{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T21:12:25Z","timestamp":1788642745696,"version":"build-2803163510"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T00:00:00Z","timestamp":1786665600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0"},{"start":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T00:00:00Z","timestamp":1786665600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ophthalmol Ther"],"published-print":{"date-parts":[[2026,10]]},"DOI":"10.1007\/s40123-026-01472-4","type":"journal-article","created":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T12:24:00Z","timestamp":1786710240000},"page":"3317-3334","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Modulation of Total Corneal Astigmatism, Corneal Thickness, and Corneal Higher-Order Aberrations Following Tear-Enhancing Drop Instillation: A Retrospective Comparative Study"],"prefix":"10.1007","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7826-2906","authenticated-orcid":false,"given":"Monika","family":"Sarnat-Kucharczyk","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aleksandra","family":"Ziemba","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna","family":"Hitnarowicz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ewa","family":"Mrukwa-Kominek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sudi","family":"Patel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,14]]},"reference":[{"key":"1472_CR1","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1080\/08820538.2022.2112699","volume":"38","author":"AS Nibandhe","year":"2023","unstructured":"Nibandhe AS, Donthineni PR. Understanding and optimizing ocular biometry for cataract surgery in dry eye disease: a review. Semin Ophthalmol. 2023;38:24\u201330. https:\/\/doi.org\/10.1080\/08820538.2022.2112699.","journal-title":"Semin Ophthalmol"},{"key":"1472_CR2","doi-asserted-by":"publisher","first-page":"1629","DOI":"10.2147\/OPTH.S406530","volume":"17","author":"K Biela","year":"2023","unstructured":"Biela K, Winiarczyk M, Borowicz D, Mackiewicz J. Dry eye disease as a cause of refractive errors after cataract surgery\u2014A systematic review. Clin Ophthalmol. 2023;17:1629\u201338. https:\/\/doi.org\/10.2147\/OPTH.S406530.","journal-title":"Clin Ophthalmol"},{"key":"1472_CR3","doi-asserted-by":"publisher","first-page":"597","DOI":"10.3390\/bioengineering11060597","volume":"11","author":"A Kawahara","year":"2024","unstructured":"Kawahara A. Management of dry eye disease for intraocular lens power calculation in cataract surgery: a systematic review. Bioengineering (Basel). 2024;11:597. https:\/\/doi.org\/10.3390\/bioengineering11060597.","journal-title":"Bioengineering (Basel)"},{"key":"1472_CR4","doi-asserted-by":"publisher","first-page":"103999","DOI":"10.1016\/j.jfo.2023.04.016","volume":"47","author":"F Yang","year":"2024","unstructured":"Yang F, Yang L, Ning X, Liu J, Wang J. Effect of dry eye on the reliability of keratometry for cataract surgery planning. J Fr Ophtalmol. 2024;47:103999. https:\/\/doi.org\/10.1016\/j.jfo.2023.04.016.","journal-title":"J Fr Ophtalmol"},{"key":"1472_CR5","doi-asserted-by":"publisher","first-page":"1672","DOI":"10.1016\/j.jcrs.2015.01.016","volume":"41","author":"AT Epitropoulos","year":"2015","unstructured":"Epitropoulos AT, Matossian C, Berdy GJ, Malhotra RP, Potvin R. Effect of tear osmolarity on repeatability of keratometry for cataract surgery planning. J Cataract Refract Surg. 2015;41:1672\u20137. https:\/\/doi.org\/10.1016\/j.jcrs.2015.01.016.","journal-title":"J Cataract Refract Surg"},{"key":"1472_CR6","doi-asserted-by":"publisher","first-page":"1596","DOI":"10.1016\/j.jcrs.2017.10.033","volume":"43","author":"J Chuang","year":"2017","unstructured":"Chuang J, Shih KC, Chan TC, Wan KH, Jhanji V, Tong L. Preoperative optimization of ocular surface disease before cataract surgery. J Cataract Refract Surg. 2017;43:1596\u2013607. https:\/\/doi.org\/10.1016\/j.jcrs.2017.10.033.","journal-title":"J Cataract Refract Surg"},{"key":"1472_CR7","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1097\/ICU.0000000000000814","volume":"33","author":"X He","year":"2022","unstructured":"He X, Huang AS, Jeng BH. Optimizing the ocular surface prior to cataract surgery. Curr Opin Ophthalmol. 