{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T18:27:31Z","timestamp":1791829651445,"version":"4.3.4"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2025,8,21]],"date-time":"2025-08-21T00:00:00Z","timestamp":1755734400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,8,21]],"date-time":"2025-08-21T00:00:00Z","timestamp":1755734400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Alma Mater Studiorum - Universit\u00e0 di Bologna"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Ultrasound"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>B-Flow technology represents a significant advancement in vascular ultrasound imaging, offering high-resolution visualization of blood flow without the limitations inherent in conventional Doppler techniques. By employing Coded Excitation and Tissue-Blood Equalization (TBE) technologies, B-Flow enhances the detection of low-velocity and microvascular blood flow while minimizing aliasing artifacts and angle dependency. This innovative technique proves especially useful in abdominal ultrasound, enabling the accurate assessment of vascularization in organs such as the liver, kidneys, pancreas, spleen, and bowel. B-Flow\u2019s ability to depict fine vascular details is particularly beneficial in evaluating focal lesions, vascular malformations, portal hypertension, and transplant perfusion. Furthermore, the technique\u2019s application extends to both parenchymal and vascular pathologies, demonstrating significant advantages over traditional Doppler methods in terms of spatial resolution and real-time flow visualization. This pictorial essay aims to describe the technological basis of the B-Flow technique, highlighting its advantages and disadvantages, as well as the main clinical applications in abdominal diagnostics.<\/jats:p>","DOI":"10.1007\/s40477-025-01068-x","type":"journal-article","created":{"date-parts":[[2025,8,21]],"date-time":"2025-08-21T12:48:44Z","timestamp":1755780524000},"page":"1017-1030","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["B-flow imaging in abdominal ultrasound: a pictorial essay"],"prefix":"10.1007","volume":"28","author":[{"given":"Marco","family":"Becciolini","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alice","family":"Brighenti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Valeria","family":"Tiraferri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Corvino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9303-7790","authenticated-orcid":false,"given":"Andrea","family":"Boccatonda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carla","family":"Serra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,8,21]]},"reference":[{"issue":"6","key":"1068_CR1","doi-asserted-by":"publisher","first-page":"W522","DOI":"10.2214\/AJR.06.1161","volume":"188","author":"RH Wachsberg","year":"2007","unstructured":"Wachsberg RH (2007) B-flow imaging of the hepatic vasculature: correlation with color Doppler sonography. AJR Am J Roentgenol 188(6):W522\u2013W533","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"1068_CR2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/1097-0096(200101)29:1<1::AID-JCU1>3.0.CO;2-F","volume":"29","author":"J Furuse","year":"2001","unstructured":"Furuse J, Maru Y, Mera K, Sumi H, Yoshino M, Yokoyama Y et al (2001) Visualization of blood flow in hepatic vessels and hepatocellular carcinoma using B-flow sonography. J Clin Ultrasound 29(1):1\u20136","journal-title":"J Clin Ultrasound"},{"issue":"98","key":"1068_CR3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.15557\/JoU.2024.0029","volume":"24","author":"EA Babington","year":"2024","unstructured":"Babington EA, Amedu C, Anyasor E, Reeve R (2024) Non-contrast ultrasound assessment of blood flow in clinical practice. J Ultrason 24(98):1\u20139","journal-title":"J Ultrason"},{"issue":"9","key":"1068_CR4","doi-asserted-by":"publisher","first-page":"2345","DOI":"10.1016\/j.ultrasmedbio.2016.04.010","volume":"42","author":"F D'Abate","year":"2016","unstructured":"D\u2019Abate F, Ramachandran V, Young MA, Farrah J, Ahmed MH, Jones K et al (2016) B-flow imaging in lower limb peripheral arterial disease and bypass graft ultrasonography. Ultrasound Med Biol 42(9):2345\u20132351","journal-title":"Ultrasound Med Biol"},{"key":"1068_CR5","unstructured":"Leiderer M CA, Botz B, et al (2024) B-Flow. Radiopaedia.org (Accessed on 15 Mar 2025)"},{"issue":"2","key":"1068_CR6","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1007\/s12328-023-01914-7","volume":"17","author":"R Yano","year":"2024","unstructured":"Yano R, Hirooka M, Nakamura Y, Imai Y, Koizumi Y, Watanabe T et al (2024) A case of hepatocellular carcinoma with pseudoaneurysm formation upon lenvatinib administration. Clin J Gastroenterol 17(2):319\u2013326","journal-title":"Clin