{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,24]],"date-time":"2026-07-24T17:41:18Z","timestamp":1784914878064,"version":"3.55.0"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2022,7,9]],"date-time":"2022-07-09T00:00:00Z","timestamp":1657324800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,7,9]],"date-time":"2022-07-09T00:00:00Z","timestamp":1657324800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Spine Deform"],"published-print":{"date-parts":[[2022,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>To estimate the criterion validity of sagittal thoracolumbar spine measurement using a surface topography method in a clinical population against the gold standard and to estimate concurrent validity against two non-radiographic clinical tools.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>In this cross-sectional validity study, thoracolumbar curvature was measured in adults with spinal conditions recruited from a specialist orthopaedic hospital. A surface topography method using a Kinect sensor was compared to three other measurement methods: spinal radiograph (gold standard), flexicurve and digital inclinometer. Correlation coefficients and agreement between the measurement tools were analysed.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Twenty-nine participants (79% female) were included in criterion validity analyses and 38 (76% female) in concurrent validity analyses. The surface topography method was moderately correlated with the radiograph (<jats:italic>r<\/jats:italic>\u2009=\u2009.70, <jats:italic>p<\/jats:italic>\u2009&lt;\u2009.001) in the thoracic spine, yet there was no significant correlation with the radiograph in the lumbar spine (<jats:italic>r<\/jats:italic>\u2009=\u2009.32, <jats:italic>p<\/jats:italic>\u2009=\u2009.89). The surface topography method was highly correlated with the flexicurve (<jats:italic>r<\/jats:italic><jats:sub>s<\/jats:sub>\u2009=\u2009.91, <jats:italic>p<\/jats:italic>\u2009&lt;\u2009.001) and digital inclinometer (<jats:italic>r<\/jats:italic>\u2009=\u2009.82, <jats:italic>p<\/jats:italic>\u2009&lt;\u2009.001) in the thoracic spine, and highly correlated with the flexicurve (<jats:italic>r<\/jats:italic>\u2009=\u2009.74, <jats:italic>p<\/jats:italic>\u2009&lt;\u2009.001) and digital inclinometer (<jats:italic>r<\/jats:italic>\u2009=\u2009.74, <jats:italic>p<\/jats:italic>\u2009&lt;\u2009.001) in the lumbar spine.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>The surface topography method showed moderate correlation and agreement in thoracic spine with the radiograph (criterion validity) and high correlation with the flexicurve and digital inclinometer (concurrent validity). Compared with other non-radiographic tools, this surface topography method displayed similar criterion validity for kyphosis curvature measurement.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s43390-022-00538-0","type":"journal-article","created":{"date-parts":[[2022,7,9]],"date-time":"2022-07-09T09:02:27Z","timestamp":1657357347000},"page":"1299-1306","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Validity of sagittal thoracolumbar curvature measurement using a non-radiographic surface topography method"],"prefix":"10.1007","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1422-4625","authenticated-orcid":false,"given":"Erin","family":"Hannink","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2933-5213","authenticated-orcid":false,"given":"Helen","family":"Dawes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas M. L.","family":"Shannon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9363-0383","authenticated-orcid":false,"given":"Karen L.","family":"Barker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,7,9]]},"reference":[{"key":"538_CR1","doi-asserted-by":"publisher","first-page":"352","DOI":"10.2519\/jospt.2010.3099","volume":"40","author":"WB Katzman","year":"2010","unstructured":"Katzman WB, Wanek L, Shepherd JA, Sellmeyer DE (2010) Age-related hyperkyphosis: its causes, consequences, and management. J Orthop Sports Phys Ther 40:352\u2013360. https:\/\/doi.org\/10.2519\/jospt.2010.3099","journal-title":"J Orthop Sports Phys