{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T15:42:11Z","timestamp":1791042131415,"version":"4.1.0"},"reference-count":46,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2024,4,15]],"date-time":"2024-04-15T00:00:00Z","timestamp":1713139200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,4,15]],"date-time":"2024-04-15T00:00:00Z","timestamp":1713139200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Spine Deform"],"published-print":{"date-parts":[[2024,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>The role of robotics in spine surgery remains controversial, especially for scoliosis correction surgery. This study aims to assess the safety and efficacy of robotic-assisted (RA) surgery specifically for scoliosis surgery by comparing RA to both navigation systems (NS) and conventional freehand techniques (CF).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>As per the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines, a systematic review and meta-analysis were conducted via an electronic search of the following databases: MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials (CENTRAL). All papers comparing RA to either NS or CF for posterior spinal fusion in scoliosis were included. Fixed and random effects models of analysis were utilised based on analysis heterogeneity.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>10 observational studies were included in total. RA had significantly greater odds of accurate pedicle screw placement relative to both NS (OR\u2009=\u20092.02, CI\u2009=\u20091.52\u20132.67, p\u2009&lt;\u20090.00001) and CF (OR\u2009=\u20093.06, CI\u2009=\u20091.79\u20135.23, p\u2009&lt;\u20090.00001). The downside of RA was the significantly greater operation duration relative to NS (MD\u2009=\u200910.74, CI\u2009=\u20093.52\u201317.97, p\u2009=\u20090.004) and CF (MD\u2009=\u200940.27, CI\u2009=\u200920.90, p\u2009&lt;\u20090.0001). Perioperative outcomes including estimated blood loss, radiation exposure, length of hospital stay, cobb angle correction rate, postoperative SRS score, VAS pain score, JOA score, as well as rates of neurological injury and revision surgery, were comparable between the groups (p\u2009&gt;\u20090.05).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>RA offers significantly greater pedicle screw placement accuracy relative to NS and CF, however, surgery can take longer. In terms of perioperative outcomes, all three techniques are comparable.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s43390-024-00879-y","type":"journal-article","created":{"date-parts":[[2024,4,15]],"date-time":"2024-04-15T10:02:39Z","timestamp":1713175359000},"page":"1203-1215","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":33,"title":["Robot-assisted pedicle screw insertion versus navigation-based and freehand techniques for posterior spinal fusion in scoliosis: a systematic review and meta-analysis"],"prefix":"10.1007","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4667-9402","authenticated-orcid":false,"given":"Abdulrahman O.","family":"Al-Naseem","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdullah","family":"Al-Muhannadi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammad","family":"Ramadhan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alwaleed","family":"Alfadhli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yousef","family":"Marwan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roozbeh","family":"Shafafy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammad M.","family":"Abd-El-Barr","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,4,15]]},"reference":[{"issue":"9","key":"879_CR1","doi-asserted-by":"publisher","first-page":"771","DOI":"10.1093\/pch\/12.9.771","volume":"12","author":"JA Janicki","year":"2007","unstructured":"Janicki JA, Alman B (2007) Scoliosis: review of diagnosis and treatment (in Eng). Paediatr Child Health 12(9):771\u2013776. https:\/\/doi.org\/10.1093\/pch\/12.9.771","journal-title":"Paediatr Child Health"},{"issue":"10","key":"879_CR2","doi-asserted-by":"publisher","first-page":"925","DOI":"10.1007\/s00586-005-1053-9","volume":"14","author":"M Aebi","year":"2005","unstructured":"Aebi