{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T10:05:52Z","timestamp":1779357952742,"version":"3.51.4"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T00:00:00Z","timestamp":1775001600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,4,13]],"date-time":"2026-04-13T00:00:00Z","timestamp":1776038400000},"content-version":"vor","delay-in-days":12,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Saudi Dent. J."],"published-print":{"date-parts":[[2026,4]]},"DOI":"10.1007\/s44445-026-00150-2","type":"journal-article","created":{"date-parts":[[2026,4,13]],"date-time":"2026-04-13T05:10:21Z","timestamp":1776057021000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparative evaluation of compressive strength of CAD-CAM polyetheretherketone and indirect composite Class II inlays: an in vitro study"],"prefix":"10.1007","volume":"38","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8322-6878","authenticated-orcid":false,"given":"Nidhi","family":"Sharma","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Siddhant","family":"Mahajan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9759-3671","authenticated-orcid":false,"given":"Ish Kumar","family":"Sharma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0848-6984","authenticated-orcid":false,"given":"Neha","family":"Verma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6998-5683","authenticated-orcid":false,"given":"Diksha","family":"Yadav","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-3475-9870","authenticated-orcid":false,"given":"Nikita","family":"Poonia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,4,13]]},"reference":[{"issue":"2","key":"150_CR1","doi-asserted-by":"publisher","first-page":"60","DOI":"10.5577\/intdentres.2020.vol10.no2.6","volume":"10","author":"C Akay","year":"2020","unstructured":"Akay C, Ers\u00f6z MB (2020) Peek in dentistry: properties and application areas. Int Dent Res 10(2):60\u201365. https:\/\/doi.org\/10.5577\/intdentres.2020.vol10.no2.6","journal-title":"Int Dent Res"},{"issue":"2","key":"150_CR2","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1177\/09506608251314251","volume":"70","author":"AY Alqutaibi","year":"2025","unstructured":"Alqutaibi AY, Alghauli MA, Algabri RS, Hamadallah HH, Aboalrejal AN, Zafar MS, Fareed MA (2025) Applications, modifications, and manufacturing of polyetheretherketone (PEEK) in dental implantology: a comprehensive critical review. Int Mater Rev 70(2):103\u2013136","journal-title":"Int Mater Rev"},{"issue":"1","key":"150_CR3","doi-asserted-by":"publisher","first-page":"5","DOI":"10.25122\/jml-2019-0003","volume":"12","author":"L Bathala","year":"2019","unstructured":"Bathala L, Majeti V, Rachuri N, Singh N, Gedela S (2019) The role of polyether ether ketone (PEEK) in dentistry: a review. J Med Life 12(1):5\u20139. https:\/\/doi.org\/10.25122\/jml-2019-0003","journal-title":"J Med Life"},{"issue":"S1","key":"150_CR4","doi-asserted-by":"publisher","first-page":"S65","DOI":"10.1111\/jerd.12136","volume":"27","author":"T Bezgin","year":"2015","unstructured":"Bezgin T, \u00d6zer L, Tulga \u00d6z F, \u00d6zkan P (2015) Effect of toothbrushing on color changes of esthetic restorative materials. J Esthet Restor Dent 27(S1):S65\u2013S73","journal-title":"J Esthet Restor Dent"},{"issue":"1","key":"150_CR5","doi-asserted-by":"publisher","first-page":"37","DOI":"10.2341\/07-27","volume":"33","author":"FH Coelho-de-Souza","year":"2008","unstructured":"Coelho-de-Souza FH, Camacho GB, Demarco FF, Powers JM (2008) Fracture resistance and gap formation of MOD restorations: influence of restorative technique, bevel preparation and water storage. Oper Dent 33(1):37\u201343. https:\/\/doi.org\/10.2341\/07-27","journal-title":"Oper Dent"},{"key":"150_CR6","volume-title":"Thermoplastic aromatic polymer composites: Structure, processing and properties of carbon fibre reinforced polyetheretherketone and related materials","author":"FN Cogswell","year":"2013","unstructured":"Cogswell FN (2013) Thermoplastic aromatic polymer composites: Structure, processing and properties of carbon fibre reinforced polyetheretherketone and related materials. Elsevier"},{"issue":"12","key":"150_CR8","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.1016\/j.dental.2023.10.009","volume":"39","author":"U Josic","year":"2023","unstructured":"Josic U, D\u2019Alessandro C, Miletic V, Maravic T, Mazzitelli C, Jacimovic J, Sorrentino R, Zarone F, Mancuso E, Delgado AH, Breschi L (2023) Clinical longevity of direct and indirect posterior resin composite restorations: an updated systematic review and meta-analysis. Dent Mater 39(12):1085\u20131094. https:\/\/doi.org\/10.1016\/j.dental.2023.10.009","journal-title":"Dent Mater"},{"issue":"32","key":"150_CR9","doi-asserted-by":"publisher","first-page":"4845","DOI":"10.1016\/j.biomaterials.2007.07.013","volume":"28","author":"SM Kurtz","year":"2007","unstructured":"Kurtz SM, Devine JN (2007) PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials 