{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,27]],"date-time":"2025-03-27T21:40:22Z","timestamp":1743111622151,"version":"3.40.3"},"publisher-location":"Cham","reference-count":18,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783030355326"},{"type":"electronic","value":"9783030355333"}],"license":[{"start":{"date-parts":[[2020,9,15]],"date-time":"2020-09-15T00:00:00Z","timestamp":1600128000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,9,15]],"date-time":"2020-09-15T00:00:00Z","timestamp":1600128000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021]]},"DOI":"10.1007\/978-3-030-35533-3_48","type":"book-chapter","created":{"date-parts":[[2020,9,14]],"date-time":"2020-09-14T11:57:13Z","timestamp":1600084633000},"page":"405-410","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Construction of an Experimental Chamber Equipped with Ventilated Windows"],"prefix":"10.1007","author":[{"given":"Eus\u00e9bio","family":"Concei\u00e7\u00e3o","sequence":"first","affiliation":[]},{"given":"Jo\u00e3o","family":"Gomes","sequence":"additional","affiliation":[]},{"given":"Maria Manuela","family":"L\u00facio","sequence":"additional","affiliation":[]},{"given":"Maria In\u00eas","family":"Concei\u00e7\u00e3o","sequence":"additional","affiliation":[]},{"given":"Hazim","family":"Awbi","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2020,9,15]]},"reference":[{"key":"48_CR1","unstructured":"ASHRAE Standard 55. (2013). Thermal environmental conditions for human occupancy. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta, GA, USA."},{"key":"48_CR2","unstructured":"ASHRAE Standard 62.1. (2016). Ventilation for acceptable indoor air quality. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta, GA, USA."},{"key":"48_CR3","doi-asserted-by":"publisher","first-page":"38","DOI":"10.3390\/buildings6030038","volume":"6","author":"E Concei\u00e7\u00e3o","year":"2016","unstructured":"Concei\u00e7\u00e3o, E., & L\u00facio, M. (2016). Numerical simulation of the application of solar radiant systems, internal airflow and occupants\u2019 presence in the improvement of comfort in winter conditions. Buildings, 6, 38.","journal-title":"Buildings"},{"key":"48_CR4","volume-title":"Thermal comfort","author":"P Fanger","year":"1970","unstructured":"Fanger, P. (1970). Thermal comfort. Copenhagen: Danish Technical Press."},{"key":"48_CR5","doi-asserted-by":"publisher","first-page":"1052","DOI":"10.1016\/j.rser.2016.01.130","volume":"60","author":"A Ghaffarianhoseini","year":"2016","unstructured":"Ghaffarianhoseini, A., Ghaffarianhoseini, A., Berardi, U., Tookey, J., Li, D., & Kariminia, S. (2016). Exploring the advantages and challenges of double-skin fa\u00e7ades (DSFs). Renewable and Sustainable Energy Reviews, 60, 1052\u20131065.","journal-title":"Renewable and Sustainable Energy Reviews"},{"key":"48_CR6","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1016\/j.enbuild.2015.05.057","volume":"102","author":"A Hazem","year":"2015","unstructured":"Hazem, A., Ameghchouche, M., & Bougriou, C. (2015). A numerical analysis of the air ventilation management and assessment of the behavior of double skin facades. Energy and Buildings, 102, 225\u2013236.","journal-title":"Energy and Buildings"},{"key":"48_CR7","unstructured":"ISO 7730. (2005). Ergonomics of the thermal environments\u2014analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria. Switzerland: International Organization for Standardization."},{"issue":"8","key":"48_CR8","doi-asserted-by":"publisher","first-page":"1567","DOI":"10.1016\/j.enbuild.2008.02.017","volume":"40","author":"T Jiru","year":"2008","unstructured":"Jiru, T., & Haghighat, F. (2008). Modeling ventilated double skin fa\u00e7ade\u2014A zonal approach. Energy and Buildings, 40(8), 1567\u20131576.","journal-title":"Energy and Buildings"},{"key":"48_CR9","doi-asserted-by":"publisher","first-page":"304","DOI":"10.1016\/j.proeng.2015.08.431","volume":"118","author":"J Lee","year":"2015","unstructured":"Lee, J., & Chang, D. (2015). Influence on vertical shading device orientation and thickness on the natural ventilation and acoustical performance of a double skin fa\u00e7ade. Procedia Engineering, 118, 