{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T07:42:19Z","timestamp":1767858139661,"version":"3.49.0"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2024,10,9]],"date-time":"2024-10-09T00:00:00Z","timestamp":1728432000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0"},{"start":{"date-parts":[[2024,10,9]],"date-time":"2024-10-09T00:00:00Z","timestamp":1728432000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"funder":[{"DOI":"10.13039\/501100002806","name":"Carl Zeiss Meditec AG","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100002806","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ophthalmol Ther"],"published-print":{"date-parts":[[2024,12]]},"DOI":"10.1007\/s40123-024-01046-2","type":"journal-article","created":{"date-parts":[[2024,10,9]],"date-time":"2024-10-09T18:01:56Z","timestamp":1728496916000},"page":"3059-3077","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Geometry of Modern Presbyopia-Correcting Intraocular Lenses and Changes in Haptic\u2013Capsular Bag Behavior According to Compression and Different Well Diameters: A Bench Study Using Computed Tomography"],"prefix":"10.1007","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6341-9069","authenticated-orcid":false,"given":"Andreas F.","family":"Borkenstein","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eva-Maria","family":"Borkenstein","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,10,9]]},"reference":[{"key":"1046_CR1","doi-asserted-by":"publisher","first-page":"3439","DOI":"10.2147\/OPTH.S269597","volume":"14","author":"J Berdahl","year":"2020","unstructured":"Berdahl J, Bala C, Dhariwal M, Lemp-Hull J, Thakker D, Jawla S. Patient and economic burden of presbyopia: a systematic literature review. Clin Ophthalmol. 2020;14:3439\u201350.","journal-title":"Clin Ophthalmol"},{"key":"1046_CR2","unstructured":"PC-IOL demand rises modestly, soars in a few countries | OBN. 2022. https:\/\/ophthalmologybreakingnews.com\/market-scope--global-pc-iol-demand-rises-modestly-soars-in-a-few-countries. Accessed 2023 Dec 18."},{"key":"1046_CR3","unstructured":"Behndig A, Dickman M, Lundstr\u00f6m M, et al. ESCRS EUREQUO annual report 2022: annual report 2022 based on data from the European registry of quality outcomes for cataract and refractive surgery. https:\/\/www.escrs.org\/media\/vospk2gx\/eurequo-annual-report-2022-2023_final.pdf."},{"issue":"2","key":"1046_CR4","doi-asserted-by":"publisher","first-page":"e130","DOI":"10.1016\/S2214-109X(20)30425-3","volume":"9","author":"R Bourne","year":"2021","unstructured":"Bourne R, Steinmetz JD, Flaxman S, et al. Trends in prevalence of blindness and distance and near vision impairment over 30\u00a0years: an analysis for the Global Burden of Disease Study. Lancet Glob Health. 2021;9(2):e130\u201343.","journal-title":"Lancet Glob Health"},{"key":"1046_CR5","doi-asserted-by":"publisher","first-page":"2167","DOI":"10.2147\/OPTH.S259011","volume":"15","author":"JA Katz","year":"2021","unstructured":"Katz JA, Karpecki PM, Dorca A, Chiva-Razavi S, Floyd H, Barnes E, et al. Presbyopia\u2014a review of current treatment options and emerging therapies. Clin Ophthalmol. 2021;15:2167\u201378.","journal-title":"Clin Ophthalmol"},{"key":"1046_CR6","unstructured":"Market Scope. 2022 IOL Market Report Brochure: 2022 IOL market report [global anlysis for 2021 to 2027] 2022; 2022. https:\/\/www.market-scope.com\/files\/products\/brochures\/313\/2022%20IOL%20Report%20Brochure.pdf."},{"issue":"12","key":"1046_CR7","doi-asserted-by":"publisher","first-page":"3639","DOI":"10.12998\/wjcc.v10.i12.3639","volume":"10","author":"X-Y Chen","year":"2022","unstructured":"Chen X-Y, Wang Y-C, Zhao T-Y, Wang Z-Z, Wang W. Tilt and decentration with various intraocular lenses: a narrative review. World J Clin Cases. 