M (2005) The adult scoliosis (in Eng). Eur Spine J 14(10):925\u2013948. https:\/\/doi.org\/10.1007\/s00586-005-1053-9","journal-title":"Eur Spine J"},{"key":"879_CR3","doi-asserted-by":"publisher","first-page":"154","DOI":"10.25259\/sni_67_2022","volume":"13","author":"EB Harfouch","year":"2022","unstructured":"Harfouch EB, Bunyan RF, Faraidy MA, Alnemari HH, Bashir S (2022) Ponte osteotomies increase risk of intraoperative neuromonitoring alerts in adolescent idiopathic scoliosis surgery (in Eng). Surg Neurol Int 13:154. https:\/\/doi.org\/10.25259\/sni_67_2022","journal-title":"Surg Neurol Int"},{"key":"879_CR4","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1007\/s43390-023-00745-3","volume":"12","author":"MC Gupta","year":"2023","unstructured":"Gupta MC et al (2023) Intraoperative neuromonitoring predicts postoperative deficits in severe pediatric spinal deformity patients (in Eng). Spine Deform 12:109\u2013118. https:\/\/doi.org\/10.1007\/s43390-023-00745-3","journal-title":"Spine Deform"},{"issue":"3","key":"879_CR5","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1097\/01.brs.0000109983.12113.9b","volume":"29","author":"YJ Kim","year":"2004","unstructured":"Kim YJ, Lenke LG, Bridwell KH, Cho YS, Riew KD (2004) Free hand pedicle screw placement in the thoracic spine: is it safe? Spine (Phila Pa 1976) 29(3):333\u2013342. https:\/\/doi.org\/10.1097\/01.brs.0000109983.12113.9b","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"879_CR6","doi-asserted-by":"publisher","first-page":"86","DOI":"10.21037\/atm-2020-ioi-07","volume":"9","author":"M Huang","year":"2021","unstructured":"Huang M, Tetreault TA, Vaishnav A, York PJ, Staub BN (2021) The current state of navigation in robotic spine surgery (in Eng). Ann Transl Med 9(1):86. https:\/\/doi.org\/10.21037\/atm-2020-ioi-07","journal-title":"Ann Transl Med"},{"key":"879_CR7","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1016\/j.ijsp.2011.11.002","volume":"6","author":"JN Sembrano","year":"2012","unstructured":"Sembrano JN, Polly DW Jr, Ledonio CG, Santos ER (2012) Intraoperative 3-dimensional imaging (O-arm) for assessment of pedicle screw position: Does it prevent unacceptable screw placement? (in Eng). Int J Spine Surg 6:49\u201354. https:\/\/doi.org\/10.1016\/j.ijsp.2011.11.002","journal-title":"Int J Spine Surg"},{"issue":"2","key":"879_CR8","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1016\/j.spinee.2022.10.006","volume":"23","author":"AV Matur","year":"2023","unstructured":"Matur AV, Palmisciano P, Duah HO, Chilakapati SS, Cheng JS, Adogwa O (2023) Robotic and navigated pedicle screws are safer and more accurate than fluoroscopic freehand screws: a systematic review and meta-analysis (in Eng). Spine J 23(2):197\u2013208. https:\/\/doi.org\/10.1016\/j.spinee.2022.10.006","journal-title":"Spine J"},{"issue":"2","key":"879_CR9","doi-asserted-by":"publisher","first-page":"e0020","DOI":"10.2106\/jbjs.St.19.00020","volume":"10","author":"IH Lieberman","year":"2020","unstructured":"Lieberman IH, Kisinde S, Hesselbacher S (2020) Robotic-assisted pedicle ecrew placement during spine surgery. JBJS Essent Surg Tech 10(2):e0020. https:\/\/doi.org\/10.2106\/jbjs.St.19.00020","journal-title":"JBJS Essent Surg Tech"},{"issue":"3","key":"879_CR10","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1007\/s00586-012-2499-1","volume":"22","author":"X Hu","year":"2013","unstructured":"Hu X, Ohnmeiss DD, Lieberman IH (2013) Robotic-assisted pedicle screw placement: lessons learned from the first 102 patients (in Eng). Eur Spine J 22(3):661\u2013666. https:\/\/doi.org\/10.1007\/s00586-012-2499-1","journal-title":"Eur Spine J"},{"issue":"7","key":"879_CR11","doi-asserted-by":"publisher","first-page":"e1000097","DOI":"10.1371\/journal.pmed.1000097","volume":"6","author":"D Moher","year":"2009","unstructured":"Moher D, Liberati A, Tetzlaff J, Altman DG (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement (in Eng). PLoS Med 6(7):e1000097. https:\/\/doi.org\/10.1371\/journal.pmed.1000097","journal-title":"PLoS Med"},{"issue":"1","key":"879_CR12","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1097\/00007632-199001000-00004","volume":"15","author":"SD Gertzbein","year":"1990","unstructured":"Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement In vivo. Spine 15(1):11\u201314","journal-title":"Spine"},{"key":"879_CR13","unstructured":"S. B. Wells GA, O\u2018Connell D, Peterson J, Welch V, Losos M, et al. . \"The newcastle-ottawa scale (NOS) for assessing the quality of nonrandomized studies in meta-analyses \" www.ohri.ca\/programs\/clinical_epidemiology\/oxford.htm (accessed 10th Aug 2023)."