{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T13:08:46Z","timestamp":1788872926341,"version":"build-2803163510"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T00:00:00Z","timestamp":1777334400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T00:00:00Z","timestamp":1777334400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Spine Deform"],"published-print":{"date-parts":[[2026,9]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To evaluate the neurologic safety and economic implications of performing traditional growing rod (TGR) lengthening procedures for early-onset scoliosis (EOS) without intraoperative neuromonitoring (IONM). Although IONM is widely adopted for deformity correction, its necessity during routine distraction lengthening procedures remains uncertain.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A retrospective cohort study was conducted of pediatric EOS patients (&lt;\u200918\u00a0years) who underwent TGR lengthening procedures between 2000 and 2020 at a single tertiary children\u2019s hospital. Inclusion required documented neurologic assessments and radiographic follow-up within 6\u00a0months of the index surgery. Patients with alternative fixation strategies or incomplete records were excluded. Demographic, operative, and neurologic outcome data were collected from institutional registries and chart review. The use or omission of IONM was confirmed. Procedural cost estimates for IONM were obtained from institutional billing records using CPT-based rates. Descriptive statistics were calculated in SPSS v29.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Fifty-nine patients (279 TGR lengthening procedures) met inclusion criteria. The mean age at index surgery was 6.6\u2009\u00b1\u20092.3\u00a0years. IONM was not used for any TGR lengthening procedures during this period. No immediate postoperative or delayed neurologic deficits were identified during the 20-year study period. The mean procedure duration was 45.2\u2009\u00b1\u20096.1\u00a0min. The estimated institutional cost of IONM per 45-min TGR lengthening was $6,500, representing an approximate cumulative savings of $1.81 million across all procedures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Over two decades, no neurologic complications occurred in TGR lengthening procedures performed without IONM, supporting the safety of omitting routine monitoring. Selective IONM use may yield substantial economic benefit without compromising patient outcomes.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s43390-026-01376-0","type":"journal-article","created":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T04:59:19Z","timestamp":1777352359000},"page":"1915-1920","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Traditional growing rod lengthening without intraoperative neuromonitoring: a 20-year institutional analysis demonstrating neurologic safety and cost savings"],"prefix":"10.1007","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-7258-4980","authenticated-orcid":false,"given":"Alex","family":"R. La Poche","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tyler D.","family":"Metcalf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-5835-6806","authenticated-orcid":false,"given":"Austin","family":"V. Montgomery","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5431-6663","authenticated-orcid":false,"given":"Gregory A.","family":"Mencio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5768-6715","authenticated-orcid":false,"given":"Jeffrey E.","family":"Martus","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4450-4502","authenticated-orcid":false,"given":"Craig R.","family":"Louer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,4,28]]},"reference":[{"key":"1376_CR1","doi-asserted-by":"publisher","DOI":"10.1097\/BPO.0b013e3180333eea","author":"GH Thompson","year":"2007","unstructured":"Thompson GH, Akbarnia BA, Campbell RM (2007) Growing rod techniques in early-onset scoliosis. J of Pediatr Orthop. https:\/\/doi.org\/10.1097\/BPO.0b013e3180333eea","journal-title":"J of Pediatr Orthop"},{"key":"1376_CR2","doi-asserted-by":"publisher","DOI":"10.4103\/isj.isj_73_22","author":"A Srivastava","year":"2023","unstructured":"Srivastava A, Gupta A, Hanasoge V, Jayaswal A (2023) Complications of growing rod technique for early onset scoliosis. Indian Spine