{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T18:50:29Z","timestamp":1770749429448,"version":"3.50.0"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2022,1,14]],"date-time":"2022-01-14T00:00:00Z","timestamp":1642118400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2022,1,14]],"date-time":"2022-01-14T00:00:00Z","timestamp":1642118400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Ultrasound"],"DOI":"10.1007\/s40477-021-00643-2","type":"journal-article","created":{"date-parts":[[2022,1,14]],"date-time":"2022-01-14T12:02:45Z","timestamp":1642161765000},"page":"765-771","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Power Doppler artifacts in evaluating inflammatory arthritis of small joints: comparison with a superb microvascular imaging technique"],"prefix":"10.1007","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4830-1497","authenticated-orcid":false,"given":"Goda","family":"Seskute","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0346-1510","authenticated-orcid":false,"given":"Marija","family":"Montvydaite","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3795-7741","authenticated-orcid":false,"given":"Irena","family":"Butrimiene","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,1,14]]},"reference":[{"key":"643_CR1","doi-asserted-by":"publisher","DOI":"10.1007\/s40477-020-00489-0","author":"E Smith","year":"2020","unstructured":"Smith E, Azzopardi C, Thaker S, Botchu R, Gupta H (2020) Power Doppler in musculoskeletal ultrasound: uses, pitfalls and principles to overcome its shortcomings. J Ultrasound. https:\/\/doi.org\/10.1007\/s40477-020-00489-0","journal-title":"J Ultrasound"},{"issue":"2","key":"643_CR2","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1136\/ard.2007.078451","volume":"67","author":"ST Torp-Pedersen","year":"2007","unstructured":"Torp-Pedersen ST, Terslev L (2007) Settings and artefacts relevant in colour\/power Doppler ultrasound in rheumatology. Ann Rheum Dis 67(2):143\u2013149. https:\/\/doi.org\/10.1136\/ard.2007.078451","journal-title":"Ann Rheum Dis"},{"key":"643_CR3","doi-asserted-by":"publisher","DOI":"10.1155\/2015\/325909","author":"S Bhasin","year":"2015","unstructured":"Bhasin S, Cheung PP (2015) The role of power Doppler ultrasonography as disease activity marker in rheumatoid arthritis. Dis Markers. https:\/\/doi.org\/10.1155\/2015\/325909","journal-title":"Dis Markers"},{"issue":"6","key":"643_CR4","doi-asserted-by":"publisher","first-page":"976","DOI":"10.1093\/rheumatology\/ker433","volume":"51","author":"F Porta","year":"2012","unstructured":"Porta F, Radunovic G, Vlad V et al (2012) The role of Doppler ultrasound in rheumatic diseases. Rheumatology 51(6):976\u2013982. https:\/\/doi.org\/10.1093\/rheumatology\/ker433","journal-title":"Rheumatology"},{"issue":"2","key":"643_CR5","doi-asserted-by":"publisher","first-page":"98","DOI":"10.14366\/usg.17043","volume":"37","author":"AY Park","year":"2018","unstructured":"Park AY, Seo BK (2018) Up-to-date Doppler techniques for breast tumor vascularity: superb microvascular imaging and contrast-enhanced ultrasound. Ultrasonography 37(2):98\u2013106. https:\/\/doi.org\/10.14366\/usg.17043","journal-title":"Ultrasonography"},{"key":"643_CR6","unstructured":"Hata J (2014) Seeing the unseen. New techniques in vascular imaging. Otawara: Toshiba Med Rev 1\u20138. https:\/\/www.toshiba-medical.eu\/eu\/wpcontent\/uploads\/sites\/2\/2014\/09\/WP_OI_MOIUS0070EA_SMI_Hata_03_2014.pdf"},{"key":"643_CR7","doi-asserted-by":"publisher","first-page":"45","DOI":"10.4103\/jcis.jcis_79_17","volume":"7","author":"S Artul","year":"2017","unstructured":"Artul S, Nseir W, Armaly Z, Soudack M (2017) Superb microvascular imaging: added value and novel applications. J Clin Imaging Sci 7:45. https:\/\/doi.org\/10.4103\/jcis.jcis_79_17","journal-title":"J Clin Imaging Sci"},{"issue":"43","key":"643_CR8","doi-asserted-by":"publisher","first-page":"7765","DOI":"10.3748\/wjg.v23.i43.7765","volume":"23","author":"MN He","year":"2017","unstructured":"He MN, Lv K, Jiang YX, Jiang TA (2017) Application of superb microvascular imaging in focal liver lesions. World J Gastroenterol 23(43):7765\u20137775. https:\/\/doi.org\/10.3748\/wjg.v23.i43.7765","journal-title":"World J Gastroenterol"},{"issue":"2","key":"643_CR9","doi-asserted-by":"publisher","first-page":"497","DOI":"10.1148\/rg.242035130","volume":"24","author":"SC Campbell","year":"2004","unstructured":"Campbell SC, Cullinan JA, Rubens DJ (2004) Slow flow or no flow? Color and power Doppler US pitfalls in the abdomen and pelvis. Radiographics 24(2):497\u2013506. https:\/\/doi.org\/10.1148\/rg.242035130","journal-title":"Radiographics"},{"key":"643_CR10","volume-title":"Essential applications of musculoskeletal ultrasound in rheumatology: expert consult premium edition: enhanced online features and print","author":"RJ Wakefield","year":"2010","unstructured":"Wakefield RJ, D\u2019Agostino MA (2010) Essential applications of musculoskeletal ultrasound in rheumatology: expert consult premium edition: enhanced online features and print, 1st edn. Saunders, London","edition":"1"},{"key":"643_CR11","doi-asserted-by":"publisher","DOI":"10.1007\/3-540-28903-8_2","volume-title":"Doppler