},{"issue":"11","key":"879_CR14","doi-asserted-by":"publisher","first-page":"e49061","DOI":"10.7759\/cureus.49061","volume":"15","author":"T Akazawa","year":"2023","unstructured":"Akazawa T et al (2023) Comparison of radiographic and patient-reported outcomes after surgery in adolescent idiopathic scoliosis between robotics and navigation: an analysis using propensity score matching (in Eng). Cureus 15(11):e49061. https:\/\/doi.org\/10.7759\/cureus.49061","journal-title":"Cureus"},{"issue":"1","key":"879_CR15","doi-asserted-by":"publisher","first-page":"890","DOI":"10.1038\/s41598-017-19054-7","volume":"8","author":"Y Fan","year":"2018","unstructured":"Fan Y, Peng Du J, Liu JJ, Zhang JN, Liu SC, Hao DJ (2018) Radiological and clinical differences among three assisted technologies in pedicle screw fixation of adult degenerative scoliosis (in Eng). Sci Rep 8(1):890. https:\/\/doi.org\/10.1038\/s41598-017-19054-7","journal-title":"Sci Rep"},{"issue":"9","key":"879_CR16","doi-asserted-by":"publisher","first-page":"3094","DOI":"10.1007\/s00586-023-07710-8","volume":"32","author":"C Li","year":"2023","unstructured":"Li C et al (2023) Safety and accuracy of cannulated pedicle screw placement in scoliosis surgery: a comparison of robotic-navigation, O-arm-based navigation, and freehand techniques (in Eng). Eur Spine J 32(9):3094\u20133104. https:\/\/doi.org\/10.1007\/s00586-023-07710-8","journal-title":"Eur Spine J"},{"issue":"5","key":"879_CR17","first-page":"3254","volume":"15","author":"S Li","year":"2023","unstructured":"Li S et al (2023) Comparison of surgical efficacy between O-arm combined with CT 3D real-time navigation system and Tinavi robot-assisted treatment of adolescent congenital scoliosis (in Eng). Am J Transl Res 15(5):3254\u20133266","journal-title":"Am J Transl Res"},{"issue":"1","key":"879_CR18","doi-asserted-by":"publisher","first-page":"282","DOI":"10.1186\/s13018-020-01796-2","volume":"15","author":"X Chen","year":"2020","unstructured":"Chen X et al (2020) Robot-assisted orthopedic surgery in the treatment of adult degenerative scoliosis: a preliminary clinical report (in Eng). J Orthop Surg Res 15(1):282. https:\/\/doi.org\/10.1186\/s13018-020-01796-2","journal-title":"J Orthop Surg Res"},{"issue":"11","key":"879_CR19","doi-asserted-by":"publisher","first-page":"1457","DOI":"10.7507\/1002-1892.202106072","volume":"35","author":"H Chen","year":"2021","unstructured":"Chen H, Zhu X, Dong L, Liu T (2021) [Study on robot-assisted pedicle screw implantation in adolescent idiopathic scoliosis surgery] (in Chi). Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi 35(11):1457\u20131462. https:\/\/doi.org\/10.7507\/1002-1892.202106072","journal-title":"Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi"},{"key":"879_CR20","doi-asserted-by":"publisher","first-page":"1085580","DOI":"10.3389\/fsurg.2022.1085580","volume":"9","author":"C Hou","year":"2022","unstructured":"Hou C et al (2022) Comparison of robot versus fluoroscopy-assisted pedicle screw instrumentation in adolescent idiopathic scoliosis surgery: A retrospective study (in Eng). Front Surg 9:1085580. https:\/\/doi.org\/10.3389\/fsurg.2022.1085580","journal-title":"Front Surg"},{"key":"879_CR21","doi-asserted-by":"publisher","unstructured":"C. Li et al., \"Comparison of the Accuracy of Pedicle Screw Placement Using a Fluoroscopy-Assisted Free-Hand Technique with Robotic-Assisted Navigation Using an O-Arm or 3D C-Arm in Scoliosis Surgery,\" Global Spine Journal, vol. 0, no. 0, p. 21925682221143076, doi: https:\/\/doi.org\/10.1177\/21925682221143076.","DOI":"10.1177\/21925682221143076"},{"issue":"36","key":"879_CR22","doi-asserted-by":"publisher","first-page":"5790","DOI":"10.12307\/2023.775","volume":"27","author":"GM