{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,11]],"date-time":"2024-09-11T11:04:28Z","timestamp":1726052668549},"publisher-location":"Cham","reference-count":24,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783030320393"},{"type":"electronic","value":"9783030320409"}],"license":[{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019]]},"DOI":"10.1007\/978-3-030-32040-9_61","type":"book-chapter","created":{"date-parts":[[2019,9,27]],"date-time":"2019-09-27T06:03:18Z","timestamp":1569564198000},"page":"606-614","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Thermoplastic Materials for Infrastructures in Prosthodontic Rehabilitation: A Review"],"prefix":"10.1007","author":[{"given":"Margarida","family":"Sampaio-Fernandes","sequence":"first","affiliation":[]},{"given":"Sandra","family":"Campos","sequence":"additional","affiliation":[]},{"given":"Jo\u00e3o","family":"Galhardo","sequence":"additional","affiliation":[]},{"given":"Susana","family":"Oliveira","sequence":"additional","affiliation":[]},{"given":"Jos\u00e9 Carlos","family":"Reis-Campos","sequence":"additional","affiliation":[]},{"given":"Maria Helena","family":"Figueiral","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2019,9,28]]},"reference":[{"issue":"3","key":"61_CR1","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1016\/j.prosdent.2017.01.008","volume":"118","author":"SD Campbell","year":"2017","unstructured":"Campbell, S.D., Cooper, L., Craddock, H., Hyde, T.P., Nattress, B., Pavitt, S.H., et al.: Removable partial dentures: the clinical need for innovation. J. Prosthet. Dent. 118(3), 273\u2013280 (2017)","journal-title":"J. Prosthet. Dent."},{"issue":"4","key":"61_CR2","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1016\/j.rpemd.2016.10.001","volume":"57","author":"B Rosca","year":"2016","unstructured":"Rosca, B., Ramalho, S., Sampaio-Fernandes, J.C., Portugal, J.: Reparability of two different CAD\/CAM polymer materials using a light-cured composite and universal adhesives. Revista Portuguesa de Estomatologia, Medicina Dent\u00e1ria e Cirurgia Maxilofacial 57(4), 189\u2013196 (2016)","journal-title":"Revista Portuguesa de Estomatologia, Medicina Dent\u00e1ria e Cirurgia Maxilofacial"},{"issue":"3","key":"61_CR3","doi-asserted-by":"publisher","first-page":"381","DOI":"10.4012\/dmj.2012-284","volume":"32","author":"H Osada","year":"2013","unstructured":"Osada, H., Shimpo, H., Hayakawa, T., Ohkubo, C.: Influence of thickness and undercut of thermoplastic resin clasps on retentive force. Dent. Mater. J. 32(3), 381\u2013389 (2013)","journal-title":"Dent. Mater. J."},{"issue":"2","key":"61_CR4","doi-asserted-by":"publisher","first-page":"286","DOI":"10.4103\/1305-7456.178304","volume":"10","author":"MS Bilgin","year":"2016","unstructured":"Bilgin, M.S., Baytaroglu, E.N., Erdem, A., Dilber, E.: A review of computer-aided design\/computer aided manufacture techniques for removable denture fabrication. Eur. J. Dent. 10(2), 286\u2013291 (2016)","journal-title":"Eur. J. Dent."},{"issue":"7","key":"61_CR5","doi-asserted-by":"publisher","first-page":"4766","DOI":"10.19082\/4766","volume":"9","author":"AD Ayman","year":"2017","unstructured":"Ayman, A.D.: The residual monomer content and mechanical properties of CAD\\CAM resins used in the fabrication of complete dentures as compared to heat cured resins. Electron. Phys. 9(7), 4766\u20134772 (2017)","journal-title":"Electron. Phys."},{"issue":"4","key":"61_CR6","doi-asserted-by":"publisher","first-page":"526","DOI":"10.4012\/dmj.2017-207","volume":"37","author":"M Srinivasan","year":"2018","unstructured":"Srinivasan, M., Gjengedal, H., Cattani-Lorente, M., Moussa, M., Durual, S., Schimmel, M., et al.: CAD\/CAM milled complete removable dental prostheses: an in vitro evaluation of biocompatibility, mechanical properties, and surface roughness. Dent. Mater. J. 37(4), 526\u2013533 (2018)","journal-title":"Dent. Mater. J."},{"issue":"2","key":"61_CR7","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1016\/j.jpor.2014.03.002","volume":"58","author":"K Fueki","year":"2014","unstructured":"Fueki, K., Ohkubo, C., Yatabe, M., Arakawa, I., Arita, M., Ino, S., et al.: Clinical application of removable partial dentures using thermoplastic resin. Part II: material properties and clinical features of non-metal clasp dentures. J. Prosthodont. Res. 58(2), 71\u201384 (2014)","journal-title":"J. Prosthodont. Res."