2022;33:9\u201314. https:\/\/doi.org\/10.1097\/ICU.0000000000000814.","journal-title":"Curr Opin Ophthalmol"},{"key":"1472_CR8","doi-asserted-by":"publisher","first-page":"840","DOI":"10.1177\/1120672120929958","volume":"30","author":"K Naderi","year":"2020","unstructured":"Naderi K, Gormley J, O\u2019Brart D. Cataract surgery and dry eye disease: a review. Eur J Ophthalmol. 2020;30:840\u201355. https:\/\/doi.org\/10.1177\/1120672120929958.","journal-title":"Eur J Ophthalmol"},{"key":"1472_CR9","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-021-02129-5","volume":"21","author":"J Kim","year":"2021","unstructured":"Kim J, Kim MK, Ha Y, Paik HJ, Kim DH. Improved accuracy of intraocular lens power calculation by preoperative management of dry eye disease. BMC Ophthalmol. 2021;21:364. https:\/\/doi.org\/10.1186\/s12886-021-02129-5.","journal-title":"BMC Ophthalmol"},{"key":"1472_CR10","doi-asserted-by":"publisher","first-page":"2697","DOI":"10.1007\/s40123-025-01251-7","volume":"14","author":"G Coco","year":"2025","unstructured":"Coco G, Messmer EM, Starr CE, Pereira-Gomes JA, Lazreg S, Budimlija N, et al. A practical approach for optimizing ocular surface status before cataract surgery to improve visual outcomes and reduce the risk of postoperative dry eye. Ophthalmol Ther. 2025;14:2697\u2013733. https:\/\/doi.org\/10.1007\/s40123-025-01251-7.","journal-title":"Ophthalmol Ther"},{"key":"1472_CR11","doi-asserted-by":"publisher","first-page":"151","DOI":"10.2147\/OPTH.S448168","volume":"18","author":"C Nilsen","year":"2024","unstructured":"Nilsen C, Gundersen M, Graae Jensen P, Gundersen KG, Potvin R, Utheim \u00d8A, et al. The significance of dry eye signs on preoperative keratometry measurements in patients scheduled for cataract surgery. Clin Ophthalmol. 2024;18:151\u201361. https:\/\/doi.org\/10.2147\/OPTH.S448168.","journal-title":"Clin Ophthalmol"},{"key":"1472_CR12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.ajo.2020.08.024","volume":"221","author":"V R\u00f6ggla","year":"2021","unstructured":"R\u00f6ggla V, Leydolt C, Schartm\u00fcller D, Schwarzenbacher L, Meyer E, Abela-Formanek C, et al. Influence of artificial tears on keratometric measurements in cataract patients. Am J Ophthalmol. 2021;221:1\u20138. https:\/\/doi.org\/10.1016\/j.ajo.2020.08.024.","journal-title":"Am J Ophthalmol"},{"key":"1472_CR13","doi-asserted-by":"publisher","first-page":"3679","DOI":"10.2147\/OPTH.S325659","volume":"15","author":"JA Hovanesian","year":"2021","unstructured":"Hovanesian JA, Berdy GJ, Epitropoulos A, Holladay JT. Effect of cyclosporine 0.09% treatment on accuracy of preoperative biometry and higher order aberrations in dry eye patients undergoing cataract surgery. Clin Ophthalmol. 2021;15:3679\u201386. https:\/\/doi.org\/10.2147\/OPTH.S325659.","journal-title":"Clin Ophthalmol"},{"key":"1472_CR14","doi-asserted-by":"publisher","first-page":"2709","DOI":"10.2147\/OPTH.S264520","volume":"14","author":"J Hovanesian","year":"2020","unstructured":"Hovanesian J, Epitropoulos A, Donnenfeld ED, Holladay JT. The effect of lifitegrast on refractive accuracy and symptoms in dry eye patients undergoing cataract surgery. Clin Ophthalmol. 2020;14:2709\u201316. https:\/\/doi.org\/10.2147\/OPTH.S264520.","journal-title":"Clin Ophthalmol"},{"key":"1472_CR15","doi-asserted-by":"publisher","first-page":"706","DOI":"10.1097\/j.jcrs.0000000000000499","volume":"47","author":"Z Nayer","year":"2021","unstructured":"Nayer Z, Bhat A, Sohal PK, Murdock B, Watson SH, Belyea DA. Effect of eyedrops and applanation tonometry on optical biometry. J Cataract Refract Surg. 2021;47:706\u201312. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000499.","journal-title":"J Cataract Refract Surg"},{"key":"1472_CR16","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1097\/00003226-199907000-00002","volume":"18","author":"Z Liu","year":"1999","unstructured":"Liu Z, Pflugfelder SC. Corneal thickness is reduced in dry eye. Cornea. 