{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,13]],"date-time":"2026-04-13T10:45:20Z","timestamp":1776077120965,"version":"3.50.1"},"publisher-location":"Cham","reference-count":115,"publisher":"Springer International Publishing","isbn-type":[{"value":"9783030832964","type":"print"},{"value":"9783030832971","type":"electronic"}],"license":[{"start":{"date-parts":[[2021,11,27]],"date-time":"2021-11-27T00:00:00Z","timestamp":1637971200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,11,27]],"date-time":"2021-11-27T00:00:00Z","timestamp":1637971200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022]]},"DOI":"10.1007\/978-3-030-83297-1_3","type":"book-chapter","created":{"date-parts":[[2021,11,26]],"date-time":"2021-11-26T13:02:37Z","timestamp":1637931757000},"page":"83-126","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Hygrothermal and Acoustic Assessment of Earthen Materials"],"prefix":"10.1007","author":[{"given":"Antonin","family":"Fabbri","sequence":"first","affiliation":[]},{"given":"Jean-Emmanuel","family":"Aubert","sequence":"additional","affiliation":[]},{"given":"Ana Armanda","family":"Bras","sequence":"additional","affiliation":[]},{"given":"Paulina","family":"Faria","sequence":"additional","affiliation":[]},{"given":"Domenico","family":"Gallipoli","sequence":"additional","affiliation":[]},{"given":"Jeanne","family":"Goffart","sequence":"additional","affiliation":[]},{"given":"Fionn","family":"McGregor","sequence":"additional","affiliation":[]},{"given":"C\u00e9line","family":"Perlot-Bascoules","sequence":"additional","affiliation":[]},{"given":"Lucile","family":"Soudani","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2021,11,27]]},"reference":[{"key":"3_CR1","doi-asserted-by":"crossref","unstructured":"Farouki OT (1981) Thermal properties of soils","DOI":"10.21236\/ADA111734"},{"key":"3_CR2","unstructured":"ASTM-C177 (2013) Standard test method for steady-state heat flux measurements and thermal transmission properties by means of the guarded-hot-plate apparatus. ASTM International"},{"key":"3_CR3","unstructured":"ASTM-D5334 (2014) Standard test method for determination of thermal conductivity of soil and soft rock by thermal needle probe procedure. ASTM International"},{"key":"3_CR4","unstructured":"ASTM-E793-06 (2012) Standard test method for enthalpies of fusion and crystallization by differential scanning calorimetry. ASTM International"},{"issue":"2","key":"3_CR5","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1016\/0360-1323(94)00041-P","volume":"30","author":"EA Adam","year":"1995","unstructured":"Adam EA, Jones PJ (1995) Thermophysical properties of stabilised soil building blocks. Build Environ 30(2):245\u2013253. https:\/\/doi.org\/10.1016\/0360-1323(94)00041-P","journal-title":"Build Environ"},{"key":"3_CR6","unstructured":"Adam EA (2001) Compressed stabilized earth block manufacturing in Sudan\u2014UNESCO\u2014Technical Note No. 12. Organization, p 101"},{"key":"3_CR7","first-page":"55","volume":"2014","author":"U Alev","year":"2014","unstructured":"Alev U et al (2014) Air leakage and hygrothermal performance of an internally insulated log house. NSB 2014:55\u201361","journal-title":"NSB"},{"key":"3_CR8","doi-asserted-by":"publisher","DOI":"10.1016\/j.enbuild.2009.12.005","author":"D Allinson","year":"2010","unstructured":"Allinson D, Hall M (2010) Hygrothermal analysis of a stabilised rammed earth test building in the UK. Energy and Buildings. https:\/\/doi.org\/10.1016\/j.enbuild.2009.12.005","journal-title":"Energy and Buildings"},{"key":"3_CR9","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1016\/j.enbuild.2009.12.005","volume":"42","author":"D Allinson","year":"2010","unstructured":"Allinson D, Hall MR (2010) Hygrothermal analysis of a stabilised rammed earth test building in the UK. Energy and Buildings 42:845\u2013852","journal-title":"Energy and Buildings"},{"key":"3_CR10","doi-asserted-by":"crossref","unstructured":"Aplin AC, Fleet AJ, Macquaker JHS (1999) Muds and mudstones: physical