{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,25]],"date-time":"2026-04-25T04:51:58Z","timestamp":1777092718061,"version":"3.51.4"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2022,6,25]],"date-time":"2022-06-25T00:00:00Z","timestamp":1656115200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0"},{"start":{"date-parts":[[2022,6,25]],"date-time":"2022-06-25T00:00:00Z","timestamp":1656115200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ophthalmol Ther"],"published-print":{"date-parts":[[2022,8]]},"DOI":"10.1007\/s40123-022-00538-3","type":"journal-article","created":{"date-parts":[[2022,6,25]],"date-time":"2022-06-25T05:07:54Z","timestamp":1656133674000},"page":"1601-1610","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Ultrasound Cyclo Plasty After Failed Glaucoma Surgery: Outcomes and Complications"],"prefix":"10.1007","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3504-2828","authenticated-orcid":false,"given":"Faisal A.","family":"Almobarak","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ahmed","family":"Alrubean","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Waleed K.","family":"Alsarhani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abdullah","family":"Aljenaidel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Essam","family":"Osman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,6,25]]},"reference":[{"key":"538_CR1","doi-asserted-by":"publisher","first-page":"2081","DOI":"10.1016\/j.ophtha.2014.05.013","volume":"121","author":"YC Tham","year":"2014","unstructured":"Tham YC, Li X, Wong TY, Quigley HA, Aung T, Cheng CY. Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis. Ophthalmology. 2014;121:2081\u201390.","journal-title":"Ophthalmology"},{"issue":"714\u201320","key":"538_CR2","first-page":"829","volume":"120","author":"MO Gordon","year":"2002","unstructured":"Gordon MO, Beiser JA, Brandt JD, et al. The Ocular Hypertension Treatment Study: baseline factors that predict the onset of primary open-angle glaucoma. Arch Ophthalmol. 2002;120(714\u201320):829\u201330.","journal-title":"Arch Ophthalmol"},{"key":"538_CR3","doi-asserted-by":"publisher","first-page":"7136275","DOI":"10.1155\/2017\/7136275","volume":"2017","author":"R Mastropasqua","year":"2017","unstructured":"Mastropasqua R, Fasanella V, Mastropasqua A, Ciancaglini M, Agnifili L. High-intensity focused ultrasound circular cyclocoagulation in glaucoma: a step forward for cyclodestruction? J Ophthalmol. 2017;2017:7136275.","journal-title":"J Ophthalmol"},{"issue":"685\u2013695","key":"538_CR4","volume":"148","author":"SK Law","year":"2009","unstructured":"Law SK, Shih K, Tran DH, Coleman AL, Caprioli J. Long-term outcomes of repeat vs initial trabeculectomy in open-angle glaucoma. Am J Ophthalmol. 2009;148(685\u2013695): e1.","journal-title":"Am J Ophthalmol"},{"key":"538_CR5","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1007\/s00417-016-3563-z","volume":"255","author":"G Giannaccare","year":"2017","unstructured":"Giannaccare G, Vagge A, Gizzi C, et al. High-intensity focused ultrasound treatment in patients with refractory glaucoma. Graefes Arch Clin Exp Ophthalmol. 2017;255:599\u2013605.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"538_CR6","doi-asserted-by":"publisher","first-page":"8747","DOI":"10.1167\/iovs.11-8137","volume":"52","author":"F Aptel","year":"2011","unstructured":"Aptel F, Charrel T, Lafon C, et al. Miniaturized high-intensity focused ultrasound device in patients with glaucoma: a clinical pilot study. Invest Ophthalmol Vis Sci. 2011;52:8747\u201353.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"538_CR7","doi-asserted-by":"publisher","first-page":"483","DOI":"10.5301\/ejo.5000620","volume":"25","author":"S Melamed","year":"2015","unstructured":"Melamed S, Goldenfeld M, Cotlear D, Skaat A, Moroz I. High-intensity focused ultrasound treatment in refractory glaucoma patients: results at 1 year of prospective clinical study. Eur J Ophthalmol. 2015;25:483\u20139.","journal-title":"Eur J Ophthalmol"},{"key":"538_CR8","doi-asserted-by":"publisher","first-page":"1089","DOI":"10.1167\/iovs.14-14973","volume":"56","author":"P Denis","year":"2015","unstructured":"Denis P, Aptel F, Rouland JF, et al. Cyclocoagulation of the ciliary bodies by high-intensity focused ultrasound: a 12-month multicenter study. Invest Ophthalmol Vis Sci. 2015;56:1089\u201396.