Xin Xiaoming","year":"2023","unstructured":"Xin Xiaoming GM, Fan Z, Fei C, Junchao F, Wenyuan L (2023) Application of orthopedic robot-assisted screw placement in the correction of adolescent idiopathic scoliosis. Chinese Journal of Tissue Engineering Research 27(36):5790\u20135794. https:\/\/doi.org\/10.12307\/2023.775","journal-title":"Chinese Journal of Tissue Engineering Research"},{"issue":"14","key":"879_CR23","doi-asserted-by":"publisher","first-page":"5204","DOI":"10.3390\/s22145204","volume":"22","author":"GS Linden","year":"2022","unstructured":"Linden GS, Ghessese S, Cook D, Hedequist DJ (2022) Pedicle screw placement in adolescent idiopathic scoliosis: a comparison between robotics coupled with navigation versus the freehand technique. Sensors (Basel) 22(14):5204. https:\/\/doi.org\/10.3390\/s22145204","journal-title":"Sensors (Basel)"},{"issue":"4","key":"879_CR24","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.24258","volume":"14","author":"AO Al-Naseem","year":"2022","unstructured":"Al-Naseem AO, Gonnah AR, Al-Ali H, Al-Naseem AO, Siddique I (2022) Robot-assisted versus conventional freehand fluoroscopy-guided percutaneous screw fixation in femoral neck fractures: a systematic review and meta-analysis (in Eng). Cureus 14(4):e24258. https:\/\/doi.org\/10.7759\/cureus.24258","journal-title":"Cureus"},{"issue":"1","key":"879_CR25","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1007\/s00590-021-03167-x","volume":"33","author":"A Al-Naseem","year":"2023","unstructured":"Al-Naseem A, Sallam A, Gonnah A, Masoud O, Abd-El-Barr MM, Aleem IS (2023) Robot-assisted versus conventional percutaneous sacroiliac screw fixation for posterior pelvic ring injuries: a systematic review and meta-analysis (in Eng). Eur J Orthop Surg Traumatol 33(1):9\u201320. https:\/\/doi.org\/10.1007\/s00590-021-03167-x","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"8","key":"879_CR26","doi-asserted-by":"publisher","first-page":"2639","DOI":"10.1007\/s00167-021-06472-4","volume":"30","author":"N Kort","year":"2022","unstructured":"Kort N, Stirling P, Pilot P, M\u00fcller JH (2022) Robot-assisted knee arthroplasty improves component positioning and alignment, but results are inconclusive on whether it improves clinical scores or reduces complications and revisions: a systematic overview of meta-analyses (in Eng). Knee Surg Sports Traumatol Arthrosc 30(8):2639\u20132653. https:\/\/doi.org\/10.1007\/s00167-021-06472-4","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"1171","key":"879_CR27","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1136\/postgradmedj-2021-141135","volume":"99","author":"V Kumar","year":"2023","unstructured":"Kumar V, Patel S, Baburaj V, Rajnish RK, Aggarwal S (2023) Does robotic-assisted surgery improve outcomes of total hip arthroplasty compared to manual technique? A systematic review and meta-analysis (in Eng). Postgrad Med J 99(1171):375\u2013383. https:\/\/doi.org\/10.1136\/postgradmedj-2021-141135","journal-title":"Postgrad Med J"},{"issue":"11","key":"879_CR28","doi-asserted-by":"publisher","first-page":"841","DOI":"10.1530\/eor-23-0125","volume":"8","author":"WX Sun","year":"2023","unstructured":"Sun WX et al (2023) Clinical efficacy of robotic spine surgery: an updated systematic review of 20 randomized controlled trials (in Eng). EFORT Open Rev 8(11):841\u2013853. https:\/\/doi.org\/10.1530\/eor-23-0125","journal-title":"EFORT Open Rev"},{"issue":"2","key":"879_CR29","first-page":"240","volume":"78","author":"C Schizas","year":"2012","unstructured":"Schizas C, Thein E, Kwiatkowski B, Kulik G (2012) Pedicle screw insertion: robotic assistance versus conventional C-arm fluoroscopy (in Eng). Acta Orthop Belg 78(2):240\u2013245","journal-title":"Acta Orthop Belg"},{"issue":"7","key":"879_CR30","doi-asserted-by":"publisher","first-page":"1830","DOI":"10.1007\/s11999-010-1280-1","volume":"468","author":"HN Modi","year":"2010","unstructured":"Modi HN, Suh SW, Hong JY, Yang JH (2010) Accuracy of thoracic pedicle screw using ideal pedicle entry point in severe scoliosis (in Eng). Clin Orthop Relat Res 468(7):1830\u20131837. https:\/\/doi.org\/10.1007\/s11999-010-1280-1","journal-title":"Clin Orthop Relat