J. https:\/\/doi.org\/10.4103\/isj.isj_73_22","journal-title":"Indian Spine J"},{"key":"1376_CR3","doi-asserted-by":"publisher","DOI":"10.1055\/a-1009-4971","author":"E Shiban","year":"2019","unstructured":"Shiban E, Ille S, Meyer B (2019) Intraoperative neuromonitoring in spine surgery. Klin Neurophysiol. https:\/\/doi.org\/10.1055\/a-1009-4971","journal-title":"Klin Neurophysiol"},{"key":"1376_CR4","doi-asserted-by":"publisher","DOI":"10.3171\/2017.7.FOCUS17364","author":"M Zuccaro","year":"2017","unstructured":"Zuccaro M, Zuccaro J, Samdani AF, Pahys JM, Hwang SW (2017) Intraoperative neuromonitoring alerts in a pediatric deformity center. Neurosurg Focus. https:\/\/doi.org\/10.3171\/2017.7.FOCUS17364","journal-title":"Neurosurg Focus"},{"key":"1376_CR5","doi-asserted-by":"publisher","DOI":"10.1007\/978-981-99-3017-3_47","volume-title":"Paediatric scoliosis","author":"S Gopinath","year":"2023","unstructured":"Gopinath S, Gohel A, Shah R (2023) Intraoperative neuromonitoring in pediatric scoliosis surgery. Paediatric scoliosis. Springer Nature, Singapore. https:\/\/doi.org\/10.1007\/978-981-99-3017-3_47"},{"issue":"1","key":"1376_CR6","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1097\/BRS.0000000000001658","volume":"42","author":"BA Sanders","year":"2017","unstructured":"Sanders BA, Andras LM, Lehman AM et al (2017) Dermal discolorations and burns at neuromonitoring electrodes in pediatric spine surgery. Spine 42(1):20\u201324. https:\/\/doi.org\/10.1097\/BRS.0000000000001658","journal-title":"Spine"},{"key":"1376_CR7","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1016\/j.wneu.2018.01.192","volume":"112","author":"IM Eli","year":"2018","unstructured":"Eli IM, Gamboa NT, Guan J, Taussky P (2018) Acute compartment syndrome as a complication of the use of intraoperative neuromonitoring needle electrodes. World Neurosurg 112:247\u2013249. https:\/\/doi.org\/10.1016\/j.wneu.2018.01.192","journal-title":"World Neurosurg"},{"issue":"1","key":"1376_CR8","doi-asserted-by":"publisher","first-page":"e468","DOI":"10.7759\/cureus.468","volume":"8","author":"A Shoakazemi","year":"2016","unstructured":"Shoakazemi A, Moisi M, Tubbs RS et al (2016) Necrotizing fasciitis: a life-threatening complication of intraoperative electromyography. Cureus 8(1):e468. https:\/\/doi.org\/10.7759\/cureus.468","journal-title":"Cureus"},{"issue":"23","key":"1376_CR9","doi-asserted-by":"publisher","first-page":"1636","DOI":"10.1097\/brs.0000000000005061","volume":"49","author":"WH Truong","year":"2024","unstructured":"Truong WH, Matsumoto H, Brooks JT, Guillaume TJ, Andras LM, Cahill PJ et al (2024) Development of consensus-based best practice guidelines for the perioperative and postoperative care of pediatric patients with spinal deformity and programmable implanted devices. Spine 49(23):1636\u20131644. https:\/\/doi.org\/10.1097\/brs.0000000000005061","journal-title":"Spine"},{"key":"1376_CR10","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e3181afe869","author":"WN Sankar","year":"2009","unstructured":"Sankar WN, Skaggs DL, Emans JB et al (2009) Neurologic risk in growing rod spine surgery in early onset scoliosis: is neuromonitoring necessary for all cases? Spine. https:\/\/doi.org\/10.1097\/BRS.0b013e3181afe869","journal-title":"Spine"},{"key":"1376_CR11","doi-asserted-by":"publisher","DOI":"10.1016\/j.jspd.2014.05.003","author":"MG Vitale","year":"2014","unstructured":"Vitale MG, Skaggs DL, Pace GI et al (2014) Best practices in intraoperative neuromonitoring in spine deformity surgery: development of an intraoperative checklist to optimize response. Spine Deform. https:\/\/doi.org\/10.1016\/j.jspd.2014.05.003","journal-title":"Spine Deform"},{"key":"1376_CR12","doi-asserted-by":"publisher","DOI":"10.2106\/jbjs.i.01471","author":"S Bess","year":"2010","unstructured":"Bess S, Akbarnia BA, Thompson GH et al (2010) Complications of growing-rod treatment for early-onset scoliosis. J Bone Joint Surg-Am. https:\/\/doi.org\/10.2106\/jbjs.i.01471","journal-title":"J Bone Joint Surg-Am"},{"key":"1376_CR13","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.G.00202","author":"DL Skaggs","year":"2009","unstructured":"Skaggs DL, Choi PD, Rice C et al (2009) Efficacy of intraoperative neurologic monitoring in surgery involving a vertical expandable prosthetic titanium rib for early-onset spinal deformity. J Bone Joint