ultrasound in obstetrics and gynecology","author":"D Maulik","year":"2005","unstructured":"Maulik D (2005) Physical principles of Doppler ultrasonography. In: Maulik D (ed) Doppler ultrasound in obstetrics and gynecology. Springer, Berlin. https:\/\/doi.org\/10.1007\/3-540-28903-8_2"},{"issue":"3","key":"643_CR12","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1148\/rg.243035139","volume":"24","author":"JB Kruskal","year":"2004","unstructured":"Kruskal JB, Newman PA, Sammons LG, Kane RA (2004) Optimizing Doppler and color flow US: application to hepatic sonography. Radiographics 24(3):657\u2013675. https:\/\/doi.org\/10.1148\/rg.243035139","journal-title":"Radiographics"},{"issue":"9","key":"643_CR13","doi-asserted-by":"publisher","first-page":"1868","DOI":"10.1016\/j.ultrasmedbio.2017.04.027","volume":"43","author":"M Van der Ven","year":"2017","unstructured":"Van der Ven M, Luime JJ, van der Velden LL, Bosch JG, Hazes JM, Vos HJ (2017) High-frame-rate power doppler ultrasound is more sensitive than conventional power Doppler in detecting rheumatic vascularisation. Ultrasound Med Biol 43(9):1868\u20131879. https:\/\/doi.org\/10.1016\/j.ultrasmedbio.2017.04.027","journal-title":"Ultrasound Med Biol"},{"issue":"S3","key":"643_CR14","doi-asserted-by":"publisher","first-page":"S318","DOI":"10.1007\/pl00014064","volume":"9","author":"JM Rubin","year":"1999","unstructured":"Rubin JM (1999) Power Doppler. Eur Radiol 9(S3):S318\u2013S322. https:\/\/doi.org\/10.1007\/pl00014064","journal-title":"Eur Radiol"},{"issue":"1","key":"643_CR15","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1148\/radiology.202.1.8988227","volume":"202","author":"C Martinoli","year":"1997","unstructured":"Martinoli C, Derchi LE (1997) Gain setting in power Doppler US. Radiology 202(1):284\u2013285. https:\/\/doi.org\/10.1148\/radiology.202.1.8988227","journal-title":"Radiology"},{"issue":"8","key":"643_CR16","doi-asserted-by":"publisher","first-page":"1308","DOI":"10.1007\/s003300100914","volume":"11","author":"A Nilsson","year":"2001","unstructured":"Nilsson A (2001) Artefacts in sonography and Doppler. Eur Radiol 11(8):1308\u20131315. https:\/\/doi.org\/10.1007\/s003300100914","journal-title":"Eur Radiol"},{"issue":"6","key":"643_CR17","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1016\/j.rcl.2006.10.014","volume":"44","author":"DJ Rubens","year":"2006","unstructured":"Rubens DJ, Bhatt S, Nedelka S, Cullinan J (2006) Doppler artifacts and pitfalls. Radiol Clin N Am 44(6):805\u2013835. https:\/\/doi.org\/10.1016\/j.rcl.2006.10.014","journal-title":"Radiol Clin N Am"},{"issue":"10","key":"643_CR18","doi-asserted-by":"publisher","first-page":"1885","DOI":"10.1007\/s00296-018-4112-3","volume":"38","author":"X Yu","year":"2018","unstructured":"Yu X, Li Z, Ren M, Xi J, Wu J, Ji Y (2018) Superb microvascular imaging (SMI) for evaluating hand joint lesions in patients with rheumatoid arthritis in clinical remission. Rheumatol Int 38(10):1885\u20131890. https:\/\/doi.org\/10.1007\/s00296-018-4112-3","journal-title":"Rheumatol Int"},{"issue":"3","key":"643_CR19","doi-asserted-by":"publisher","first-page":"1046","DOI":"10.1007\/s00330-017-5016-4","volume":"28","author":"AKP Lim","year":"2017","unstructured":"Lim AKP, Satchithananda K, Dick EA, Abraham S, Cosgrove DO (2017) Microflow imaging: New Doppler technology to detect low-grade inflammation in patients with arthritis. Eur Radiol 28(3):1046\u20131053. https:\/\/doi.org\/10.1007\/s00330-017-5016-4","journal-title":"Eur Radiol"},{"issue":"01","key":"643_CR20","doi-asserted-by":"publisher","first-page":"003","DOI":"10.1055\/s-0034-1365830","volume":"18","author":"D Melville","year":"2014","unstructured":"Melville D, Scalcione L, Gimber L, Lorenz E, Witte R, Taljanovic M (2014) Artifacts in musculoskeletal ultrasonography. Semin Musculoskelet Radiol 18(01):003\u2013011. https:\/\/doi.org\/10.1055\/s-0034-1365830","journal-title":"Semin Musculoskelet Radiol"}],"container-title":["Journal of Ultrasound"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s40477-021-00643-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s40477-021-00643-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s40477-021-00643-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,24]],"date-time":"2022-08-24T17:40:11Z","timestamp":1661362811000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s40477-021-00643-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,14]]},"references-count":20,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2022,9]]}},"alternative-id":["643"],"URL":"https:\/\/doi.org\/10.1007\/s40477-021-00643-2","relation":{},"ISSN":["1876-7931"],"issn-type":[{"value":"1876-7931","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,14]]},"assertion":[{"value":"24 August 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 November 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 January 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have declared no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Approved by The Vilnius Regional Biomedical Research Ethics Committee, no. 2020\/6-1235-720.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}