J Gastroenterol"},{"key":"1068_CR7","doi-asserted-by":"publisher","DOI":"10.3390\/diagnostics12112818","author":"F Wang","year":"2022","unstructured":"Wang F, Numata K, Nihonmatsu H, Chuma M, Ideno N, Nozaki A et al (2022) Added value of ultrasound-based multimodal imaging to diagnose hepatic sclerosed hemangioma before biopsy and resection. Diagnostics. https:\/\/doi.org\/10.3390\/diagnostics12112818","journal-title":"Diagnostics"},{"issue":"4","key":"1068_CR8","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1007\/s10396-013-0442-7","volume":"40","author":"N Matsumoto","year":"2013","unstructured":"Matsumoto N, Ogawa M, Miura T, Shiozawa K, Abe M, Nakagawara H et al (2013) B-flow imaging of vascular structure for the diagnosis of liver tumor. J Med Ultrason 40(4):409\u201315","journal-title":"J Med Ultrason"},{"issue":"2","key":"1068_CR9","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1007\/s40477-017-0240-y","volume":"20","author":"G Bonacchi","year":"2017","unstructured":"Bonacchi G, Becciolini M, Seghieri M (2017) Superb microvascular imaging: a potential tool in the detection of FNH. J Ultrasound 20(2):179\u2013180","journal-title":"J Ultrasound"},{"issue":"1","key":"1068_CR10","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1007\/s10396-021-01167-2","volume":"49","author":"Y Ohyama","year":"2022","unstructured":"Ohyama Y, Naganuma H, Ishida H, Hoshino T (2022) Portal vein gas in a patient with acute cholangitis: report of a case with emphasis on B-flow imaging. J Med Ultrason 49(1):107\u20138","journal-title":"J Med Ultrason"},{"key":"1068_CR11","doi-asserted-by":"publisher","DOI":"10.3390\/diagnostics14060617","author":"E Dammann","year":"2024","unstructured":"Dammann E, Steinmeister L, Groth M, Herden U, Fischer L, Brinkert F et al (2024) Hepatic artery delineation on ultrasound volumes comparing B-flow and color doppler for postoperative monitoring of pediatric liver transplants. Diagnostics. https:\/\/doi.org\/10.3390\/diagnostics14060617","journal-title":"Diagnostics"},{"issue":"1","key":"1068_CR12","doi-asserted-by":"publisher","first-page":"53","DOI":"10.2214\/ajr.146.1.53","volume":"146","author":"M Lafortune","year":"1986","unstructured":"Lafortune M, Constantin A, Breton G, Vallee C (1986) Sonography of the hypertrophied column of Bertin. AJR Am J Roentgenol 146(1):53\u201356","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"1068_CR13","doi-asserted-by":"publisher","first-page":"27","DOI":"10.7863\/jum.2000.19.1.27","volume":"19","author":"S Strauss","year":"2000","unstructured":"Strauss S, Dushnitsky T, Peer A, Manor H, Libson E, Lebensart PD (2000) Sonographic features of horseshoe kidney: review of 34 patients. J Ultrasound Med 19(1):27\u201331","journal-title":"J Ultrasound Med"},{"issue":"1","key":"1068_CR14","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1007\/s00117-023-01249-x","volume":"64","author":"D Franke","year":"2024","unstructured":"Franke D, Renz DM, Mentzel HJ (2024) Imaging after kidney transplantation in childhood and adolescence. Radiologie (Heidelb) 64(1):45\u201353","journal-title":"Radiologie (Heidelb)"},{"key":"1068_CR15","doi-asserted-by":"crossref","unstructured":"Dammann E, Groth M, Schild RS, Lemke A, Oh J, Adam G, et al (2021) B-flow sonography vs. color doppler sonography for the assessment of vascularity in pediatric kidney transplantation. Rofo 193(1):49\u201360.","DOI":"10.1055\/a-1167-8317"},{"issue":"10","key":"1068_CR16","doi-asserted-by":"publisher","first-page":"2604","DOI":"10.1007\/s00261-018-1585-1","volume":"43","author":"TA Morgan","year":"2018","unstructured":"Morgan TA, Jha P, Poder L, Weinstein S (2018) Advanced ultrasound applications in the assessment of renal transplants: contrast-enhanced ultrasound, elastography, and B-flow. Abdom Radiol (NY) 43(10):2604\u20132614","journal-title":"Abdom Radiol (NY)"},{"issue":"2","key":"1068_CR17","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1002\/jcu.20892","volume":"40","author":"M Tola","year":"2012","unstructured":"Tola M, Yurdakul M, Ozbulbul NI (2012) B-flow imaging for the measurement of residual lumen diameter of renal artery stenosis. J Clin Ultrasound 40(2):85\u201390","journal-title":"J Clin Ultrasound"},{"key":"1068_CR18","doi-asserted-by":"crossref","unstructured":"Boccatonda A, Venerato S, D'Ardes D, Cocco G, Schiavone C, Vicari S (2023) Contrast-enhanced ultrasound follow-up for acute pyelonephritis patients. Healthcare (Basel) 11(21)","DOI":"10.3390\/healthcare11212899"},{"issue":"3","key":"1068_CR19","doi-asserted-by":"publisher","first-page":"98","DOI":"10.5527\/wjn.v13.i3.98300","volume":"13","author":"A Boccatonda","year":"2024","unstructured":"Boccatonda A, Stupia R, Serra C (2024) Ultrasound, contrast-enhanced ultrasound and pyelonephritis: a narrative