{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T23:52:06Z","timestamp":1788565926927,"version":"build-2803163510"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2024,4,25]],"date-time":"2024-04-25T00:00:00Z","timestamp":1714003200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0"},{"start":{"date-parts":[[2024,4,25]],"date-time":"2024-04-25T00:00:00Z","timestamp":1714003200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ophthalmol Ther"],"published-print":{"date-parts":[[2024,6]]},"DOI":"10.1007\/s40123-024-00946-7","type":"journal-article","created":{"date-parts":[[2024,4,24]],"date-time":"2024-04-24T23:37:06Z","timestamp":1714001826000},"page":"1703-1722","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Predictability of Existing IOL Formulas After Cataract Surgery in Patients with a Previous History of Radial Keratotomy: A Retrospective Cohort Study and Literature Review"],"prefix":"10.1007","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1024-6250","authenticated-orcid":false,"given":"Majid","family":"Moshirfar","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ronald A.","family":"Sperry","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amal W.","family":"Altaf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Isabella M.","family":"Stoakes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Phillip C.","family":"Hoopes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,4,25]]},"reference":[{"issue":"Pt 1","key":"946_CR1","first-page":"28","volume":"104","author":"GO Waring III","year":"1985","unstructured":"Waring III GO. Evolution of radial keratotomy for myopia. Trans Ophthalmol Soc U K. 1985;104(Pt 1):28\u201342.","journal-title":"Trans Ophthalmol Soc U K"},{"issue":"7","key":"946_CR2","doi-asserted-by":"publisher","first-page":"1103","DOI":"10.1016\/S0161-6420(13)31536-X","volume":"100","author":"American Academy of Ophthalmology","year":"1993","unstructured":"American Academy of Ophthalmology. Radial keratotomy for myopia. Ophthalmology. 1993;100(7):1103\u201315.","journal-title":"Ophthalmology"},{"issue":"1","key":"946_CR3","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1097\/00004397-199703710-00010","volume":"37","author":"V Filatov","year":"1997","unstructured":"Filatov V, Vidaurri-Leal JS, Talamo JH. Selected complications of radial keratotomy, photorefractive keratectomy, and laser in situ keratomileusis. Int Ophthalmol Clin. 1997;37(1):123\u201348. https:\/\/doi.org\/10.1097\/00004397-199703710-00010.","journal-title":"Int Ophthalmol Clin"},{"issue":"4","key":"946_CR4","doi-asserted-by":"publisher","first-page":"275","DOI":"10.3928\/1081597x-20120221-03","volume":"28","author":"M Camellin","year":"2012","unstructured":"Camellin M, Savini G, Hoffer KJ, Carbonelli M, Barboni P. Scheimpflug camera measurement of anterior and posterior corneal curvature in eyes with previous radial keratotomy. J Refract Surg. 2012;28(4):275\u20139. https:\/\/doi.org\/10.3928\/1081597x-20120221-03.","journal-title":"J Refract Surg"},{"issue":"1","key":"946_CR5","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/s0886-3350(02)01693-0)","volume":"29","author":"L Chen","year":"2003","unstructured":"Chen L, Mannis MJ, Salz JJ, Garcia-Ferrer FJ, Ge J. Analysis of intraocular lens power calculation in post-radial keratotomy eyes. J Cataract Refract Surg. 2003;29(1):65\u201370. https:\/\/doi.org\/10.1016\/s0886-3350(02)01693-0).","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"946_CR6","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1016\/j.jcrs.2012.09.019","volume":"39","author":"R Potvin","year":"2013","unstructured":"Potvin R, Hill W. New algorithm for post-radial keratotomy intraocular lens power calculations based on rotating Scheimpflug camera data. J Cataract Refract Surg. 2013;39(3):358\u201365. https:\/\/doi.org\/10.1016\/j.jcrs.2012.09.019.","journal-title":"J Cataract Refract Surg"},{"key":"946_CR7","doi-asserted-by":"crossref","unstructured":"Demill DL, Hsu M, Moshirfar M. Evaluation of the American Society of Cataract and Refractive Surgery intraocular lens calculator for eyes with prior radial keratotomy. 