{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T00:56:06Z","timestamp":1793235366703,"version":"4.5.0"},"reference-count":66,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2020,3,13]],"date-time":"2020-03-13T00:00:00Z","timestamp":1584057600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,3,13]],"date-time":"2020-03-13T00:00:00Z","timestamp":1584057600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Spine Deform"],"published-print":{"date-parts":[[2020,8]]},"DOI":"10.1007\/s43390-020-00094-5","type":"journal-article","created":{"date-parts":[[2020,3,13]],"date-time":"2020-03-13T15:02:51Z","timestamp":1584111771000},"page":"809-817","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Malpositioned pedicle screw in spine deformity surgery endangering the aorta: report of two cases, review of literature, and proposed management algorithm"],"prefix":"10.1007","volume":"8","author":[{"given":"Matej","family":"Vali\u010d","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"\u017di\u017eek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matja\u017e","family":"\u0160pan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ren\u00e9","family":"Mihali\u010d","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Janez","family":"Mohar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,3,13]]},"reference":[{"key":"94_CR1","doi-asserted-by":"crossref","first-page":"1399","DOI":"10.1097\/00007632-199506020-00012","volume":"20","author":"SI Suk","year":"1995","unstructured":"Suk SI, Lee CK, Kim WJ et al (1995) Segmental pedicle screw fixation in the treatment of idiopathic thoracic scoliosis. Spine 20:1399\u20131405","journal-title":"Spine"},{"key":"94_CR2","doi-asserted-by":"crossref","first-page":"1051","DOI":"10.1097\/BRS.0b013e31816f2865","volume":"33","author":"LG Lenke","year":"2008","unstructured":"Lenke LG, Kuklo TR, Ondra S et al (2008) Rationale behind the current state-of-the-art treatment of scoliosis (in the pedicle screw era). Spine 33:1051\u20131054","journal-title":"Spine"},{"key":"94_CR3","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1097\/01.BRS.0000105525.06564.56","volume":"29","author":"DW Polly Jr","year":"2004","unstructured":"Polly DW Jr, Potter BK, Kuklo T et al (2004) Volumetric spinal canal intrusion: a comparison between thoracic pedicle screws and thoracic hooks. Spine 29:63\u201369","journal-title":"Spine"},{"key":"94_CR4","doi-asserted-by":"crossref","first-page":"1461","DOI":"10.2106\/00004623-200308000-00006","volume":"85-A","author":"DJ Sucato","year":"2003","unstructured":"Sucato DJ, Duchene C (2003) The position of the aorta relative to the spine: a comparison of patients with and without idiopathic scoliosis. J Bone Joint Surg Am 85-A:1461\u20131469","journal-title":"J Bone Joint Surg Am"},{"key":"94_CR5","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1007\/s11517-012-0900-1","volume":"50","author":"S Lu","year":"2012","unstructured":"Lu S, Zhang YZ, Wang Z et al (2012) Accuracy and efficacy of thoracic pedicle screws in scoliosis with patient-specific drill template. Med Biol Eng Comput 50:751\u2013758","journal-title":"Med Biol Eng Comput"},{"key":"94_CR6","first-page":"1","volume":"31","author":"U Sevuk","year":"2016","unstructured":"Sevuk U, Mesut A, Kiraz I et al (2016) Delayed presentation of aortic injury by a thoracic pedicle screw. J Card Surg 31:1\u201311","journal-title":"J Card Surg"},{"key":"94_CR7","doi-asserted-by":"crossref","first-page":"893","DOI":"10.1016\/j.jvs.2003.10.056","volume":"39","author":"ME Minor","year":"2004","unstructured":"Minor ME, Morrissey NJ, Peress R et al (2004) Endovascular treatment of an iatrogenic thoracic aortic injury after spinal instrumentation: case report. J Vasc Surg 39:893\u2013896","journal-title":"J Vasc Surg"},{"key":"94_CR8","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1111\/jocs.12327","volume":"29","author":"ST Pillai","year":"2014","unstructured":"Pillai