and fluid-flow properties. Geological Society of London","DOI":"10.1144\/GSL.SP.1999.158.01.01"},{"key":"3_CR11","first-page":"101","volume":"37","author":"P Arnold","year":"1969","unstructured":"Arnold P (1969) Thermal conductivity of masonry materials. J Inst Heat Ventilating Eng 37:101\u2013108","journal-title":"J Inst Heat Ventilating Eng"},{"key":"3_CR12","first-page":"351","volume":"65","author":"A Arundel","year":"1986","unstructured":"Arundel A, Sterling E, Biggin J (1986) Indirect health effect of relative humidity in indoor environments. Environ Health Perspect 65:351","journal-title":"Environ Health Perspect"},{"key":"3_CR13","doi-asserted-by":"publisher","unstructured":"Badea A et al (1994) A life-cycle cost analysis of the passive house \u201cPolitenica\u201d from Bucharest. Energy Build 80(2014):542\u2013555. https:\/\/doi.org\/10.1016\/j.enbuild.2014.04.044","DOI":"10.1016\/j.enbuild.2014.04.044"},{"issue":"6","key":"3_CR14","first-page":"671","volume":"11","author":"V Baroghel-Bouny","year":"2007","unstructured":"Baroghel-Bouny V et al (2007) Assessment of transport properties of cementitious materials: a major challenge as regards durability? Eur J Environ Civ Eng 11(6):671\u2013696","journal-title":"Eur J Environ Civ Eng"},{"key":"3_CR15","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1016\/j.jobe.2017.11.013","volume":"15","author":"CTS Beckett","year":"2018","unstructured":"Beckett CTS, Cardell-Oliver R, Ciancio D, Huebner C (2018) Measured and simulated thermal behaviour in rammed earth houses in a hot-arid climate. Part A: Structural behaviour. J Build Eng 15:243\u2013251","journal-title":"J Build Eng"},{"key":"3_CR16","unstructured":"Beckett C et al (2014) Sustainable and affordable rammed earth houses in Kalgoorlie, western Autralia\u202f: development of thermal monitoring techniques. In: ASEC 2014"},{"issue":"6","key":"3_CR17","doi-asserted-by":"crossref","first-page":"2225","DOI":"10.1029\/JB073i006p02225","volume":"73","author":"WF Brace","year":"1968","unstructured":"Brace WF, Walsh JB, Frangos WT (1968) Permeability of granite under high pressure. J Geophys Res 73(6):2225\u20132236","journal-title":"J Geophys Res"},{"key":"3_CR18","unstructured":"Bras A (2015) Repair of Quinta da Mina buildings belonging to a social neighbourhood (Barreiro, Portugal)\u2014selection of retrofit solutions to improve the energy efficiency of a group of buildings. Technical report for the city council"},{"key":"3_CR19","doi-asserted-by":"publisher","unstructured":"Butko D et al (2014) Comparing the acoustical nature of a Compressed Earth Block (CEB) residence to a traditional wood\u00ad\u2010framed residence. In: Proceedings of meetings on acoustics. Acoustical Society of America, p 015002. https:\/\/doi.org\/10.1121\/2.0000083","DOI":"10.1121\/2.0000083"},{"key":"3_CR20","unstructured":"CSTB (2011) Analyse des caract\u00e9ristiques des syst\u00e8mes constructifs non industrialis\u00e9s"},{"key":"3_CR21","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1016\/j.enbuild.2014.05.024","volume":"80","author":"H Cagnon","year":"2014","unstructured":"Cagnon H et al (2014) Hygrothermal properties of earth bricks. Energy Build 80:208\u2013217","journal-title":"Energy Build"},{"key":"3_CR22","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1023\/A:1006500716417","volume":"35","author":"J Carmeliet","year":"1999","unstructured":"Carmeliet J, Descamps F, Houvenaghel G (1999) A mutliscale network model for simulating moisture transfer properties of porous media. Transp Porous Media 35:67\u201388","journal-title":"Transp Porous Media"},{"key":"3_CR23","doi-asserted-by":"crossref","first-page":"829","DOI":"10.1016\/j.sbspro.2015.12.080","volume":"216","author":"P Carneiro","year":"2016","unstructured":"Carneiro P et al (2016) Improving building technologies with a sustainable strategy. Procedia Soc Behav Sci 216:829\u2013840","journal-title":"Procedia Soc Behav Sci"},{"key":"3_CR24","unstructured":"Cassan M (2005) Les essais de perm\u00e9abilit\u00e9 