{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T04:45:45Z","timestamp":1791780345201,"version":"4.3.4"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T00:00:00Z","timestamp":1783641600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T00:00:00Z","timestamp":1783641600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["JOIO"],"published-print":{"date-parts":[[2026,10]]},"DOI":"10.1007\/s43465-026-01887-y","type":"journal-article","created":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T03:41:23Z","timestamp":1783654883000},"page":"2822-2830","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Radiological and Functional Outcomes of Joshi External Stabilization System (JESS) in Proximal Tibia Fractures: A\u00a0Case Series"],"prefix":"10.1007","volume":"60","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3582-5542","authenticated-orcid":false,"given":"Siddhartha","family":"Sinha","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0469-4807","authenticated-orcid":false,"given":"Sandeep","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6224-3636","authenticated-orcid":false,"given":"Arvind","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-4443-2015","authenticated-orcid":false,"given":"Saket","family":"Bandil","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5227-2169","authenticated-orcid":false,"given":"Owais Ahmed","family":"Qureshi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-7916-7363","authenticated-orcid":false,"given":"Javed","family":"Jameel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,10]]},"reference":[{"issue":"2","key":"1887_CR1","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1016\/j.ocl.2013.11.003","volume":"45","author":"DW Lowenberg","year":"2014","unstructured":"Lowenberg, D. W., Githens, M., & Boone, C. (2014). Principles of tibial fracture management with circular external fixation. Orthopedic Clinics of North America, 45(2), 191\u2013206. https:\/\/doi.org\/10.1016\/j.ocl.2013.11.003","journal-title":"Orthopedic Clinics of North America"},{"key":"1887_CR2","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2474-14-11","author":"T Ramos","year":"2013","unstructured":"Ramos, T., Ekholm, C., Eriksson, B. I., Karlsson, J., & Nistor, L. (2013). The Ilizarov external fixator-a useful alternative for the treatment of proximal tibial fractures A prospective observational study of 30 consecutive patients. BMC Musculoskeletal Disorders. https:\/\/doi.org\/10.1186\/1471-2474-14-11","journal-title":"BMC Musculoskeletal Disorders"},{"issue":"1","key":"1887_CR3","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/j.jcot.2015.01.037","volume":"6","author":"V Jangira","year":"2015","unstructured":"Jangira, V., Jain, V., Kalra, M., Jindal, R., & Garg, S. (2015). Treatment of displaced intra-articular calcaneal fracture: A combined minimally invasive approach using transarticular external fixator (JESS) with or without internal fixation. Journal of Clinical Orthopaedics and Trauma, 6(1), 67. https:\/\/doi.org\/10.1016\/j.jcot.2015.01.037","journal-title":"Journal of Clinical Orthopaedics and Trauma"},{"issue":"5","key":"1887_CR4","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1007\/s43465-025-01374-w","volume":"59","author":"S Sinha","year":"2025","unstructured":"Sinha, S., Kumar, S., Kumar, A., Aggarwal, N., Bandil, S., Qureshi, O. A., et al. (2025). Radiological and functional outcomes of Joshi external stabilization system (JESS) in proximal humerus fractures: A retrospective review. Indian Journal of Orthopaedics, 59(5), 611\u2013619. https:\/\/doi.org\/10.1007\/s43465-025-01374-w","journal-title":"Indian Journal of Orthopaedics"},{"issue":"6","key":"1887_CR5","doi-asserted-by":"publisher","first-page":"326","DOI":"10.4103\/0019-5413.93679","volume":"18","author":"AK Gupta","year":"2015","unstructured":"Gupta, A. K., Sapra, R., Kumar, R., Gupta, S. P., Kaushik, D., Gaba, S., et al. (2015). Role of Joshi\u2019s external stabilization system with percutaneous screw fixation in high-energy tibial condylar fractures associated with severe soft tissue injuries. Chinese Journal of Traumatology, 18(6), 326\u2013331. https:\/\/doi.org\/10.4103\/0019-5413.93679","journal-title":"Chinese Journal of Traumatology"},{"issue":"2","key":"1887_CR6","doi-asserted-by":"publisher","first-page":"65","DOI":"10.13107\/jocr.2023.v13.i02.3560","volume":"13","author":"G Thambusamy","year":"2023","unstructured":"Thambusamy, G., Subramanian, K., Mathialagan, S., Chockalingam, B., & Muthu, S. (2023). 