Ther"},{"key":"538_CR2","doi-asserted-by":"publisher","first-page":"330","DOI":"10.7326\/0003-4819-147-5-200709040-00008","volume":"147","author":"DM Kado","year":"2007","unstructured":"Kado DM, Prenovost K, Crandall C (2007) Narrative review: hyperkyphosis in older persons. Ann Intern Med 147:330\u2013338","journal-title":"Ann Intern Med"},{"key":"538_CR3","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1007\/s12178-011-9101-z","volume":"4","author":"CR Good","year":"2011","unstructured":"Good CR, Auerbach JD, O\u2019Leary PT, Schuler TC (2011) Adult spine deformity. Curr Rev Musculoskelet Med 4:159\u2013167. https:\/\/doi.org\/10.1007\/s12178-011-9101-z","journal-title":"Curr Rev Musculoskelet Med"},{"key":"538_CR4","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1002\/jbmr.1728","volume":"28","author":"DM Kado","year":"2013","unstructured":"Kado DM, Huang M, Karlamangla A, Cawthon P, Katzman WB, Hillier T, Ensrud K, Cummings S (2013) Factors associated with kyphosis progression in older women: 15 years experience in the study of osteoporotic fractures. J Bone Miner Res 28:179\u2013187. https:\/\/doi.org\/10.1002\/jbmr.1728","journal-title":"J Bone Miner Res"},{"key":"538_CR5","doi-asserted-by":"publisher","first-page":"1351","DOI":"10.1097\/00007632-199520120-00005","volume":"20","author":"DE Gelb","year":"1995","unstructured":"Gelb DE, Lenke LG, Bridwell KH, Blanke K, McEnery KW (1995) An analysis of sagittal spinal alignment in 100 asymptomatic middle and older aged volunteers. Spine (Phila Pa 1976) 20:1351\u20131358","journal-title":"Spine (Phila Pa 1976)"},{"key":"538_CR6","doi-asserted-by":"publisher","first-page":"S164","DOI":"10.1227\/NEU.0000000000000944","volume":"77","author":"T Ailon","year":"2015","unstructured":"Ailon T, Shaffrey CI, Lenke LG, Harrop JS, Smith JS (2015) Progressive spinal kyphosis in the aging population. Neurosurgery 77:S164\u2013S172. https:\/\/doi.org\/10.1227\/NEU.0000000000000944","journal-title":"Neurosurgery"},{"key":"538_CR7","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1097\/00024720-200302000-00008","volume":"16","author":"EM Hammerberg","year":"2003","unstructured":"Hammerberg EM, Wood KB (2003) Sagittal profile of the elderly. J Spinal Disord Tech 16:44\u201350. https:\/\/doi.org\/10.1097\/00024720-200302000-00008","journal-title":"J Spinal Disord Tech"},{"key":"538_CR8","doi-asserted-by":"publisher","first-page":"857","DOI":"10.1007\/s40846-016-0184-2","volume":"36","author":"S Pohlmann","year":"2016","unstructured":"Pohlmann S, Harkness E, Taylor C, Astley S (2016) Evaluation of Kinect 3D sensor for healthcare imaging. J Med Biol Eng 36:857\u2013870. https:\/\/doi.org\/10.1007\/s40846-016-0184-2","journal-title":"J Med Biol Eng"},{"key":"538_CR9","first-page":"282","volume":"176","author":"T Shannon","year":"2012","unstructured":"Shannon T, Chockalingam N (2012) Investigating a low cost method to quantify cosmetic defect. Stud Health Technol Inform 176:282\u2013285","journal-title":"Stud Health Technol Inform"},{"key":"538_CR10","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4471-4658-2>","author":"M Hansard","year":"2012","unstructured":"Hansard M, Lee S, Choi O, Horaud R (2012) Time of flight cameras: principles, methods, and applications. SpringerBriefs Comput Sci. https:\/\/doi.org\/10.1007\/978-1-4471-4658-2%3e","journal-title":"SpringerBriefs Comput Sci"},{"key":"538_CR11","doi-asserted-by":"publisher","first-page":"645","DOI":"10.1016\/J.APERGO.2011.09.011","volume":"43","author":"T Dutta","year":"2012","unstructured":"Dutta T (2012) Evaluation of the Kinect\u2122 sensor for 3-D kinematic measurement in the workplace. Appl Ergon 43:645\u2013649. https:\/\/doi.org\/10.1016\/J.APERGO.2011.09.011","journal-title":"Appl Ergon"},{"key":"538_CR12","doi-asserted-by":"publisher","first-page":"976","DOI":"10.1016\/j.apergo.2013.12.001","volume":"45","author":"JA Diego-Mas","year":"2014","unstructured":"Diego-Mas JA, Alcaide-Marzal J (2014) Using Kinect\u2122 sensor in observational methods for assessing postures at work. Appl Ergon 45:976\u2013985. https:\/\/doi.org\/10.1016\/j.apergo.2013.12.001","journal-title":"Appl Ergon"},{"key":"538_CR13","doi-asserted-by":"publisher","first-page":"372","DOI":"10.1016\/j.gaitpost.2012.03.033","volume":"36","author":"RA