ST, Schoenhagen P, Subrahmanyan L et al (2014) Aortic dissection associated with penetration of a spinal pedicle screw: a case report and review of the literature. J Card Surg 29:377\u2013381","journal-title":"J Card Surg"},{"key":"94_CR9","doi-asserted-by":"crossref","first-page":"290","DOI":"10.3109\/02688697.2014.978840","volume":"29","author":"LA Tan","year":"2015","unstructured":"Tan LA, Ahuja SK, Deutsch H (2015) The \u2018\u2018screwed aorta\u2019\u2019 after spinal deformity surgery. Br J Neurosurg 29:290","journal-title":"Br J Neurosurg"},{"key":"94_CR10","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1016\/j.wneu.2019.04.173","volume":"128","author":"S Kayac\u0131","year":"2019","unstructured":"Kayac\u0131 S, Cakir T, Dolgun M et al (2019) Aortic injury by thoracic pedicle screw. When is aortic repair required? Literature review and three new cases. World Neurosurg 128:216\u2013224","journal-title":"World Neurosurg"},{"key":"94_CR11","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1097\/00005373-200101000-00029","volume":"50","author":"JB Choi","year":"2011","unstructured":"Choi JB, Han JO, Jeong JW (2011) False aneurysm of the thoracic aorta associated with an aorto-chest wall fistula after spinal instrumentation. J Trauma 50:140\u2013143","journal-title":"J Trauma"},{"key":"94_CR12","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1093\/ejcts\/ezt151","volume":"44","author":"O Fouquet","year":"2013","unstructured":"Fouquet O, Loubi\u00e8re H, Talha A et al (2013) A pedicle screw in the descending thoracic aorta: a surgical approach. Eur J Cardiothorac Surg 44:391\u2013392","journal-title":"Eur J Cardiothorac Surg"},{"key":"94_CR13","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1016\/j.otsr.2014.03.020","volume":"100","author":"S Pesenti","year":"2014","unstructured":"Pesenti S, Bartoli MA, Blondel B et al (2014) Endovascular aortic injury repair after thoracic pedicle screw placement. Orthop Traumatol Surg Res 100:569\u2013573","journal-title":"Orthop Traumatol Surg Res"},{"key":"94_CR14","doi-asserted-by":"crossref","first-page":"E1064","DOI":"10.1097\/BRS.0b013e3181ed29c1","volume":"35","author":"K Watanabe","year":"2010","unstructured":"Watanabe K, Yamazaki A, Hirano T et al (2010) Descending aortic injury by a thoracic pedicle screw during posterior reconstructive surgery: a case report. Spine 35:E1064\u2013E1068","journal-title":"Spine"},{"key":"94_CR15","doi-asserted-by":"crossref","first-page":"1782","DOI":"10.1016\/j.jvs.2011.02.051","volume":"55","author":"JM Mart\u00edn-Pedrosa","year":"2012","unstructured":"Mart\u00edn-Pedrosa JM, Guti\u00e9rrez V, Gonz\u00e1lez-Fajardo JA et al (2012) Endovascular treatment of thoracic aorta injury after spinal column surgery. J Vasc Surg 55:1782\u20131783","journal-title":"J Vasc Surg"},{"key":"94_CR16","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1097\/BTO.0000000000000240","volume":"32","author":"SO Ryabykh","year":"2017","unstructured":"Ryabykh SO, Pavlova OM, Savin DM et al (2017) Malpositioned pedicle screw compressed thoracic aorta of a patient with adolescent idiopathic scoliosis: case report and literature review. Tech Orthop 32:277\u2013282","journal-title":"Tech Orthop"},{"key":"94_CR17","first-page":"1132","volume":"6","author":"H Yammine","year":"2018","unstructured":"Yammine H, Ballast JK, Boyes C et al (2018) TEVAR for treatment of metallic pedicle screw penetrating the thoracic aorta. J Cardiol Clin Res 6:1132","journal-title":"J Cardiol Clin Res"},{"key":"94_CR18","first-page":"361","volume":"79","author":"KC Soultanis","year":"2013","unstructured":"Soultanis KC, Sakellariou VI, Starantzis KA et al (2013) Late diagnosis of perforation of the aorta by a pedicle screw. Acta Orthop Belg 79:361\u2013367","journal-title":"Acta Orthop Belg"},{"key":"94_CR19","first-page":"1","volume":"2015","author":"K Lagios","year":"2015","unstructured":"Lagios