review. World J Nephrol 13(3):98\u2013300","journal-title":"World J Nephrol"},{"key":"1068_CR20","doi-asserted-by":"publisher","DOI":"10.3390\/diagnostics14090930","author":"AG Hofmann","year":"2024","unstructured":"Hofmann AG, Mlekusch I, Wickenhauser G, Walter C, Taher F, Assadian A (2024) Individualizing surveillance after endovascular aortic repair using a modular imaging algorithm. Diagnostics. https:\/\/doi.org\/10.3390\/diagnostics14090930","journal-title":"Diagnostics"},{"issue":"3","key":"1068_CR21","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1002\/jum.16374","volume":"43","author":"A Hofmann","year":"2024","unstructured":"Hofmann A, Mlekusch I, Wickenhauser G, Walter C, Falkensammer J, Assadian A et al (2024) Ultrasound coded-excitation imaging for endoleak detection after complex endovascular aortic repair. J Ultrasound Med 43(3):429\u2013437","journal-title":"J Ultrasound Med"},{"key":"1068_CR22","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12113775","author":"AG Hofmann","year":"2023","unstructured":"Hofmann AG, Klosz FR, Mlekusch I, Wickenhauser G, Walter C, Assadian A et al (2023) Endoleak detection after endovascular aortic repair via coded-excitation ultrasound-a feasibility study. J Clin Med. https:\/\/doi.org\/10.3390\/jcm12113775","journal-title":"J Clin Med"},{"issue":"2","key":"1068_CR23","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1002\/jum.15729","volume":"41","author":"MU Aziz","year":"2022","unstructured":"Aziz MU, Robbin ML (2022) Improved detection of gallbladder perforation using ultrasound small vessel slow flow \u201cperfusion\u201d imaging. J Ultrasound Med 41(2):511\u2013518","journal-title":"J Ultrasound Med"},{"issue":"1","key":"1068_CR24","doi-asserted-by":"publisher","DOI":"10.1186\/s13244-021-01049-8","volume":"12","author":"G Cocco","year":"2021","unstructured":"Cocco G, Delli Pizzi A, Basilico R, Fabiani S, Taraschi AL, Pascucci L et al (2021) Imaging of gallbladder metastasis. Insights Imaging 12(1):100","journal-title":"Insights Imaging"},{"key":"1068_CR25","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-024-11156-x","author":"UW Lok","year":"2024","unstructured":"Lok UW, Tang S, Gong P, Smyrk T, Huang C, DeRuiter RM et al (2024) Quantitative assessment of ultrasound microvessel imaging in Crohn\u2019s disease: correlation with pathological inflammation. Eur Radiol. https:\/\/doi.org\/10.1007\/s00330-024-11156-x","journal-title":"Eur Radiol"},{"key":"1068_CR26","doi-asserted-by":"publisher","first-page":"5336","DOI":"10.12659\/MSM.914903","volume":"25","author":"DM Zu","year":"2019","unstructured":"Zu DM, Feng LL, Zhang L, Ma SL, Zhu YC (2019) Evaluation of mesenteric lymph nodes in a pediatric population with mesenteric lymphadenitis using superb microvascular imaging. Med Sci Monit 25:5336\u20135342","journal-title":"Med Sci Monit"},{"issue":"3","key":"1068_CR27","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1177\/1742271X18768841","volume":"26","author":"MK Dighe","year":"2018","unstructured":"Dighe MK, Moshiri M, Jolley J, Thiel J, Hippe D (2018) B-flow imaging of the placenta: a feasibility study. Ultrasound 26(3):160\u2013167","journal-title":"Ultrasound"},{"issue":"9","key":"1068_CR28","doi-asserted-by":"publisher","first-page":"1023","DOI":"10.1007\/s11547-023-01679-6","volume":"128","author":"R Cannella","year":"2023","unstructured":"Cannella R, Pilato G, Mazzola M, Bartolotta TV (2023) New microvascular ultrasound techniques: abdominal applications. Radiol Med 128(9):1023\u20131034","journal-title":"Radiol Med"}],"container-title":["Journal of Ultrasound"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s40477-025-01068-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s40477-025-01068-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s40477-025-01068-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,3]],"date-time":"2025-12-03T13:35:36Z","timestamp":1764768936000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s40477-025-01068-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,21]]},"references-count":28,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["1068"],"URL":"https:\/\/doi.org\/10.1007\/s40477-025-01068-x","relation":{},"ISSN":["1876-7931"],"issn-type":[{"value":"1876-7931","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,21]]},"assertion":[{"value":"24 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 August 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 August 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Carla Serra invited speeches at symposia for Bracco, ESAOTE, GE, Samsung, Philips. Other authors declare no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Consent to publish was obtained from all participants.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}}]}}