6-Pin Technique Joshi External Stabilization System Fixation for Proximal Humerus Fractures\u2013A Case Series. Journal of Orthopaedic Case Reports, 13(2), 65. https:\/\/doi.org\/10.13107\/jocr.2023.v13.i02.3560","journal-title":"Journal of Orthopaedic Case Reports"},{"issue":"6","key":"1887_CR7","doi-asserted-by":"publisher","first-page":"579","DOI":"10.1097\/BPB.0000000000000594","volume":"28","author":"A Ajmera","year":"2019","unstructured":"Ajmera, A., Jain, S., Singh, A. K., Solanki, M., & Verma, A. (2019). Simultaneous lateral column shortening along with differential distraction by Joshi\u2019s external stabilization system for rigid neglected clubfoot correction. Journal of Pediatric Orthopaedics. Part B, 28(6), 579\u2013585. https:\/\/doi.org\/10.1097\/BPB.0000000000000594","journal-title":"Journal of Pediatric Orthopaedics. Part B"},{"issue":"1","key":"1887_CR8","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.fas.2014.08.007","volume":"21","author":"LK Lohia","year":"2015","unstructured":"Lohia, L. K., Meena, S., & Kanojia, R. K. (2015). Comparative study of complete subtalar release and Joshi\u2019s external stabilization system in the management of neglected and resistant idiopathic clubfoot. Journal of Foot and Ankle Surgery, 21(1), 16\u201321. https:\/\/doi.org\/10.1016\/j.fas.2014.08.007","journal-title":"Journal of Foot and Ankle Surgery"},{"issue":"1","key":"1887_CR9","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1177\/230949901101900117","volume":"19","author":"R Kumar","year":"2011","unstructured":"Kumar, R., Gupta, A., Sharma, V., & Mishra, S. (2011). Strength of the Joshi external stabilising system. Journal of Orthopaedic Surgery, 19(1), 72\u201375.","journal-title":"Journal of Orthopaedic Surgery"},{"issue":"1","key":"1887_CR10","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1177\/230949901101900117","volume":"19","author":"R Kumar","year":"2011","unstructured":"Kumar, R., Gupta, R., & Mishra, S. (2011). Experimental Testing of Joshi\u2019s External Stabilizing System (JESS) under Axial Compression. Journal of Orthopaedic Surgery, 19(1), 72\u201375. https:\/\/doi.org\/10.1177\/230949901101900117","journal-title":"Journal of Orthopaedic Surgery"},{"issue":"3","key":"1887_CR11","doi-asserted-by":"publisher","first-page":"194","DOI":"10.13107\/jocr.2025.v15.i03.5386","volume":"15","author":"C Chaugule","year":"2025","unstructured":"Chaugule, C., Date, J., Tanpure, S., Karangutkar, A., Sonawane, A., & Jethe, B. (2025). Innovative Use of Joshi\u2019s External Stabilization System for Tibial Fractures Complicated by Skin and Soft-Tissue Issues: A Case Series. Journal of Orthopaedic Case Reports, 15(3), 194. https:\/\/doi.org\/10.13107\/jocr.2025.v15.i03.5386","journal-title":"Journal of Orthopaedic Case Reports"},{"issue":"13","key":"1887_CR12","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1097\/00003086-198911000-00004","volume":"248","author":"I Jn","year":"1989","unstructured":"Jn, I., Dorr, lD., Scott, R. D., & Scott, W. N. (1989). Rationale of the Knee Society clinical rating system. Clinical Orthopaedics., 248(13), 12. https:\/\/doi.org\/10.1097\/00003086-198911000-00004","journal-title":"Clinical Orthopaedics."