Clark","year":"2012","unstructured":"Clark RA, Pua Y-H, Fortin K, Ritchie C, Webster KE, Denehy L, Bryant AL (2012) Validity of the Microsoft Kinect for assessment of postural control. Gait Posture 36:372\u2013377. https:\/\/doi.org\/10.1016\/j.gaitpost.2012.03.033","journal-title":"Gait Posture"},{"key":"538_CR14","doi-asserted-by":"publisher","first-page":"1062","DOI":"10.1016\/J.GAITPOST.2014.01.008","volume":"39","author":"B Galna","year":"2014","unstructured":"Galna B, Barry G, Jackson D, Mhiripiri D, Olivier P, Rochester L (2014) Accuracy of the Microsoft Kinect sensor for measuring movement in people with Parkinson\u2019s disease. Gait Posture 39:1062\u20131068. https:\/\/doi.org\/10.1016\/J.GAITPOST.2014.01.008","journal-title":"Gait Posture"},{"key":"538_CR15","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1016\/j.pbj.2016.11.004","volume":"2","author":"APG Castro","year":"2017","unstructured":"Castro APG, Pacheco JD, Louren\u00e7 OC, Queir\u00f3s S, Moreira AHJ, Rodrigues NF, Vila\u00e7 JL (2017) Evaluation of spinal posture using Microsoft Kinect TM: a preliminary case-study with 98 volunteers. Porto Biomed J 2:18\u201322. https:\/\/doi.org\/10.1016\/j.pbj.2016.11.004","journal-title":"Porto Biomed J"},{"key":"538_CR16","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1097\/MRR.0000000000000237","volume":"40","author":"J Quek","year":"2017","unstructured":"Quek J, Brauer SG, Treleaven J, Clark RA (2017) The concurrent validity and intrarater reliability of the Microsoft Kinect to measure thoracic kyphosis. Int J Rehabil Res 40:279\u2013284. https:\/\/doi.org\/10.1097\/MRR.0000000000000237","journal-title":"Int J Rehabil Res"},{"key":"538_CR17","doi-asserted-by":"publisher","first-page":"295","DOI":"10.3233\/BMR-191554","volume":"33","author":"E Hannink","year":"2020","unstructured":"Hannink E, Shannon T, Barker KL, Dawes H (2020) The reliability and reproducibility of sagittal spinal curvature measurement using the Microsoft Kinect V2. J Back Musculoskelet Rehabil 33:295\u2013301. https:\/\/doi.org\/10.3233\/BMR-191554","journal-title":"J Back Musculoskelet Rehabil"},{"key":"538_CR18","doi-asserted-by":"publisher","first-page":"593","DOI":"10.1007\/s00586-009-0913-0","volume":"18","author":"T Vrtovec","year":"2009","unstructured":"Vrtovec T, Pernu\u0161 F, Likar B (2009) A review of methods for quantitative evaluation of spinal curvature. Eur Spine J 18:593\u2013607. https:\/\/doi.org\/10.1007\/s00586-009-0913-0","journal-title":"Eur Spine J"},{"key":"538_CR19","doi-asserted-by":"publisher","first-page":"E235","DOI":"10.1097\/00007632-200106010-00003","volume":"26","author":"DE Harrison","year":"2001","unstructured":"Harrison DE, Harrison DD, Cailliet R, Janik TJ, Holland B (2001) Radiographic analysis of lumbar lordosis: centroid, Cobb, TRALL, and Harrison posterior tangent methods. Spine (Phila Pa 1976) 26:E235\u2013E242","journal-title":"Spine (Phila Pa 1976)"},{"key":"538_CR20","doi-asserted-by":"publisher","first-page":"761","DOI":"10.1007\/s00256-007-0284-8","volume":"36","author":"AM Briggs","year":"2007","unstructured":"Briggs AM, Wrigley TV, Tully EA, Adams PE, Greig AM, Bennell KL (2007) Radiographic measures of thoracic kyphosis in osteoporosis: Cobb and vertebral centroid angles. Skeletal Radiol 36:761\u2013767. https:\/\/doi.org\/10.1007\/s00256-007-0284-8","journal-title":"Skeletal Radiol"},{"key":"538_CR21","doi-asserted-by":"publisher","first-page":"140","DOI":"10.6063\/motricidade.6470","volume":"12","author":"JA Sedrez","year":"2016","unstructured":"Sedrez JA, Candotti CT, Furlanetto TS, Loss F (2016) Non-invasive postural assessment of the spine in the sagittal plane: a systematic review. Motricidade 12:140\u2013154","journal-title":"Motricidade"},{"key":"538_CR22","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.math.2013.09.003","volume":"19","author":"E Barrett","year":"2014","unstructured":"Barrett E, McCreesh K, Lewis J (2014) Reliability and validity of non-radiographic methods of thoracic kyphosis measurement: a systematic review. Man Ther 19:10\u201317","journal-title":"Man Ther"},{"key":"538_CR23","unstructured":"Mokkink LB, Prinsen CA, Patrick DL, Alonso J, Bouter LM, de Vet HC, Terwee CB (2019) COSMIN study design checklist for patient-reported outcome measurement instruments. In: COSMIN. https:\/\/www.cosmin.nl\/wp-content\/uploads\/COSMIN-study-designing-checklist_final.pdf"},{"key":"538_CR24","doi-asserted-by":"publisher","first-page":"1897","DOI":"10.1007\/s00198-010-1422-z","volume":"22","author":"GA Greendale","year":"2011","unstructured":"Greendale GA, Nili NS, Huang MH, Seeger L, Karlamangla AS (2011) The reliability and validity of three non-radiological measures of thoracic kyphosis and their relations to the standing radiological Cobb angle. Osteoporos Int 22:1897\u20131905. https:\/\/doi.org\/10.1007\/s00198-010-1422-z","journal-title":"Osteoporos Int"},{"key":"538_CR25","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fbioe.2021.687323","volume":"9","author":"P Severijns","year":"2021","unstructured":"Severijns P, Overbergh T, Schmid S, Moke L, Scheys L (2021) Spinal palpation error and its impact on skin marker-based spinal alignment measurement in adult spinal deformity. Front Bioeng Biotechnol 9:1\u20139. https:\/\/doi.org\/10.3389\/fbioe.2021.687323","journal-title":"Front Bioeng Biotechnol"},{"key":"538_CR26","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1016\/j.math.2008.06.002","volume":"14","author":"R Robinson","year":"2009","unstructured":"Robinson R, Robinson HS, Bj\u00f8rke G, Kvale A (2009) Reliability and validity of a palpation technique for identifying the spinous processes of C7 and L5. Man Ther 14:409\u2013414. https:\/\/doi.org\/10.1016\/j.math.2008.06.002","journal-title":"Man Ther"},{"key":"538_CR27","doi-asserted-by":"publisher","first-page":"e235","DOI":"10.1097\/00007632-200106010-00003","volume":"26","author":"DE Harrison","year":"2001","unstructured":"Harrison DE, Harrison DD, Cailliet R, Janik TJ, Holland B (2001) Radiographic analysis of lumbar lordosis. Spine (Phila Pa 1976) 26:e235\u2013e242. https:\/\/doi.org\/10.1097\/00007632-200106010-00003","journal-title":"Spine (Phila Pa 1976)"},{"key":"538_CR28","doi-asserted-by":"publisher","first-page":"E212","DOI":"10.1097\/BSD.0b013e31829a3574","volume":"27","author":"F Azadinia","year":"2014","unstructured":"Azadinia F, Kamyab M, Behtash, Saleh Ganjavian M, Javaheri MRM (2014) The validity and reliability of noninvasive methods for measuring kyphosis. J Spinal Disord Tech 27:E212\u2013E218. https:\/\/doi.org\/10.1097\/BSD.0b013e31829a3574","journal-title":"J Spinal Disord Tech"},{"key":"538_CR29","doi-asserted-by":"publisher","DOI":"10.4172\/2165-7939.1000170","author":"F Sangtarash","year":"2014","unstructured":"Sangtarash F, Manshadi FD, Sadeghi A, Tabatabaee SM, Gheysari AM (2014) Validity and reliability of dual digital inclinometer in measuring thoracic kyphosis in women over 45 years. J Spine. https:\/\/doi.org\/10.4172\/2165-7939.1000170","journal-title":"J Spine"},{"key":"538_CR30","volume-title":"Applied statistics for the behavioral sciences","author":"DE Hinkle","year":"2003","unstructured":"Hinkle DE, Wiersma W, Jurs SG (2003) Applied statistics for the behavioral sciences. Houghton Mifflin, Boston"},{"key":"538_CR31","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1590\/S1413-35552007000300005","volume":"11","author":"FA Teixeira","year":"2007","unstructured":"Teixeira FA, Carvalho GA (2007) Reliability and validity of thoracic kyphosis measurements using the flexicurve method. Rev Bras Fisioter 11:173\u2013177. https:\/\/doi.org\/10.1590\/S1413-35552007000300005","journal-title":"Rev Bras Fisioter"},{"key":"538_CR32","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-020-06402-x","author":"NL Krott","year":"2020","unstructured":"Krott NL, Wild M, Betsch M (2020) Meta-analysis of the validity and reliability of rasterstereographic measurements of spinal posture. Eur Spine J. https:\/\/doi.org\/10.1007\/s00586-020-06402-x","journal-title":"Eur Spine J"},{"key":"538_CR33","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/j.jmbbm.2016.11.025","volume":"67","author":"SM Beaudette","year":"2017","unstructured":"Beaudette SM, Zwambag DP, Bent LR, Brown SHM (2017) Spine postural change elicits localized skin structural deformation of the trunk dorsum in vivo. J Mech Behav Biomed Mater 67:31\u201339. https:\/\/doi.org\/10.1016\/j.jmbbm.2016.11.025","journal-title":"J