2022;10(12):3639\u201346.","journal-title":"World J Clin Cases"},{"key":"1046_CR8","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1016\/j.ajo.2023.01.024","volume":"251","author":"M Karam","year":"2023","unstructured":"Karam M, Alkhowaiter N, Alkhabbaz A, et al. Extended depth of focus versus trifocal for intraocular lens implantation: an updated systematic review and meta-analysis. Am J Ophthalmol. 2023;251:52\u201370.","journal-title":"Am J Ophthalmol"},{"key":"1046_CR9","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001371","author":"A Renschler","year":"2023","unstructured":"Renschler A, Kelkar N, Eid K, et al. Complications of foldable intraocular lenses requiring explantation or secondary intervention\u20142022 survey with update of long-term trends. J Cataract Refract Surg. 2023. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001371.","journal-title":"J Cataract Refract Surg"},{"issue":"12","key":"1046_CR10","first-page":"CD003169","volume":"12","author":"SR de Silva","year":"2016","unstructured":"de Silva SR, Evans JR, Kirthi V, Ziaei M, Leyland M. Multifocal versus monofocal intraocular lenses after cataract extraction. Cochrane Database Syst Rev. 2016;12(12):CD003169.","journal-title":"Cochrane Database Syst Rev"},{"issue":"2","key":"1046_CR11","doi-asserted-by":"publisher","first-page":"711","DOI":"10.1007\/s40123-022-00469-z","volume":"11","author":"AF Borkenstein","year":"2022","unstructured":"Borkenstein AF, Borkenstein E-M. Geometry of acrylic, hydrophobic IOLs and changes in haptic-capsular bag relationship according to compression and different well diameters: a bench study using computed tomography. Ophthalmol Ther. 2022;11(2):711\u201327.","journal-title":"Ophthalmol Ther"},{"issue":"4","key":"1046_CR12","doi-asserted-by":"publisher","first-page":"1127","DOI":"10.1007\/s10439-019-02432-9","volume":"48","author":"I Cabeza-Gil","year":"2020","unstructured":"Cabeza-Gil I, Ariza-Gracia M\u00c1, Rem\u00f3n L, Calvo B. Systematic study on the biomechanical stability of C-loop intraocular lenses: approach to an optimal design of the haptics. Ann Biomed Eng. 2020;48(4):1127\u201336.","journal-title":"Ann Biomed Eng"},{"issue":"4","key":"1046_CR13","doi-asserted-by":"publisher","first-page":"501","DOI":"10.1016\/j.jcrs.2018.10.043","volume":"45","author":"S Lane","year":"2019","unstructured":"Lane S, Collins S, Das KK, et al. Evaluation of intraocular lens mechanical stability. J Cataract Refract Surg. 2019;45(4):501\u20136.","journal-title":"J Cataract Refract Surg"},{"issue":"20","key":"1046_CR14","doi-asserted-by":"publisher","first-page":"4593","DOI":"10.3390\/ma13204593","volume":"13","author":"M Mochiji","year":"2020","unstructured":"Mochiji M, Kaidzu S, Ishiba Y, Matsuda Y, Tanito M. Measurement of force required for anterior displacement of intraocular lenses and its defining parameters. Materials. 2020;13(20):4593.","journal-title":"Materials"},{"issue":"3","key":"1046_CR15","first-page":"1","volume":"23","author":"L Rem\u00f3n","year":"2018","unstructured":"Rem\u00f3n L, Siedlecki D, Cabeza-Gil I, Calvo B. Influence of material and haptic design on the mechanical stability of intraocular lenses by means of finite-element modeling. J Biomed Opt. 2018;23(3):1\u201310.","journal-title":"J Biomed Opt"},{"issue":"11","key":"1046_CR16","doi-asserted-by":"publisher","first-page":"e74","DOI":"10.1016\/j.ophtha.2020.06.055","volume":"128","author":"L Werner","year":"2021","unstructured":"Werner L. Intraocular lenses: overview of designs, materials, and pathophysiologic features. Ophthalmology. 