2011;5: 1243\u20137.","DOI":"10.2147\/OPTH.S24514"},{"key":"946_CR8","doi-asserted-by":"publisher","unstructured":"Li M, Wang J, Zhang J, et al. Comparison of the accuracy of three intraocular lens power calculation formulas in cataract patients with prior radial keratotomy. Eur J Med Res. 2023;28(1):20. https:\/\/doi.org\/10.1186\/s40001-023-00998-8.","DOI":"10.1186\/s40001-023-00998-8"},{"issue":"12","key":"946_CR9","doi-asserted-by":"publisher","first-page":"832","DOI":"10.3928\/1081597X-20200930-02","volume":"36","author":"R Leite de Pinho Tavares","year":"2020","unstructured":"Tavares R, Ferreira G, Ghanem V,\u00a0et al. IOL power calculation after radial keratotomy using the Haigis and Barrett True-K formulas. J Refract Surg. 2020;36(12):832\u20137.","journal-title":"J Refract Surg"},{"key":"946_CR10","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.ajo.2021.05.004","volume":"232","author":"G Debellemani\u00e8re","year":"2021","unstructured":"Debellemani\u00e8re G, Dubois M, Gauvin M, et al. The PEARL-DGS formula: the development of an open-source machine learning-based thick IOL calculation formula. Am J Ophthalmol. 2021;232:58\u201369. https:\/\/doi.org\/10.1016\/j.ajo.2021.05.004.","journal-title":"Am J Ophthalmol"},{"key":"946_CR11","doi-asserted-by":"crossref","unstructured":"Moshirfar M, Sulit C, Brown A. Comparing the accuracy of the Kane, Barrett Universal II, Hill-Radial Basis Function, Emmetropia Verifying Optical, and Ladas Super Formula intraocular lens power calculation formulas. Clin Ophthalmol. 2023;17:2643-52.","DOI":"10.2147\/OPTH.S417865"},{"issue":"8","key":"946_CR12","doi-asserted-by":"publisher","first-page":"999","DOI":"10.1016\/j.jcrs.2017.08.003","volume":"43","author":"L Wang","year":"2017","unstructured":"Wang L, Koch DD, Hill W, Abulafia A. Pursuing perfection in intraocular lens calculations: III. Criteria for analyzing outcomes. J Cataract Refract Surg. 2017;43(8):999\u20131002. https:\/\/doi.org\/10.1016\/j.jcrs.2017.08.003.","journal-title":"J Cataract Refract Surg"},{"issue":"9","key":"946_CR13","doi-asserted-by":"publisher","first-page":"1240","DOI":"10.1097\/j.jcrs.0000000000000238","volume":"46","author":"C Lwowski","year":"2020","unstructured":"Lwowski C, Pawlowicz K, Hinzelmann L, Adas M, Kohnen T. Prediction accuracy of IOL calculation formulas using the ASCRS online calculator for a diffractive extended depth-of-focus IOL after myopic laser in situ keratomileusis. J Cataract Refract Surg. 2020;46(9):1240\u20136. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000238.","journal-title":"J Cataract Refract Surg"},{"key":"946_CR14","volume-title":"Origin of the ASCRS online post-refractive IOL power calculator","author":"D Koch","year":"2009","unstructured":"Koch D. Origin of the ASCRS online post-refractive IOL power calculator. American Academy of Ophthalmology. 2009. https:\/\/www.aao.org\/education\/editors-choice\/origin-of-ascrs-online-postrefractive-iol-power-ca. Accessed 08 Dec 2023"},{"key":"946_CR15","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1016\/j.jcrs.2015.11.039","volume":"42","author":"A Abulafia","year":"2016","unstructured":"Abulafia A, Hill WE, Koch DD, Wang L, Barrett GD. Accuracy of the Barrett True-K formula for intraocular lens power prediction after laser in situ keratomileusis or photorefractive keratectomy for myopia. J Cataract Refract Surg. 2016;42:363\u20139.","journal-title":"J Cataract Refract Surg"},{"key":"946_CR16","unstructured":"\u201cModified Double-K Holladay 1 Formula.\u201d https:\/\/iolcalc.ascrs.org\/wbfrmCalculator3.aspx. Accessed 20 July 2023."},{"key":"946_CR17","first-page":"34","volume":"111","author":"D Huang","year":"2013","unstructured":"Huang D, Tang M, Wang L, et al. Optical coherence tomography-based corneal power measurement and intraocular lens power calculation following laser vision correction (an American Ophthalmological Society thesis). Trans Am Ophthalmol Soc. 2013;111:34\u201345.","journal-title":"Trans Am Ophthalmol Soc"},{"issue":"6","key":"946_CR18","doi-asserted-by":"publisher","first-page":"430","DOI":"10.3928\/1081597X-20090710-02","volume":"26","author":"M Tang","year":"2010","unstructured":"Tang M, Li Y, Huang D. An intraocular lens power calculation formula based on optical coherence tomography: a pilot study. J Refract Surg. 2010;26(6):430\u20137.","journal-title":"J Refract Surg"},{"key":"946_CR19","unstructured":"Bhattacharya Subhabrata. Guide to Pentacam Holladay Ekr report. www.quickguide.org\/post\/holladay-ekr-report#:~:text=The%20EKR%2065%20takes%20into,Q%2C%20Holladay%20I%2C%20etc. Accessed 21 Jan 2023."