K, Karaolanis G, Perdikides T et al (2015) Thoracic aortic injury: embolization of the tenth intercostal artery and endovascular treatment in a young woman after posterior spinal instrumentation. Case Rep Vasc Med 2015:1\u20134","journal-title":"Case Rep Vasc Med"},{"issue":"4","key":"94_CR20","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1016\/j.jvsc.2015.09.001","volume":"1","author":"P Claiborne","year":"2015","unstructured":"Claiborne P, Mallios A, Taubman K et al (2015) Endovascular repair of thoracic aortic injury after spinal instrumentation. J Vasc Surg Cases 1(4):264\u2013267","journal-title":"J Vasc Surg Cases"},{"key":"94_CR21","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1007\/s00068-004-1422-9","volume":"30","author":"M Zdichavsky","year":"2004","unstructured":"Zdichavsky M, Blauth M, Knop C et al (2004) Accuracy of pedicle screw placement in thoracic spine fractures. Part I: inter- and intra-observer reliability of the scoring system. Eur J Trauma 30:234\u2013240","journal-title":"Eur J Trauma"},{"key":"94_CR22","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1007\/s00068-004-1423-8","volume":"30","author":"M Zdichavsky","year":"2004","unstructured":"Zdichavsky M, Blauth M, Knop C et al (2004) Accuracy of pedicle screw placement in thoracic spine fractures. Part II: a retrospective analysis of 278 pedicle screws using computed tomographic scans. Eur J Trauma 30:241\u2013247","journal-title":"Eur J Trauma"},{"key":"94_CR23","doi-asserted-by":"crossref","first-page":"1469","DOI":"10.1007\/s00586-009-1050-5","volume":"18","author":"M Beck","year":"2009","unstructured":"Beck M, Mittlmeier T, Gierer P et al (2009) Benefit and accuracy of intraoperative 3D-imaging after pedicle screw placement: a prospective study in stabilizing thoracolumbar fractures. Eur Spine J 18:1469\u20131477","journal-title":"Eur Spine J"},{"key":"94_CR24","doi-asserted-by":"crossref","first-page":"2679","DOI":"10.1097\/BRS.0b013e31815a7f13","volume":"32","author":"RA Lehman Jr","year":"2007","unstructured":"Lehman RA Jr, Lenke LG, Keeler KA et al (2007) Computed tomography evaluation of pedicle screws placed in the pediatric deformed spine over an 8-year period. Spine 32:2679\u20132684","journal-title":"Spine"},{"key":"94_CR25","doi-asserted-by":"crossref","first-page":"E465","DOI":"10.1097\/BRS.0b013e3181d1021a","volume":"35","author":"JM Hicks","year":"2010","unstructured":"Hicks JM, Singla A, Shen FH et al (2010) Complications of pedicle screw fixation in scoliosis surgery: a systematic review. Spine 35:E465\u2013E470","journal-title":"Spine"},{"key":"94_CR26","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1007\/s00586-009-1183-6","volume":"19","author":"AF Samdani","year":"2010","unstructured":"Samdani AF, Ranade A, Sciubba DM et al (2010) Accuracy of free-hand placement of thoracic pedicle screws in adolescent idiopathic scoliosis: how much of a difference does surgeon experience make? Eur Spine J 19:91\u201395","journal-title":"Eur Spine J"},{"key":"94_CR27","first-page":"96","volume":"90","author":"W Yingsakmongkol","year":"2007","unstructured":"Yingsakmongkol W, Hangsaphuk N, Lerdlam S (2007) The accuracy of pedicle screw placement in thoracic spine using the Funnel technique in idiopathic scoliosis. J Med Assoc Thail 90:96\u2013105","journal-title":"J Med Assoc Thail"},{"key":"94_CR28","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1097\/BRS.0000000000001738","volume":"42","author":"MK Kwan","year":"2017","unstructured":"Kwan MK, Chiu CK, Gani SM et al (2017) Accuracy and safety of pedicle screw placement in adolescent idiopathic scoliosis patients: a review of 2020 screws using computed tomography assessment. Spine 42:326\u2013335","journal-title":"Spine"},{"key":"94_CR29","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1097\/BSD.0b013e31825bfecd","volume":"27","author":"V Sarwahi","year":"2014","unstructured":"Sarwahi V, Suggs