28(32):4845\u20134869. https:\/\/doi.org\/10.1016\/j.biomaterials.2007.07.013","journal-title":"Biomaterials"},{"issue":"S1","key":"150_CR10","doi-asserted-by":"publisher","first-page":"S40","DOI":"10.1111\/jerd.12166","volume":"28","author":"NC Lawson","year":"2016","unstructured":"Lawson NC, Burgess JO (2016) Gloss and stain resistance of ceramic\u2013polymer CAD\/CAM restorative blocks. J Esthet Restor Dent 28(S1):S40\u2013S45. https:\/\/doi.org\/10.1111\/jerd.12166","journal-title":"J Esthet Restor Dent"},{"issue":"3","key":"150_CR11","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1016\/j.prosdent.2015.09.004","volume":"115","author":"A Liebermann","year":"2016","unstructured":"Liebermann A, Wimmer T, Schmidlin PR, Scherer H, L\u00f6ffler P, Roos M, Stawarczyk B (2016) Physicomechanical characterization of polyetheretherketone and esthetic dental CAD\/CAM polymers after aging in different storage media. J Prosthet Dent 115(3):321\u2013328. https:\/\/doi.org\/10.1016\/j.prosdent.2015.09.004","journal-title":"J Prosthet Dent"},{"issue":"23","key":"150_CR12","doi-asserted-by":"publisher","first-page":"5109","DOI":"10.3390\/polym14235109","volume":"14","author":"LM Maloo","year":"2022","unstructured":"Maloo LM, Chawhan R, Vairagade S et al (2022) A sneak peek toward polyaryletherketone (PAEK) polymer. Polymers 14(23):5109. https:\/\/doi.org\/10.3390\/polym14235109","journal-title":"Polymers"},{"key":"150_CR13","doi-asserted-by":"publisher","first-page":"3457","DOI":"10.1007\/s00784-020-03216-5","volume":"24","author":"A Prechtel","year":"2020","unstructured":"Prechtel A, Stawarczyk B, Hickel R, Edelhoff D, Reymus M (2020) Fracture load of 3D printed PEEK inlays compared with milled ones, direct resin composite fillings, and sound teeth. Clin Oral Invest 24:3457\u20133466. https:\/\/doi.org\/10.1007\/s00784-020-03216-5","journal-title":"Clin Oral Invest"},{"issue":"2","key":"150_CR16","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1080\/15583724.2012.668151","volume":"52","author":"D Shukla","year":"2012","unstructured":"Shukla D, Negi YS, Uppadhyaya JS, Kumar V (2012) Synthesis and modification of poly(ether ether ketone) and their properties: a review. Polym Rev 52(2):189\u2013228. https:\/\/doi.org\/10.1080\/15583724.2012.668151","journal-title":"Polym Rev"},{"issue":"1","key":"150_CR17","doi-asserted-by":"publisher","DOI":"10.3390\/polym17010080","volume":"17","author":"N Taymour","year":"2024","unstructured":"Taymour N, Abd El-Fattah A, Kandil S, Fahmy AE, Al-Qahtani NH, Khaled A, Al-Dulaijan YA, Gepreel MA (2024) Revolutionizing dental polymers: the versatility and future potential of polyetheretherketone in restorative dentistry. Polymers 17(1):80. https:\/\/doi.org\/10.3390\/polym17010080","journal-title":"Polymers"},{"key":"150_CR18","doi-asserted-by":"publisher","unstructured":"Verma A, Tiwary CS, Bhattacharya J (2022) Green Graphene-Based Anticorrosive Coating for Carbon Steel in Marine Environment. InInternational Conference on Advances in Materials Processing: Challenges and Opportunities (pp. 161-166). Singapore: Springer Nature Singapore. https:\/\/doi.org\/10.1007\/978-981-99-1971-0_24","DOI":"10.1007\/978-981-99-1971-0_24"}],"container-title":["The Saudi Dental Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s44445-026-00150-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s44445-026-00150-2","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s44445-026-00150-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T09:11:01Z","timestamp":1779354661000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s44445-026-00150-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4]]},"references-count":15,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026,4]]}},"alternative-id":["150"],"URL":"https:\/\/doi.org\/10.1007\/s44445-026-00150-2","relation":{},"ISSN":["1013-9052","2524-1702"],"issn-type":[{"value":"1013-9052","type":"print"},{"value":"2524-1702","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4]]},"assertion":[{"value":"14 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This was an in vitro study. Ethical approval was not required as no human participants or animals were involved.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics statement"}},{"value":"The key strength of the study is that it is clinically realistic, where every restorative material was manufactured through its conventional and most widely accepted technique, that is, CAD-CAM milling of PEEK and indirect laboratory production of composite resin. In this manner, both materials can be tested in their optimum mechanical potential to optimize the clinical significance and validity of the results on comparative compressive strength.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Strength"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"Not applicable.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no known competing financial interests or personal relationships that could have influenced the work reported in this paper.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"48"}}