},{"key":"946_CR20","unstructured":"East Valley Ophthalmology. \u201cHaigis Formula.\u201d https:\/\/doctor-hill.com\/iol-power-calculations\/formulas\/haigis-formula\/. Accessed 21 July 2023."},{"key":"946_CR21","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1097\/j.jcrs.0000000000000205","volume":"46","author":"G Savini","year":"2020","unstructured":"Savini G, Hoffer KJ, Balducci N, Barboni P, Schiano-Lomoriello D. Comparison of formula accuracy for intraocular lens power calculation based on measurements by a swept-source optical coherence tomography optical biometer. J Cataract Refract Surg. 2020;46:27\u201333.","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"946_CR22","doi-asserted-by":"publisher","first-page":"187","DOI":"10.3928\/1081-597X-20060201-18","volume":"22","author":"M Camellin","year":"2006","unstructured":"Camellin M, Calossi A. A new formula for intraocular lens power calculation after refractive corneal surgery. J Refract Surg. 2006;22(2):187\u201399. https:\/\/doi.org\/10.3928\/1081-597X-20060201-18.","journal-title":"J Refract Surg"},{"issue":"9","key":"946_CR23","doi-asserted-by":"publisher","first-page":"1236","DOI":"10.1097\/j.jcrs.0000000000000235","volume":"46","author":"JX Kane","year":"2020","unstructured":"Kane JX, Melles RB. Intraocular lens formula comparison in axial hyperopia with a high-power intraocular lens of 30 or more diopters. J Cataract Refract Surg. 2020;46(9):1236\u20139. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000235.","journal-title":"J Cataract Refract Surg"},{"key":"946_CR24","unstructured":"Johnson & Johnson Vision. TECNIS\u00ae Monofocal 1-Piece IOL. www.jnjvisionpro.com\/products\/TECNIS-1-piece-iol. Accessed 24 Apr 2023."},{"key":"946_CR25","unstructured":"Bausch + Lomb. Iol Envista\u00ae. www.bauschsurgical.com\/cataract\/envista-and-envista-toric\/#Technical-Data. Accessed 20 July 2023."},{"key":"946_CR26","unstructured":"IOLS Directory. ACRYSOF IQ SN60WF\/ULTRASERT AUC0T0. https:\/\/iols.eu\/product\/lenses\/acrysof-iq-sn60wf-ultrasert-auc0t0\/. Accessed 6 Feb 2019."},{"issue":"4","key":"946_CR27","doi-asserted-by":"publisher","first-page":"356","DOI":"10.1016\/S0039-6257(98)00052-6","volume":"43","author":"DC Brick","year":"1999","unstructured":"Brick DC. Risk management lessons from a review of 168 cataract surgery claims*. Surv Ophthalmol. 1999;43(4):356\u201360.","journal-title":"Surv Ophthalmol"},{"issue":"9","key":"946_CR28","doi-asserted-by":"publisher","first-page":"OCT162","DOI":"10.1167\/iovs.15-18948","volume":"57","author":"JX Ma","year":"2016","unstructured":"Ma JX, Tang M, Wang L, Weikert MP, Huang D, Koch DD. Comparison of newer IOL power calculation methods for eyes with previous radial keratotomy. Invest Ophthalmol Vis Sci. 2016;57(9):OCT162\u20138. https:\/\/doi.org\/10.1167\/iovs.15-18948.","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"1","key":"946_CR29","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1016\/j.ophtha.2019.08.019","volume":"127","author":"AMJ Turnbull","year":"2020","unstructured":"Turnbull AMJ, Crawford GJ, Barrett GD. Methods for intraocular lens power calculation in cataract surgery after radial keratotomy. Ophthalmology. 2020;127(1):45\u201351. https:\/\/doi.org\/10.1016\/j.ophtha.2019.08.019.","journal-title":"Ophthalmology"},{"key":"946_CR30","doi-asserted-by":"publisher","unstructured":"Armstrong RA. When to use the Bonferroni correction-Wiley Online Library. https:\/\/doi.org\/10.1111\/opo.12131. Accessed 20 July 2023.","DOI":"10.1111\/opo.12131"},{"key":"946_CR31","unstructured":"Universit\u00e4t D\u00fcsseldorf. G*Power. Retrieved from the www.psychologie.hhu.de website: https:\/\/www.psychologie.hhu.de\/arbeitsgruppen\/allgemeine-psychologie-und-arbeitspsychologie\/gpower. Accessed 19 Jul 2023"},{"issue":"10","key":"946_CR32","doi-asserted-by":"publisher","first-page":"680","DOI":"10.3928\/1081597X-20210712-03","volume":"37","author":"Y Chen","year":"2021","unstructured":"Chen Y, Wei L, He W, Lu Y, Zhu X. Comparison of Kane, Hill-RBF 20, Barrett Universal II, and emmetropia verifying optical formulas in eyes with extreme myopia. J Refract Surg. 2021;37(10):680\u20135. https:\/\/doi.org\/10.3928\/1081597X-20210712-03.","journal-title":"J Refract Surg"},{"key":"946_CR33","doi-asserted-by":"publisher","unstructured":"Ferrara S, Crincoli E, Savastano A, et al. Refractive outcomes with new generation formulas for iol power calculation in radial keratotomy patients. Cornea. 