W, Wollowick AL et al (2014) Pedicle screws adjacent to the great vessels or viscera: a study of 2132 pedicle screws in pediatric spine deformity. J Spinal Disord Tech 27:64\u201369","journal-title":"J Spinal Disord Tech"},{"key":"94_CR30","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1007\/s00586-008-0639-4","volume":"17","author":"AY Sarlak","year":"2008","unstructured":"Sarlak AY, Bulu\u00e7 L, Sarisoy HT et al (2008) Placement of pedicle screws in thoracic idiopathic scoliosis: a magnetic resonance imaging analysis of screw placement relative to structures at risk. Eur Spine J 17:657\u2013662","journal-title":"Eur Spine J"},{"key":"94_CR31","first-page":"870","volume":"69","author":"JE Lopera","year":"2010","unstructured":"Lopera JE, Restrepo CS, Gonzales A et al (2010) Aortoiliac vascular injuries after misplacement of fixation screws. J Trauma 69:870\u2013875","journal-title":"J Trauma"},{"key":"94_CR32","doi-asserted-by":"crossref","first-page":"1477","DOI":"10.1016\/j.jvs.2010.10.064","volume":"55","author":"SA Loh","year":"2012","unstructured":"Loh SA, Maldonaldo TS, Rockman CB et al (2012) Endovascular solutions to arterial injury due to posterior spine surgery. J Vasc Surg 55:1477\u20131481","journal-title":"J Vasc Surg"},{"key":"94_CR33","doi-asserted-by":"crossref","first-page":"56","DOI":"10.3109\/13645706.2012.692332","volume":"22","author":"M Rabellino","year":"2013","unstructured":"Rabellino M, Garcia-Monaco R, Cesareo V et al (2013) Endovascular treatment of iatrogenic aortic injury after spinal surgery. Minim Invasive Ther Allied Technol 22:56\u201360","journal-title":"Minim Invasive Ther Allied Technol"},{"key":"94_CR34","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1097\/BRS.0000000000000221","volume":"39","author":"SL Parker","year":"2014","unstructured":"Parker SL, Amin AG, Santiago-Dieppa D et al (2014) Incidence and clinical significance of vascular encroachment resulting from freehand placement of pedicle screws in the thoracic and lumbar spine: analysis of 6816 consecutive screws. Spine 39:683\u2013687","journal-title":"Spine"},{"key":"94_CR35","doi-asserted-by":"crossref","first-page":"E753","DOI":"10.1097\/BRS.0b013e31815b657c","volume":"32","author":"R Kopp","year":"2007","unstructured":"Kopp R, Beisse R, Weidenhagen R et al (2007) Strategies for prevention and operative treatment of aortic lesions related to spinal interventions. Spine 32:E753\u2013E760","journal-title":"Spine"},{"key":"94_CR36","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1007\/BF03207763","volume":"18","author":"B Sevastik","year":"1996","unstructured":"Sevastik B, Xiong B, Hedlund R et al (1996) The position of the aorta in relation to the vertebra in patients with idiopathic thoracic scoliosis. Surg Radiol Anat 18:51\u201356","journal-title":"Surg Radiol Anat"},{"key":"94_CR37","doi-asserted-by":"crossref","first-page":"E886","DOI":"10.1097\/BRS.0b013e318202e4d1","volume":"36","author":"SK Tschoeke","year":"2011","unstructured":"Tschoeke SK, Gahr P, Krug L et al (2011) Late diagnosis of pedicle screw malplacement with perforation of the thoracic aorta after posterior stabilization in a patient with multiple myeloma: case report. Spine 36:E886\u2013E890","journal-title":"Spine"},{"key":"94_CR38","doi-asserted-by":"crossref","first-page":"1892","DOI":"10.1007\/s00586-009-1065-y","volume":"18","author":"AY Sarlak","year":"2009","unstructured":"Sarlak AY, Tosun B, Atmaca H et al (2009) Evaluation of thoracic pedicle screw placement in adolescent idiopathic scoliosis. Eur Spine J 18:1892\u20131897","journal-title":"Eur Spine J"},{"key":"94_CR39","doi-asserted-by":"crossref","first-page":"E1054","DOI":"10.1097\/BRS.0b013e3182600a7d","volume":"37","author":"H Jiang","year":"2012","unstructured":"Jiang H, Qiu X, Wang W et al (2012) The position of the aorta changes with altered body position in single right thoracic adolescent idiopathic scoliosis: a magnetic