Mech Behav Biomed Mater"},{"key":"538_CR34","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1016\/j.math.2011.01.007","volume":"16","author":"GN Kawchuk","year":"2011","unstructured":"Kawchuk GN, Prasad N, Parent E, Chapman S, Custodio M, Manzon M, Wiebe A, Dhillon S (2011) Spinal landmark depth in relation to body mass index. Man Ther 16:384\u2013387. https:\/\/doi.org\/10.1016\/j.math.2011.01.007","journal-title":"Man Ther"},{"key":"538_CR35","doi-asserted-by":"publisher","first-page":"2162","DOI":"10.1007\/s00586-019-06082-2","volume":"28","author":"L Wanke-Jellinek","year":"2019","unstructured":"Wanke-Jellinek L, Heese O, Krenauer A, Wurtinger C, Siepe CJ, Wiechert K, Mehren C (2019) Is there any use? Validity of 4D rasterstereography compared to EOS 3D X-ray imaging in patients with degenerative disk disease. Eur Spine J 28:2162\u20132168. https:\/\/doi.org\/10.1007\/s00586-019-06082-2","journal-title":"Eur Spine J"},{"key":"538_CR36","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1007\/s43390-020-00260-9","volume":"9","author":"A Applebaum","year":"2021","unstructured":"Applebaum A, Cho W, Nessim A, Kim K, Tarpada SP, Yoon SH, Pujar B, Kim D, Kim SY (2021) Establishing the validity of surface topography for assessment of scoliosis: a prospective study. Spine Deform 9:685\u2013689. https:\/\/doi.org\/10.1007\/s43390-020-00260-9","journal-title":"Spine Deform"},{"key":"538_CR37","doi-asserted-by":"publisher","first-page":"S329","DOI":"10.1016\/j.spinee.2017.10.042","volume":"17","author":"T Shannon","year":"2017","unstructured":"Shannon T, Chockalingam N, Jevti\u0107 N (2017) The radiological and clinical assessment of a cohort of AIS patients in serbia and bulgaria. Spine J 17:S329. https:\/\/doi.org\/10.1016\/j.spinee.2017.10.042","journal-title":"Spine J"},{"key":"538_CR38","doi-asserted-by":"publisher","first-page":"625","DOI":"10.1016\/J.EJRAD.2015.12.032","volume":"85","author":"M Law","year":"2016","unstructured":"Law M, Ma W-K, Lau D, Chan E, Yip L, Lam W (2016) Cumulative radiation exposure and associated cancer risk estimates for scoliosis patients: Impact of repetitive full spine radiography. Eur J Radiol 85:625\u2013628. https:\/\/doi.org\/10.1016\/J.EJRAD.2015.12.032","journal-title":"Eur J Radiol"},{"key":"538_CR39","doi-asserted-by":"publisher","DOI":"10.1016\/j.critrevonc.2021.103292","volume":"160","author":"LG Marcu","year":"2021","unstructured":"Marcu LG, Chau M, Bezak E (2021) How much is too much? Systematic review of cumulative doses from radiological imaging and the risk of cancer in children and young adults. Crit Rev Oncol Hematol 160:103292. https:\/\/doi.org\/10.1016\/j.critrevonc.2021.103292","journal-title":"Crit Rev Oncol Hematol"}],"container-title":["Spine Deformity"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s43390-022-00538-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s43390-022-00538-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s43390-022-00538-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,18]],"date-time":"2022-10-18T10:39:47Z","timestamp":1666089587000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s43390-022-00538-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,9]]},"references-count":39,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2022,11]]}},"alternative-id":["538"],"URL":"https:\/\/doi.org\/10.1007\/s43390-022-00538-0","relation":{},"ISSN":["2212-134X","2212-1358"],"issn-type":[{"value":"2212-134X","type":"print"},{"value":"2212-1358","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,9]]},"assertion":[{"value":"8 February 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 May 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 July 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no competing interests to declare that are relevant to the content of this article.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study was approved by the South West\u2014Central Bristol Research Ethics Committee, ref: 17\/SW\/0239. All participants provided signed informed consent to participate in this study, which was carried out in accordance with the Declaration of Helsinki.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}}]}}