{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,22]],"date-time":"2026-02-22T22:20:45Z","timestamp":1771798845586,"version":"3.50.1"},"publisher-location":"Cham","reference-count":217,"publisher":"Springer International Publishing","isbn-type":[{"value":"9783030723842","type":"print"},{"value":"9783030723859","type":"electronic"}],"license":[{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021]]},"DOI":"10.1007\/978-3-030-72385-9_5","type":"book-chapter","created":{"date-parts":[[2021,6,8]],"date-time":"2021-06-08T14:07:22Z","timestamp":1623161242000},"page":"79-124","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Ventilative Cooling and Air Pollutants"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8643-1180","authenticated-orcid":false,"given":"Guilherme","family":"Carrilho da Gra\u00e7a","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3087-3123","authenticated-orcid":false,"given":"Nuno R.","family":"Martins","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2021,6,9]]},"reference":[{"key":"5_CR1","unstructured":"United Nations Department of Economic and Social Affairs (2014) World Urbanization Prospects\u2014The 2014 Revision\u2014Highlights, United Nations, New York, New York, US. ISBN 978 92 1 151517 6, https:\/\/esa.un.org\/unpd\/wup\/publications\/files\/wup2014-highlights.pdf"},{"key":"5_CR2","doi-asserted-by":"publisher","unstructured":"Baklanov A, Molina LT, Gauss M (2016) Megacities, air quality and climate. Atmos Environ 126:235\u2013249. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/j.atmosenv.2015.11.059","DOI":"10.1016\/j.atmosenv.2015.11.059"},{"key":"5_CR3","doi-asserted-by":"publisher","unstructured":"Chen C, Zhao B (2011) Review of relationship between indoor and outdoor particles: I\/O ratio, infiltration factor and penetration factor. Atmos Environ 45(2):275\u2013288. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/j.atmosenv.2010.09.048","DOI":"10.1016\/j.atmosenv.2010.09.048"},{"key":"5_CR4","doi-asserted-by":"publisher","unstructured":"Habre R, Coull B, Moshier E, Godbold J, Grunin A, Nath A, Castro W, Schachter N, Rohr A, Kattan M, Spengler J, Koutrakis P (2014) Sources of indoor air pollution in New York City residences of asthmatic children. J Expo Sci Environ Epidemiol 24(3):269\u2013278. ISSN 1559 0631, https:\/\/doi.org\/10.1038\/jes.2013.74","DOI":"10.1038\/jes.2013.74"},{"key":"5_CR5","doi-asserted-by":"publisher","unstructured":"Chwieduk DA (2017) Towards modern options of energy conservation in buildings. Renew Energy 101:1194\u20131202. ISSN 0960 1481, https:\/\/doi.org\/10.1016\/j.renene.2016.09.061","DOI":"10.1016\/j.renene.2016.09.061"},{"key":"5_CR6","doi-asserted-by":"publisher","unstructured":"Rupp RF, V\u00e1squez NG, Lamberts R (2015) A review of human thermal comfort in the built environment. Energy Build 105:178\u2013205. ISSN 0378 7788, https:\/\/doi.org\/10.1016\/j.enbuild.2015.07.047","DOI":"10.1016\/j.enbuild.2015.07.047"},{"key":"5_CR7","doi-asserted-by":"publisher","first-page":"520","DOI":"10.1016\/j.apenergy.2013.10.008","volume":"114","author":"IO Perez","year":"2014","unstructured":"Perez IO, \u00d8stergaard PA (2014) Potential of natural ventilation in temperate countries\u2014a case study of Denmark. Appl Energy 114:520\u2013530. ISSN 0306 2619, https:\/\/doi.org\/10.1016\/j.apenergy.2013.10.008","journal-title":"Appl Energy"},{"key":"5_CR8","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1016\/j.apenergy.2014.05.035","volume":"130","author":"IO Perez","year":"2014","unstructured":"Perez IO, \u00d8stergaard PA (2014) Energy saving potential of utilizing natural ventilation under warm conditions\u2014a case study of Mexico. Appl Energy 130:20\u20132619. ISSN 0306 2619, https:\/\/doi.org\/10.1016\/j.apenergy.2014.05.035","journal-title":"Appl Energy"},{"key":"5_CR9","doi-asserted-by":"publisher","unstructured":"da Gra\u00e7a GC, Martins NR, Horta CS (2012) Thermal and airflow simulation of a naturally ventilated shopping mall. Energy Build 50:177\u2013188. ISSN 0378 7788, https:\/\/doi.org\/10.1016\/j.enbuild.2012.03.037","DOI":"10.1016\/j.enbuild.2012.03.037"},{"key":"5_CR10","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1016\/j.enbuild.2016.07.034","volume":"128","author":"M Santamouris","year":"2016","unstructured":"Santamouris M (2016) Cooling the buildings\u2014past, present and future. Energy Build 128:617\u2013638. ISSN 0378 7788, https:\/\/doi.org\/10.1016\/j.enbuild.2016.07.034","journal-title":"Energy Build"},{"key":"5_CR11","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1016\/j.apenergy.2014.02.041","volume":"123","author":"R Ramponi","year":"2014","unstructured":"Ramponi R, Angelotti A, Blocken B (2014) Energy saving potential of night ventilation: sensitivity to pressure coefficients for different European climates. Appl Energy 123:185\u2013195. ISSN 0306 2619, https:\/\/doi.org\/10.1016\/j.apenergy.2014.02.041","journal-title":"Appl Energy"},{"key":"5_CR12","doi-asserted-by":"publisher","first-page":"606","DOI":"10.1016\/j.apenergy.2011.11.066","volume":"92","author":"BR Hughes","year":"2012","unstructured":"Hughes BR, Calautit JK, Ghani SA (2012) The development of commercial wind towers for natural ventilation: a review. Appl Energy 92:606\u2013627. ISSN 0306 2619, https:\/\/doi.org\/10.1016\/j.apenergy.2011.11.066","journal-title":"Appl Energy"},{"key":"5_CR13","doi-asserted-by":"publisher","unstructured":"Sepp\u00e4nen O, Fisk WJ (2002) Association of ventilation system type with SBS symptoms in office workers. Indoor Air 12(2):98\u2013112. ISSN 1600 0668, https:\/\/doi.org\/10.1034\/j.1600-0668.2002.01111.x","DOI":"10.1034\/j.1600-0668.2002.01111.x"},{"key":"5_CR14","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1016\/j.buildenv.2013.05.002","volume":"67","author":"SM Dutton","year":"2013","unstructured":"Dutton SM, Banks D, Brunswick SL, Fisk WJ (2013) Health and economic implications of natural ventilation in California offices. Build Environ 67:34\u201345. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2013.05.002","journal-title":"Build Environ"},{"key":"5_CR15","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1016\/j.apenergy.2014.06.032","volume":"131","author":"C Li","year":"2014","unstructured":"Li C, Hong T, Yan D (2014) An insight into actual energy use and its drivers in high performance buildings. Appl Energy 131:394\u2013410. ISSN 0306 2619, https:\/\/doi.org\/10.1016\/j.apenergy.2014.06.032","journal-title":"Appl Energy"},{"key":"5_CR16","doi-asserted-by":"publisher","first-page":"660","DOI":"10.1016\/j.apenergy.2016.07.019","volume":"179","author":"Z Tong","year":"2016","unstructured":"Tong Z, Chen Y, Malkawi A, Liu Z, Freeman RB (2016) Energy saving potential of natural ventilation in China: the impact of ambient air pollution. Appl Energy 179:660\u2013668. https:\/\/doi.org\/10.1016\/j.apenergy.2016.07.019","journal-title":"Appl Energy"},{"key":"5_CR17","doi-asserted-by":"publisher","unstructured":"Lave LB, Seskin EP (1970) Air pollution and human health. Science 169(3947):723\u2013733. ISSN 1095 9203, https:\/\/doi.org\/10.1126\/science.169.3947.723","DOI":"10.1126\/science.169.3947.723"},{"key":"5_CR18","unstructured":"Ferris Jr BG, Speizer FE, Spengler JD, Dockery D, Bishop YMM, Wolfson M, Humble C (1979) Effects of Sulfur Oxides and respirable particles on human health. methodology and demography of populations in study. Am Rev Respir Dis 120(4):767\u2013779. ISSN 0003 0805, https:\/\/www.atsjournals.org\/doi\/abs\/10.1164\/arrd.1979.120.4.767"},{"key":"5_CR19","unstructured":"World Health Organization (2013) Review of evidence on health aspects of air pollution\u2014REVIHAAP project: Technical Report, WHO Regional Office for Europe, Copenhagen, Denmark. http:\/\/www.euro.who.int\/__data\/assets\/pdf_file\/0004\/193108\/REVIHAAP-Final-technical-report.pdf"},{"issue":"11","key":"5_CR20","doi-asserted-by":"publisher","first-page":"1811","DOI":"10.1016\/S1352-2310(02)00157-7","volume":"36","author":"TL Thatcher","year":"2002","unstructured":"Thatcher TL, Lai Alvin CK, Jackson RM, Sextro RG, Nazaroff WW (2002) Effects of room furnishings and air speed on particle deposition rates indoors. Atmos Environ 36(11):1811\u20131819. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/S1352-2310(02)00157-7","journal-title":"Atmos Environ"},{"key":"5_CR21","doi-asserted-by":"publisher","first-page":"853","DOI":"10.1016\/j.apenergy.2015.09.082","volume":"184","author":"J Meng","year":"2016","unstructured":"Meng J, Liu J, Guo S, Huang Y, Tao S (2016) The impact of domestic and foreign trade on energy related PM emissions in Beijing. Appl Energy 184:853\u2013862. ISSN 0306 2619, https:\/\/doi.org\/10.1016\/j.apenergy.2015.09.082","journal-title":"Appl Energy"},{"key":"5_CR22","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1016\/j.buildenv.2015.05.004","volume":"92","author":"WJ Farrell","year":"2015","unstructured":"Farrell WJ, Cavellin LD, Weichenthal S, Goldberg M, Hatzopoulou M (2015) Capturing the urban canyon effect on particle number concentrations across a large road network using spatial analysis tools. Build Environ 92:328\u2013334. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2015.05.004","journal-title":"Build Environ"},{"key":"5_CR23","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1016\/j.atmosenv.2015.03.022","volume":"113","author":"ME Popa","year":"2015","unstructured":"Popa ME, Segers AJ, van der Gon HACD, Krol MC, Visschedijk AJH, Schaap M, R\u00f6ckmann T (2015) Impact of a future H2 transportation on atmospheric pollution in Europe. Atmos Environ 113:208\u2013222. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/j.atmosenv.2015.03.022","journal-title":"Atmos Environ"},{"key":"5_CR24","unstructured":"Westphalen D, Koszalinski S (1999) Energy consumption characteristics of commercial building HVAC systems\u2014Volume II: thermal distribution, auxiliary equipment, and ventilation, office of building equipment, office of building technology state and community programs, US Department of Energy, Oct 1999. https:\/\/www1.eere.energy.gov\/buildings\/publications\/pdfs\/commercial_initiative\/hvac_volume2_final_report.pdf"},{"key":"5_CR25","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1016\/j.atmosenv.2014.09.007","volume":"98","author":"P Azimi","year":"2014","unstructured":"Azimi P, Zhao D, Stephens B (2014) Estimates of HVAC filtration efficiency for fine and ultrafine particles of outdoor origin. Atmos Environ 98:337\u2013346. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/j.atmosenv.2014.09.007","journal-title":"Atmos Environ"},{"issue":"3","key":"5_CR26","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1016\/j.enbuild.2007.03.007","volume":"40","author":"LP Lombard","year":"2008","unstructured":"Lombard LP, Ortiz J, Christine Pout A (2008) Estimates of HVAC filtration efficiency for fine and ultrafine particles of outdoor origin. Energy Build 40(3):394\u2013398. ISSN 0378 7788, https:\/\/doi.org\/10.1016\/j.enbuild.2007.03.007","journal-title":"Energy Build"},{"key":"5_CR27","doi-asserted-by":"publisher","unstructured":"Danny Harvey LD (2013) Recent advances in sustainable buildings: review of the energy and cost performance of the state of the art best practices from around the world. Ann Rev Environ Res 38:281\u2013309. ISSN 1543 5938, https:\/\/doi.org\/10.1146\/annurev-environ-070312-101940","DOI":"10.1146\/annurev-environ-070312-101940"},{"key":"5_CR28","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1016\/j.buildenv.2006.06.031","volume":"0360","author":"S Herkel","year":"2008","unstructured":"Herkel S, Knapp U, Pfafferott J (2008) Towards a model of user behaviour regarding the manual control of windows in office buildings. Build Environ 0360:1323. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2006.06.031","journal-title":"Build Environ"},{"key":"5_CR29","unstructured":"International Organization for Standardization (2005) ISO 7730:2005\u2014Ergonomics of the thermal environment\u2014Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria, Nov 2005"},{"key":"5_CR30","doi-asserted-by":"publisher","unstructured":"Zhang H, Arens E, Zhai Y (2015) A review of the corrective power of personal comfort systems in non neutral ambient environments. Build Environ 91:15\u201341. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2015.03.013","DOI":"10.1016\/j.buildenv.2015.03.013"},{"key":"5_CR31","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1016\/j.buildenv.2015.04.003","volume":"0360","author":"Y Zhai","year":"2015","unstructured":"Zhai Y, Zhang Y, Zhang H, Pasut W, Arens E, Meng Q (2015) Human comfort and perceived air quality in warm and humid environments with ceiling fans. Build Environ 0360:1323. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2015.04.003","journal-title":"Build Environ"},{"key":"5_CR32","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1016\/j.buildenv.2008.05.016","volume":"0360","author":"S Watanabe","year":"2009","unstructured":"Watanabe S, Shimomura T, Miyazaki H (2009) Thermal evaluation of a chair with fans as an individually controlled system. Build Environ 0360:1323. https:\/\/doi.org\/10.1016\/j.buildenv.2008.05.016","journal-title":"Build Environ"},{"key":"5_CR33","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/j.enbuild.2015.12.016","volume":"113","author":"H Pallubinsky","year":"2016","unstructured":"Pallubinsky H, Schellen L, Rieswijk TA, Breukel CMGAM, Kingma BRM, van Marken Lichtenbelt WD (2016) Local cooling in a warm environment. Energy Build 113:15\u201322. ISSN 0378 7788, https:\/\/doi.org\/10.1016\/j.enbuild.2015.12.016","journal-title":"Energy Build"},{"key":"5_CR34","doi-asserted-by":"publisher","unstructured":"Pasut W, Zhang H, Arens ED, Zhai Y (2015) Energy efficient comfort with a heated\/cooled chair: results from human subject tests. Build Environ 84:10\u201321. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2014.10.026","DOI":"10.1016\/j.buildenv.2014.10.026"},{"key":"5_CR35","doi-asserted-by":"publisher","unstructured":"Martins NR, da Gra\u00e7a GC (2008) Impact of PM2.5 in indoor urban environments: a review. Sustain Cities Soc 42:259\u2013275. ISSN 2210 6707, https:\/\/doi.org\/10.1016\/j.scs.2018.07.011","DOI":"10.1016\/j.scs.2018.07.011"},{"key":"5_CR36","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1016\/j.buildenv.2011.07.004","volume":"47","author":"C Chen","year":"2012","unstructured":"Chen C, Zhao B, Zhou W, Jiang X, Tan Z (2012) A methodology for predicting particle penetration factor through cracks of windows and doors for actual engineering application. Build Environ 47:339\u2013348. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2011.07.004","journal-title":"Build Environ"},{"key":"5_CR37","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1016\/j.atmosenv.2014.01.033","volume":"89","author":"G Shen","year":"2014","unstructured":"Shen G, Xue M, Chen Y, Yang C, Li W, Shen H, Huang Y, Zhang Y, Chen H, Zhu Y, Haisuo W, Ding A, Tao S (2014) Comparison of carbonaceous particulate matter emission factors among different solid fuels burned in residential stoves. Atmos Environ 89:337\u2013345. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/j.atmosenv.2014.01.033","journal-title":"Atmos Environ"},{"key":"5_CR38","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1016\/j.buildenv.2015.03.016","volume":"91","author":"M Shan","year":"2015","unstructured":"Shan M, Wang P, Li J, Yue G, Yang X (2015) Energy and environment in Chinese rural buildings: situations, challenges, and intervention strategies. Build Environ 91:271\u2013282. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2015.03.016","journal-title":"Build Environ"},{"key":"5_CR39","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1016\/j.scitotenv.2016.01.038","volume":"548\u2013546","author":"T Li","year":"2016","unstructured":"Li T, Cao S, Fan D, Zhang Y, Wang B, Zhao X, Leaderer BP, Shen G, Zhang Y, Duan X (2016) Household concentrations and personal exposure of PM2.5 among urban residents using different cooking fuels. Sci Total Environ 548\u2013546:6\u201312. ISSN 0048 9697, https:\/\/doi.org\/10.1016\/j.scitotenv.2016.01.038","journal-title":"Sci Total Environ"},{"key":"5_CR40","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1016\/j.atmosenv.2011.11.054","volume":"49","author":"AL Northcross","year":"2012","unstructured":"Northcross AL, Katharine Hammond S, Canuz E, Smith KR (2012) Dioxin inhalation doses from wood combustion in indoor cookfires. Atmos Environ 49:415\u2013418. https:\/\/doi.org\/10.1016\/j.atmosenv.2011.11.054","journal-title":"Atmos Environ"},{"key":"5_CR41","doi-asserted-by":"publisher","unstructured":"Canha N, Almeida SM, do Carmo Freitas M, Wolterbeek HT, Cardoso J, Pio C, Caseiro A (2014) Impact of wood burning on indoor PM2.5 in a primary school in rural Portugal. Atmos Environ 94, 663\u2013670. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/j.atmosenv.2014.05.080","DOI":"10.1016\/j.atmosenv.2014.05.080"},{"key":"5_CR42","doi-asserted-by":"publisher","first-page":"312","DOI":"10.1016\/j.atmosenv.2016.06.073","volume":"141","author":"X Yue","year":"2016","unstructured":"Yue X, Wang Y, Chen Y, Tian C, Feng Y, Li J, Zhang G (2016) Characterization of fine and carbonaceous particles emissions from pelletized biomass coal blends combustion: Implications on residential crop residue utilization in China. Atmos Environ 141:312\u2013319. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/j.atmosenv.2016.06.073","journal-title":"Atmos Environ"},{"key":"5_CR43","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1016\/j.atmosenv.2013.10.044","volume":"82","author":"HS Huboyo","year":"2014","unstructured":"Huboyo HS, Tohno S, Lestari P, Mizohata A, Okumura M (2014) Characteristics of indoor air pollution in rural mountainous and rural coastal communities in Indonesia. Atmos Environ 82:343\u2013350. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/j.atmosenv.2013.10.044","journal-title":"Atmos Environ"},{"key":"5_CR44","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1016\/j.atmosenv.2015.04.060","volume":"113","author":"AK Pokhrel","year":"2015","unstructured":"Pokhrel AK, Bates MN, Acharya J, Branth PV, Chandyo RK, Shrestha PS, Raut AK, Smith KR (2015) PM2.5 in household kitchens of Bhaktapur, Nepal, using four different cooking fuels. Atmos Environ 113:159\u2013168. https:\/\/doi.org\/10.1016\/j.atmosenv.2015.04.060","journal-title":"Atmos Environ"},{"key":"5_CR45","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1016\/j.atmosenv.2014.12.066","volume":"104","author":"W Huang","year":"2015","unstructured":"Huang W, Baumgartner J, Zhang Y, Wang Y, Schauer JJ (2015) Source apportionment of air pollution exposures of rural Chinese women cooking with biomass fuels. Atmos Environ 104:79\u201387. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/j.atmosenv.2014.12.066","journal-title":"Atmos Environ"},{"key":"5_CR46","unstructured":"World Health Organization (2005) Air Quality Guidelines\u2014Global Update 2005: Particulate matter, ozone, nitrogen dioxide and sulfur dioxide, WHO Regional Office for Europe, 2006, Copenhagen, Denmark. ISBN 92 890 2192 6, http:\/\/www.euro.who.int\/__data\/assets\/pdf_file\/0005\/78638\/E90038.pdf"},{"key":"5_CR47","unstructured":"Bennett D, Wu X, Trout A, Apte M, Faulkner D, Maddalena R, Sullivan D (2011) Indoor environmental quality and heating, ventilating and air conditioning survey of small and medium size commercial buildings\u2014Field study, California Energy Commission & California Air Resources Board, Oct 2011, CEC 500 2011 043. http:\/\/www.energy.ca.gov\/2011publications\/CEC-500-2011-043\/CEC-500-2011-043.pdf"},{"issue":"4","key":"5_CR48","doi-asserted-by":"publisher","first-page":"747","DOI":"10.1007\/s11869-013-0212-0","volume":"6","author":"R Goyal","year":"2013","unstructured":"Goyal R, Kumar P (2013) Indoor\u2013outdoor concentrations of particulate matter in nine microenvironments of a mix use commercial building in megacity Delhi. Air Qual Atmos Health 6(4):747\u2013757. ISSN 1873 9326, https:\/\/doi.org\/10.1007\/s11869-013-0212-0","journal-title":"Air Qual Atmos Health"},{"key":"5_CR49","doi-asserted-by":"publisher","unstructured":"Yassin MF, Al Thaqeb BEY, Al Mutiri EAE (2012) Assessment of indoor PM2.5 in different residential environments. Atmos Environ 56:65\u201368. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/j.atmosenv.2012.03.051","DOI":"10.1016\/j.atmosenv.2012.03.051"},{"issue":"5","key":"5_CR50","doi-asserted-by":"publisher","first-page":"1074","DOI":"10.1016\/j.buildenv.2010.11.006","volume":"46","author":"SW See","year":"2011","unstructured":"See SW, Balasubramanian R (2011) Characterization of fine particle emissions from incense burning. Build Environ 46(5):1074\u20131080. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2010.11.006","journal-title":"Build Environ"},{"key":"5_CR51","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1016\/j.buildenv.2015.01.012","volume":"87","author":"SC Kuo","year":"2015","unstructured":"Kuo SC, Tsai YI, Sopajaree K (2015) Emission identification and health risk potential of allergy causing fragrant substances in PM2.5 from incense burning. Build Environ 87:23\u201333. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2015.01.012","journal-title":"Build Environ"},{"key":"5_CR52","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1016\/j.atmosenv.2016.11.033","volume":"150","author":"E H\u00f6llbacher","year":"2017","unstructured":"H\u00f6llbacher E, Ters T, Gradinger CR, Srebotnik E (2017) Emissions of indoor air pollutants from six user scenarios in a model room. Atmos Environ 150:389\u2013394. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/j.atmosenv.2016.11.033","journal-title":"Atmos Environ"},{"key":"5_CR53","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1016\/j.atmosenv.2013.06.009","volume":"79","author":"TN Quang","year":"2013","unstructured":"Quang TN, He C, Morawska L, Knibbs LD (2013) Influence of ventilation and filtration on indoor particle concentrations in urban office buildings. Atmos Environ 79:41\u201352. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/j.atmosenv.2013.06.009","journal-title":"Atmos Environ"},{"key":"5_CR54","doi-asserted-by":"publisher","unstructured":"Dorizas PV, Assimakopoulos MN, Helmis C, Santamouris M (2015) An integrated evaluation study of the ventilation rate, the exposure and the indoor air quality in naturally ventilated classrooms in the Mediterranean region during spring. Sci Total Environ 502:557\u2013570. ISSN 0048 9697, https:\/\/doi.org\/10.1016\/j.scitotenv.2014.09.060","DOI":"10.1016\/j.scitotenv.2014.09.060"},{"key":"5_CR55","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1016\/j.buildenv.2012.03.005","volume":"56","author":"L Stabile","year":"2012","unstructured":"Stabile L, Fuoco FC, Buonanno G (2012) Characteristics of particles and black carbon emitted by combustion of incenses, candles and anti mosquito products. Build Environ 56:184\u2013191. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2012.03.005","journal-title":"Build Environ"},{"issue":"8","key":"5_CR56","doi-asserted-by":"publisher","first-page":"992","DOI":"10.1016\/j.buildenv.2005.04.024","volume":"41","author":"X Wang","year":"2006","unstructured":"Wang X, Bi X, Chen D, Sheng G, Jiamo F (2006) Hospital indoor respirable particles and carbonaceous composition. Build Environ 41(8):992\u20131000. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2005.04.024","journal-title":"Build Environ"},{"key":"5_CR57","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/j.buildenv.2014.03.016","volume":"77","author":"I Goldasteh","year":"2014","unstructured":"Goldasteh I, Tian Y, Ahmadi G, Ferro AR (2014) Human induced flow field and resultant particle resuspension and transport during gait cycle. Build Environ 77:101\u2013109. ISSN 0360 1323. https:\/\/doi.org\/10.1016\/j.buildenv.2014.03.016","journal-title":"Build Environ"},{"key":"5_CR58","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1016\/j.buildenv.2014.08.017","volume":"82","author":"N Serfozo","year":"2014","unstructured":"Serfozo N, Chatoutsidou SE, Lazaridis M (2014) The effect of particle resuspension during walking activity to PM10 mass and number concentrations in an indoor microenvironment. Build Environ 82:180\u2013189. ISSN 0360 1323. https:\/\/doi.org\/10.1016\/j.buildenv.2014.08.017","journal-title":"Build Environ"},{"key":"5_CR59","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1016\/j.buildenv.2015.03.036","volume":"90","author":"M Elbayoumi","year":"2015","unstructured":"Elbayoumi M, Ramli NA, Yusof NFFM (2015) Spatial and temporal variations in particulate matter concentrations in twelve schools environment in urban and overpopulated camps landscape. Build Environ 90:157\u2013167. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2015.03.036","journal-title":"Build Environ"},{"key":"5_CR60","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1016\/j.envpol.2016.05.023","volume":"215","author":"F Wang","year":"2016","unstructured":"Wang F, Meng D, Li X, Tan J (2016) Indoor outdoor relationships of PM2.5 in four residential dwellings in winter in the Yangtze River Delta, China. Environ Pollut 215:280\u2013289. ISSN 0269 7491, https:\/\/doi.org\/10.1016\/j.envpol.2016.05.023","journal-title":"Environ Pollut"},{"key":"5_CR61","doi-asserted-by":"publisher","first-page":"757","DOI":"10.1016\/j.scitotenv.2014.05.051","volume":"490","author":"F Amato","year":"2014","unstructured":"Amato F, Rivas I, Viana M, Moreno T, Bouso L, Reche C, \u00c0lvarez Pedrerol M, Alastuey A, Sunyer J, Querol X (2014) Sources of indoor and outdoor PM2.5 concentrations in primary schools. Sci Total Environ 490:757\u2013765. ISSN 0048 9697, https:\/\/doi.org\/10.1016\/j.scitotenv.2014.05.051","journal-title":"Sci Total Environ"},{"key":"5_CR62","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/j.atmosenv.2014.12.064","volume":"103","author":"SZ Sajani","year":"2015","unstructured":"Sajani SZ, Ricciardelli I, Trentini A, Bacco D, Maccone C, Castellazzi S, Lauriola P, Poluzzi V, Harrison RM (2015) Spatial and indoor, outdoor gradients in urban concentrations of ultrafine particles and PM2.5 mass and chemical components. Atmos Environ 103:307\u2013320. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/j.atmosenv.2014.12.064","journal-title":"Atmos Environ"},{"key":"5_CR63","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1016\/j.buildenv.2015.01.015","volume":"87","author":"NYY Razali","year":"2015","unstructured":"Razali NYY, Latif MT, Dominick D, Mohamad N, Sulaiman FR, Srithawirat T (2015) Concentration of particulate matter, CO and CO2 in selected schools in Malaysia. Build Environ 87:108\u2013116. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2015.01.015","journal-title":"Build Environ"},{"issue":"20","key":"5_CR64","doi-asserted-by":"publisher","first-page":"3463","DOI":"10.1016\/S1352-2310(01)00097-8","volume":"35","author":"L Morawska","year":"2001","unstructured":"Morawska L, He C, Hitchins J, Gilbert D, Parappukkaran S (2001) The relationship between indoor and outdoor airborne particles in the residential environment. Atmos Environ 35(20):3463\u20133473. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/S1352-2310(01)00097-8","journal-title":"Atmos Environ"},{"issue":"29","key":"5_CR65","doi-asserted-by":"publisher","first-page":"4121","DOI":"10.1016\/S1352-2310(03)00509-0","volume":"37","author":"CM N\u00ed Riain","year":"2003","unstructured":"N\u00ed Riain CM, Mark D, Davies M, Harrison RM, Byrne MA (2003) Averaging periods for indoor\u2013outdoor ratios of pollution in naturally ventilated non domestic buildings near a busy road. Atmos Environ 37(29):4121\u20134132. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/S1352-2310(03)00509-0","journal-title":"Atmos Environ"},{"key":"5_CR66","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1016\/j.proeng.2015.08.1076","volume":"121","author":"Y Wang","year":"2015","unstructured":"Wang Y, Chen C, Wang P, Wan Y, Chen Z, Zhao L (2015) Experimental Investigation on indoor, outdoor PM2.5 concentrations of an office building located in Guangzhou. Procedia Eng 121:333\u2013340. ISSN 1877 7058, https:\/\/doi.org\/10.1016\/j.proeng.2015.08.1076","journal-title":"Procedia Eng"},{"key":"5_CR67","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1016\/j.atmosenv.2012.10.050","volume":"65","author":"G Sangiorgi","year":"2013","unstructured":"Sangiorgi G, Ferrero L, Ferrini BS, Lo Porto C, Perrone MG, Zangrando R, Gambaro A, Lazzati Z, Bolzacchini E (2013) Indoor airborne particle sources and semi volatile partitioning effect of outdoor fine PM in offices. Atmos Environ 65:205\u2013214. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/j.atmosenv.2012.10.050","journal-title":"Atmos Environ"},{"key":"5_CR68","doi-asserted-by":"publisher","first-page":"372","DOI":"10.1016\/j.rser.2016.06.018","volume":"64","author":"Z Zhou","year":"2016","unstructured":"Zhou Z, Liu Y, Yuan J, Zuo J, Chen G, Linyu X, Rameezdeen R (2016) Indoor PM2.5 concentrations in residential buildings during a severely polluted winter: a case study in Tianjin, China. Renew Sustain Energy Rev 64:372\u2013381. ISSN 1364 0321, https:\/\/doi.org\/10.1016\/j.rser.2016.06.018","journal-title":"Renew Sustain Energy Rev"},{"key":"5_CR69","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1016\/j.buildenv.2014.08.019","volume":"82","author":"HJ Oh","year":"2014","unstructured":"Oh HJ, Nam IS, Yun H, Kim J, Yang J, Sohn JR (2014) Characterization of indoor air quality and efficiency of air purifier in childcare centers, Korea. Build Environ 82:203\u2013214. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2014.08.019","journal-title":"Build Environ"},{"key":"5_CR70","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1016\/j.buildenv.2015.05.018","volume":"92","author":"MF Theresa","year":"2015","unstructured":"Theresa MF, Lomboy C, Quirit LL, Molina VB, Dalmacion GV, Schwartz JD, Suh HH, Baja ES (2015) Characterization of particulate matter 2.5 in an urban tertiary care hospital in the Philippines. Build Environ 92:432\u2013439. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2015.05.018","journal-title":"Build Environ"},{"issue":"4","key":"5_CR71","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1016\/j.buildenv.2003.09.015","volume":"39","author":"CM Liao","year":"2004","unstructured":"Liao CM, Huang SJ, Hsin Yu (2004) Size dependent particulate matter indoor, outdoor relationships for a wind induced naturally ventilated airspace. Build Environ 39(4):411\u2013420. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2003.09.015","journal-title":"Build Environ"},{"issue":"10","key":"5_CR72","doi-asserted-by":"publisher","first-page":"2037","DOI":"10.1016\/j.buildenv.2009.02.010","volume":"44","author":"D Massey","year":"2009","unstructured":"Massey D, Masih J, Kulshrestha A, Habil M, Taneja A (2009) Indoor, outdoor relationship of fine particles less than 2.5 \u03bcm (PM2.5) in residential homes locations in central Indian region. Build Environ 44(10):2037\u20132045. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2009.02.010","journal-title":"Build Environ"},{"key":"5_CR73","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1016\/j.buildenv.2015.02.008","volume":"0360","author":"L Zhao","year":"2015","unstructured":"Zhao L, Chen C, Wang P, Chen Z, Cao S, Wang Q, Xie G, Wan Y, Wang Y, Bin L (2015) Influence of atmospheric fine particulate matter (PM2.5) pollution on indoor environment during winter in Beijing. Build Environ 0360:1323. https:\/\/doi.org\/10.1016\/j.buildenv.2015.02.008","journal-title":"Build Environ"},{"key":"5_CR74","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1016\/j.buildenv.2016.11.008","volume":"111","author":"R Jan","year":"2017","unstructured":"Jan R, Roy R, Suman Yadav P, Satsangi G (2017) Exposure assessment of children to particulate matter and gaseous species in school environments of Pune, India. Build Environ 111:207\u2013217. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2016.11.008","journal-title":"Build Environ"},{"key":"5_CR75","doi-asserted-by":"publisher","unstructured":"Saraga D, Pateraki S, Papadopoulos A, Vasilakos C, Maggos T (2011) Studying the indoor air quality in three non residential environments of different use: a museum, a printery industry and an office. Build Environ 46(11):2333\u20132341. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2011.05.013","DOI":"10.1016\/j.buildenv.2011.05.013"},{"key":"5_CR76","doi-asserted-by":"publisher","unstructured":"Rivas I, Viana M, Moreno T, Pandolfi M, Amato F, Reche C, Bouso L, \u00c0lvarez Pedrerol M, Alastuey A, Sunyer J, Querol X (2014) Child exposure to indoor and outdoor air pollutants in schools in Barcelona, Spain. Environ Int 69:200\u2013212. ISSN 0160 4120, https:\/\/doi.org\/10.1016\/j.envint.2014.04.009","DOI":"10.1016\/j.envint.2014.04.009"},{"issue":"5","key":"5_CR77","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1038\/jes.2015.3","volume":"25","author":"R Meier","year":"2015","unstructured":"Meier R, Eeftens M, Phuleria HC, Ineichen A, Corradi E, Davey M, Fierz M, Ducret RE, Stich IA, Schindler C, Rochat T, Hensch NP, Tsai MY, K\u00fcnzli N (2015) Differences in indoor versus outdoor concentrations of ultrafine particles, PM2.5, PMabsorbance and NO2 in Swiss homes. J Expos Sci Environ Epidemiol 25(5):499\u2013505. ISSN 1559 0631, https:\/\/doi.org\/10.1038\/jes.2015.3","journal-title":"J Expos Sci Environ Epidemiol"},{"key":"5_CR78","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1016\/j.buildenv.2014.05.032","volume":"80","author":"A Challoner","year":"2014","unstructured":"Challoner A, Gill L (2014) Indoor, outdoor air pollution relationships in ten commercial buildings: PM2.5 and NO2. Build Environ 80:159\u2013173. ISSN 0360 1323. https:\/\/doi.org\/10.1016\/j.buildenv.2014.05.032","journal-title":"Build Environ"},{"key":"5_CR79","doi-asserted-by":"publisher","first-page":"692","DOI":"10.1016\/j.proeng.2015.09.006","volume":"121","author":"H Jinhua","year":"2015","unstructured":"Jinhua H, Li N (2015) Variation of PM2.5 concentrations in shopping malls in Autumn, Changsha. Procedia Eng 121:692\u2013698. ISSN 1877 7058, https:\/\/doi.org\/10.1016\/j.proeng.2015.09.006","journal-title":"Procedia Eng"},{"issue":"15","key":"5_CR80","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1016\/j.enbuild.2017.05.061","volume":"149","author":"J Ren","year":"2017","unstructured":"Ren J, Liu J, Cao X, Hou Y (2017) Influencing factors and energy saving control strategies for indoor fine particles in commercial office buildings in six Chinese cities. Energy and Build 149(15):171\u2013179. ISSN 0378 7788, https:\/\/doi.org\/10.1016\/j.enbuild.2017.05.061","journal-title":"Energy and Build"},{"key":"5_CR81","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1016\/j.buildenv.2014.11.026","volume":"85","author":"CC Jung","year":"2015","unstructured":"Jung CC, Pei Chih W, Tseng CH, Huey Jen S (2015) Indoor air quality varies with ventilation types and working areas in hospitals. Build Environ 85:190\u2013195. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2014.11.026","journal-title":"Build Environ"},{"issue":"2","key":"5_CR82","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1007\/s12273-015-0266-z","volume":"9","author":"S Shi","year":"2016","unstructured":"Shi S, Zhao B (2016) Occupants\u2019 interactions with windows in 8 residential apartments in Beijing and Nanjing, China. Build Simul 9(2):221\u2013231. ISSN 1996 8744, https:\/\/doi.org\/10.1007\/s12273-015-0266-z","journal-title":"Build Simul"},{"issue":"3","key":"5_CR83","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1038\/jes.2013.1","volume":"23","author":"M Johnson","year":"2013","unstructured":"Johnson M, MacNeill M, Mannion AG, Nethery E, Xiaohong X, Dales R, Rasmussen P, Wheeler A (2013) Development of temporally refined land use regression models predicting daily household level air pollution in a panel study of lung function among asthmatic children. J Expo Sci Environ Epidemiol 23(3):259\u2013267. ISSN 1559 0631, https:\/\/doi.org\/10.1038\/jes.2013.1","journal-title":"J Expo Sci Environ Epidemiol"},{"key":"5_CR84","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1016\/j.buildenv.2012.10.013","volume":"60","author":"A Rackes","year":"2013","unstructured":"Rackes A, Waring MS (2013) Modeling impacts of dynamic ventilation strategies on indoor air quality of offices in six US cities. Build Environ 60:243\u2013253. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2012.10.013","journal-title":"Build Environ"},{"key":"5_CR85","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1016\/j.buildenv.2015.03.027","volume":"93","author":"ET Gall","year":"2015","unstructured":"Gall ET, Chen A, Chang VWC, Nazaroff WW (2015) Exposure to particulate matter and ozone of outdoor origin in Singapore. Build Environ 93:3\u201313. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2015.03.027","journal-title":"Build Environ"},{"issue":"33","key":"5_CR86","doi-asserted-by":"publisher","first-page":"6362","DOI":"10.1016\/j.atmosenv.2006.05.047","volume":"40","author":"C Dimitroulopoulou","year":"2006","unstructured":"Dimitroulopoulou C, Ashmore MR, Hill MTR, Byrne MA, Kinnersley R (2006) INDAIR: a probabilistic model of indoor air pollution in UK homes. Atmos Environ 40(33):6362\u20136379. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/j.atmosenv.2006.05.047","journal-title":"Atmos Environ"},{"key":"5_CR87","doi-asserted-by":"publisher","unstructured":"McGrath JA, Byrne MA, Ashmore MR, Terry AC, Dimitroulopoulou C (2014) A simulation study of the changes in PM2.5 concentrations due to interzonal airflow variations caused by internal door opening patterns. Atmos Environ 87:183\u2013188. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/j.atmosenv.2014.01.050","DOI":"10.1016\/j.atmosenv.2014.01.050"},{"key":"5_CR88","doi-asserted-by":"publisher","unstructured":"Li X, Yan Y, Shang Y, Tu J (2015) An Eulerian\u2013Eulerian model for particulate matter transport in indoor spaces. Build Environ 86:191\u2013202. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2015.01.010","DOI":"10.1016\/j.buildenv.2015.01.010"},{"issue":"9","key":"5_CR89","doi-asserted-by":"publisher","first-page":"966","DOI":"10.1016\/j.enbuild.2009.04.005","volume":"41","author":"HM Kao","year":"2009","unstructured":"Kao HM, Chang TJ, Hsieh YF, Wang CH, Hsieh CI (2009) Comparison of airflow and particulate matter transport in multi room buildings for different natural ventilation patterns. Energy Build 41(9):966\u2013974. ISSN 0378 7788, https:\/\/doi.org\/10.1016\/j.enbuild.2009.04.005","journal-title":"Energy Build"},{"key":"5_CR90","doi-asserted-by":"publisher","unstructured":"Zhang T, Tan Y, Zhang X, Li Z (2016) A glazed transpired solar wall system for improving indoor environment of rural buildings in northeast China. Build Environ 98:158\u2013179. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2016.01.011","DOI":"10.1016\/j.buildenv.2016.01.011"},{"issue":"9","key":"5_CR91","doi-asserted-by":"publisher","first-page":"3253","DOI":"10.1016\/j.buildenv.2006.08.015","volume":"42","author":"Alvin CK Lai","year":"2007","unstructured":"Lai Alvin CK, Chen FZ (2007) Modeling of cooking emitted particle dispersion and deposition in a residential flat: a real room application. Build Environ 42(9):3253\u20133260. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2006.08.015","journal-title":"Build Environ"},{"key":"5_CR92","doi-asserted-by":"publisher","unstructured":"Jurelionis A, Gagyt\u0117 L, Prasauskas T, \u010ciu\u017eas D, Krugly E, \u0160eduikyt\u0117 L, Martuzevi\u010dius D (2015) The impact of the air distribution method in ventilated rooms on the aerosol particle dispersion and removal: the experimental approach. Energy Build 86:305 313. ISSN 0378 7788, https:\/\/doi.org\/10.1016\/j.enbuild.2014.10.014","DOI":"10.1016\/j.enbuild.2014.10.014"},{"issue":"1","key":"5_CR93","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1007\/s12273-016-0313-4","volume":"10","author":"Yu Liu","year":"2017","unstructured":"Liu Yu, Li H, Feng G (2017) Simulation of inhalable aerosol particle distribution generated from cooking by Eulerian approach with RNG k\u2013epsilon turbulence model and pollution exposure in a residential kitchen space. Build Simul 10(1):135\u2013144. ISSN 1996 8744, https:\/\/doi.org\/10.1007\/s12273-016-0313-4","journal-title":"Build Simul"},{"issue":"1","key":"5_CR94","doi-asserted-by":"publisher","first-page":"320","DOI":"10.1016\/j.buildenv.2016.05.007","volume":"104","author":"TB David","year":"2016","unstructured":"David TB, Waring MS (2016) Impact of natural versus mechanical ventilation on simulated indoor air quality and energy consumption in offices in fourteen US cities. Build Environ 104(1):320\u2013336. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2016.05.007","journal-title":"Build Environ"},{"issue":"2","key":"5_CR95","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1007\/s12273-016-0323-2","volume":"10","author":"Y Liu","year":"2017","unstructured":"Liu Y, Cao Q, Liu W, Lin CH, Wei D, Baughcum S, Long Z, Shen X, Chen Q (2017) Numerical modeling of particle deposition in the environmental control systems of commercial airliners on ground. Build Simul 10(2):265\u2013275. ISSN 1996 8744, https:\/\/doi.org\/10.1007\/s12273-016-0323-2","journal-title":"Build Simul"},{"key":"5_CR96","doi-asserted-by":"publisher","unstructured":"Thatcher TL, Layton DW (1995) Deposition, resuspension, and penetration of particles within a residence. Atmos Environ 29(13):1487\u20131497. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/1352-2310(95)00016-R","DOI":"10.1016\/1352-2310(95)00016-R"},{"key":"5_CR97","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/jes.2016.52","volume":"7","author":"JM Gaffin","year":"2016","unstructured":"Gaffin JM, Petty CR, Hauptman M, Kang CM, Wolfson JM, Awad YA, Di Q, Lai PS, Sheehan WJ, Baxi S, Coull BA, Schwartz JD, Gold DR, Koutrakis P, Phipatanakul W (2016) Modeling indoor particulate exposures in inner city school classrooms. J Expo Sci Environ Epidemiol 7:1\u20137. ISSN 1559 064X, https:\/\/doi.org\/10.1038\/jes.2016.52","journal-title":"J Expo Sci Environ Epidemiol"},{"issue":"2","key":"5_CR98","doi-asserted-by":"publisher","first-page":"448","DOI":"10.1038\/jes.2012.34","volume":"22","author":"N Hodas","year":"2012","unstructured":"Hodas N, Meng Q, Lunden MM, Rich DQ, \u00d6zkaynak H, Baxter LK, Zhang Q, Turpin BJ (2012) Variability in the fraction of ambient fine particulate matter found indoors and observed heterogeneity in health effect estimates. J Expo Sci Environ Epidemiol 22(2):448\u2013454. ISSN 1559 0631, https:\/\/doi.org\/10.1038\/jes.2012.34","journal-title":"J Expo Sci Environ Epidemiol"},{"key":"5_CR99","doi-asserted-by":"crossref","unstructured":"Chen Z, Chen C, Wei S, Wu Y, Wang Y, Wan Y (2016) Impact of the external window crack structure on indoor PM2.5 mass concentration. Build Environ 108(1):240\u2013251. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2016.08.031","DOI":"10.1016\/j.buildenv.2016.08.031"},{"key":"5_CR100","doi-asserted-by":"publisher","unstructured":"Shi Y, Li X, Li H (2017) A new method to assess infiltration rates in large shopping centers. Build Environ 119:140\u2013152. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2017.04.011","DOI":"10.1016\/j.buildenv.2017.04.011"},{"key":"5_CR101","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1016\/j.buildenv.2015.04.006","volume":"90","author":"W Ji","year":"2015","unstructured":"Ji W, Zhao B (2015) Contribution of outdoor originating particles, indoor emitted particles and indoor secondary organic aerosol (SOA) to residential indoor PM2.5 concentration: a model based estimation. Build Environ 90:196\u2013205. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2015.04.006","journal-title":"Build Environ"},{"issue":"4","key":"5_CR102","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1007\/s12273-016-0340-1","volume":"10","author":"BH Lee","year":"2017","unstructured":"Lee BH, Yee SW, Kang DH, Yeo MS, Kim KW (2017) Multi zone simulation of outdoor particle penetration and transport in a multi story building. Build Simul 10(4):525\u2013534. ISSN 1996 8744, https:\/\/doi.org\/10.1007\/s12273-016-0340-1","journal-title":"Build Simul"},{"issue":"6","key":"5_CR103","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1016\/j.buildenv.2003.12.005","volume":"39","author":"Alvin CK Lai","year":"2004","unstructured":"Lai Alvin CK (2004) Modeling of airborne particle exposure and effectiveness of engineering control strategies. Build Environ 39(6):599\u2013610. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2003.12.005","journal-title":"Build Environ"},{"key":"5_CR104","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1016\/j.buildenv.2014.04.017","volume":"78","author":"P Das","year":"2014","unstructured":"Das P, Shrubsole C, Jones B, Hamilton I, Chalabi Z, Davies M, Mavrogianni A, Taylor J (2014) Using probabilistic sampling based sensitivity analyses for indoor air quality modelling. Build Environ 78:171\u2013182. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2014.04.017","journal-title":"Build Environ"},{"key":"5_CR105","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1016\/j.buildenv.2013.03.021","volume":"66","author":"P Das","year":"2013","unstructured":"Das P, Chalabi Z, Jones B, Milner J, Shrubsole C, Davies M, Hamilton I, Ridley I, Wilkinson P (2013) Multi objective methods for determining optimal ventilation rates in dwellings. Build Environ 66:72\u201381. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2013.03.021","journal-title":"Build Environ"},{"issue":"8","key":"5_CR106","doi-asserted-by":"publisher","first-page":"1605","DOI":"10.1016\/j.enbuild.2008.02.007","volume":"40","author":"T Marsik","year":"2008","unstructured":"Marsik T, Johnson R (2008) Use of Simulink to evaluate the air quality and energy performance of HRV equipped residences in Fairbanks, Alaska. Energy Build 40(8):1605\u20131613. ISSN 0378 7788, https:\/\/doi.org\/10.1016\/j.enbuild.2008.02.007","journal-title":"Energy Build"},{"key":"5_CR107","doi-asserted-by":"publisher","unstructured":"Marsik T, Johnson R (2008) HVAC air quality model and its use to test a PM2.5 control strategy. Build Environ 43(11):1850\u20131857. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2007.11.001","DOI":"10.1016\/j.buildenv.2007.11.001"},{"key":"5_CR108","doi-asserted-by":"publisher","unstructured":"Taylor J, Shrubsole C, Davies M, Biddulph P, Das P, Hamilton I, Vardoulakis S, Mavrogianni A, Jones B, Oikonomou E (2014) The modifying effect of the building envelope on population exposure to PM2.5 from outdoor sources. Indoor Air 24(6), 639\u2013651. ISSN 1600 0668, https:\/\/doi.org\/10.1111\/ina.12116","DOI":"10.1111\/ina.12116"},{"key":"5_CR109","doi-asserted-by":"publisher","unstructured":"Martins NR, da Gra\u00e7a GC (2017) Impact of outdoor PM2.5 on natural ventilation usability in California\u2019s nondomestic buildings. Appl Energy 189:711\u2013724. ISSN 0306 2619, https:\/\/doi.org\/10.1016\/j.apenergy.2016.12.103","DOI":"10.1016\/j.apenergy.2016.12.103"},{"key":"5_CR110","doi-asserted-by":"publisher","unstructured":"Martins NR, da Gra\u00e7a GC, Simulation of the effect of fine particle pollution on the potential for natural ventilation of non domestic buildings in European cities. Build Environ 115:236\u2013250. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2017.01.030","DOI":"10.1016\/j.buildenv.2017.01.030"},{"key":"5_CR111","doi-asserted-by":"publisher","unstructured":"Martins NR, da Gra\u00e7a GC (2018) Effects of airborne fine particle pollution on the usability of natural ventilation in office buildings in three megacities in Asia. Renew Energy 117:357\u2013373. ISSN 0960 1481, https:\/\/doi.org\/10.1016\/j.renene.2017.10.089","DOI":"10.1016\/j.renene.2017.10.089"},{"key":"5_CR112","doi-asserted-by":"publisher","unstructured":"Luo J, Du P, Samat A, Xia J, Che M, Xue Z (2017) Spatiotemporal pattern of PM2.5 concentrations in mainland china and analysis of its influencing factors using geographically weighted regression. Sci Rep 7, Article Number 40607. ISSN 2045 2322, https:\/\/doi.org\/10.1038\/srep40607","DOI":"10.1038\/srep40607"},{"key":"5_CR113","doi-asserted-by":"publisher","unstructured":"Liang CS, Duan FK, He KB, Ma YL (2016) Review on recent progress in observations, source identifications and countermeasures of PM2.5. Environ Int 86:150\u2013170. ISSN 0160 4120, https:\/\/doi.org\/10.1016\/j.envint.2015.10.016","DOI":"10.1016\/j.envint.2015.10.016"},{"key":"5_CR114","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1016\/j.atmosenv.2016.08.072","volume":"144","author":"BM Kim","year":"2016","unstructured":"Kim BM, Seo J, Kim JY, Lee JY, Kim Y (2016) Transported versus local contributions from secondary and biomass burning sources to PM2.5. Atmos Environ 144:24\u201336. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/j.atmosenv.2016.08.072","journal-title":"Atmos Environ"},{"key":"5_CR115","doi-asserted-by":"publisher","first-page":"570","DOI":"10.1016\/j.rser.2016.01.093","volume":"60","author":"BQ He","year":"2016","unstructured":"He BQ (2016) Advances in emission characteristics of diesel engines using different biodiesel fuels. Renew Sustain Energy Rev 60:570\u2013586. ISSN 1364 0321, https:\/\/doi.org\/10.1016\/j.rser.2016.01.093","journal-title":"Renew Sustain Energy Rev"},{"key":"5_CR116","doi-asserted-by":"publisher","first-page":"785","DOI":"10.1016\/j.rser.2015.06.053","volume":"51","author":"MI Khan","year":"2015","unstructured":"Khan MI, Yasmin T, Shakoor A (2015) Technical overview of compressed natural gas (CNG) as a transportation fuel. Renew Sustain Energy Rev 51:785\u2013797. ISSN 1364 0321, https:\/\/doi.org\/10.1016\/j.rser.2015.06.053","journal-title":"Renew Sustain Energy Rev"},{"key":"5_CR117","doi-asserted-by":"publisher","unstructured":"Han X, Guo Q, Liu C, Strauss H, Yang J, Hu J, Wei R, Tian L, Kong J, Peters M (2016) Effect of the pollution control measures on PM2.5 during the 2015 China Victory Day Parade: implication from water soluble ions and sulfur isotope. Environ Pollut 218:230\u2013241. ISSN 0269 7491, https:\/\/doi.org\/10.1016\/j.envpol.2016.06.038","DOI":"10.1016\/j.envpol.2016.06.038"},{"key":"5_CR118","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1016\/j.envpol.2015.09.006","volume":"208","author":"L Chen","year":"2016","unstructured":"Chen L, Liu C, Zou R, Yang M, Zhang Z (2016) Experimental examination of effectiveness of vegetation as bio filter of particulate matters in the urban environment. Environ Pollut 208:198\u2013208. ISSN 0269 7491, https:\/\/doi.org\/10.1016\/j.envpol.2015.09.006","journal-title":"Environ Pollut"},{"key":"5_CR119","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1016\/j.envpol.2015.02.026","volume":"201","author":"Z Tong","year":"2015","unstructured":"Tong Z, Whitlow TH, MacRae PF, Landers AJ, Harada Y (2015) Quantifying the effect of vegetation on near road air quality using brief campaigns. Environ Pollu 201:141\u2013149. ISSN 0269 7491, https:\/\/doi.org\/10.1016\/j.envpol.2015.02.026","journal-title":"Environ Pollu"},{"issue":"3","key":"5_CR120","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1007\/s12273-016-0324-1","volume":"10","author":"X Jin","year":"2017","unstructured":"Jin X, Yang L, Xiaoze D, Yang Y (2017) Transport characteristics of PM2.5 inside urban street canyons: the effects of trees and vehicles. Build Simul 10(3):337\u2013350. ISSN 1996 8744, https:\/\/doi.org\/10.1007\/s12273-016-0324-1","journal-title":"Build Simul"},{"key":"5_CR121","doi-asserted-by":"publisher","unstructured":"Chen Y, Schleicher N, Fricker M, Cen K, Liu XL, Kaminski U, Yu Y, Wu XF, Norra S (2016) Long term variation of black carbon and PM2.5 in Beijing, China with respect to meteorological conditions and governmental measures. Environ Pollu, 212:269\u2013278. ISSN 0269 7491, https:\/\/doi.org\/10.1016\/j.envpol.2016.01.008","DOI":"10.1016\/j.envpol.2016.01.008"},{"key":"5_CR122","doi-asserted-by":"publisher","unstructured":"Zhang YL, Cao F (2015) Fine particulate matter (PM2.5) in China at a city level. Sci Rep 5, Article Number 14884. ISSN 2045 2322, https:\/\/doi.org\/10.1038\/srep23604","DOI":"10.1038\/srep23604"},{"key":"5_CR123","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1016\/j.envpol.2013.01.002","volume":"175","author":"RM Qadir","year":"2013","unstructured":"Qadir RM, Abbaszade G, Schnelle Kreis J, Chow JC, Zimmermann R (2013) Concentrations and source contributions of particulate organic matter before and after implementation of a low emission zone in Munich, Germany. Environ Pollu 175:158\u2013167. ISSN 0269 7491, https:\/\/doi.org\/10.1016\/j.envpol.2013.01.002","journal-title":"Environ Pollu"},{"key":"5_CR124","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1016\/j.envpol.2014.06.012","volume":"193","author":"S Hasheminassab","year":"2014","unstructured":"Hasheminassab S, Daher N, Ostro BD, Sioutas C (2014) Long term source apportionment of ambient fine particulate matter (PM2.5) in the Los Angeles Basin: a focus on emissions reduction from vehicular sources. Environ Pollu 193:54\u201364. ISSN 0269 7491, https:\/\/doi.org\/10.1016\/j.envpol.2014.06.012","journal-title":"Environ Pollu"},{"key":"5_CR125","doi-asserted-by":"publisher","unstructured":"Grabow ML, Spak SN, Holloway T, Stone Jr B, Mednick AC, Patz JA (2012) Air quality and exercise related health benefits from reduced car travel in the midwestern United States. Environ Health Perspect 120(1):68\u201376. ISSN 0091 6765, https:\/\/doi.org\/10.1289\/ehp.1103440","DOI":"10.1289\/ehp.1103440"},{"key":"5_CR126","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1016\/j.envpol.2015.09.010","volume":"208","author":"S Shu","year":"2016","unstructured":"Shu S, Batteate C, Cole B, Froines J, Zhu Y (2016) Air quality impacts of a CicLAvia event in Downtown Los Angeles, CA. Environ Pollu 208:170\u2013176. https:\/\/doi.org\/10.1016\/j.envpol.2015.09.010","journal-title":"Environ Pollu"},{"issue":"8","key":"5_CR127","doi-asserted-by":"publisher","first-page":"2016","DOI":"10.1016\/j.envpol.2011.02.033","volume":"159","author":"TH Whitlow","year":"2011","unstructured":"Whitlow TH, Andrew Hall K, Zhang M, Anguita J (2011) Impact of local traffic exclusion on near road air quality: findings from the New York City \u201cSummer Streets\u201d campaign. Environ Pollu 159(8):2016\u20132027. ISSN 0269 7491, https:\/\/doi.org\/10.1016\/j.envpol.2011.02.033","journal-title":"Environ Pollu"},{"key":"5_CR128","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1016\/j.atmosenv.2015.08.087","volume":"120","author":"F Karagulian","year":"2015","unstructured":"Karagulian F, Belis CA, Carlos FC, Dora AM, Ust\u00fcn P, Bonjour S, Rohani HA, Amann M (2015) Contributions to cities\u2019 ambient particulate matter (PM): a systematic review of local source contributions at global level. Atmos Environ 120:475\u2013483. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/j.atmosenv.2015.08.087","journal-title":"Atmos Environ"},{"key":"5_CR129","doi-asserted-by":"publisher","unstructured":"Shuangchen M, Jin C, Gongda C, Weijing Y, Sijie Z (2016) Research on desulfurization wastewater evaporation: Present and future perspectives. Renew Sustain Energy Rev 58:1143\u20131151. ISSN 1364 0321, https:\/\/doi.org\/10.1016\/j.rser.2015.12.252","DOI":"10.1016\/j.rser.2015.12.252"},{"issue":"1","key":"5_CR130","doi-asserted-by":"publisher","first-page":"658","DOI":"10.1016\/j.enbuild.2016.06.010","volume":"127","author":"RL Carvalho","year":"2016","unstructured":"Carvalho RL, Jensen OM, Tarelho Lu\u00eds AC (2016) Mapping the performance of wood burning stoves by installations worldwide. Energy Build 127(1):658\u2013679. ISSN 0378 7788, https:\/\/doi.org\/10.1016\/j.enbuild.2016.06.010","journal-title":"Energy Build"},{"key":"5_CR131","doi-asserted-by":"publisher","unstructured":"Islam A, Chan ES, Yap YHT, Mondal MdAH, Moniruzzaman M, Mridha M (2014) Energy security in Bangladesh perspective\u2014an assessment and implication. Renew Sustain Energy Rev 32:154\u2013171. ISSN 1364 0321, https:\/\/doi.org\/10.1016\/j.rser.2014.01.021","DOI":"10.1016\/j.rser.2014.01.021"},{"issue":"4","key":"5_CR132","doi-asserted-by":"publisher","first-page":"535","DOI":"10.1007\/s12273-016-0341-0","volume":"10","author":"MA Torkmahalleh","year":"2017","unstructured":"Torkmahalleh MA, Kaibaldiyeva U, Kadyrbayeva A (2017) A new computer model for the simulation of particulate matter formation from heated cooking oils using Aspen Plus. Build Simul 10(4):535\u2013550. ISSN 1996 8744, https:\/\/doi.org\/10.1007\/s12273-016-0341-0","journal-title":"Build Simul"},{"key":"5_CR133","doi-asserted-by":"publisher","first-page":"2310","DOI":"10.1016\/j.atmosenv.2013.03.038","volume":"74","author":"M Amouei Torkmahalleh","year":"2013","unstructured":"Amouei Torkmahalleh M, Zhao Y, Hopke PK, Rossner A, Ferro AR (2013) Additive impacts on particle emissions from heating low emitting cooking oils. Atmos Environ 74:2310. https:\/\/doi.org\/10.1016\/j.atmosenv.2013.03.038","journal-title":"Atmos Environ"},{"key":"5_CR134","doi-asserted-by":"publisher","unstructured":"Yan XD, Wang QM, Tie C, Jin HT, Han YX, Zhang JL, Yu XM, Hou Q, Zhang PP, Wang AP, Zhang PC, Gao Z, Jiang JD (2017) Polydatin protects the respiratory system from PM2.5 exposure. Sci Rep 7, Article Number 40030. ISSN 2045 2322, https:\/\/doi.org\/10.1038\/srep40030","DOI":"10.1038\/srep40030"},{"key":"5_CR135","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1016\/j.envpol.2017.04.033","volume":"227","author":"N Zhang","year":"2017","unstructured":"Zhang N, Han B, He F, Jia X, Zhao R, Zhang Y, Bai Z (2017) Chemical characteristic of PM2.5 emission and inhalational carcinogenic risk of domestic Chinese cooking. Environ Pollu 227:24\u201330. https:\/\/doi.org\/10.1016\/j.envpol.2017.04.033","journal-title":"Environ Pollu"},{"key":"5_CR136","doi-asserted-by":"crossref","unstructured":"Johnston J, Counsell J, Strachan PA (2011) Trends in office internal gains and the impact on space heating and cooling, CIBSE Technical Symposium, DeMontfort University, Leicester, UK. https:\/\/strathprints.strath.ac.uk\/id\/eprint\/39288","DOI":"10.3943\/2011.0021"},{"key":"5_CR137","doi-asserted-by":"publisher","unstructured":"M\u00f8lgaard B, Koivisto AJ, Hussein T, H\u00e4meri K (2014) A new clean air delivery rate test applied to five portable indoor air cleaners. Aerosol Sci Technol 48(4):409\u2013417. ISSN 0278 6826, https:\/\/doi.org\/10.1080\/02786826.2014.883063","DOI":"10.1080\/02786826.2014.883063"},{"key":"5_CR138","doi-asserted-by":"publisher","unstructured":"Ma H, Shen H, Shui T, Li Q, Zhou L (2016) Experimental study on ultrafine particle removal performance of portable air cleaners with different filters in an office room. Int J Environ Res Publ Health 13, Number 1, Article Number 102. ISSN 1660 4601, https:\/\/doi.org\/10.3390\/ijerph13010102","DOI":"10.3390\/ijerph13010102"},{"key":"5_CR139","doi-asserted-by":"publisher","unstructured":"Vyas S, Srivastav N, Spears D (2016) An experiment with air purifiers in Delhi during winter 2015. PLoS ONE 11(12), Article Number e0167999. ISSN 1932 6203, https:\/\/doi.org\/10.1371\/journal.pone.0167999","DOI":"10.1371\/journal.pone.0167999"},{"issue":"4","key":"5_CR140","doi-asserted-by":"publisher","first-page":"659","DOI":"10.1177\/1420326X12460254","volume":"22","author":"M Ongwandee","year":"2013","unstructured":"Ongwandee M, Kruewan A (2013) Evaluation of portable household and in car air cleaners for air cleaning potential and ozone initiated pollutants. Indoor Built Environ 22(4):659\u2013668. ISSN 1420 326X, https:\/\/doi.org\/10.1177\/1420326X12460254","journal-title":"Indoor Built Environ"},{"key":"5_CR141","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1016\/j.buildenv.2013.11.020","volume":"73","author":"MP Spilak","year":"2014","unstructured":"Spilak MP, Karottki GD, Kolarik B, Frederiksen M, Loft S, Gunnarsen L (2014) Evaluation of building characteristics in 27 dwellings in Denmark and the effect of using particle filtration units on PM2.5 concentrations. Build Environ 73:55\u201363. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2013.11.020","journal-title":"Build Environ"},{"key":"5_CR142","doi-asserted-by":"publisher","unstructured":"Hart JF, Ward TJ, Spear TM, Rossi RJ, Holland NN, Loushin BG (2011) Evaluating the effectiveness of a commercial portable air purifier in homes with wood burning stoves: a preliminary study. J Environ Public Health 2011: Article Number 324809. ISSN 1687 9813, https:\/\/doi.org\/10.1155\/2011\/324809","DOI":"10.1155\/2011\/324809"},{"issue":"8","key":"5_CR143","doi-asserted-by":"publisher","first-page":"1177","DOI":"10.1177\/1420326X13501097","volume":"23","author":"SR Ardkapan","year":"2014","unstructured":"Ardkapan SR, Afshari A, Bergs\u00f8e NC, Nielsen PV (2014) Evaluation of air cleaning technologies existing in the Danish market: experiments in a duct and in a test room. Indoor Built Environ 23(8):1177\u20131186. https:\/\/doi.org\/10.1177\/1420326X13501097","journal-title":"Indoor Built Environ"},{"issue":"1","key":"5_CR144","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/j.enbuild.2016.03.027","volume":"119","author":"KC Noh","year":"2016","unstructured":"Noh KC, Yook SJ (2016) Evaluation of clean air delivery rates and operating cost effectiveness for room air cleaner and ventilation system in a small lecture room. Energy Build 119(1):111\u2013118. ISSN 0378 7788, https:\/\/doi.org\/10.1016\/j.enbuild.2016.03.027","journal-title":"Energy Build"},{"issue":"5","key":"5_CR145","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1038\/sj.jes.7500640","volume":"18","author":"P Barn","year":"2015","unstructured":"Barn P, Larson T, Noullett M, Kennedy S, Copes R, Brauer M (2015) Infiltration of forest fire and residential wood smoke: an evaluation of air cleaner effectiveness. J Expo Sci Environ Epidemiol 18(5):503\u2013511. ISSN 1559 0631, https:\/\/doi.org\/10.1038\/sj.jes.7500640","journal-title":"J Expo Sci Environ Epidemiol"},{"key":"5_CR146","doi-asserted-by":"publisher","unstructured":"Siegel JA (2016) Primary and secondary consequences of indoor air cleaners. Indoor Air 88(1):88\u201396. ISSN 1600 0668, https:\/\/doi.org\/10.1111\/ina.12194","DOI":"10.1111\/ina.12194"},{"key":"5_CR147","doi-asserted-by":"publisher","unstructured":"Irga PJ, Paull NJ, Abdo P, Torpy FR (2017) An assessment of the atmospheric particle removal efficiency of an in room botanical biofilter system, Build Environ 115:281\u2013290. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2017.01.035","DOI":"10.1016\/j.buildenv.2017.01.035"},{"key":"5_CR148","doi-asserted-by":"publisher","unstructured":"Zhang T (Tim), Wang S, Sun G, Xu L, Takaoka D (2010) Flow impact of an air conditioner to portable air cleaning. Build Environ 45(9):2047\u20132056. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2009.11.006","DOI":"10.1016\/j.buildenv.2009.11.006"},{"issue":"1","key":"5_CR149","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1007\/s12273-016-0310-7","volume":"10","author":"L Chen","year":"2017","unstructured":"Chen L, Jin X, Yang L, Xiaoze D, Yang Y (2017) Particle transport characteristics in indoor environment with an air cleaner: the effect of nonuniform particle distributions. Build Simul 10(1):123\u2013133. ISSN 1996 8744, https:\/\/doi.org\/10.1007\/s12273-016-0310-7","journal-title":"Build Simul"},{"issue":"6","key":"5_CR150","doi-asserted-by":"publisher","first-page":"987","DOI":"10.1177\/1420326X15592253","volume":"25","author":"X Jin","year":"2016","unstructured":"Jin X, Yang L, Xiaoze D, Yang Y (2016) Particle transport characteristics in indoor environment with an air cleaner. Indoor Built Environ 25(6):987\u2013996. ISSN 1420 326X, https:\/\/doi.org\/10.1177\/1420326X15592253","journal-title":"Indoor Built Environ"},{"issue":"1","key":"5_CR151","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1038\/jes.2012.85","volume":"23","author":"M Hatzopoulou","year":"2013","unstructured":"Hatzopoulou M, Weichenthal S, Dugum H, Pickett G, Moreno LM, Kulka R, Andersen R, Goldberg M (2013) The impact of traffic volume, composition, and road geometry on personal air pollution exposures among cyclists in Montreal, Canada. J Expo Sci Environ Epidemiol 23(1):46\u201351. ISSN 1559 0631, https:\/\/doi.org\/10.1038\/jes.2012.85","journal-title":"J Expo Sci Environ Epidemiol"},{"issue":"6","key":"5_CR152","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1038\/jes.2014.56","volume":"25","author":"RE Arku","year":"2015","unstructured":"Arku RE, Dionisio KL, Hughes AF, Vallarino J, Spengler JD, Castro MC, Mensah SA, Ezzati M (2015) Personal particulate matter exposures and locations of students in four neighborhoods in Accra, Ghana. J Expo Sci Environ Epidemiol 25(6):557\u2013566. ISSN 1559 0631, https:\/\/doi.org\/10.1038\/jes.2014.56","journal-title":"J Expo Sci Environ Epidemiol"},{"key":"5_CR153","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1016\/j.buildenv.2015.10.008","volume":"94","author":"ZT Ai","year":"2015","unstructured":"Ai ZT, Mak CM (2015) From street canyon microclimate to indoor environmental quality in naturally ventilated urban buildings: issues and possibilities for improvement. Build Environ Part 2 94:489\u2013503. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2015.10.008","journal-title":"Build Environ Part 2"},{"key":"5_CR154","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1016\/j.buildenv.2013.07.003","volume":"68","author":"F Noris","year":"2013","unstructured":"Noris F, Adamkiewicz G, Delp WW, Hotchi T, Russell M, Singer BC, Spears M, Vermeer K, Fisk WJ (2013) Indoor environmental quality benefits of apartment energy retrofits. Build Environ 68:170\u2013178. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2013.07.003","journal-title":"Build Environ"},{"key":"5_CR155","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1016\/j.buildenv.2015.03.010","volume":"89","author":"MS Zuraimi","year":"2015","unstructured":"Zuraimi MS, Tan Z (2015) Impact of residential building regulations on reducing indoor exposures to outdoor PM2.5 in Toronto. Build Environ 89:336\u2013344. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2015.03.010","journal-title":"Build Environ"},{"key":"5_CR156","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1016\/j.buildenv.2016.08.004","volume":"107","author":"Q Cao","year":"2015","unstructured":"Cao Q, Chen A, Zhou J, Chang VWC (2015) Performance evaluation of filter applications in fan coil units during the Southeast Asian haze episode. Build Environ 107:191\u2013197. ISSN 0360 1323. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2016.08.004","journal-title":"Build Environ"},{"issue":"3","key":"5_CR157","doi-asserted-by":"publisher","first-page":"718","DOI":"10.1016\/j.buildenv.2009.08.009","volume":"45","author":"A Shehabi","year":"2010","unstructured":"Shehabi A, Ganguly S, Gundel LA, Horvath A, Kirchstetter TW, Lunden MM, Tschudi W, Gadgil AJ, Nazaroff WW (2010) Can combining economizers with improved filtration save energy and protect equipment in data centers? Build Environ 45(3):718\u2013728. https:\/\/doi.org\/10.1016\/j.buildenv.2009.08.009","journal-title":"Build Environ"},{"key":"5_CR158","doi-asserted-by":"publisher","first-page":"643","DOI":"10.1016\/j.enbuild.2012.01.001","volume":"47","author":"JF Montgomery","year":"2012","unstructured":"Montgomery JF, Green SI, Rogak SN, Bartlett K (2012) Predicting the energy use and operation cost of HVAC air filters. Energy Build 47:643\u2013650. ISSN 0378 7788, https:\/\/doi.org\/10.1016\/j.enbuild.2012.01.001","journal-title":"Energy Build"},{"key":"5_CR159","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1016\/j.buildenv.2013.12.010","volume":"73","author":"M Zaatari","year":"2014","unstructured":"Zaatari M, Novoselac A, Siegel J (2014) The relationship between filter pressure drop, indoor air quality, and energy consumption in rooftop HVAC units. Build Environ 73:151\u2013161. https:\/\/doi.org\/10.1016\/j.buildenv.2013.12.010","journal-title":"Build Environ"},{"key":"5_CR160","doi-asserted-by":"publisher","unstructured":"Lu H, Lu L (2015) Numerical investigation on particle deposition enhancement in duct air flow by ribbed wall. Build Environ 85:61\u201372. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2014.11.031","DOI":"10.1016\/j.buildenv.2014.11.031"},{"key":"5_CR161","doi-asserted-by":"publisher","unstructured":"Lu H, Lu L (2015) A numerical study of particle deposition in ribbed duct flow with different rib shapes. Build Environ 94, Part 1:43 53. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2015.07.030","DOI":"10.1016\/j.buildenv.2015.07.030"},{"key":"5_CR162","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1016\/j.jweia.2016.10.008","volume":"159","author":"B Blocken","year":"2016","unstructured":"Blocken B, Vervoort R, van Hooff T (2016) Reduction of outdoor particulate matter concentrations by local removal in semi enclosed parking garages: apreliminary case study for Eindhoven city center. J Wind Eng Ind Aerodyn 159:80\u201398. ISSN 0167 6105, https:\/\/doi.org\/10.1016\/j.jweia.2016.10.008","journal-title":"J Wind Eng Ind Aerodyn"},{"key":"5_CR163","doi-asserted-by":"publisher","unstructured":"Araji MT, Ray SD, Leung L (2017) Pilot study on airborne PM2.5 filtration with particle accelerated collision technology in office environments. Sustain Cities Soc 28:101\u2013107. ISSN 2210 6707, https:\/\/doi.org\/10.1016\/j.scs.2016.08.023","DOI":"10.1016\/j.scs.2016.08.023"},{"key":"5_CR164","doi-asserted-by":"publisher","unstructured":"Liu C, Hsu PC, Lee HW, Ye M, Zheng G, Liu N, Li W, Cui Y (2015) Transparent air filter for high efficiency PM2.5 capture. Nat Commun 6, Article Number 6205. ISSN 2041 1723, https:\/\/doi.org\/10.1038\/ncomms7205","DOI":"10.1038\/ncomms7205"},{"key":"5_CR165","doi-asserted-by":"publisher","unstructured":"Zhao X, Wang S, Yin X, Yu J, Ding B (2016) Slip effect functional air filter for efficient purification of PM2.5. Sci Rep 6, Article Number 35472. ISSN 2045 2322, https:\/\/doi.org\/10.1038\/srep35472","DOI":"10.1038\/srep35472"},{"issue":"5","key":"5_CR166","doi-asserted-by":"publisher","first-page":"1401","DOI":"10.1109\/TDEI.2011.6032808","volume":"18","author":"J Podli\u0144ski","year":"2011","unstructured":"Podli\u0144ski J, Niewulis A, Shapoval V, Mizeraczyk J (2011) Electrohydrodynamic Secondary Flow and Particle Collection Efficiency in a One sided Spike plate Type Electrostatic Precipitator. IEEE Trans Dielectr Electr Insul 18(5):1401\u20131407. ISSN 1070 9878, https:\/\/doi.org\/10.1109\/TDEI.2011.6032808","journal-title":"IEEE Trans Dielectr Electr Insul"},{"issue":"5","key":"5_CR167","doi-asserted-by":"publisher","first-page":"1481","DOI":"10.1109\/TDEI.2013.6633674","volume":"20","author":"J Podli\u0144ski","year":"2013","unstructured":"Podli\u0144ski J, Berendt A, Mizeraczyk J (2013) Electrohydrodynamic secondary flow and particle collection efficiency in spike plate multi electrode electrostatic precipitator. IEEE Trans Dielectr Electr Insul 20(5):1481\u20131488. https:\/\/doi.org\/10.1109\/TDEI.2013.6633674","journal-title":"IEEE Trans Dielectr Electr Insul"},{"issue":"3","key":"5_CR168","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1016\/j.elstat.2005.06.006","volume":"64","author":"J Podli\u0144ski","year":"2006","unstructured":"Podli\u0144ski J, Dekowski J, Mizeraczyk J, Brocilo D, Chang JS (2006) Electrohydrodynamic gas flow in a positive polarity wire plate electrostatic precipitator and the related dust particle collection efficiency. J Electrost 64(3):259\u2013262. https:\/\/doi.org\/10.1016\/j.elstat.2005.06.006","journal-title":"J Electrost"},{"key":"5_CR169","doi-asserted-by":"publisher","unstructured":"Tokarek S, Bernis A (2006) An exemple of particle concentration reduction in parisian subway stations by electrostatic precipitation. Environ Technol 27(11):1279\u20131288. ISSN 0959 3330, https:\/\/doi.org\/10.1080\/09593332708618746","DOI":"10.1080\/09593332708618746"},{"issue":"2","key":"5_CR170","doi-asserted-by":"publisher","first-page":"1391","DOI":"10.1109\/TIA.2013.2272607","volume":"50","author":"SM Remaoun","year":"2014","unstructured":"Remaoun SM, Miloua F, Hammadi N, Zouzou N, Dascalescu L (2014) Optimization of a cost effective \u201cWire Plate\u201d type ESP for installation in a medical waste incinerator. IEEE Trans Ind Appl 50(2):1391\u20131396. ISSN 0093 9994, https:\/\/doi.org\/10.1109\/TIA.2013.2272607","journal-title":"IEEE Trans Ind Appl"},{"key":"5_CR171","doi-asserted-by":"publisher","unstructured":"Farnoosh N, Castle GSP, Adamiak K (2011) A 3D simulation of a single section electrostatic precipitator for dust particles removal. In: 2011 24th Canadian conference on electrical and computer engineering (CCECE), Niagara Falls, ON, Canada, 8\u201311 May 2011, pp 749\u2013752. ISSN 0840 7789, https:\/\/doi.org\/10.1109\/CCECE.2011.6030555","DOI":"10.1109\/CCECE.2011.6030555"},{"issue":"3","key":"5_CR172","doi-asserted-by":"publisher","first-page":"697","DOI":"10.1002\/ep.12052","volume":"34","author":"J Zhang","year":"2015","unstructured":"Zhang J, Dacheng X, Ren J, Helen W, Pan W (2015) Modeling and simulation of PM2.5 collection efficiency in a wire plate ESP subjected to magnetic field and diffusion charging. Environ Progress Sustain Energy 34(3):697\u2013702. https:\/\/doi.org\/10.1002\/ep.12052 https:\/\/doi.org\/10.1002\/ep.12052","journal-title":"Environ Progress Sustain Energy"},{"key":"5_CR173","doi-asserted-by":"publisher","unstructured":"Martins NR, da Gra\u00e7a GC (2017) Simulation of the effect of fine particle pollution on the potential for natural ventilation of non domestic buildings in European cities. Build Environ 115:236\u2013250. ISSN 0360 1323, https:\/\/doi.org\/10.1016\/j.buildenv.2017.01.030","DOI":"10.1016\/j.buildenv.2017.01.030"},{"key":"5_CR174","doi-asserted-by":"publisher","unstructured":"Haves P, Linden PF, da Gra\u00e7a GC (2004) Use of simulation in the design of a large, naturally ventilated office building. Build Serv Eng Res Technol 25(3):211\u2013221. ISSN 0143 6244. https:\/\/doi.org\/10.1191\/0143624404bt102oa","DOI":"10.1191\/0143624404bt102oa"},{"key":"5_CR175","unstructured":"Descloitres J (2004) NASA Visible Earth: California and Nevada, MODIS Rapid Response Team, NASA\/GSFC, 3 May 2004. https:\/\/visibleearth.nasa.gov\/view.php?id=59834"},{"key":"5_CR176","unstructured":"NASA\/JPL Caltech (2002) PIA03445: Dusty Skies over Southern California, NASA\/GSFC\/LaRC\/JPL, MISR Team, 20 Feb 2002. https:\/\/photojournal.jpl.nasa.gov\/catalog\/PIA03445"},{"key":"5_CR177","unstructured":"United States Census Bureau (2010) United States 2010 Census\u2014Total Population, through American FactFinder. https:\/\/factfinder.census.gov\/faces\/nav\/jsf\/pages\/searchresults.xhtml. Accessed 5 Nov 2015"},{"key":"5_CR178","doi-asserted-by":"publisher","unstructured":"Cheng Z, Luo L, Wang S, Wang Y, Sharma S, Shimadera H, Wang X, Bressi M, de Miranda RM, Jiang J, Zhou W, Fajardo O, Yan N, Hao J (2016) Status and characteristics of ambient PM2.5 pollution in global megacities. Environ Int 89\u201390:212\u2013221. ISSN 0160 4120, https:\/\/doi.org\/10.1016\/j.envint.2016.02.003","DOI":"10.1016\/j.envint.2016.02.003"},{"key":"5_CR179","unstructured":"Rodr\u00edguez HR, da Silva AS, Sangrador JLT, Banda GLM (2016) Air pollution management and control in Latin America and the Caribbean: implications for climate change. Revista Panamericana de Salud P\u00fablica, 40(3):150\u2013159. ISSN 1680 5348, http:\/\/www.scielosp.org\/pdf\/rpsp\/v40n3\/1020-4989-RPSP-40-03-150.pdf"},{"key":"5_CR180","unstructured":"US Government Publishing Office (2013) Code of Federal Regulations, Title 40: Protection of Environment, Chapter I: Environmental Protection Agency, Subchapter C: Air Programs, Part 50: National Primary and Secondary Ambient Air Quality Standards, \u00a7 50.18: National primary ambient air quality standards for PM2.5, 15 Jan 2013"},{"key":"5_CR181","unstructured":"Barclays Official California Code of Regulations (2006) Title 17: Public Health, Division 3: Air Resources, Chapter 1: Air Resources Board, Subchapter 1.5: Air Basins and Air Quality Standards, Article 2: Ambient Air Quality Standards, \u00a7 70200: Table of Standards, 17 May 2006"},{"key":"5_CR182","unstructured":"ESA\/VITO (2014) Space in images: Springtime in Europe, 4 June 2014. https:\/\/www.esa.int\/spaceinimages\/Images\/2014\/06\/Springtime_in_Europe"},{"key":"5_CR183","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1016\/j.envsoft.2015.02.022","volume":"74","author":"G Kiesewetter","year":"2015","unstructured":"Kiesewetter G, Schoepp W, Heyes C, Amann M (2015) Modelling PM2.5 impact indicators in Europe: health effects and legal compliance. Environ Model Softw 74:201\u2013211. ISSN 1364 8152, https:\/\/doi.org\/10.1016\/j.envsoft.2015.02.022","journal-title":"Environ Model Softw"},{"key":"5_CR184","doi-asserted-by":"publisher","unstructured":"Eeftens M, Tsai MY, Ampe C, Anwander B, Beelen R, Bellander T, Cesaroni G, Cirach M, Cyrys J, de Hoogh K, De Nazelle A, de Vocht F, Declercq C, D\u0117del\u0117 A, Eriksen K, Galassi C, Gra\u017eulevi\u010dien\u0117 R, Grivas G, Heinrich J, Hoffmann B, Iakovides M, Ineichen A, Katsouyanni K, Korek M, Kr\u00e4mer U, Kuhlbusch T, Lanki T, Madsen C, Meliefste K, M\u00f6lter A, Mosler G, Nieuwenhuijsen M, Oldenwening M, Pennanen A, Hensch NP, Quass U, Nielsen OR, Ranzi A, Stephanou E, Sugiri D, Udvardy O, Vask\u00f6vi \u00c9, Weinmayr G, Brunekreef B, Hoek G (2012) Spatial variation of PM2.5, PM10, PM2.5 absorbance and PMcoarse concentrations between and within 20 European study areas and the relationship with NO2\u2014Results of the ESCAPE project. Atmos Environ 62:303\u2013317. ISSN 1352 2310, https:\/\/doi.org\/10.1016\/j.atmosenv.2012.08.038","DOI":"10.1016\/j.atmosenv.2012.08.038"},{"key":"5_CR185","unstructured":"Boston University\/NASA GSFC (2002) New Land Cover Classification Maps\u2014Asia Print, Terra\u2014Modis, 14 Aug 2002. https:\/\/visibleearth.nasa.gov\/view.php?id=61004"},{"key":"5_CR186","doi-asserted-by":"crossref","unstructured":"Cheng Z, Luo L, Wang S, Wang Y, Sharma S, Shimadera H, Wang X, Bressi M, de Miranda RM, Jiang J, Zhou W, Fajardo O, Yan N, Hao J (2016) Status and characteristics of ambient PM2.5 pollution in global megacities. Environ Int 89\u201390:212\u2013221. 