{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T04:42:46Z","timestamp":1781325766616,"version":"3.54.1"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2025,8,11]],"date-time":"2025-08-11T00:00:00Z","timestamp":1754870400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,8,11]],"date-time":"2025-08-11T00:00:00Z","timestamp":1754870400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Spine Deform"],"published-print":{"date-parts":[[2025,11]]},"DOI":"10.1007\/s43390-025-01154-4","type":"journal-article","created":{"date-parts":[[2025,8,11]],"date-time":"2025-08-11T13:49:37Z","timestamp":1754920177000},"page":"1781-1787","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["False negative intraoperative neuromonitoring alerts during pediatric spinal deformity surgery: the dreaded outcome"],"prefix":"10.1007","volume":"13","author":[{"given":"Hilton C.","family":"Braithwaite IV","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chris","family":"Bozorgmehr","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leah","family":"Rakers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3656-5962","authenticated-orcid":false,"given":"Scott J.","family":"Luhmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,8,11]]},"reference":[{"issue":"12","key":"1154_CR1","doi-asserted-by":"publisher","first-page":"1392","DOI":"10.1097\/00007632-199806150-00018","volume":"23","author":"AM Padberg","year":"1998","unstructured":"Padberg AM, Wilson-Holden TJ, Lenke LG, Bridwell KHMD (1998) Somatosensory- and motor-evoked potential monitoring without a wake-up test during idiopathic scoliosis surgery: an accepted standard of care. Spine 23(12):1392\u20131400","journal-title":"Spine"},{"issue":"2","key":"1154_CR2","doi-asserted-by":"publisher","first-page":"E101","DOI":"10.1097\/BRS.0b013e31827aafb9","volume":"38","author":"BL Raynor","year":"2013","unstructured":"Raynor BL, Bright JD, Lenke LG, Rahman RK, Bridwell KH, Riew KD, Buchowski JM, Luhmann SJ, Padberg AM (2013) Significant change or loss of intraoperative monitoring data: a 25-year experience in 12,375 spinal surgeries. Spine (Phila Pa 1976) 38(2):E101\u2013E108. https:\/\/doi.org\/10.1097\/BRS.0b013e31827aafb9. (PMID: 23124262)","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"1154_CR3","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1016\/0013-4694(94)00235-d","volume":"96","author":"MR Nuwer","year":"1995","unstructured":"Nuwer MR, Dawson EG, Carlson LG, Kanim LE, Sherman JE (1995) Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery: results of a large multicenter survey. Electroencephalogr Clin Neurophysiol 96(1):6\u201311. https:\/\/doi.org\/10.1016\/0013-4694(94)00235-d","journal-title":"Electroencephalogr Clin Neurophysiol"},{"issue":"5","key":"1154_CR4","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1097\/ACO.0b013e32830f1fbd","volume":"21","author":"TB Sloan","year":"2008","unstructured":"Sloan TB, Janik D, Jameson L (2008) Multimodality monitoring of the central nervous system using motor-evoked potentials. Curr Opin Anaesthesiol 21(5):560\u2013564. https:\/\/doi.org\/10.1097\/ACO.0b013e32830f1fbd","journal-title":"Curr Opin Anaesthesiol"},{"issue":"20","key":"1154_CR5","doi-asserted-by":"publisher","first-page":"1880","DOI":"10.1097\/BRS.0b013e3181e53434","volume":"35","author":"ED Thuet","year":"2010","unstructured":"Thuet ED, Winscher JC, Padberg AM, Bridwell KH, Lenke LG, Dobbs MB, Schootman M, Luhmann SJ (2010) Validity and reliability of intraoperative monitoring in pediatric spinal deformity surgery: a 23-year experience of 3436 surgical cases. Spine (Phila Pa 1976) 35(20):1880\u20131886. https:\/\/doi.org\/10.1097\/BRS.0b013e3181e53434","journal-title":"Spine (Phila Pa 1976)"},{"issue":"6","key":"1154_CR6","doi-asserted-by":"publisher","first-page":"1427","DOI":"10.1007\/s43390-023-00743-5","volume":"11","author":"SC Troyer","year":"2023","unstructured":"Troyer SC, Ribaudo JG, Raynor B, Zertan C, Kelly BA, Kelly MP, Luhmann SJ (2023) The adjunct use of descending neurogenic-evoked potentials when transcranial motor-evoked potentials degrade into warning criteria in pediatric spinal deformity surgery: minimizing false-positive events. Spine Deform 11(6):1427\u20131433. https:\/\/doi.org\/10.1007\/s43390-023-00743-5","journal-title":"Spine Deform"},{"issue":"2","key":"1154_CR7","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1016\/j.spinee.2017.07.005","volume":"18","author":"AA