},{"issue":"6","key":"61_CR8","doi-asserted-by":"publisher","first-page":"950","DOI":"10.4012\/dmj.2017-373","volume":"37","author":"HH Lee","year":"2018","unstructured":"Lee, H.H., Lee, J.H., Yang, T.H., Kim, Y.J., Kim, S.C., Kim, G.R., et al.: Evaluation of the flexural mechanical properties of various thermoplastic denture base polymers. Dent. Mater. J. 37(6), 950\u2013956 (2018)","journal-title":"Dent. Mater. J."},{"issue":"3","key":"61_CR9","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1016\/0267-6605(94)90135-X","volume":"17","author":"JS Fitton","year":"1994","unstructured":"Fitton, J.S., Davies, E.H., Howlett, J.A., Pearson, G.J.: The physical properties of a polyacetal denture resin. Clin. Mater. 17(3), 125\u2013129 (1994)","journal-title":"Clin. Mater."},{"issue":"3","key":"61_CR10","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1016\/j.prosdent.2005.06.009","volume":"94","author":"T Arda","year":"2005","unstructured":"Arda, T., Arikan, A.: An in vitro comparison of retentive force and deformation of acetal resin and cobalt-chromium clasps. J. Prosthet. Dent. 94(3), 267\u2013274 (2005)","journal-title":"J. Prosthet. Dent."},{"issue":"4","key":"61_CR11","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1111\/jopr.12639","volume":"28","author":"M Al-Rabab\u2019ah","year":"2017","unstructured":"Al-Rabab\u2019ah, M., Hamadneh, W., Alsalem, I., Khraisat, A., AbuKaraky, A.: Use of high performance polymers as dental implant abutments and frameworks: a case series report. J. Prosthodont. 28(4), 365\u2013372 (2017)","journal-title":"J. Prosthodont."},{"issue":"7","key":"61_CR12","doi-asserted-by":"publisher","first-page":"580","DOI":"10.1111\/jopr.12325","volume":"25","author":"P Zoidis","year":"2016","unstructured":"Zoidis, P., Papathanasiou, I., Polyzois, G.: The use of a modified poly-ether-ether-ketone (PEEK) as an alternative framework material for removable dental prostheses: a clinical report. J. Prosthodont. 25(7), 580\u2013584 (2016)","journal-title":"J. Prosthodont."},{"issue":"2","key":"61_CR13","doi-asserted-by":"publisher","first-page":"e595","DOI":"10.1111\/jopr.12968","volume":"28","author":"IE Harb","year":"2019","unstructured":"Harb, I.E., Abdel-Khalek, E.A., Hegazy, S.A.: CAD\/CAM constructed poly(etheretherketone) (PEEK) framework of Kennedy class I removable partial denture: a clinical report. J. Prosthodont. 28(2), e595\u2013e598 (2019)","journal-title":"J. Prosthodont."},{"issue":"4","key":"61_CR14","first-page":"448","volume":"24","author":"MG Wiesli","year":"2015","unstructured":"Wiesli, M.G., Ozcan, M.: High-performance polymers and their potential application as medical and oral implant materials: a review. Implant Dent. 24(4), 448\u2013457 (2015)","journal-title":"Implant Dent."},{"key":"61_CR15","first-page":"1373127","volume":"2017","author":"KS Lee","year":"2017","unstructured":"Lee, K.S., Shin, J.H., Kim, J.E., Kim, J.H., Lee, W.C., Shin, S.W., et al.: Biomechanical evaluation of a tooth restored with high performance polymer PEKK post-core system: a 3D finite element analysis. Biomed. Res. Int. 2017, 1373127 (2017)","journal-title":"Biomed. Res. Int."},{"issue":"5","key":"61_CR16","doi-asserted-by":"publisher","first-page":"451","DOI":"10.11607\/ijp.4688","volume":"29","author":"KH Han","year":"2016","unstructured":"Han, K.H., Lee, J.Y., Shin, S.W.: Implant- and tooth-supported fixed prostheses using a high-performance polymer (Pekkton) framework. Int. J. Prosthodont. 29(5), 451\u2013454 (2016)","journal-title":"Int. J. Prosthodont."},{"issue":"1","key":"61_CR17","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1016\/j.jpor.2015.10.001","volume":"60","author":"S Najeeb","year":"2016","unstructured":"Najeeb, S., Zafar, M.S., Khurshid, Z., Siddiqui, F.: Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics. J. Prosthodont. Res. 60(1), 12\u201319 (2016)","journal-title":"J. Prosthodont. Res."