{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T18:54:57Z","timestamp":1792176897423,"version":"4.4.0"},"reference-count":28,"publisher":"Oxford University Press (OUP)","issue":"7","license":[{"start":{"date-parts":[[2023,9,14]],"date-time":"2023-09-14T00:00:00Z","timestamp":1694649600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,9,14]],"date-time":"2023-09-14T00:00:00Z","timestamp":1694649600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Nephrol"],"DOI":"10.1007\/s40620-023-01741-6","type":"journal-article","created":{"date-parts":[[2023,9,14]],"date-time":"2023-09-14T10:08:52Z","timestamp":1694686132000},"page":"2001-2011","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Development and validation of AI-based triage support algorithms for prevention of intradialytic hypotension"],"prefix":"10.1093","volume":"36","author":[{"given":"Federica","family":"Gervasoni","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Bellocchio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaroslav","family":"Rosenberger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Otto","family":"Arkossy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jasmine","family":"Ion Titapiccolo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vratislava","family":"Kovarova","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Larkin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Milind","family":"Nikam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefano","family":"Stuard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giovanni Luigi","family":"Tripepi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Len A.","family":"Usvyat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anke","family":"Winter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luca","family":"Neri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carmine","family":"Zoccali","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2023,9,14]]},"reference":[{"issue":"2","key":"1741_CR1","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1111\/hdi.12138","volume":"18","author":"JJ Sands","year":"2014","unstructured":"Sands JJ et al (2014) Intradialytic hypotension: frequency, sources of variation and correlation with clinical outcome. Hemodial Int 18(2):415\u2013422. https:\/\/doi.org\/10.1111\/hdi.12138","journal-title":"Hemodial Int"},{"issue":"6","key":"1741_CR2","doi-asserted-by":"publisher","first-page":"497","DOI":"10.1159\/000500877","volume":"49","author":"J Kuipers","year":"2019","unstructured":"Kuipers J et al (2019) The prevalence of intradialytic hypotension in patients on conventional hemodialysis: a systematic review with meta-analysis. Am J Nephrol 49(6):497\u2013506. https:\/\/doi.org\/10.1159\/000500877","journal-title":"Am J Nephrol"},{"issue":"3","key":"1741_CR3","doi-asserted-by":"publisher","first-page":"724","DOI":"10.1681\/ASN.2014020222","volume":"26","author":"JE Flythe","year":"2015","unstructured":"Flythe JE, Xue H, Lynch KE et al (2015) Association of mortality risk with various definitions of intradialytic hypotension. J Am Soc Nephrol 26(3):724\u2013734. https:\/\/doi.org\/10.1681\/ASN.2014020222","journal-title":"J Am Soc Nephrol"},{"key":"1741_CR4","doi-asserted-by":"publisher","DOI":"10.1186\/s13054-014-0624-8","author":"JA Silversides","year":"2014","unstructured":"Silversides JA et al (2014) Fluid balance, intradialytic hypotension, and outcomes in critically ill patients undergoing renal replacement therapy: a cohort study. Crit Care. https:\/\/doi.org\/10.1186\/s13054-014-0624-8","journal-title":"Crit Care"},{"issue":"1\u20132","key":"1741_CR5","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1159\/000503776","volume":"49","author":"B Sars","year":"2020","unstructured":"Sars B, Van Der Sande FM, Kooman JP (2020) Intradialytic hypotension: mechanisms and outcome. Blood Purif 49(1\u20132):158\u2013167. https:\/\/doi.org\/10.1159\/000503776","journal-title":"Blood Purif"},{"issue":"6","key":"1741_CR6","doi-asserted-by":"publisher","first-page":"501","DOI":"10.1111\/sdi.12628","volume":"30","author":"JW Larkin","year":"2017","unstructured":"Larkin JW, Reviriego-Mendoza MM, Usvyat LA et al (2017) To cool, or too cool: Is reducing dialysate temperature the optimal approach to preventing intradialytic hypotension? Semin Dial 30(6):501\u2013508. https:\/\/doi.org\/10.1111\/sdi.12628","journal-title":"Semin Dial"},{"issue":"2","key":"1741_CR7","doi-asserted-by":"publisher","first-page":"800","DOI":"10.1046\/j.1523-1755.2000.00229.x","volume":"58","author":"C Ronco","year":"2000","unstructured":"Ronco C, Brendolan A, Milan M et al (2000) Impact of biofeedback-induced cardiovascular stability on hemodialysis tolerance and efficiency. Kidney Int 58(2):800\u2013808. https:\/\/doi.org\/10.1046\/j.1523-1755.2000.00229.x","journal-title":"Kidney Int"},{"issue":"8","key":"1741_CR8","doi-asserted-by":"publisher","first-page":"1526","DOI":"10.1681\/ASN.2010101119","volume":"22","author":"TI Chang","year":"2011","unstructured":"Chang TI et al (2011) Intradialytic hypotension and vascular access thrombosis. J Am Soc Nephrol 22(8):1526\u20131533. https:\/\/doi.org\/10.1681\/ASN.2010101119","journal-title":"J Am Soc Nephrol"},{"issue":"3","key":"1741_CR9","doi-asserted-by":"publisher","first-page":"1212","DOI":"10.1111\/j.1523-1755.2004.00812.x","volume":"66","author":"T Shoji","year":"2004","unstructured":"Shoji T et al (2004) Hemodialysis-associated hypotension as an independent risk factor for two-year mortality in hemodialysis patients. Kidney Int 66(3):1212\u20131220. https:\/\/doi.org\/10.1111\/j.1523-1755.2004.00812.x","journal-title":"Kidney Int"},{"issue":"6","key":"1741_CR10","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1111\/SDI.12627","volume":"30","author":"JA Chou","year":"2017","unstructured":"Chou JA, Kalantar-Zadeh K, Mathew AT (2017) A brief review of intradialytic hypotension with a focus on survival. Semin Dial 30(6):473\u2013480. https:\/\/doi.org\/10.1111\/SDI.12627","journal-title":"Semin Dial"},{"issue":"5","key":"1741_CR11","doi-asserted-by":"publisher","first-page":"1420","DOI":"10.1093\/NDT\/GFL799","volume":"22","author":"E Mancini","year":"2007","unstructured":"Mancini E et al (2007) Prevention of dialysis hypotension episodes using fuzzy logic control system. Nephrol Dial Transplant 22(5):1420\u20131427. https:\/\/doi.org\/10.1093\/NDT\/GFL799","journal-title":"Nephrol Dial Transplant"},{"key":"1741_CR12","doi-asserted-by":"publisher","DOI":"10.2215\/cjn.09280620","author":"H Lee","year":"2021","unstructured":"Lee H et al (2021) Deep learning model for real-time prediction of intradialytic hypotension. Clin J Am Soc Nephrol. https:\/\/doi.org\/10.2215\/cjn.09280620","journal-title":"Clin J Am Soc Nephrol"},{"key":"1741_CR13","doi-asserted-by":"publisher","DOI":"10.3389\/fmed.2022.878858","author":"HW Kim","year":"2022","unstructured":"Kim HW et al (2022) Deep learning model for predicting intradialytic hypotension without privacy infringement: a retrospective two-center study. Front Med J. https:\/\/doi.org\/10.3389\/fmed.2022.878858","journal-title":"Front Med J"},{"issue":"01","key":"1741_CR14","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1055\/s-0038-1633841","volume":"43","author":"H Steil","year":"2004","unstructured":"Steil H et al (2004) EuCliD\u00ae\u2014a medical registry. Methods Inf Med 43(01):83\u201388. https:\/\/doi.org\/10.1055\/s-0038-1633841","journal-title":"Methods Inf Med"},{"key":"1741_CR15","unstructured":"Marcelli D (2001) EuCliD (European Clinical Database): a database comparing different realities. J Nephrol 14(4 SUPPL):S94\u2013S100. Available: http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/11798154"},{"issue":"11","key":"1741_CR16","doi-asserted-by":"publisher","first-page":"1049","DOI":"10.1177\/039139880202501103","volume":"25","author":"JI MerelloGodino","year":"2002","unstructured":"MerelloGodino JI, Rentero R, Orlandini G et al (2002) Results from EuCliD\u00ae (European Clinical Dialysis Database): impact of shifting treatment modality. Int J Artif Organs 25(11):1049\u20131060. https:\/\/doi.org\/10.1177\/039139880202501103","journal-title":"Int J Artif Organs"},{"issue":"3","key":"1741_CR17","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1046\/j.1525-139X.2002.00002.x","volume":"15","author":"RA Sherman","year":"2002","unstructured":"Sherman RA (2002) Intradialytic hypotension: an overview of recent, unresolved and overlooked issues. Semin Dial 15(3):141\u2013143. https:\/\/doi.org\/10.1046\/j.1525-139X.2002.00002.x","journal-title":"Semin Dial"},{"key":"1741_CR18","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-019-39295-y","author":"S Park","year":"2019","unstructured":"Park S et al (2019) Predicting intradialytic hypotension using heart rate variability. Sci Rep. https:\/\/doi.org\/10.1038\/s41598-019-39295-y","journal-title":"Sci Rep"},{"issue":"6","key":"1741_CR19","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1111\/sdi.12626","volume":"30","author":"MM Assimon","year":"2017","unstructured":"Assimon MM, Flythe JE (2017) Definitions of intradialytic hypotension. Semin Dial 30(6):464\u2013472. https:\/\/doi.org\/10.1111\/sdi.12626","journal-title":"Semin Dial"},{"issue":"Suppl 2","key":"1741_CR20","doi-asserted-by":"publisher","first-page":"785","DOI":"10.1093\/NDT\/GFM019","volume":"22","author":"J Kooman","year":"2007","unstructured":"Kooman J et al (2007) EBPG guideline on haemodynamic instability. Nephrol Dial Transplant 22(Suppl 2):785\u2013794. https:\/\/doi.org\/10.1093\/NDT\/GFM019","journal-title":"Nephrol Dial Transplant"},{"issue":"1","key":"1741_CR21","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12882-016-0231-9","volume":"17","author":"J Kuipers","year":"2016","unstructured":"Kuipers J et al (2016) Prevalence of intradialytic hypotension, clinical symptoms and nursing interventions\u2014a three-months, prospective study of 3818 haemodialysis sessions Dialysis and Transplantation. BMC Nephrol 17(1):1\u201311. https:\/\/doi.org\/10.1186\/s12882-016-0231-9","journal-title":"BMC