2021;128(11):e74\u201393.","journal-title":"Ophthalmology"},{"issue":"6 Suppl","key":"1046_CR17","doi-asserted-by":"publisher","first-page":"S3","DOI":"10.1016\/j.survophthal.2011.10.001","volume":"56","author":"DJ Apple","year":"2011","unstructured":"Apple DJ, Escobar-Gomez M, Zaugg B, Kleinmann G, Borkenstein AF. Modern cataract surgery: unfinished business and unanswered questions. Surv Ophthalmol. 2011;56(6 Suppl):S3-53.","journal-title":"Surv Ophthalmol"},{"issue":"1","key":"1046_CR18","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1186\/s12886-022-02751-x","volume":"22","author":"Q Liu","year":"2022","unstructured":"Liu Q, Zhang S, Wang X, Liu J, Zhou G, Yuan X. Effects of intraocular lens anterior edge design on anterior capsule morphology changes following femtosecond laser-assisted capsulotomy. BMC Ophthalmol. 2022;22(1):515.","journal-title":"BMC Ophthalmol"},{"key":"1046_CR19","volume-title":"Ophthalmic implants\u2014intraocular lenses\u2014part 3: mechanical properties and test methods (ISO 11979-3:2012)","author":"International Organization for Standardization","year":"2012","unstructured":"International Organization for Standardization. Ophthalmic implants\u2014intraocular lenses\u2014part 3: mechanical properties and test methods (ISO 11979-3:2012). Geneva: ISO; 2012."},{"key":"1046_CR20","doi-asserted-by":"publisher","DOI":"10.1016\/j.exer.2021.108487","volume":"205","author":"IM Wormstone","year":"2021","unstructured":"Wormstone IM, Damm NB, Kelp M, Eldred JA. Assessment of intraocular lens\/capsular bag biomechanical interactions following cataract surgery in a human in vitro graded culture capsular bag model. Exp Eye Res. 2021;205: 108487.","journal-title":"Exp Eye Res"},{"issue":"1","key":"1046_CR21","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1001\/archopht.1992.01080130091032","volume":"110","author":"EI Assia","year":"1992","unstructured":"Assia EI, Apple DJ. Side-view analysis of the lens. I. The crystalline lens and the evacuated bag. Arch Ophthalmol. 1992;110(1):89\u201393.","journal-title":"Arch Ophthalmol"},{"issue":"11","key":"1046_CR22","doi-asserted-by":"publisher","first-page":"6847","DOI":"10.1167\/iovs.15-17228","volume":"56","author":"K Erb-Eigner","year":"2015","unstructured":"Erb-Eigner K, Hirnschall N, Hackl C, Schmidt C, Asbach P, Findl O. Predicting lens diameter: ocular biometry with high-resolution MRI. Investig Opthalmol Vis Sci. 2015;56(11):6847\u201354.","journal-title":"Investig Opthalmol Vis Sci"},{"issue":"3","key":"1046_CR23","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1159\/000519139","volume":"6","author":"AF Borkenstein","year":"2021","unstructured":"Borkenstein AF, Borkenstein E-M, Luedtke H, Schmid R. Optical bench analysis of 2 depth of focus intraocular lenses. Biomed Hub. 2021;6(3):77\u201385.","journal-title":"Biomed Hub"},{"issue":"1","key":"1046_CR24","doi-asserted-by":"publisher","first-page":"19646","DOI":"10.1038\/s41598-023-47102-y","volume":"13","author":"E Can","year":"2023","unstructured":"Can E, Senel EC, Holmstr\u00f6m STS, Pi\u00f1ero DP. Comparison of the optical behaviour of five different multifocal diffractive intraocular lenses in a model eye. Sci Rep. 2023;13(1):19646.","journal-title":"Sci Rep"},{"issue":"8","key":"1046_CR25","doi-asserted-by":"publisher","first-page":"532","DOI":"10.3928\/1081597X-20210518-03","volume":"37","author":"J Ruiz-Alcocer","year":"2021","unstructured":"Ruiz-Alcocer J, Mart\u00ednez-Alberquilla I, Rementer\u00eda-Capelo LA, de Gracia P, Lorente-Vel\u00e1zquez A. Changes in optical quality induced by tilt and decentration of a trifocal IOL and a novel extended depth of focus IOL in eyes with corneal myopic ablations. J Refract Surg. 2021;37(8):532\u20137.","journal-title":"J Refract Surg"},{"key":"1046_CR26","doi-asserted-by":"publisher","first-page":"933","DOI":"10.1177\/11206721221128864","volume":"33","author":"R Schmid","year":"2022","unstructured":"Schmid R, Luedtke H, Borkenstein AF. Effect of decentration and tilt on four novel extended range of vision intraocular lenses regarding far distance. Eur J Ophthalmol. 