{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T18:27:31Z","timestamp":1791829651073,"version":"4.3.4"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T00:00:00Z","timestamp":1770681600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T00:00:00Z","timestamp":1770681600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100004332","name":"Seoul National University Hospital","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100004332","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Ultrasound"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Abdominal ultrasound (US) is widely used but often limited by restricted field of view. This study aimed to evaluate hepatic and splenic visualization using wide-view US with a 140\u00b0 scan angle compared with the routine-view technique in patients undergoing abdominal US.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>In this retrospective study, 258 patients who underwent scheduled abdominal US were included. Each patient received two scans, routine view (70\u00b0) and wide view (140\u00b0), performed by two experienced radiologists. Two readers independently assigned LI-RADS visualization scores (VIS-A, no or minimal limitations; VIS-B, moderate limitations; and VIS-C, severe limitations) and assessed whether the left lateral segment tip, segment VI tip, and right diaphragm were clearly visualized. Spleen length was measured on both US scans and, when available, on CT or MR images obtained within one year. Proportions were compared using the McNemar test, and agreement of spleen size between US and CT\/MR was assessed using the concordance correlation coefficient.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Wide-view US yielded a higher proportion of visualization score VIS-A than routine-view imaging for both readers (81.0\u201386.8% vs. 67.4\u201371.7%;\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&lt;\u20090.001). Coverage of the left lateral segment tip (96.9\u201398.4% vs 67.8\u201377.5%) and segment VI tip (89.5\u201397.3% vs 75.6\u201384.1%) was also higher on wide view (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&lt;\u2009.001). The right diaphragm was more clearly visualized on wide view (89.1\u201394.6% vs 59.7\u201369.8%;\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&lt;\u2009.001). Agreement of spleen size with CT\/MR was higher for wide-view than routine-view imaging (0.831 vs 0.772).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Wide-view US significantly improved hepatic visualization and spleen measurement accuracy, enabling more comprehensive evaluation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s40477-026-01117-z","type":"journal-article","created":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T14:35:24Z","timestamp":1770734124000},"page":"181-187","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Clinical utility of 140-degree scan angle wide-view ultrasound for comprehensive liver and spleen imaging"],"prefix":"10.1007","volume":"29","author":[{"given":"Seung-seob","family":"Kim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jong Keon","family":"Jang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8983-851X","authenticated-orcid":false,"given":"Dong Ho","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,2,10]]},"reference":[{"key":"1117_CR1","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1007\/BF01438313","volume":"123","author":"B Yang","year":"1997","unstructured":"Yang B, Zhang B, Xu Y, Wang W, Shen Y, Zhang A et al (1997) Prospective study of early detection for primary liver cancer. J Cancer Res Clin Oncol 123:357\u2013360","journal-title":"J Cancer Res Clin Oncol"},{"key":"1117_CR2","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1007\/s00432-004-0552-0","volume":"130","author":"BH Zhang","year":"2004","unstructured":"Zhang BH, Yang BH, Tang ZY (2004) Randomized controlled trial of screening for hepatocellular carcinoma. J Cancer Res Clin Oncol 130:417\u2013422","journal-title":"J Cancer Res Clin Oncol"},{"key":"1117_CR3","doi-asserted-by":"publisher","first-page":"697","DOI":"10.7326\/M14-2509","volume":"162","author":"R Chou","year":"2015","unstructured":"Chou R, Cuevas C, Fu R, Devine B, Wasson N, Ginsburg A et al (2015) Imaging techniques for the diagnosis of hepatocellular carcinoma: a systematic review and meta-analysis. Ann Intern Med 162:697\u2013711","journal-title":"Ann Intern Med"},{"key":"1117_CR4","doi-asserted-by":"publisher","first-page":"1706","DOI":"10.1053\/j.gastro.2018.01.064","volume":"154","author":"K Tzartzeva","year":"2018","unstructured":"Tzartzeva K, Obi J, Rich NE, Parikh ND, Marrero JA, Yopp A et al (2018) Surveillance imaging and alpha fetoprotein for early detection of hepatocellular carcinoma in patients with cirrhosis: a meta-analysis. Gastroenterology 