304\u2013309.","journal-title":"Procedia Engineering"},{"key":"48_CR10","doi-asserted-by":"publisher","first-page":"310","DOI":"10.1016\/j.proeng.2015.08.432","volume":"118","author":"J Lee","year":"2015","unstructured":"Lee, J., Alshayeb, M., & Chang, D. (2015). A study of shading device configuration on the natural ventilation efficiency and energy performance of a double skin fa\u00e7ade. Procedia Engineering, 118, 310\u2013317.","journal-title":"Procedia Engineering"},{"key":"48_CR11","doi-asserted-by":"publisher","first-page":"5116","DOI":"10.1016\/j.egypro.2019.01.688","volume":"158","author":"Y Li","year":"2019","unstructured":"Li, Y., Darkwa, J., & Su, W. (2019). Investigation on thermal performance of an integrated phase change material blind system for double skin fa\u00e7ade buildings. Energy Procedia, 158, 5116\u20135123.","journal-title":"Energy Procedia"},{"key":"48_CR12","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1007\/s12273-019-0511-y","volume":"12","author":"E Lucchino","year":"2019","unstructured":"Lucchino, E., Goia, F., Lobaccaro, G., & Chaudhary, G. (2019). Modelling of double skin facades in whole-building energy simulation tools: A review of current practices and possibilities for future developments. Building Simulation, 12, 3\u201327.","journal-title":"Building Simulation"},{"key":"48_CR13","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1016\/j.energy.2018.09.175","volume":"165","author":"Y Luo","year":"2018","unstructured":"Luo, Y., Ling Zhang, L., Liu, Z., Xie, L., Wang, X., & Wu, J. (2018). Experimental study and performance evaluation of a PV-blind embedded double skin fa\u00e7ade in winter season. Energy, 165, 326\u2013342.","journal-title":"Energy"},{"key":"48_CR14","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1016\/j.buildenv.2015.02.005","volume":"87","author":"F Marques da Silva","year":"2015","unstructured":"Marques da Silva, F., Gomes, M., & Rodrigues, A. (2015). Measuring and estimating airflow in naturally ventilated double skin fa\u00e7ades. Building and Environment, 87, 292\u2013301.","journal-title":"Building and Environment"},{"key":"48_CR15","doi-asserted-by":"publisher","first-page":"4882","DOI":"10.3390\/en8064882","volume":"8","author":"J Parra","year":"2015","unstructured":"Parra, J., Guardo, A., Egusquiza, E., & Alavedra, P. (2015). Thermal performance of ventilated double skin fa\u00e7ades with venetian blinds. Energies, 8, 4882\u20134898.","journal-title":"Energies"},{"key":"48_CR16","unstructured":"Poirazis H. (2004). Double skin fa\u00e7ades for office buildings\u2014Literature review (Report EBD-R\u201304\/3). Sweden: Department of Construction and Architecture, Lund University."},{"key":"48_CR17","unstructured":"Portaria n.\u00ba 353-A. (2013). Requisitos de ventila\u00e7\u00e3o e qualidade do ar interior. Di\u00e1rio da Rep\u00fablica n.\u00ba 235\/2013, 1\u00ba Suplemento, S\u00e9rie I de 2013-12-04. Portuguese Standard, Lisboa, Portugal."},{"key":"48_CR18","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1016\/j.solener.2015.01.040","volume":"114","author":"F Xue","year":"2015","unstructured":"Xue, F., & Li, X. (2015). A fast assessment method for thermal performance of naturally ventilated double-skin fa\u00e7ades during cooling season. Solar Energy, 114, 303\u2013313.","journal-title":"Solar Energy"}],"container-title":["Advances in Science, Technology &amp; Innovation","Sustainability and Automation in Smart Constructions"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-030-35533-3_48","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,9,14]],"date-time":"2020-09-14T12:06:32Z","timestamp":1600085192000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-030-35533-3_48"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,15]]},"ISBN":["9783030355326","9783030355333"],"references-count":18,"URL":"https:\/\/doi.org\/10.1007\/978-3-030-35533-3_48","relation":{},"ISSN":["2522-8714","2522-8722"],"issn-type":[{"type":"print","value":"2522-8714"},{"type":"electronic","value":"2522-8722"}],"subject":[],"published":{"date-parts":[[2020,9,15]]},"assertion":[{"value":"15 September 2020","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}}]}}