Nephrol"},{"key":"1741_CR22","doi-asserted-by":"publisher","unstructured":"(2005) K\/DOQI clinical practice guidelines for cardiovascular disease in dialysis patients. Am J Kidney Dis 45(Suppl 3):16\u2013153. https:\/\/doi.org\/10.1053\/J.AJKD.2005.01.019","DOI":"10.1053\/J.AJKD.2005.01.019"},{"issue":"1","key":"1741_CR23","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1159\/000493479","volume":"5","author":"C Barbieri","year":"2019","unstructured":"Barbieri C et al (2019) Development of an artificial intelligence model to guide the management of blood pressure, fluid volume, and dialysis dose in end-stage kidney disease patients: proof of concept and first clinical assessment. Kidney Dis 5(1):28\u201333. https:\/\/doi.org\/10.1159\/000493479","journal-title":"Kidney Dis"},{"issue":"10","key":"1741_CR24","doi-asserted-by":"publisher","first-page":"888","DOI":"10.1016\/J.JFMA.2018.05.023","volume":"117","author":"CJ Lin","year":"2018","unstructured":"Lin CJ et al (2018) Intelligent system to predict intradialytic hypotension in chronic hemodialysis. J Formos Med Assoc 117(10):888\u2013893. https:\/\/doi.org\/10.1016\/J.JFMA.2018.05.023","journal-title":"J Formos Med Assoc"},{"issue":"1","key":"1741_CR25","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/S12882-019-1366-2\/TABLES\/2","volume":"20","author":"J Kuipers","year":"2019","unstructured":"Kuipers J et al (2019) Association between quality of life and various aspects of intradialytic hypotension including patient-reported intradialytic symptom score. BMC Nephrol 20(1):1\u20138. https:\/\/doi.org\/10.1186\/S12882-019-1366-2\/TABLES\/2","journal-title":"BMC Nephrol"},{"issue":"6","key":"1741_CR26","doi-asserted-by":"publisher","first-page":"805","DOI":"10.2215\/CJN.06810619","volume":"15","author":"FR McCausland","year":"2020","unstructured":"McCausland FR et al (2020) Intradialytic hypotension and cardiac arrhythmias in patients undergoing maintenance hemodialysis: results from the monitoring in dialysis study. Clin J Am Soc Nephrol 15(6):805\u2013812. https:\/\/doi.org\/10.2215\/CJN.06810619","journal-title":"Clin J Am Soc Nephrol"},{"issue":"1","key":"1741_CR27","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/S12882-019-1662-X","volume":"20","author":"R Matsuura","year":"2019","unstructured":"Matsuura R et al (2019) Intradialytic hypotension is an important risk factor for critical limb ischemia in patients on hemodialysis. BMC Nephrol 20(1):1\u20138. https:\/\/doi.org\/10.1186\/S12882-019-1662-X","journal-title":"BMC Nephrol"},{"issue":"4","key":"1741_CR28","doi-asserted-by":"publisher","first-page":"1156","DOI":"10.1093\/CKJ\/SFAA070","volume":"14","author":"S Cede\u00f1o","year":"2021","unstructured":"Cede\u00f1o S et al (2021) Intradialytic hypotension and relationship with cognitive function and brain morphometry. Clin Kidney J 14(4):1156\u20131164. https:\/\/doi.org\/10.1093\/CKJ\/SFAA070","journal-title":"Clin Kidney J"}],"container-title":["Journal of Nephrology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s40620-023-01741-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s40620-023-01741-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s40620-023-01741-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T15:53:03Z","timestamp":1777564383000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/joneph\/article\/36\/7\/2001\/8304334"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,14]]},"references-count":28,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2023,9]]}},"alternative-id":["1741"],"URL":"https:\/\/doi.org\/10.1007\/s40620-023-01741-6","relation":{},"ISSN":["1724-6059"],"issn-type":[{"value":"1724-6059","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,14]]},"assertion":[{"value":"15 February 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 July 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 September 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"FG, FB, JR, OA, JIT, VK, JL, MN, SS, LU, AW, LN are employees of Fresenius Medical Care. LU, JL, MN have share options\/ownership in Fresenius Medical Care. LU, JL, MN  hold\u00a0patents in the field of dialysis. JL has received honorarium from The Lancet and is a guest editor on the Editorial Board of Frontiers in Physiology. LU is an advisory board member for Privacy Analytics Inc. The remaining author declares no commercial or financial conflict of interest. GLT, CZ are consultants of Fresenius Medical Care.\u00a0","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The included patients granted the permission to use their pseudo-anonymized data for secondary data analysis. The current research was conducted in adherence with the Declaration of Helsinki. The study has been approved by the Ethics Committee of the FMC-dialysis services, s.r.o.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"All patients consented their data be processed for secondary data analysis. A specific informed consent is not required for this type of study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}