2024;43(2):178-83. https:\/\/doi.org\/10.1097\/ICO.0000000000003301.","DOI":"10.1097\/ICO.0000000000003301"},{"key":"946_CR34","doi-asserted-by":"crossref","unstructured":"Mena-Linares E, Ponce-Mart\u00ednez J, Messina-Baas O, et al. Refractive error with the Barrett True-K No History versus Panacea formula in cataract operated patients with a history of radial keratotomy. Rev M\u00e9d Hosp Gen M\u00e9x. 2021. www.hospitalgeneral.mx\/frame_esp.php?id=110.","DOI":"10.24875\/HGMX.21000014"},{"issue":"5","key":"946_CR35","doi-asserted-by":"publisher","first-page":"897","DOI":"10.1016\/j.ophtha.2014.12.002","volume":"122","author":"HS Geggel","year":"2015","unstructured":"Geggel HS. Intraocular lens power selection after radial keratotomy: topography, manual, and IOLMaster keratometry results using Haigis formulas. Ophthalmology. 2015;122(5):897\u2013902. https:\/\/pubmed.ncbi.nlm.nih.gov\/25601534\/","journal-title":"Ophthalmology"},{"issue":"11","key":"946_CR36","doi-asserted-by":"publisher","first-page":"2366","DOI":"10.1016\/j.jcrs.2015.04.032","volume":"41","author":"C Suto","year":"2015","unstructured":"Suto C, et al. Comparison of 2 optical biometers and evaluation of the Camellin-Calossi intraocular lens formula for normal cataractous eyes. J Cataract Refract Surg. 2015;41(11):2366\u201372. https:\/\/doi.org\/10.1016\/j.jcrs.2015.04.032.","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"946_CR37","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1007\/s10384-016-0452-2","volume":"60","author":"Y Yaguchi","year":"2016","unstructured":"Yaguchi Y, et al. Comparison of the accuracy of intraocular lens power calculations for cataract surgery in eyes after phototherapeutic keratectomy. Jpn J Ophthalmol. 2016;60(5):365\u201372. https:\/\/doi.org\/10.1007\/s10384-016-0452-2.","journal-title":"Jpn J Ophthalmol"},{"key":"946_CR38","doi-asserted-by":"publisher","first-page":"2589","DOI":"10.2147\/OPTH.S417336","volume":"17","author":"HA Helaly","year":"2023","unstructured":"Helaly HA, Elhady AM, Elnaggar OR. Accuracy of traditional and modern formulas for intraocular lens power calculation after radial keratotomy using standard keratometry. Clin Ophthalmol. 2023;17:2589\u201397. https:\/\/doi.org\/10.2147\/OPTH.S417336.","journal-title":"Clin Ophthalmol"}],"container-title":["Ophthalmology and Therapy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s40123-024-00946-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s40123-024-00946-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s40123-024-00946-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,21]],"date-time":"2024-05-21T08:32:25Z","timestamp":1716280345000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s40123-024-00946-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,25]]},"references-count":38,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2024,6]]}},"alternative-id":["946"],"URL":"https:\/\/doi.org\/10.1007\/s40123-024-00946-7","relation":{},"ISSN":["2193-8245","2193-6528"],"issn-type":[{"value":"2193-8245","type":"print"},{"value":"2193-6528","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,25]]},"assertion":[{"value":"19 February 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 March 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 April 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Majid Moshirfar is an Editorial Board member of<i> Ophthalmology and Therapy<\/i>. Majid Moshirfar was not involved in the selection of peer reviewers for the manuscript nor any of the subsequent editorial decisions. Ronald A Sperry, Amal W Altaf, Isabella M Stoakes, and Phillip C Hoopes have nothing to disclose.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of Interest"}},{"value":"This study was approved by The Biomedical Research Alliance of New York (BRANY) Institutional Review Board (#A20-12-547-823) and adhered to the tenets of the Declaration of Helsinki; it was also approved by the Hoopes Vision Ethics Committee.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical Approval"}}]}}