2022;33:933\u2013842. https:\/\/doi.org\/10.1177\/11206721221128864.","journal-title":"Eur J Ophthalmol"},{"issue":"12","key":"1046_CR27","doi-asserted-by":"publisher","first-page":"808","DOI":"10.3928\/1081597X-20171004-02","volume":"33","author":"T Tandogan","year":"2017","unstructured":"Tandogan T, Son HS, Choi CY, Knorz MC, Auffarth GU, Khoramnia R. Laboratory evaluation of the influence of decentration and pupil size on the optical performance of a monofocal, bifocal, and trifocal intraocular lens. J Refract Surg. 2017;33(12):808\u201312.","journal-title":"J Refract Surg"},{"key":"1046_CR28","doi-asserted-by":"publisher","first-page":"3915","DOI":"10.2147\/OPTH.S445461","volume":"17","author":"G \u0141abuz","year":"2023","unstructured":"\u0141abuz G, Yan W, Khoramnia R, Auffarth G. Optical-quality analysis and defocus-curve simulations of a novel hydrophobic trifocal intraocular lens. Clin Ophthalmol. 2023;17:3915\u201323.","journal-title":"Clin Ophthalmol"},{"issue":"8","key":"1046_CR29","doi-asserted-by":"publisher","first-page":"1142","DOI":"10.1097\/j.jcrs.0000000000000232","volume":"46","author":"T Kohnen","year":"2020","unstructured":"Kohnen T, Marchini G, Alfonso JF, et al. Innovative trifocal (quadrifocal) presbyopia-correcting IOLs: 1-year outcomes from an international multicenter study. J Cataract Refract Surg. 2020;46(8):1142\u20138.","journal-title":"J Cataract Refract Surg"},{"key":"1046_CR30","doi-asserted-by":"publisher","first-page":"949","DOI":"10.1177\/11206721221144928","volume":"33","author":"LA Rementer\u00eda-Capelo","year":"2022","unstructured":"Rementer\u00eda-Capelo LA, Contreras I, Garc\u00eda-P\u00e9rez JL, Bl\u00e1zquez V, Ruiz-Alcocer J. Visual performance and impact of residual refractive errors with trifocal intraocular lenses of different aspheric design. Eur J Ophthalmol. 2022;33:949\u201356. https:\/\/doi.org\/10.1177\/11206721221144928.","journal-title":"Eur J Ophthalmol"},{"key":"1046_CR31","doi-asserted-by":"publisher","first-page":"2277","DOI":"10.2147\/OPTH.S421185","volume":"17","author":"JO de Rojas","year":"2023","unstructured":"de Rojas JO, Sandoval HP, Potvin R, Solomon KD. Visual outcomes, quality of vision, patient satisfaction and spectacle independence after bilateral implantation of the Synergy\u2122 intraocular lens. Clin Ophthalmol. 2023;17:2277\u201385.","journal-title":"Clin Ophthalmol"},{"issue":"23","key":"1046_CR32","doi-asserted-by":"publisher","first-page":"7368","DOI":"10.3390\/jcm12237368","volume":"12","author":"KE Han","year":"2023","unstructured":"Han KE, Lee JE. Comparative evaluation of visual performance and patient satisfaction following cataract surgery: a retrospective analysis of an extended depth-of-focus intraocular lens and a diffractive multifocal lens with extended depth of focus. J Clin Med. 2023;12(23):7368.","journal-title":"J Clin Med"},{"issue":"1","key":"1046_CR33","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1186\/s12886-023-03207-6","volume":"23","author":"Y Nomura","year":"2023","unstructured":"Nomura Y, Ota Y, Fujita Y, Nishimura T, Bissen-Miyajima H, Minami K. Clinical outcomes in eyes with diffractive continuous depth-of-focus intraocular lenses enhanced for near vision: comparison with trifocal intraocular lenses. BMC Ophthalmol. 