resonance imaging study. Spine 37:E1054\u2013E1061","journal-title":"Spine"},{"key":"94_CR40","doi-asserted-by":"crossref","first-page":"1481","DOI":"10.1007\/s00586-015-3823-3","volume":"24","author":"L Chen","year":"2015","unstructured":"Chen L, Xu L, Qiu Y et al (2015) The risks of aorta impingement from pedicle screw may increase due to aorta movement during posterior instrumentation in Lenke 5C curve: a computed tomography study. Eur Spine J 24:1481\u20131489","journal-title":"Eur Spine J"},{"key":"94_CR41","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1007\/s00586-010-1298-9","volume":"19","author":"K Takeshita","year":"2010","unstructured":"Takeshita K, Maruyama T, Ono T et al (2010) New parameters to represent the position of the aorta relative to the spine for pedicle screw placement. Eur Spine J 19:815\u2013820","journal-title":"Eur Spine J"},{"issue":"Suppl 2","key":"94_CR42","doi-asserted-by":"crossref","first-page":"S351","DOI":"10.1007\/s00586-008-0715-9","volume":"17","author":"B Wegener","year":"2008","unstructured":"Wegener B, Birkenmaier C, Fottner A et al (2008) Delayed perforation of the aorta by a thoracic pedicle screw. Eur Spine J 17(Suppl 2):S351\u2013S354","journal-title":"Eur Spine J"},{"key":"94_CR43","doi-asserted-by":"crossref","first-page":"1074","DOI":"10.1016\/j.jvs.2007.11.005","volume":"47","author":"SK Kakkos","year":"2008","unstructured":"Kakkos SK, Shepard AD (2008) Delayed presentation of aortic injury by pedicle screws: report of two cases and review of the literature. J Vasc Surg 47:1074\u20131082","journal-title":"J Vasc Surg"},{"key":"94_CR44","doi-asserted-by":"crossref","first-page":"2406","DOI":"10.1097\/01.brs.0000184587.25330.40","volume":"30","author":"FD Faro","year":"2005","unstructured":"Faro FD, Farnsworth CL, Shapiro GS et al (2005) Thoracic vertebral screw impingement on the aorta in an in vivo bovine model. Spine 30:2406\u20132413","journal-title":"Spine"},{"key":"94_CR45","unstructured":"Manning WJ, Black JH (2018) Overview of acute aortic dissection and other acute aortic syndromes [UpToDate website]. https:\/\/www.uptodate.com\/contents\/overview-of-acute-aortic-dissection-and-other-acute-aortic-syndromes?search=Overview%20of%20acute%20aortic%20dissection%20and%20other%20acute%20aortic%20syndromes&source=search_result&selectedTitle=1~150&usage_type=default&display_rank=1. Accessed 2 July 2019"},{"key":"94_CR46","doi-asserted-by":"crossref","first-page":"1040","DOI":"10.1007\/s00270-009-9782-5","volume":"33","author":"HT Hu","year":"2010","unstructured":"Hu HT, Shin JH, Hwang JY et al (2010) Thoracic aortic stent-graft placement for safe removal of a malpositioned pedicle screw. Cardiovasc Interv Radiol 33:1040\u20131043","journal-title":"Cardiovasc Interv Radiol"},{"key":"94_CR47","doi-asserted-by":"crossref","first-page":"550","DOI":"10.3171\/2011.7.SPINE10267","volume":"15","author":"MJ Clarke","year":"2011","unstructured":"Clarke MJ, Guzzo J, Wolinsky JP et al (2011) Combined endovascular and neurosurgical approach to the removal of an intraaortic pedicle screw. J Neurosurg Spine 15:550\u2013554","journal-title":"J Neurosurg Spine"},{"key":"94_CR48","first-page":"136","volume":"18","author":"J Sokolic","year":"1991","unstructured":"Sokolic J, Sosa T, Ugljen R et al (1991) Extrinsic erosion of the descending aorta by a vertebral fixator. Tex Heart Inst J 18:136\u2013139","journal-title":"Tex Heart Inst J"},{"key":"94_CR49","first-page":"132.e1","volume":"25","author":"J Jim","year":"2011","unstructured":"Jim J, Sanchez LA, Geraghty PJ (2011) Endovascular repair of an intraoperative thoracic aortic injury during all-posterior vertebral column resection surgery. Ann Vasc Surg 25:132.e1\u2013132.e6","journal-title":"Ann Vasc Surg"},{"key":"94_CR50","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1111\/jocs.12052","volume":"28","author":"A Carmignani","year":"2013","unstructured":"Carmignani