOI":"10.3928\/1081597X-20200513-02","volume":"36","author":"Q Chen","year":"2020","unstructured":"Chen Q, Tan W, Lei X, et al. Clinical prediction of excessive vault after implantable collamer lens implantation using ciliary body morphology. J Refract Surg. 2020;36:380\u20137.","journal-title":"J Refract Surg"},{"key":"498_CR12","doi-asserted-by":"publisher","first-page":"2689","DOI":"10.1007\/s10792-017-0757-2","volume":"38","author":"F Matarazzo","year":"2018","unstructured":"Matarazzo F, Day AC, Fernandez-Vega Cueto L, Maurino V. Vertical implantable collamer lens (ICL) rotation for the management of high vault due to lens oversizing. Int Ophthalmol. 2018;38:2689\u201392.","journal-title":"Int Ophthalmol"},{"key":"498_CR13","doi-asserted-by":"publisher","first-page":"3070","DOI":"10.4103\/ijo.IJO_3030_20","volume":"68","author":"A Srirampur","year":"2020","unstructured":"Srirampur A, Mansoori T, Balijepalli P, Gadde AK. Management of anisocoria and high vault in an eye with implantable collamer lens. Indian J Ophthalmol. 2020;68:3070\u20132.","journal-title":"Indian J Ophthalmol"},{"key":"498_CR14","doi-asserted-by":"publisher","first-page":"728","DOI":"10.1097\/j.jcrs.0000000000000146","volume":"46","author":"AS Tranc\u00f3n","year":"2020","unstructured":"Tranc\u00f3n AS, Manito SC, Sierra OT, Baptista AM, Serra PM. Determining vault size in implantable collamer lenses: preoperative anatomy and lens parameters. J Cataract Refract Surg. 2020;46:728\u201336.","journal-title":"J Cataract Refract Surg"},{"key":"498_CR15","doi-asserted-by":"publisher","first-page":"519","DOI":"10.3928\/1081597X-20170602-02","volume":"33","author":"Qi Meng-ying","year":"2017","unstructured":"Meng-ying Qi, Qian C, Qing-yan Z. The effect of the crystalline lens on central vault after implantable collamer lens implantation. J Refract Surg. 2017;33:519\u201323.","journal-title":"J Refract Surg"},{"key":"498_CR16","doi-asserted-by":"publisher","first-page":"918","DOI":"10.1016\/S0886-3350(03)00065-8","volume":"29","author":"M Gonvers","year":"2003","unstructured":"Gonvers M, Bornet C, Othenin-Girard P. Implantable contact lens for moderate to high myopia: relationship of vaulting to cataract formation. J Cataract Refract Surg. 2003;29:918\u201324.","journal-title":"J Cataract Refract Surg"},{"key":"498_CR17","doi-asserted-by":"publisher","first-page":"1059","DOI":"10.2147\/OPTH.S111620","volume":"10","author":"M Packer","year":"2016","unstructured":"Packer M. Meta-analysis and review: effectiveness, safety, and central port design of the intraocular collamer lens. Clin Ophthalmol. 2016;10:1059\u201377.","journal-title":"Clin Ophthalmol"},{"key":"498_CR18","doi-asserted-by":"publisher","DOI":"10.1111\/aos.14584","author":"W Yang","year":"2020","unstructured":"Yang W, Zhao J, Zhao J, et al. Changes in anterior lens density after Implantable Collamer Lens V4c implantation: a 4-year prospective observational study. Acta Ophthalmol. 2020. https:\/\/doi.org\/10.1111\/aos.14584.","journal-title":"Acta Ophthalmol"},{"key":"498_CR19","doi-asserted-by":"publisher","first-page":"1807","DOI":"10.1007\/s00417-012-1957-0","volume":"250","author":"JF Alfonso","year":"2012","unstructured":"Alfonso JF, Fern\u00e1ndez-Vega L, Lisa C, Fernandes P, Gonz\u00e1lez-Meijome J, Mont\u00e9s-Mic\u00f3 R. Long-term evaluation of the central vault after phakic Collamer\u00ae lens (ICL) implantation using OCT. Graefes Arch Clin Exp Ophthalmol. 2012;250:1807\u201312.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"498_CR20","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1136\/bjophthalmol-2011-300148","volume":"96","author":"K Shimizu","year":"2012","unstructured":"Shimizu K, Kamiya K, Igarashi A, Shiratani T. Early clinical outcomes of implantation of posterior chamber phakic intraocular lens with a central hole (Hole ICL) for moderate to high myopia. Br J Ophthalmol. 2012;96:409\u201312.","journal-title":"Br J Ophthalmol"},{"key":"498_CR21","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1186\/s12886-018-0805-3","volume":"18","author":"H Miao","year":"2018","unstructured":"Miao H, Chen X, Tian M, Chen Y, Wang X, Zhou X. Refractive outcomes and optical quality after implantation of posterior chamber phakic implantable collamer lens with a central hole (ICL V4c). BMC Ophthalmol. 2018;18:141.","journal-title":"BMC Ophthalmol"}],"container-title":["Ophthalmology and Therapy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s40123-022-00498-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s40123-022-00498-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s40123-022-00498-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,5,17]],"date-time":"2022-05-17T17:55:52Z","timestamp":1652810152000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s40123-022-00498-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,12]]},"references-count":21,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022,6]]}},"alternative-id":["498"],"URL":"https:\/\/doi.org\/10.1007\/s40123-022-00498-8","relation":{},"ISSN":["2193-8245","2193-6528"],"issn-type":[{"value":"2193-8245","type":"print"},{"value":"2193-6528","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,4,12]]},"assertion":[{"value":"30 January 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 March 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 April 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}