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"538_CR9","doi-asserted-by":"publisher","first-page":"2429","DOI":"10.1007\/s00417-017-3817-4","volume":"255","author":"A De Gregorio","year":"2017","unstructured":"De Gregorio A, Pedrotti E, Stevan G, Montali M, Morselli S. Safety and efficacy of multiple cyclocoagulation of ciliary bodies by high-intensity focused ultrasound in patients with glaucoma. Graefes Arch Clin Exp Ophthalmol. 2017;255:2429\u201335.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"538_CR10","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1016\/j.ajo.2005.03.057","volume":"140","author":"DA Jabs","year":"2005","unstructured":"Jabs DA, Nussenblatt RB, Rosenbaum JT, Standardization of Uveitis Nomenclature Working G. Standardization of uveitis nomenclature for reporting clinical data. Results of the First International Workshop. Am J Ophthalmol. 2005;140:509\u201316.","journal-title":"Am J Ophthalmol"},{"issue":"160\u20138","key":"538_CR11","first-page":"e1","volume":"159","author":"KE Kim","year":"2015","unstructured":"Kim KE, Jeoung JW, Kim DM, Ahn SJ, Park KH, Kim SH. Long-term follow-up in preperimetric open-angle glaucoma: progression rates and associated factors. Am J Ophthalmol. 2015;159(160\u20138):e1-2.","journal-title":"Am J Ophthalmol"},{"key":"538_CR12","doi-asserted-by":"publisher","first-page":"1965","DOI":"10.1016\/j.ophtha.2007.03.016","volume":"114","author":"MC Leske","year":"2007","unstructured":"Leske MC, Heijl A, Hyman L, et al. Predictors of long-term progression in the early manifest glaucoma trial. Ophthalmology. 2007;114:1965\u201372.","journal-title":"Ophthalmology"},{"key":"538_CR13","doi-asserted-by":"publisher","first-page":"5092","DOI":"10.1167\/iovs.09-5135","volume":"51","author":"F Aptel","year":"2010","unstructured":"Aptel F, Charrel T, Palazzi X, Chapelon JY, Denis P, Lafon C. Histologic effects of a new device for high-intensity focused ultrasound cyclocoagulation. Invest Ophthalmol Vis Sci. 2010;51:5092\u20138.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"538_CR14","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1097\/IJG.0000000000001400","volume":"29","author":"F Aptel","year":"2020","unstructured":"Aptel F, Tadjine M, Rouland JF. Efficacy and safety of repeated ultrasound cycloplasty procedures in patients with early or delayed failure after a first procedure. J Glaucoma. 2020;29:24\u201330.","journal-title":"J Glaucoma"},{"key":"538_CR15","doi-asserted-by":"publisher","first-page":"1668","DOI":"10.1136\/bjophthalmol-2015-308069","volume":"100","author":"R Mastropasqua","year":"2016","unstructured":"Mastropasqua R, Agnifili L, Fasanella V, et al. Uveo-scleral outflow pathways after ultrasonic cyclocoagulation in refractory glaucoma: an anterior segment optical coherence tomography and in vivo confocal study. Br J Ophthalmol. 2016;100:1668\u201375.","journal-title":"Br J Ophthalmol"},{"key":"538_CR16","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1177\/1120672119874594","volume":"31","author":"J Hugo","year":"2021","unstructured":"Hugo J, Matonti F, Beylerian M, Zanin E, Aptel F, Denis D. Safety and efficacy of high-intensity focused ultrasound in severe or refractory glaucoma. Eur J Ophthalmol. 2021;31:130\u20137.","journal-title":"Eur J Ophthalmol"}],"container-title":["Ophthalmology and Therapy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s40123-022-00538-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s40123-022-00538-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s40123-022-00538-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,4]],"date-time":"2022-07-04T16:06:22Z","timestamp":1656950782000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s40123-022-00538-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,25]]},"references-count":16,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022,8]]}},"alternative-id":["538"],"URL":"https:\/\/doi.org\/10.1007\/s40123-022-00538-3","relation":{},"ISSN":["2193-8245","2193-6528"],"issn-type":[{"value":"2193-8245","type":"print"},{"value":"2193-6528","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,25]]},"assertion":[{"value":"25 April 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 June 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 June 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}