2023;23(1):475.","journal-title":"BMC Ophthalmol"},{"issue":"10","key":"1046_CR34","doi-asserted-by":"publisher","first-page":"654","DOI":"10.3928\/1081597X-20220825-01","volume":"38","author":"L Zhang","year":"2022","unstructured":"Zhang L, Schickhardt S, Auffarth GU. An experimental laboratory study using the Miyake-Apple posterior view technique to investigate the dynamics between capsular bags and different IOL models. J Refract Surg. 2022;38(10):654\u201360.","journal-title":"J Refract Surg"},{"key":"1046_CR35","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1016\/j.ajo.2020.12.021","volume":"225","author":"GO Waring","year":"2021","unstructured":"Waring GO, Chang DH, Rocha KM, Gouvea L, Penatti R. Correlation of intraoperative optical coherence tomography of crystalline lens diameter, thickness, and volume with biometry and age. Am J Ophthalmol. 2021;225:147\u201356.","journal-title":"Am J Ophthalmol"},{"issue":"4","key":"1046_CR36","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1097\/j.jcrs.0000000000001115","volume":"49","author":"X Gu","year":"2023","unstructured":"Gu X, Zhang M, Liu Z, et al. Building prediction models of clinically significant intraocular lens tilt and decentration for age-related cataract. J Cataract Refract Surg. 2023;49(4):385\u201391.","journal-title":"J Cataract Refract Surg"},{"key":"1046_CR37","doi-asserted-by":"publisher","first-page":"835","DOI":"10.1007\/s00417-023-06208-9","volume":"262","author":"A Langenbucher","year":"2023","unstructured":"Langenbucher A, Szentm\u00e1ry N, Cayless A, Wendelstein J, Hoffmann P. Prediction of IOL decentration, tilt and axial position using anterior segment OCT data. Graefes Arch Clin Exp Ophthalmol. 2023;262:835\u201346.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"issue":"10","key":"1046_CR38","doi-asserted-by":"publisher","first-page":"1775","DOI":"10.1016\/j.jcrs.2011.04.035","volume":"37","author":"M Modesti","year":"2011","unstructured":"Modesti M, Pasqualitto G, Appolloni R, Pecorella I, Sourdille P. Preoperative and postoperative size and movements of the lens capsular bag: ultrasound biomicroscopy analysis. J Cataract Refract Surg. 2011;37(10):1775\u201384.","journal-title":"J Cataract Refract Surg"}],"container-title":["Ophthalmology and Therapy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s40123-024-01046-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s40123-024-01046-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s40123-024-01046-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,14]],"date-time":"2024-11-14T13:13:36Z","timestamp":1731590016000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s40123-024-01046-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,9]]},"references-count":38,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2024,12]]}},"alternative-id":["1046"],"URL":"https:\/\/doi.org\/10.1007\/s40123-024-01046-2","relation":{},"ISSN":["2193-8245","2193-6528"],"issn-type":[{"value":"2193-8245","type":"print"},{"value":"2193-6528","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,10,9]]},"assertion":[{"value":"5 September 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 September 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 October 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Andreas F Borkenstein and Eva-Maria Borkenstein declare that they have no competing personal, financial, commercial, or academic conflicts of interest to declare that could have appeared to influence the work reported in this paper and agree with the contents of the manuscript.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of Interest"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors but is solely based on laboratory\/bench evaluations.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical Approval"}}]}}