1999;18:403\u20137. https:\/\/doi.org\/10.1097\/00003226-199907000-00002.","journal-title":"Cornea"},{"key":"1472_CR17","doi-asserted-by":"publisher","first-page":"477","DOI":"10.1097\/00003226-200007000-00015","volume":"19","author":"KK Nichols","year":"2000","unstructured":"Nichols KK, Nichols JJ, Zadnik K. Frequency of dry eye diagnostic test procedures used in various modes of ophthalmic practice. Cornea. 2000;19:477\u201382. https:\/\/doi.org\/10.1097\/00003226-200007000-00015.","journal-title":"Cornea"},{"key":"1472_CR18","doi-asserted-by":"publisher","first-page":"179","DOI":"10.3390\/medicina62010179","volume":"62","author":"V Lacmanovi\u0107 Lon\u010dar","year":"2026","unstructured":"Lacmanovi\u0107 Lon\u010dar V, Mikuli\u0107 D, Aljinovi\u0107-Vu\u010di\u0107 V, Vatavuk Z, Petric Vickovi\u0107 I. Impact of dry eye disease and lipid-containing artificial tears on keratometric reproducibility and intraocular lens calculation in cataract patients. Medicina. 2026;62:179. https:\/\/doi.org\/10.3390\/medicina62010179.","journal-title":"Medicina"},{"key":"1472_CR19","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-94568-9","volume":"11","author":"JE Ding","year":"2021","unstructured":"Ding JE, Kim YH, Yi SM, Graham AD, Li W, Lin MC. Ocular surface cooling rate associated with tear film characteristics and the maximum interblink period. Sci Rep. 2021;11:15030. https:\/\/doi.org\/10.1038\/s41598-021-94568-9.","journal-title":"Sci Rep"},{"key":"1472_CR20","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1016\/j.clae.2020.01.002","volume":"43","author":"E Mrukwa Kominek","year":"2020","unstructured":"Mrukwa Kominek E, Sarnat-Kucharczyk M, Patel S. The impact of exposure on the magnitude of astigmatism formed within the precorneal tear film over the central optical zone of the cornea in ocular surface disease. Contact Lens Anterior Eye. 2020;43:261\u20137. https:\/\/doi.org\/10.1016\/j.clae.2020.01.002.","journal-title":"Contact Lens Anterior Eye"},{"key":"1472_CR21","doi-asserted-by":"publisher","first-page":"8","DOI":"10.3390\/vision8010008","volume":"8","author":"S Ka\u0161telan","year":"2024","unstructured":"Ka\u0161telan S, Gabri\u0107 K, Mikuli\u010di\u0107 M, Mrazovac Zimak D, Karabati\u0107 M, Gverovi\u0107 Antunica A. The influence of tear film quality on visual function. Vision (Basel). 2024;8:8. https:\/\/doi.org\/10.3390\/vision8010008.","journal-title":"Vision (Basel)."},{"key":"1472_CR22","doi-asserted-by":"publisher","first-page":"993","DOI":"10.1016\/j.visres.2005.09.021","volume":"46","author":"M Dubbelman","year":"2006","unstructured":"Dubbelman M, Sicam VADP, Van der Heijde GL. The shape of the anterior and posterior surface of the aging human cornea. Vision Res. 2006;46:993\u20131001. https:\/\/doi.org\/10.1016\/j.visres.2005.09.021.","journal-title":"Vision Res"},{"key":"1472_CR23","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1097\/ICO.0000000000000358","volume":"34","author":"D Schmidl","year":"2015","unstructured":"Schmidl D, Schmetterer L, Witkowska KJ, Unterhuber A, dos Santos VA, Kaya S, et al. Tear film thickness after treatment with artificial tears in patients with moderate dry eye disease. Cornea. 2015;34:421\u20136. https:\/\/doi.org\/10.1097\/ICO.0000000000000358.","journal-title":"Cornea"},{"key":"1472_CR24","doi-asserted-by":"publisher","first-page":"30","DOI":"10.11648\/j.ijovs.20220701.15","volume":"7","author":"AA Anas","year":"2022","unstructured":"Anas AA, Rajab M. The effect of artificial tear treatment on central corneal thickness in dry eye. Int J Ophthalmol Vis Sci. 2022;7:30\u20132. https:\/\/doi.org\/10.11648\/j.ijovs.20220701.15.","journal-title":"Int J Ophthalmol Vis Sci."},{"key":"1472_CR25","doi-asserted-by":"publisher","first-page":"e310","DOI":"10.1111\/aos.17487","volume":"103","author":"T Schug","year":"2025","unstructured":"Schug T, Kohnen T, Kaiser KP, Lwowski C. Influence of artificial tears on corneal parameter measurement using three different devices: Keratometry and Scheimpflug technology, a randomized trial. Acta Ophthalmol. 