},{"issue":"3","key":"1887_CR13","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1007\/s00590-014-1528-7","volume":"25","author":"L Yu","year":"2015","unstructured":"Yu, L., & Fenglin, Z. (2015). High-energy tibial plateau fractures: External fixation versus plate fixation. European Journal of Orthopaedic Surgery & Traumatology, 25(3), 411\u2013423. https:\/\/doi.org\/10.1007\/s00590-014-1528-7","journal-title":"European Journal of Orthopaedic Surgery & Traumatology"},{"key":"1887_CR14","doi-asserted-by":"publisher","unstructured":"Society. COT (2006). Open Reduction and Internal Fixation Compared with Circular Fixator Application for Bicondylar Tibial Plateau Fractures: Results of a Multicenter, Prospective, Randomized Clinical Trial. J Bone Joint Surg Am. 88(12): 2613\u201323. https:\/\/doi.org\/10.2106\/JBJS.E.01416","DOI":"10.2106\/JBJS.E.01416"},{"issue":"4","key":"1887_CR15","doi-asserted-by":"publisher","first-page":"3177","DOI":"10.1007\/s00068-021-01868-w","volume":"48","author":"Z Xue","year":"2022","unstructured":"Xue, Z., Lang, J., Chen, L., Yuan, J., & Zhou, K. (2022). Risk factors of hospitalization costs and length of stay for tibial plateau fractures. European Journal of Orthopaedic Surgery & Traumatology, 48(4), 3177\u20133183. https:\/\/doi.org\/10.1007\/s00068-021-01868-w","journal-title":"European Journal of Orthopaedic Surgery & Traumatology"},{"issue":"5","key":"1887_CR16","doi-asserted-by":"publisher","first-page":"444","DOI":"10.5152\/j.aott.2021.20350","volume":"55","author":"SK Tripathy","year":"2021","unstructured":"Tripathy, S. K., Varghese, P., Panigrahi, S., Panda, B. B., Srinivasan, A., & Sen, R. K. (2021). External fixation versus open reduction and internal fixation in the treatment of complex tibial plateau fractures: A systematic review and meta-analysis. Acta Orthopaedica et Traumatologica Turcica, 55(5), 444. https:\/\/doi.org\/10.5152\/j.aott.2021.20350","journal-title":"Acta Orthopaedica et Traumatologica Turcica"},{"issue":"2","key":"1887_CR17","doi-asserted-by":"publisher","first-page":"105","DOI":"10.5005\/jp-journals-10080-1557","volume":"17","author":"AS Naja","year":"2022","unstructured":"Naja, A. S., Bouji, N., Eddine, M. N., Alfarii, H., Reindl, R., Tfayli, Y., et al. (2022). A meta-analysis comparing external fixation against open reduction and internal fixation for the management of tibial plateau fractures. Strategies in Trauma and Limb Reconstruction, 17(2), 105. https:\/\/doi.org\/10.5005\/jp-journals-10080-1557","journal-title":"Strategies in Trauma and Limb Reconstruction"}],"container-title":["Indian Journal of Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s43465-026-01887-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s43465-026-01887-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s43465-026-01887-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T04:04:09Z","timestamp":1791777849000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s43465-026-01887-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,10]]},"references-count":17,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2026,10]]}},"alternative-id":["1887"],"URL":"https:\/\/doi.org\/10.1007\/s43465-026-01887-y","relation":{},"ISSN":["0019-5413","1998-3727"],"issn-type":[{"value":"0019-5413","type":"print"},{"value":"1998-3727","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,10]]},"assertion":[{"value":"30 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors do not have any conflicts of interest to declare.","order":1,"name":"Ethics","label":"Conflict of Interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Consent obtained from the institutional ethics committee (HIMSR\/IEC\/00184\/2024).","order":2,"name":"Ethics","label":"Ethical Approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Written, informed consent was obtained from all subjects involved in the study.","order":3,"name":"Ethics","label":"Informed Consent","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Results not attached as suggested by editor\/reviewer.","order":4,"name":"Ethics","label":"Plagiarism Check","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Artificial intelligence was not used in any stage for the purpose of preparation of the manuscript.","order":5,"name":"Ethics","label":"The Use of Artificial Intelligence","group":{"name":"EthicsHeading","label":"Declarations"}}]}}