sur site dans la reconnaissance des sols. Presses de l\u2019Ecole Nationale des Ponts et Chaus\u00e9es"},{"key":"3_CR25","unstructured":"Chabriac PA (2014) Mesure du comportement hygrothermique du pis\u00e9. ENTPE. Available at: https:\/\/tel.archives-ouvertes.fr\/tel-01413611"},{"key":"3_CR26","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1016\/j.conbuildmat.2016.01.027","volume":"110","author":"F Champir\u00e9","year":"2016","unstructured":"Champir\u00e9 F et al (2016) Impact of relative humidity on the mechanical behavior of compacted earth as a building material. Constr Build Mater 110:70\u201378. https:\/\/doi.org\/10.1016\/j.conbuildmat.2016.01.027","journal-title":"Constr Build Mater"},{"key":"3_CR27","doi-asserted-by":"crossref","DOI":"10.1007\/978-1-4020-3995-9","volume-title":"Encyclopedia of soil science","author":"W Chesworth","year":"2008","unstructured":"Chesworth W (2008) Encyclopedia of soil science. Springer"},{"key":"3_CR28","unstructured":"Cliffton AW, Wilson GW, Barbour SL (1999) Emergence of unsaturated soil mechanics. NRC Research Press"},{"issue":"19","key":"3_CR29","first-page":"38","volume":"19","author":"A Corey","year":"1954","unstructured":"Corey A (1954) The interrelation between gas and oil relative permeabilities. Producers Monthly 19(19):38\u201341","journal-title":"Producers Monthly"},{"key":"3_CR30","unstructured":"DIN-51007 (1994) Thermal analysis; differential thermal analysis; principles. Deutsches Institut f\u00fcr Normung"},{"key":"3_CR31","unstructured":"DIN-52612-2 (1984) Tesing of thermal insulating materials; determination of thermal conductivity by means of the guarded hot plate apparatus; conversion of the measured values for building applications. Deutsches Institut f\u00fcr Normung"},{"key":"3_CR32","unstructured":"Daza AN, Zambrano E, Ruiz JA (2016) Acoustic performance in raw earth construction techniques used in Colombia. In: EuroRegio2016, European Association of Acoustics. Porto, pp 1\u201310"},{"key":"3_CR33","unstructured":"Delage P, Cui YJ (2000) L\u2019eau dans les sols non satur\u00e9s. Techniques de l\u2019ing\u00e9nieur, C301"},{"key":"3_CR34","doi-asserted-by":"crossref","first-page":"1379","DOI":"10.1016\/j.cemconres.2012.06.010","volume":"42","author":"H Derluyn","year":"2012","unstructured":"Derluyn H et al (2012) Hysteretic behavior of concrete: Modeling and analysis. Cem Concr Res 42:1379\u20131388","journal-title":"Cem Concr Res"},{"key":"3_CR35","doi-asserted-by":"crossref","first-page":"1038","DOI":"10.1016\/j.buildenv.2010.11.002","volume":"46","author":"T Desta","year":"2011","unstructured":"Desta T, Langmans J, Roels S (2011) Experimental data set for validation of heat, air and moisture transport models of building envelopes. Build Environ 46:1038\u20131046","journal-title":"Build Environ"},{"key":"3_CR36","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1016\/j.buildenv.2014.06.018","volume":"81","author":"S Dubois","year":"2014","unstructured":"Dubois S et al (2014) An inverse modelling approach to estimate the hygric parameters of clay-based masonry during a Moisture Buffer Value test. Build Environ 81:192\u2013203. https:\/\/doi.org\/10.1016\/j.buildenv.2014.06.018","journal-title":"Build Environ"},{"issue":"2006","key":"3_CR37","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1016\/j.energy.2005.04.006","volume":"31","author":"AF Emery","year":"2005","unstructured":"Emery AF, Kippenhan CJ (2005) A long term study of residential home heating consumption and the effect of occupant behavior on homes in the Pacific Northwest constructed according to improved thermal standards. Energy 31(2006):677\u2013693. https:\/\/doi.org\/10.1016\/j.energy.2005.04.006","journal-title":"Energy"},{"key":"3_CR38","doi-asserted-by":"crossref","first-page":"912","DOI":"10.1016\/j.crme.2019.11.017","volume":"347","author":"A Fabbri","year":"2019","unstructured":"Fabbri A, Al Haffar N, McGregor F (2019) Measurement of the relative air permeability of compacted earth in the hygroscopic