A, Lentini S, Acri E et al (2013) Combined thoracic endovascular aortic repair and neurosurgical intervention for injury due to posterior spine surgery. J Card Surg 28:163\u2013167","journal-title":"J Card Surg"},{"key":"94_CR51","doi-asserted-by":"crossref","first-page":"1512","DOI":"10.1016\/j.athoracsur.2011.04.041","volume":"92","author":"C Bavare","year":"2011","unstructured":"Bavare C, Kim M, Blackmon S et al (2011) Delayed aortic rupture after aortic endograft placement in patient with spinal hardware. Ann Thorac Surg 92:1512\u20131514","journal-title":"Ann Thorac Surg"},{"key":"94_CR52","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1007\/s00264-006-0230-8","volume":"31","author":"V Kosmopoulos","year":"2007","unstructured":"Kosmopoulos V, Theumann N, Binaghi S et al (2007) Observer reliability in evaluating pedicle screw placement using computed tomography. Int Orthop 31:531\u2013536","journal-title":"Int Orthop"},{"key":"94_CR53","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1213\/ANE.0b013e318275341d","volume":"116","author":"MH Iyer","year":"2013","unstructured":"Iyer MH, Engoren M, Martin MW (2013) Echo rounds: transesophageal echocardiography: identification and management of a misplaced pedicle screw in the descending thoracic aorta after posterior spinal fusion. Anesth Analg 116:303\u2013306","journal-title":"Anesth Analg"},{"key":"94_CR54","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1016\/j.jfma.2013.09.014","volume":"114","author":"X Tong","year":"2015","unstructured":"Tong X, Gu P, Yu D et al (2015) An endovascular treatment of a thoracic aortic injury caused by a misplaced pedicle screw: case report and review of the literature. J Formos Med Assoc 114:464\u2013468","journal-title":"J Formos Med Assoc"},{"key":"94_CR55","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1053\/j.tvir.2018.06.003","volume":"21","author":"BD Bodell","year":"2018","unstructured":"Bodell BD, Taylor AC, Patel PJ (2018) Thoracic endovascular aortic repair: review of current devices and treatments options. Tech Vasc Interv Radiol 21:137\u2013145","journal-title":"Tech Vasc Interv Radiol"},{"key":"94_CR56","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1053\/j.tvir.2018.06.004","volume":"21","author":"R Al-Hakim","year":"2018","unstructured":"Al-Hakim R, Schenning R (2018) Advanced techniques in thoracic endovascular aortic repair: chimneys\/periscopes, fenestrated endografts, and branched devices. Tech Vasc Interv Radiol 21:146\u2013155","journal-title":"Tech Vasc Interv Radiol"},{"key":"94_CR57","doi-asserted-by":"crossref","first-page":"ii3","DOI":"10.1093\/bja\/aew222","volume":"117","author":"SWK Cheng","year":"2016","unstructured":"Cheng SWK (2016) Novel endovascular procedures and new developments in aortic surgery. Br J Anaesth 117:ii3\u2013ii12","journal-title":"Br J Anaesth"},{"key":"94_CR58","first-page":"125","volume":"3","author":"P Carrascosa","year":"2013","unstructured":"Carrascosa P, Capu\u00f1ay C, Deviggiano A et al (2013) Thoracic aorta cardiac-cycle related dynamic changes assessed with a 256-slice CT scanner. Cardiovasc Diagn Ther 3:125\u2013128","journal-title":"Cardiovasc Diagn Ther"},{"key":"94_CR59","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.jvs.2013.07.005","volume":"59","author":"J Parodi","year":"2014","unstructured":"Parodi J, Berguer R, Carrascosa P et al (2014) Sources of error in the measurement of aortic diameter in computed tomography scans. J Vasc Surg 59:74\u201379","journal-title":"J Vasc Surg"},{"key":"94_CR60","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.1097\/BRS.0b013e318074d604","volume":"32","author":"M Di Silvestre","year":"2007","unstructured":"Di Silvestre M, Parisini P, Lolli F et al (2007) Complications of thoracic pedicle screws in scoliosis treatment. Spine 32:1655\u20131661","journal-title":"Spine"},{"key":"94_CR61","doi-asserted-by":"crossref","first-page":"403","DOI":"10.3171\/2010.3.SPINE09657","volume":"13","author":"KC