154:1706\u201318.e1","journal-title":"Gastroenterology"},{"key":"1117_CR5","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0274747","volume":"17","author":"J Lee","year":"2022","unstructured":"Lee J, Park SB, Byun S, Kim HI (2022) Impact of ultrasonographic blind spots for early-stage hepatocellular carcinoma during surveillance. PLoS ONE 17:e0274747","journal-title":"PLoS ONE"},{"key":"1117_CR6","doi-asserted-by":"publisher","first-page":"2345","DOI":"10.1002\/jum.16570","volume":"43","author":"J Gao","year":"2024","unstructured":"Gao J, Flick A, Allen A, Krasnoff M, Kinder D, Nguyen T (2024) Variability in liver size measurements using different view angles in ultrasound imaging. J Ultrasound Med 43:2345\u20132355","journal-title":"J Ultrasound Med"},{"key":"1117_CR7","doi-asserted-by":"publisher","first-page":"1945","DOI":"10.1002\/jum.16738","volume":"44","author":"H Ishida","year":"2025","unstructured":"Ishida H, Naganuma H (2025) Letter to the Editor on \u201cVariability in Liver Size Measurements Using Different View Angles in Ultrasound Imaging.\u201d J Ultrasound Med 44:1945\u20131947","journal-title":"J Ultrasound Med"},{"key":"1117_CR8","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.222106","volume":"307","author":"MK Park","year":"2023","unstructured":"Park MK, Lee DH, Hur BY, Lee HC, Lee YB, Yu SJ et al (2023) Effectiveness of US surveillance of hepatocellular carcinoma in chronic hepatitis B: US LI-RADS visualization score. Radiology 307:e222106","journal-title":"Radiology"},{"key":"1117_CR9","doi-asserted-by":"publisher","first-page":"690","DOI":"10.1148\/rg.2019180158","volume":"39","author":"SK Rodgers","year":"2019","unstructured":"Rodgers SK, Fetzer DT, Gabriel H, Seow JH, Choi HH, Maturen KE et al (2019) Role of US LI-RADS in the LI-RADS algorithm. Radiographics 39:690\u2013708","journal-title":"Radiographics"},{"key":"1117_CR10","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1148\/radiol.2019190035","volume":"292","author":"JH Son","year":"2019","unstructured":"Son JH, Choi SH, Kim SY, Jang HY, Byun JH, Won HJ et al (2019) Validation of US liver imaging reporting and data system version 2017 in patients at high risk for hepatocellular carcinoma. Radiology 292:390\u2013397","journal-title":"Radiology"},{"key":"1117_CR11","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1016\/j.jhep.2012.12.028","volume":"59","author":"A Berzigotti","year":"2013","unstructured":"Berzigotti A, Castera L (2013) Update on ultrasound imaging of liver fibrosis. J Hepatol 59:180\u2013182","journal-title":"J Hepatol"},{"key":"1117_CR12","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1002\/(SICI)1097-0096(199902)27:2<71::AID-JCU4>3.0.CO;2-U","volume":"27","author":"WK Loftus","year":"1999","unstructured":"Loftus WK, Chow LT, Metreweli C (1999) Sonographic measurement of splenic length: correlation with measurement at autopsy. J Clin Ultrasound 27:71\u201374","journal-title":"J Clin Ultrasound"},{"key":"1117_CR13","doi-asserted-by":"publisher","first-page":"861","DOI":"10.1016\/j.ultrasmedbio.2004.05.012","volume":"30","author":"PS Li","year":"2004","unstructured":"Li PS, Ying M, Chan KH, Chan PW, Chu KL (2004) The reproducibility and short-term and long-term repeatability of sonographic measurement of splenic length. Ultrasound Med Biol 30:861\u2013866","journal-title":"Ultrasound Med Biol"}],"container-title":["Journal of Ultrasound"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s40477-026-01117-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s40477-026-01117-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s40477-026-01117-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T08:06:02Z","timestamp":1773821162000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s40477-026-01117-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,10]]},"references-count":13,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,3]]}},"alternative-id":["1117"],"URL":"https:\/\/doi.org\/10.1007\/s40477-026-01117-z","relation":{},"ISSN":["1876-7931"],"issn-type":[{"value":"1876-7931","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,10]]},"assertion":[{"value":"17 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 January 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 February 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All authors declare that they have no conflicts of interest related to this study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study was approved by institutional review boards (IRB) of Seoul national university hospital and Severance hospital (Approval No. H-2305\u2013082-1431) and conducted in accordance to the ethical guidelines of the World Medical Association Declaration of Helsinki. The written informed consent was waived by IRB due to retrospective nature of the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"All authors have provided their consent for publication of this study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to publish"}}]}}