2025;103:e310\u20137. https:\/\/doi.org\/10.1111\/aos.17487.","journal-title":"Acta Ophthalmol"},{"key":"1472_CR26","doi-asserted-by":"publisher","first-page":"1023","DOI":"10.1016\/s0886-3350(97)80075-2","volume":"23","author":"KD Novak","year":"1997","unstructured":"Novak KD, Kohnen T, Chang-Godinich A, Soper BA, Kennedy P, Wang Q, et al. Changes in computerized videokeratography induced by artificial tears. J Cataract Refract Surg. 1997;23:1023\u20138. https:\/\/doi.org\/10.1016\/s0886-3350(97)80075-2.","journal-title":"J Cataract Refract Surg"},{"key":"1472_CR27","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1111\/j.1475-1313.2005.00336.x","volume":"25","author":"K Karadayi","year":"2005","unstructured":"Karadayi K, Ciftci F, Akin T, Bilge AH. Increase in central corneal thickness in dry and normal eyes with application of artificial tears: a new diagnostic and follow-up criterion for dry eye. Ophthalmic Physiol Opt Optometrists. 2005;25:485\u201391. https:\/\/doi.org\/10.1111\/j.1475-1313.2005.00336.x.","journal-title":"Ophthalmic Physiol Opt Optometrists"},{"key":"1472_CR28","doi-asserted-by":"publisher","first-page":"615","DOI":"10.1001\/archopht.118.5.615","volume":"118","author":"RM Schiffman","year":"2000","unstructured":"Schiffman RM, Christianson MD, Jacobsen G, Hirsch JD, Reis BL. Reliability and validity of the ocular surface disease index. Arch Ophthalmol Chicago, Ill\u202f: 1960. 2000;118:615\u201321. https:\/\/doi.org\/10.1001\/archopht.118.5.615.","journal-title":"Arch Ophthalmol. Chicago, Ill.\u202f: 1960"},{"key":"1472_CR29","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-025-95801-5","volume":"15","author":"Y Chen","year":"2025","unstructured":"Chen Y, Li M, Chen J, Zhao J, Pazo EE, Qin G, et al. To evaluate the effects of artificial tears on ocular biological parameters in dry eye and non-dry eye patients. Sci Rep. 2025;15:12392. https:\/\/doi.org\/10.1038\/s41598-025-95801-5.","journal-title":"Sci Rep"},{"key":"1472_CR30","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0328894","volume":"20","author":"A Langenbucher","year":"2025","unstructured":"Langenbucher A, Szentm\u00e1ry N, Cayless A, Schartm\u00fcller D, Lisy M, Menapace R, et al. Repeatability of corneal measurements from the Casia2 anterior segment tomographer in a cataractous population. PLoS ONE. 2025;20:e0328894. https:\/\/doi.org\/10.1371\/journal.pone.0328894.","journal-title":"PLoS ONE"},{"key":"1472_CR31","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/s0886-3350(00)00798-7","volume":"27","author":"N Alpins","year":"2001","unstructured":"Alpins N. Astigmatism analysis by the Alpins method. J Cataract Refract Surg. 2001;27:31\u201349. https:\/\/doi.org\/10.1016\/s0886-3350(00)00798-7.","journal-title":"J Cataract Refract Surg"},{"key":"1472_CR32","doi-asserted-by":"publisher","first-page":"1342056","DOI":"10.1155\/2016\/1342056","volume":"2016","author":"N Lu","year":"2016","unstructured":"Lu N, Lin F, Huang Z, He Q, Han W. Changes of corneal wavefront aberrations in dry eye patients after treatment with artificial lubricant drops. J Ophthalmol. 2016;2016:1342056. https:\/\/doi.org\/10.1155\/2016\/1342056.","journal-title":"J Ophthalmol"},{"key":"1472_CR33","doi-asserted-by":"publisher","first-page":"1649","DOI":"10.1016\/j.jcrs.2004.02.041","volume":"30","author":"R Mont\u00e9s-Mic\u00f3","year":"2004","unstructured":"Mont\u00e9s-Mic\u00f3 R, C\u00e1liz A, Ali\u00f3 JL. Changes in ocular aberrations after instillation of artificial tears in dry-eye patients. J Cataract Refract Surg. 2004;30:1649\u201352. https:\/\/doi.org\/10.1016\/j.jcrs.2004.02.041.","journal-title":"J Cataract Refract Surg"},{"key":"1472_CR34","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1016\/j.optom.2018.01.004","volume":"11","author":"G Montani","year":"2018","unstructured":"Montani G, Murphy PJ, Patel S. Immediate effect of a tear enhancer and meibomian gland expression on the corneal surface and whole eye higher order aberrations. J Optom. 