Foxx III","year":"2010","unstructured":"Foxx KC III, Kwak RC, Letzman JM et al (2010) A retrospective analysis of pedicle screw in contact with the great vessels. J Neurosurg Spine 13:403\u2013406","journal-title":"J Neurosurg Spine"},{"key":"94_CR62","unstructured":"Black JH, Manning WJ (2019) Management of acute aortic dissection [UpToDate website]. https:\/\/www.uptodate.com\/contents\/management-of-acute-aortic-dissection?search=Management%20of%20acute%20aortic%20dissection%20&source=search_result&selectedTitle=1~150&usage_type=default&display_rank=1. Accessed 2 July 2019"},{"key":"94_CR63","unstructured":"Woo YJ, Greene CL (2018) Overview of open surgical repair of the thoracic aorta [UpToDate website]. https:\/\/www.uptodate.com\/contents\/overview-of-open-surgical-repair-of-the-thoracic-aorta?search=Overview%20of%20open%20surgical%20repair%20of%20the%20thoracic%20aorta&source=search_result&selectedTitle=1~150&usage_type=default&display_rank=1. Accessed 2 July 2019"},{"key":"94_CR64","unstructured":"Jim J, Thompson RW (2019) Management of symptomatic (non-ruptured) and ruptured abdominal aortic aneurysm [UpToDate website]. https:\/\/www.uptodate.com\/contents\/management-of-symptomatic-non-ruptured-and-ruptured-abdominal-aortic-aneurysm?search=Management%20of%20symptomatic%20(non-ruptured)%20and%20ruptured%20abdominal%20aortic%20aneurysm&source=search_result&selectedTitle=1~150&usage_type=default&display_rank=1. Accessed 2 July 2019"},{"key":"94_CR65","unstructured":"Wang GJ, Fairman RM (2018) Endovascular repair of the thoracic aorta [UpToDate website]. https:\/\/www.uptodate.com\/contents\/endovascular-repair-of-the-thoracic-aorta?search=Endovascular%20repair%20of%20the%20thoracic%20aorta&source=search_result&selectedTitle=1~22&usage_type=default&display_rank=1. Accessed 2 July 2019"},{"key":"94_CR66","unstructured":"Woo YJ, Greene CL (2019) Clinical manifestations and diagnosis of thoracic aortic aneurysm [UpToDate website]. https:\/\/www.uptodate.com\/contents\/clinical-manifestations-and-diagnosis-of-thoracic-aortic-aneurysm?search=Clinical%20manifestations%20and%20diagnosis%20of%20thoracic%20aortic%20aneurysm&source=search_result&selectedTitle=1~110&usage_type=default&display_rank=1. Accessed 2 July 2019"}],"container-title":["Spine Deformity"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s43390-020-00094-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s43390-020-00094-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s43390-020-00094-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,13]],"date-time":"2021-03-13T00:49:08Z","timestamp":1615596548000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s43390-020-00094-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,3,13]]},"references-count":66,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2020,8]]}},"alternative-id":["94"],"URL":"https:\/\/doi.org\/10.1007\/s43390-020-00094-5","relation":{},"ISSN":["2212-134X","2212-1358"],"issn-type":[{"value":"2212-134X","type":"print"},{"value":"2212-1358","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,3,13]]},"assertion":[{"value":"2 August 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 February 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 March 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"All authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The patients were informed that data would be submitted for publication and agreed by signing a consent agreement.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"IRB approval\/Research Ethics Committee or equivalent is not required since this is a description of two case reports with review of the literature as opposed to a study. The patient\u2019s data in the manuscript\u2019s case reports were anonymized.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"IRB approval\/Research Ethics Committee"}}]}}