10.1016\/j.envint.2016.02.003, ISSN 0160 4120","DOI":"10.1016\/j.envint.2016.02.003"},{"key":"5_CR187","unstructured":"Aron P. Dobos, Standard Time Series Data File Format, National Renewable Energy Laboratory, August 2013, http:\/\/rredc.nrel.gov\/solar\/old_data\/nsrdb\/2005-2012\/wfcsv.pdf"},{"key":"5_CR188","unstructured":"Sengupta M, Habte A, Gotseff P, Weekley A, Lopez A, Molling C, Heidinger A (2014) A physics based GOES satellite product for use in NREL\u2019s national solar radiation database. National Renewable Energy Laboratory, July 2014, NREL\/CP 5D00 62237. https:\/\/www.nrel.gov\/docs\/fy14osti\/62237.pdf"},{"key":"5_CR189","unstructured":"Klick CH, Lef\u00e8vre M, Homscheidt MS, Wald L (2015) USER\u2019S GUIDE to the MACC RAD Services on solar energy radiation resources, Copernicus Atmospheric Monitoring Service, European Centre for Medium Range Weather Forecasts, Mar 2015. https:\/\/atmosphere.copernicus.eu\/sites\/default\/files\/repository\/MACCIII_RAD_DEL_D57.5_final_0.pdf"},{"key":"5_CR190","unstructured":"National Centers for Environmental Information, Integrated Surface Data, NCEI DSI 3505\u2014gov.noaa.ncdc:C00532, National Environmental Satellite, Data, and Information Service, National Oceanic and Atmospheric Administration, US Department of Commerce"},{"key":"5_CR191","unstructured":"White Box Technologies (2016) WBT. Used by permission. www.whiteboxtechnologies.com"},{"key":"5_CR192","unstructured":"California Air Resources Board, 2012 Air Quality Data DVD, August 2012, PTSD 2012 035 DVD"},{"key":"5_CR193","unstructured":"European Environment Agency (2014) AirBase\u2014The European air quality database, Version 7, Mar 2014"},{"key":"5_CR194","unstructured":"US Department of State, StateAir\u2014US Department of State Air Quality Monitoring Program\u2014Mission China"},{"key":"5_CR195","unstructured":"US Department of State, Mission India\u2014US Mission India NowCast Air Quality"},{"issue":"18","key":"5_CR196","doi-asserted-by":"publisher","first-page":"2895","DOI":"10.1016\/j.atmosenv.2004.02.026","volume":"38","author":"H Junninen","year":"2004","unstructured":"Junninen H, Niska H, Tuppurainen K, Ruuskanen J, Kolehmainen M (2004) Methods for imputation of missing values in air quality data sets. Atmos Environ 38(18):2895\u20132907. https:\/\/doi.org\/10.1016\/j.atmosenv.2004.02.026","journal-title":"Atmos Environ"},{"key":"5_CR197","doi-asserted-by":"publisher","unstructured":"Deru M, Field K, Studer D, Benne K, Griffith B, Torcellini P, Liu B, Halverson M, Winiarski D, Rosenberg M, Yazdanian M, Huang J, Crawley D (2011) US Department of Energy Commercial Reference Building Models of the National Building Stock, National Renewable Energy Laboratory, February, NREL\/TP 5500 46861. https:\/\/doi.org\/10.2172\/1009264","DOI":"10.2172\/1009264"},{"key":"5_CR198","unstructured":"Lerer MM, da Gra\u00e7a GC, Linden PF (2013) Building energy demand response simulation for an office tower in New York. In: Proceedings of BS2013: 13th conference of international building performance simulation association, Chamb\u00e9ry, France, 26\u201328 Aug 2013, pp 2511\u20132518. ISBN 9782746662940, http:\/\/www.ibpsa.org\/proceedings\/BS2013\/p_1350.pdf"},{"key":"5_CR199","unstructured":"Occupational Safety & Health Administration, Code of Federal Regulations, Title 29\u2014Labor, Part 1910\u2014Occupational Safety and Health Standards, Subpart J \u2013 General Environmental Controls, Standard Number 1910.141\u2014Sanitation"},{"key":"5_CR200","unstructured":"Department of Justice (2010) Americans with Disabilities Act of 1990, 2010 ADA Standards for Accessible Design, Sept 2010"},{"key":"5_CR201","unstructured":"California Building Standards Commission (2013) California Code of Regulations, Title 24\u2014Building Standards Code, Part 2\u2014California Building Code"},{"key":"5_CR202","unstructured":"Occupational Safety & Health Administration, Code of Federal Regulations, Title 29\u2014Labor, Part 1910\u2014Occupational Safety and Health Standards, Subpart D\u2014Walking Working Surfaces, Standard Number 1910.24\u2014Fixed industrial stairs"},{"issue":"4","key":"5_CR203","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1016\/S0378-7788(00)00114-6","volume":"33","author":"DB Crawley","year":"2001","unstructured":"Crawley DB, Lawrie LK, Winkelmann FC, Buhl WF, Joe Huang Y, Pedersen CO, Strand RK, Liesen RJ, Fisher DE, Witte MJ, Glazer J (2001) EnergyPlus: creating a new generation building energy simulation program. Energy Build 33(4):319\u2013331. ISSN 0378 7788, https:\/\/doi.org\/10.1016\/S0378-7788(00)00114-6","journal-title":"Energy Build"},{"key":"5_CR204","unstructured":"California Building Standards Commission (2013) California Code of Regulations, Title 24\u2014Building Standards Code, Part 6\u2014California Energy Code"},{"key":"5_CR205","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1016\/j.enbuild.2014.09.081","volume":"85","author":"P Raftery","year":"2014","unstructured":"Raftery P, Lee E, Webster T, Hoyt T, Bauman F (2014) Effects of furniture and contents on peak cooling load. Energy Build 85:445\u2013457. ISSN 0378 7788, https:\/\/doi.org\/10.1016\/j.enbuild.2014.09.081","journal-title":"Energy Build"},{"key":"5_CR206","doi-asserted-by":"publisher","unstructured":"Gowri K, Winiarski DW, Jarnagin RE (2009) Infiltration modeling guidelines for commercial building energy analysis. Office of Scientific and Technical Information, USA. https:\/\/doi.org\/10.2172\/968203","DOI":"10.2172\/968203"},{"key":"5_CR207","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1016\/j.enbuild.2014.07.033","volume":"82","author":"J Zhao","year":"2014","unstructured":"Zhao J, Lasternas B, Lam KP, Yun R, Loftness V (2014) Occupant behavior and schedule modeling for building energy simulation through office appliance power consumption data mining. Energy Build 82:341\u2013355. ISSN 0378 7788, https:\/\/doi.org\/10.1016\/j.enbuild.2014.07.033","journal-title":"Energy Build"},{"key":"5_CR208","unstructured":"ASHRAE (2013) ASHRAE handbook\u2014fundamentals. American Society of Heating, Refrigerating, and Air Conditioning Engineers Inc, Atlanta, GA, USA 2013, ISBN 978 1 93 650446, ISSN 1523 7230 6, ISSN 1523 7230"},{"key":"5_CR209","doi-asserted-by":"crossref","unstructured":"Leach M, Lobato C, Hirsch A, Pless S, Torcellini P (2010) Technical support document: strategies for 50% energy savings in large office buildings, national renewable energy laboratory, september. NREL\/CP 550 49213. https:\/\/www.nrel.gov\/docs\/fy10osti\/49213.pdf","DOI":"10.2172\/989024"},{"issue":"8","key":"5_CR210","doi-asserted-by":"publisher","first-page":"1937","DOI":"10.1016\/j.enbuild.2011.03.039","volume":"43","author":"IS Ertesv\u00e5g","year":"2011","unstructured":"Ertesv\u00e5g IS (2011) Uncertainties in heat pump coefficient of performance (COP) and exergy efficiency based on standardized testing. Energy Build 43(8):1937\u20131946. ISSN 0378 7788, https:\/\/doi.org\/10.1016\/j.enbuild.2011.03.039","journal-title":"Energy Build"},{"key":"5_CR211","doi-asserted-by":"publisher","first-page":"665","DOI":"10.1016\/j.rser.2015.03.087","volume":"47","author":"PM Cuce","year":"2015","unstructured":"Cuce PM, Riffat S (2015) A comprehensive review of heat recovery systems for building applications. Renew Sustain Energy Rev 47:665\u2013682. ISSN 1364 0321, https:\/\/doi.org\/10.1016\/j.rser.2015.03.087","journal-title":"Renew Sustain Energy Rev"},{"key":"5_CR212","doi-asserted-by":"crossref","unstructured":"Pigeon Bergmann PA, Abrishami M, Ciminelli M, Bender S, Hall V, Blevins BB (2006) California commercial end use survey\u2014report. California Energy Commission & Itron, Inc, Mar 2006, CEC 400 2006 005. http:\/\/www.energy.ca.gov\/2006publications\/CEC-400-2006-005\/CEC-400-2006-005.PDF","DOI":"10.1088\/1126-6708\/2006\/02\/005"},{"key":"5_CR213","unstructured":"Warren PR (1986) The analysis of single sided ventilation measurements. Air Infiltration Rev 7(2):3\u20135"},{"key":"5_CR214","unstructured":"Fergus Nicol J (2001) Characterising occupant behaviour in buildings: towards a stochastic model of occupant use of windows, lights, blinds, heaters and fans. In: Proceedings of seventh international IBPSA conference: building simulation, 13\u201315 Aug 2001, Rio de Janeiro, Brazil, pp 1073\u20131078. ISBN 9788590193944, http:\/\/www.ibpsa.org\/proceedings\/BS2001\/BS01_1073_1078.pdf"},{"key":"5_CR215","unstructured":"European Committee for Standardization (2012) Particulate air filters for general ventilation. Determination of the filtration performance. EN 779:2012"},{"issue":"4","key":"5_CR216","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1034\/j.1600-0668.2002.01136.x","volume":"12","author":"WJ Fisk","year":"2002","unstructured":"Fisk WJ, Faulkner D, Palonen J, Seppanen O (2002) Performance and costs of particle air filtration technologies. Indoor Air 12(4):223\u2013234. ISSN 1600 0668, https:\/\/doi.org\/10.1034\/j.1600-0668.2002.01136.x","journal-title":"Indoor Air"},{"issue":"3","key":"5_CR217","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1111\/j.1600-0668.2008.00518.x","volume":"18","author":"MS Waring","year":"2008","unstructured":"Waring MS, Siegel JA (2008) Particle loading rates for HVAC filters, heat exchangers, and ducts. Indoor Air 18(3):209\u2013224. ISSN 1600 0668, https:\/\/doi.org\/10.1111\/j.1600-0668.2008.00518.x","journal-title":"Indoor Air"}],"container-title":["PoliTO Springer Series","Innovations in Ventilative Cooling"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-030-72385-9_5","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,6,8]],"date-time":"2021-06-08T14:37:11Z","timestamp":1623163031000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-030-72385-9_5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021]]},"ISBN":["9783030723842","9783030723859"],"references-count":217,"URL":"https:\/\/doi.org\/10.1007\/978-3-030-72385-9_5","relation":{},"ISSN":["2509-6796","2509-7024"],"issn-type":[{"value":"2509-6796","type":"print"},{"value":"2509-7024","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021]]},"assertion":[{"value":"9 June 2021","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}}]}}