Surg. https:\/\/doi.org\/10.2106\/JBJS.G.00202","journal-title":"J Bone Joint Surg"},{"key":"1376_CR14","doi-asserted-by":"publisher","DOI":"10.1097\/BPO.0000000000000976","author":"J Lagreca","year":"2017","unstructured":"Lagreca J, Flynn T, Cahill PJ et al (2017) Patients without intraoperative neuromonitoring (IONM) alerts during VEPTR implantation did not sustain neurological injury during subsequent routine expansions: a retrospective multicenter cohort study. J Pediatr Orthop. https:\/\/doi.org\/10.1097\/BPO.0000000000000976","journal-title":"J Pediatr Orthop"},{"key":"1376_CR15","doi-asserted-by":"publisher","DOI":"10.1016\/j.jspd.2014.08.003","author":"LE Gauthier","year":"2014","unstructured":"Gauthier LE, Mandourah Y, Soroceanu A, McIntosh AL, Flynn JM, El-Hawary R (2014) Perioperative neurologic injury associated with rib-based distraction surgery. Spine Deform. https:\/\/doi.org\/10.1016\/j.jspd.2014.08.003","journal-title":"Spine Deform"},{"key":"1376_CR16","doi-asserted-by":"publisher","DOI":"10.1007\/s43390-020-00163-9","author":"B Garg","year":"2020","unstructured":"Garg B, Mohapatra S, Mehta N (2020) Is routine intraoperative neuromonitoring necessary in growing rod lengthening procedures? A retrospective, observational study. Spine Deform. https:\/\/doi.org\/10.1007\/s43390-020-00163-9","journal-title":"Spine Deform"},{"key":"1376_CR17","doi-asserted-by":"publisher","DOI":"10.1007\/s12178-016-9372-5","author":"RF Murphy","year":"2016","unstructured":"Murphy RF, Mooney JF (2016) Complications following spine fusion for adolescent idiopathic scoliosis. Curr Rev Musculoskelet Med. https:\/\/doi.org\/10.1007\/s12178-016-9372-5","journal-title":"Curr Rev Musculoskelet Med"},{"key":"1376_CR18","doi-asserted-by":"publisher","DOI":"10.1016\/j.xnsj.2023.100206","author":"JD Ament","year":"2023","unstructured":"Ament JD, Leon A, Kim KD, Johnson JP, Vokshoor A (2023) Intraoperative neuromonitoring in spine surgery: large database analysis of cost-effectiveness. North Am Spine Soc J. https:\/\/doi.org\/10.1016\/j.xnsj.2023.100206","journal-title":"North Am Spine Soc J"},{"issue":"10","key":"1376_CR19","doi-asserted-by":"publisher","first-page":"3301","DOI":"10.1007\/s00586-016-4566-5","volume":"25","author":"A Jayaswal","year":"2016","unstructured":"Jayaswal A, Kandwal P, Goswami A, Vijayaraghavan G, Jariyal A, Upendra BN et al (2016) Early onset scoliosis with intraspinal anomalies: management with growing rod. Eur Spine J 25(10):3301\u20133307. https:\/\/doi.org\/10.1007\/s00586-016-4566-5","journal-title":"Eur Spine J"}],"container-title":["Spine Deformity"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s43390-026-01376-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s43390-026-01376-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s43390-026-01376-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T12:31:38Z","timestamp":1788870698000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s43390-026-01376-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,28]]},"references-count":19,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,9]]}},"alternative-id":["1376"],"URL":"https:\/\/doi.org\/10.1007\/s43390-026-01376-0","relation":{},"ISSN":["2212-134X","2212-1358"],"issn-type":[{"value":"2212-134X","type":"print"},{"value":"2212-1358","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,28]]},"assertion":[{"value":"19 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 April 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Craig Louer reports participation in the Speaker\u2019s Bureau for Johnson & Johnson Med Tech, Globus Medical, Inc., and Highridge Medical; consultancy with Orthopediatrics, Inc.; royalties from Nsite Medical, Inc.; research support from Globus Medical, Inc. (institutional support for research personnel); and service on the Board of Directors of the Pediatric Orthopaedic Society of North America (POSNA). Gregory Mencio and Jeff Martus each report research support from Globus Medical, Inc. (institutional support for research personnel). Authors not listed have no interests to disclose.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Vanderbilt University Medical Center Institutional Review Board (IRB# #211899 Understanding outcomes following operative and non-operative treatment for pediatric spinal deformity patients).","order":2,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}}]}}