Tamkus","year":"2018","unstructured":"Tamkus AA, Rice KS, McCaffrey MT (2018) Perils of intraoperative neurophysiological monitoring: analysis of \u201cfalse-negative\u201d results in spine surgeries. Spine J 18(2):276\u2013284. https:\/\/doi.org\/10.1016\/j.spinee.2017.07.005","journal-title":"Spine J"},{"issue":"2","key":"1154_CR8","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1097\/WNP.0b013e31824ff6d0","volume":"29","author":"M Eccher","year":"2012","unstructured":"Eccher M (2012) Intraoperative neurophysiologic monitoring: are we really that bad? J Clin Neurophysiol 29(2):157\u2013159. https:\/\/doi.org\/10.1097\/WNP.0b013e31824ff6d0","journal-title":"J Clin Neurophysiol"},{"issue":"17","key":"1154_CR9","doi-asserted-by":"publisher","first-page":"1387","DOI":"10.1097\/BRS.0000000000001531","volume":"41","author":"BL Raynor","year":"2016","unstructured":"Raynor BL, Padberg AM, Lenke LG, Bridwell KH, Riew KD, Buchowski JM, Luhmann SJ (2016) Failure of intraoperative monitoring to detect postoperative neurologic deficits: a 25-year experience in 12,375 spinal surgeries. Spine 41(17):1387\u20131393. https:\/\/doi.org\/10.1097\/BRS.0000000000001531","journal-title":"Spine"},{"issue":"4","key":"1154_CR10","doi-asserted-by":"publisher","first-page":"E8","DOI":"10.3171\/2017.7.FOCUS17364","volume":"43","author":"M Zuccaro","year":"2017","unstructured":"Zuccaro M, Zuccaro J, Samdani AF, Pahys JM, Hwang SW (2017) Intraoperative neuromonitoring alerts in a pediatric deformity center. Neurosurg Focus 43(4):E8. https:\/\/doi.org\/10.3171\/2017.7.FOCUS17364","journal-title":"Neurosurg Focus"},{"issue":"2","key":"1154_CR11","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1097\/ALN.0000000000004744","volume":"140","author":"LM Carabini","year":"2024","unstructured":"Carabini LM, Koski TR, Bebawy JF (2024) Perioperative management for complex spine fusion surgery. Anesthesiology 140(2):293\u2013303. https:\/\/doi.org\/10.1097\/ALN.0000000000004744","journal-title":"Anesthesiology"},{"issue":"4","key":"1154_CR12","doi-asserted-by":"publisher","first-page":"736","DOI":"10.1016\/s1388-2457(99)00317-x","volume":"111","author":"JR Toleikis","year":"2000","unstructured":"Toleikis JR, Skelly JP, Carlvin AO, Burkus JK (2000) Spinally elicited peripheral nerve responses are sensory rather than motor. Clin Neurophysiol 111(4):736\u2013742. https:\/\/doi.org\/10.1016\/s1388-2457(99)00317-x","journal-title":"Clin Neurophysiol"},{"issue":"11","key":"1154_CR13","doi-asserted-by":"publisher","first-page":"2143","DOI":"10.1016\/j.spinee.2024.06.572","volume":"24","author":"S Rajasekaran","year":"2024","unstructured":"Rajasekaran S, Ramachandran K, Thippeswamy PB, Balachandran GS, Anand KSSV, Shetty AP, Kanna RM (2024) Risk predictive score and cord morphology classification for intraoperative neuromonitoring alerts in kyphosis surgery. Spine J 24(11):2143\u20132153. https:\/\/doi.org\/10.1016\/j.spinee.2024.06.572. (Epub 2024 Jul 18. PMID: 39032610)","journal-title":"Spine J"}],"container-title":["Spine Deformity"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s43390-025-01154-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s43390-025-01154-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s43390-025-01154-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T17:52:08Z","timestamp":1763661128000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s43390-025-01154-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,11]]},"references-count":13,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025,11]]}},"alternative-id":["1154"],"URL":"https:\/\/doi.org\/10.1007\/s43390-025-01154-4","relation":{},"ISSN":["2212-134X","2212-1358"],"issn-type":[{"value":"2212-134X","type":"print"},{"value":"2212-1358","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,11]]},"assertion":[{"value":"11 February 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 July 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 August 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"No conflicts exist for any of the authors pertaining to the submitted work.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"No human subjects or animals participated therefore no informed consent was obtained. IRB approval was obtained from Washington University Institutional Review Board, IRB # 202403040.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}