2018;11:223\u201331. https:\/\/doi.org\/10.1016\/j.optom.2018.01.004.","journal-title":"J Optom"},{"key":"1472_CR35","doi-asserted-by":"publisher","first-page":"2165","DOI":"10.1007\/s40123-025-01205-z","volume":"14","author":"J-M S\u00e1nchez-Gonz\u00e1lez","year":"2025","unstructured":"S\u00e1nchez-Gonz\u00e1lez J-M, S\u00e1nchez-Gonz\u00e1lez MC, De-Hita-Cantalejo C, Nascimento H, Martinez-Perez C. Immediate impact of artificial tear composition on optical aberrations: a comparative study of lipid and non-lipid hydroxypropyl guar formulations. Ophthalmol Ther. 2025;14:2165\u201378. https:\/\/doi.org\/10.1007\/s40123-025-01205-z.","journal-title":"Ophthalmol Ther"},{"key":"1472_CR36","doi-asserted-by":"publisher","first-page":"404","DOI":"10.1097\/01.ico.0000214205.29823.f6","volume":"25","author":"L Gao","year":"2006","unstructured":"Gao L, Fan H, Cheng ACK, Wang Z, Lam DSC. The effects of eye drops on corneal thickness in adult myopia. Cornea. 2006;25:404\u20137. https:\/\/doi.org\/10.1097\/01.ico.0000214205.29823.f6.","journal-title":"Cornea"},{"key":"1472_CR37","doi-asserted-by":"publisher","first-page":"1305","DOI":"10.1097\/ICO.0b013e31829b21d1","volume":"32","author":"J Niimi","year":"2013","unstructured":"Niimi J, Tan B, Chang J, Zhou Y, Ghanekar A, Wong M, et al. Diurnal pattern of tear osmolarity and its relationship to corneal thickness and deswelling. Cornea. 2013;32:1305\u201310. https:\/\/doi.org\/10.1097\/ICO.0b013e31829b21d1.","journal-title":"Cornea"},{"key":"1472_CR38","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0230589","volume":"15","author":"A Wyl\u0119ga\u0142a","year":"2020","unstructured":"Wyl\u0119ga\u0142a A, Mazur R, Bolek B, Wyl\u0119ga\u0142a E. Reproducibility, and repeatability of corneal topography measured by Revo NX, Galilei G6 and Casia 2 in normal eyes. PLoS ONE. 2020;15:e0230589. https:\/\/doi.org\/10.1371\/journal.pone.0230589.","journal-title":"PLoS ONE"}],"container-title":["Ophthalmology and Therapy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s40123-026-01472-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s40123-026-01472-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s40123-026-01472-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T21:02:47Z","timestamp":1788642167000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s40123-026-01472-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,14]]},"references-count":38,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2026,10]]}},"alternative-id":["1472"],"URL":"https:\/\/doi.org\/10.1007\/s40123-026-01472-4","relation":{},"ISSN":["2193-8245","2193-6528"],"issn-type":[{"value":"2193-8245","type":"print"},{"value":"2193-6528","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,14]]},"assertion":[{"value":"28 May 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 July 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 August 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Monika Sarnat-Kucharczyk, Sudi Patel, Aleksandra Ziemba, Anna Hitnarowicz, and Ewa Mrukwa-Kominek have nothing to disclose.","order":1,"name":"Ethics","label":"Conflict of Interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The Bioethics Committee of the Medical University of Silesia in Katowice (Katowice, Poland) confirmed that the retrospective analysis of medical records does not constitute a medical experiment and therefore does not require formal approval by the Committee (reference No. BNW\/NWN\/0052\/KB\/334\/25, dated 23 November 2025). The study was conducted in accordance with the ethical principles of the Declaration of Helsinki. The study was conducted in accordance with applicable regulations regarding personal data protection and patients\u2019 rights, and the data were used exclusively for research purposes. Patient consent was not required because the study was based exclusively on anonymized retrospective clinical data collected during routine clinical care.","order":2,"name":"Ethics","label":"Ethical Approval","group":{"name":"EthicsHeading","label":"Declarations"}}]}}