},{"issue":"4","key":"61_CR18","doi-asserted-by":"publisher","first-page":"577","DOI":"10.2334\/josnusd.52.577","volume":"52","author":"MA Abuzar","year":"2010","unstructured":"Abuzar, M.A., Bellur, S., Duong, N., Kim, B.B., Lu, P., Palfreyman, N., et al.: Evaluating surface roughness of a polyamide denture base material in comparison with poly (methyl methacrylate). J. Oral Sci. 52(4), 577\u2013581 (2010)","journal-title":"J. Oral Sci."},{"issue":"1 Suppl.","key":"61_CR19","first-page":"1","volume":"16","author":"M Vojdani","year":"2015","unstructured":"Vojdani, M., Giti, R.: Polyamide as a denture base material: a literature review. J. Dent. (Shiraz) 16(1 Suppl.), 1\u20139 (2015)","journal-title":"J. Dent. (Shiraz)"},{"issue":"4","key":"61_CR20","doi-asserted-by":"publisher","first-page":"353","DOI":"10.4012\/dmj.2009-114","volume":"29","author":"Y Takabayashi","year":"2010","unstructured":"Takabayashi, Y.: Characteristics of denture thermoplastic resins for non-metal clasp dentures. Dent. Mater. J. 29(4), 353\u2013361 (2010)","journal-title":"Dent. Mater. J."},{"issue":"1","key":"61_CR21","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.jpor.2017.05.001","volume":"62","author":"H Nasution","year":"2018","unstructured":"Nasution, H., Kamonkhantikul, K., Arksornnukit, M., Takahashi, H.: Pressure transmission area and maximum pressure transmission of different thermoplastic resin denture base materials under impact load. J. Prosthodont. Res. 62(1), 44\u201349 (2018)","journal-title":"J. Prosthodont. Res."},{"issue":"1","key":"61_CR22","first-page":"ZC37","volume":"10","author":"A Meenakshi","year":"2016","unstructured":"Meenakshi, A., Gupta, R., Bharti, V., Sriramaprabu, G., Prabhakar, R.: An evaluation of retentive ability and deformation of acetal resin and cobalt-chromium clasps. J. Clin. Diagn. Res. 10(1), ZC37\u2013ZC41 (2016)","journal-title":"J. Clin. Diagn. Res."},{"issue":"1","key":"61_CR23","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1111\/j.1834-7819.2008.01085.x","volume":"54","author":"T Jiao","year":"2009","unstructured":"Jiao, T., Chang, T., Caputo, A.A.: Load transfer characteristics of unilateral distal extension removable partial dentures with polyacetal resin supporting components. Aust. Dent. J. 54(1), 31\u201337 (2009)","journal-title":"Aust. Dent. J."},{"issue":"6","key":"61_CR24","doi-asserted-by":"publisher","first-page":"867","DOI":"10.1016\/j.prosdent.2017.09.008","volume":"119","author":"JH Dawson","year":"2018","unstructured":"Dawson, J.H., Hyde, B., Hurst, M., Harris, B.T., Lin, W.S.: Polyetherketoneketone (PEKK), a framework material for complete fixed and removable dental prostheses: a clinical report. J. Prosthet. Dent. 119(6), 867\u2013872 (2018)","journal-title":"J. Prosthet. Dent."}],"container-title":["Lecture Notes in Computational Vision and Biomechanics","VipIMAGE 2019"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-030-32040-9_61","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,9,27]],"date-time":"2019-09-27T06:13:53Z","timestamp":1569564833000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-030-32040-9_61"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019]]},"ISBN":["9783030320393","9783030320409"],"references-count":24,"URL":"https:\/\/doi.org\/10.1007\/978-3-030-32040-9_61","relation":{},"ISSN":["2212-9391","2212-9413"],"issn-type":[{"type":"print","value":"2212-9391"},{"type":"electronic","value":"2212-9413"}],"subject":[],"published":{"date-parts":[[2019]]},"assertion":[{"value":"28 September 2019","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"VipIMAGE","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"ECCOMAS Thematic Conference on Computational Vision and Medical Image Processing","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Porto","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Portugal","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2019","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"16 October 2019","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"18 October 2019","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"viplmage2019","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"https:\/\/paginas.fe.up.pt\/~vipimage","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}