Res"},{"issue":"Suppl 5","key":"879_CR31","doi-asserted-by":"publisher","first-page":"S165","DOI":"10.21037\/atm.2019.07.93","volume":"7","author":"MS Galetta","year":"2019","unstructured":"Galetta MS, Leider JD, Divi SN, Goyal DKC, Schroeder GD (2019) Robotics in spinal surgery (in Eng). Ann Transl Med 7(Suppl 5):S165. https:\/\/doi.org\/10.21037\/atm.2019.07.93","journal-title":"Ann Transl Med"},{"issue":"1","key":"879_CR32","doi-asserted-by":"publisher","first-page":"E4","DOI":"10.3171\/2021.10.Focus21526","volume":"52","author":"KA Shafi","year":"2022","unstructured":"Shafi KA et al (2022) Does robot-assisted navigation influence pedicle screw selection and accuracy in minimally invasive spine surgery? (in Eng). Neurosurg Focus 52(1):E4. https:\/\/doi.org\/10.3171\/2021.10.Focus21526","journal-title":"Neurosurg Focus"},{"issue":"1","key":"879_CR33","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1007\/s43390-021-00403-6","volume":"10","author":"J Sielatycki","year":"2021","unstructured":"Sielatycki J, Mitchell K, Leung E, Lehman R (2021) State of the art review of new technologies in spine deformity surgery\u2013robotics and navigation. Spine Deform 10(1):5\u201317. https:\/\/doi.org\/10.1007\/s43390-021-00403-6","journal-title":"Spine Deform"},{"issue":"4","key":"879_CR34","doi-asserted-by":"publisher","first-page":"575","DOI":"10.1177\/2192568220927713","volume":"11","author":"AM Tarawneh","year":"2021","unstructured":"Tarawneh AM, Salem KM (2021) A Systematic review and Meta-analysis of randomized controlled trials comparing the accuracy and clinical outcome of pedicle screw placement using robot-assisted technology and conventional freehand technique (in Eng). Global Spine J 11(4):575\u2013586. https:\/\/doi.org\/10.1177\/2192568220927713","journal-title":"Global Spine J"},{"key":"879_CR35","doi-asserted-by":"publisher","first-page":"e625","DOI":"10.1016\/j.wneu.2020.05.257","volume":"141","author":"A Khan","year":"2020","unstructured":"Khan A et al (2020) Comparing cortical bone trajectories for pedicle screw insertion using robotic guidance and three-dimensional computed tomography navigation (in Eng). World Neurosurg 141:e625\u2013e632. https:\/\/doi.org\/10.1016\/j.wneu.2020.05.257","journal-title":"World Neurosurg"},{"issue":"1","key":"879_CR36","doi-asserted-by":"publisher","first-page":"E9","DOI":"10.3171\/2021.10.Focus21514","volume":"52","author":"MC Lin","year":"2022","unstructured":"Lin MC, Liu HW, Su YK, Lo WL, Lin CM (2022) Robot-guided versus freehand fluoroscopy-guided minimally invasive transforaminal lumbar interbody fusion: a single-institution, observational, case-control study (in Eng). Neurosurg Focus 52(1):E9. https:\/\/doi.org\/10.3171\/2021.10.Focus21514","journal-title":"Neurosurg Focus"},{"issue":"6","key":"879_CR37","doi-asserted-by":"publisher","first-page":"1531","DOI":"10.1007\/s00264-020-04825-1","volume":"45","author":"JN Zhang","year":"2021","unstructured":"Zhang JN, Fan Y, He X, Liu TJ, Hao DJ (2021) Comparison of robot-assisted and freehand pedicle screw placement for lumbar revision surgery (in Eng). Int Orthop 45(6):1531\u20131538. https:\/\/doi.org\/10.1007\/s00264-020-04825-1","journal-title":"Int Orthop"},{"issue":"4","key":"879_CR38","doi-asserted-by":"publisher","first-page":"547","DOI":"10.1055\/s-0042-1757628","volume":"17","author":"V Ong","year":"2022","unstructured":"Ong V et al (2022) A comparison of spinal robotic systems and pedicle screw accuracy rates: review of literature and meta-analysis (in Eng). Asian J Neurosurg 17(4):547\u2013556. https:\/\/doi.org\/10.1055\/s-0042-1757628","journal-title":"Asian J Neurosurg"},{"issue":"33","key":"879_CR39","doi-asserted-by":"publisher","first-page":"10134","DOI":"10.12998\/wjcc.v9.i33.10134","volume":"9","author":"J Yu","year":"2021","unstructured":"Yu J, Zhang Q, Fan MX, Han XG, Liu B, Tian W (2021) Learning curves of robot-assisted pedicle screw fixations based on the cumulative sum test (in Eng). World J Clin Cases 9(33):10134\u201310142. https:\/\/doi.org\/10.12998\/wjcc.v9.i33.10134","journal-title":"World J Clin Cases"},{"issue":"3","key":"879_CR40","doi-asserted-by":"publisher","first-page":"216","DOI":"10.14245\/ns.1836082.041","volume":"15","author":"RP Menger","year":"2018","unstructured":"Menger RP, Savardekar AR, Farokhi F, Sin A (2018) A cost-effectiveness analysis of the integration of robotic spine technology in spine surgery (in Eng). Neurospine 15(3):216\u2013224. https:\/\/doi.org\/10.14245\/ns.1836082.041","journal-title":"Neurospine"},{"issue":"5","key":"879_CR41","doi-asserted-by":"publisher","first-page":"2151","DOI":"10.21037\/tau.2019.11.33","volume":"10","author":"AA Shah","year":"2021","unstructured":"Shah AA, Bandari J, Pelzman D, Davies BJ, Jacobs BL (2021) Diffusion and adoption of the surgical robot in urology (in Eng). Transl Androl Urol 10(5):2151\u20132157. https:\/\/doi.org\/10.21037\/tau.2019.11.33","journal-title":"Transl Androl Urol"},{"issue":"2","key":"879_CR42","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1016\/j.suc.2019.12.008","volume":"100","author":"RD Jara","year":"2020","unstructured":"Jara RD, Guerr\u00f3n AD, Portenier D (2020) Complications of robotic surgery. Surg Clin North Am 100(2):461\u2013468. https:\/\/doi.org\/10.1016\/j.suc.2019.12.008","journal-title":"Surg Clin North Am"},{"issue":"5","key":"879_CR43","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1016\/j.jspd.2019.04.002","volume":"7","author":"R Sethi","year":"2019","unstructured":"Sethi R, Bohl M, Vitale M (2019) State-of-the-art reviews: safety in complex spine surgery (in Eng). Spine Deform 7(5):657\u2013668. https:\/\/doi.org\/10.1016\/j.jspd.2019.04.002","journal-title":"Spine Deform"},{"key":"879_CR44","doi-asserted-by":"publisher","first-page":"39","DOI":"10.2147\/rsrr.S70552","volume":"4","author":"BT Carpenter","year":"2017","unstructured":"Carpenter BT, Sundaram CP (2017) Training the next generation of surgeons in robotic surgery (in Eng). Robot Surg 4:39\u201344. https:\/\/doi.org\/10.2147\/rsrr.S70552","journal-title":"Robot Surg"},{"key":"879_CR45","doi-asserted-by":"publisher","unstructured":"A. O. Al-Naseem et al., \"Does spinal cord type predict intraoperative neuro-monitoring alerts in scoliosis correction surgery? a systematic review and meta-analysis of operative and radiologic predictors,\" Global Spine J, vol. 0, no. 0, p. 21925682241237475, doi: https:\/\/doi.org\/10.1177\/21925682241237475.","DOI":"10.1177\/21925682241237475"},{"issue":"5","key":"879_CR46","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1016\/j.jspd.2014.05.003","volume":"2","author":"MG Vitale","year":"2014","unstructured":"Vitale MG et al (2014) Best practices in intraoperative neuromonitoring in spine deformity surgery: development of an intraoperative checklist to optimize response (in Eng). Spine Deform 2(5):333\u2013339. https:\/\/doi.org\/10.1016\/j.jspd.2014.05.003","journal-title":"Spine Deform"}],"container-title":["Spine Deformity"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s43390-024-00879-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s43390-024-00879-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s43390-024-00879-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,23]],"date-time":"2024-08-23T23:15:38Z","timestamp":1724454938000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s43390-024-00879-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,15]]},"references-count":46,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2024,9]]}},"alternative-id":["879"],"URL":"https:\/\/doi.org\/10.1007\/s43390-024-00879-y","relation":{},"ISSN":["2212-134X","2212-1358"],"issn-type":[{"value":"2212-134X","type":"print"},{"value":"2212-1358","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,15]]},"assertion":[{"value":"14 February 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 April 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 April 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The author(s) declared that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"Not Applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Not Applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The datasets generated and analysed during the current study are available from the corresponding author on reasonable request.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Data availability"}}]}}