regime of saturation. CR Mec 347:912\u2013919","journal-title":"CR Mec"},{"key":"3_CR39","doi-asserted-by":"publisher","DOI":"10.1016\/j.conbuildmat.2017.09.077","author":"A Fabbri","year":"2017","unstructured":"Fabbri A, McGregor F (2017) Impact of the determination of the sorption-desorption curves on the prediction of the hemp concrete hygrothermal behaviour. Constr Build Mater. https:\/\/doi.org\/10.1016\/j.conbuildmat.2017.09.077","journal-title":"Constr Build Mater"},{"key":"3_CR40","doi-asserted-by":"publisher","unstructured":"Fabbri A et al (2017) Effect of temperature on the sorption curves of earthen materials. Materials and Structures\/Materiaux et Constructions 50(6). https:\/\/doi.org\/10.1617\/s11527-017-1122-7","DOI":"10.1617\/s11527-017-1122-7"},{"key":"3_CR41","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1111\/j.1600-0668.1999.t01-1-00006.x","volume":"9","author":"L Fang","year":"1999","unstructured":"Fang L, Clausen G, Fanger PO (1999) Impact of temperatre and humidity on chemical and sensory emissions from building materials. Indoor Air 9:193\u2013201","journal-title":"Indoor Air"},{"key":"3_CR42","unstructured":"Faria P, Bras A (2017) Building physics. In: Jones D, Brischke C (eds) Performance of bio-based building materials. Woodhead Publishing Series in Civil and Structural Engineering, pp 335\u2013344"},{"key":"3_CR43","volume-title":"Enveloppe hybride pour b\u00e2timent \u00e0 haute performance \u00e9nerg\u00e9tique","author":"X Faure","year":"2008","unstructured":"Faure X (2008) Enveloppe hybride pour b\u00e2timent \u00e0 haute performance \u00e9nerg\u00e9tique. Universit\u00e9 Joseph Fourier, Grenoble I"},{"key":"3_CR44","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1016\/j.buildenv.2014.11.036","volume":"85","author":"C Feng","year":"2015","unstructured":"Feng C et al (2015) Hygric properties of porous building materials\u202f: Analysis of measurement repeatability and reproducibility. Build Environ 85:160\u2013172","journal-title":"Build Environ"},{"key":"3_CR45","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/0360-1323(95)00027-5","volume":"31","author":"VP De Freitas","year":"1996","unstructured":"De Freitas VP, Abrantes V, Crausse P (1996) Moisture migration in building walls\u2014analysis of the interface phenomena. Build Environ 31:99\u2013108","journal-title":"Build Environ"},{"key":"3_CR46","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1097\/00010694-195804000-00006","volume":"85","author":"W Gardner","year":"1958","unstructured":"Gardner W (1958) Some steady state solutions of the unsaturated moisture flow equation with application to evaporation from a water table. Soil Sci 85:228\u2013232","journal-title":"Soil Sci"},{"issue":"1","key":"3_CR47","first-page":"122","volume":"24","author":"A Gemant","year":"1952","unstructured":"Gemant A (1952) How to compute thermal soil conductivities. Heat Piping Air Cond 24(1):122\u2013123","journal-title":"Heat Piping Air Cond"},{"key":"3_CR48","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.enbuild.2014.01.016","volume":"74","author":"H Goncalves","year":"2014","unstructured":"Goncalves H et al (2014) The influence of porogene additives on the properties of mortars used to control the ambient moisture. Energy Build 74:61\u201368","journal-title":"Energy Build"},{"key":"3_CR49","doi-asserted-by":"publisher","unstructured":"Guerra-santin O et al (2013) Monitoring the performance of low energy dwellings\u202f: two UK case studies. Energy Build 64:32\u201340. https:\/\/doi.org\/10.1016\/j.enbuild.2013.04.002","DOI":"10.1016\/j.enbuild.2013.04.002"},{"issue":"4","key":"3_CR50","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1177\/1097196304042436","volume":"27","author":"C-EE Hagentoft","year":"2004","unstructured":"Hagentoft C-EE et al (2004) Assessment method for numerical prediction models for combined heat, air and moisture transfer in building components: benchmarcks for one-dimensional cases. J Therm Envelope Build Sci 27(4):327\u2013351. https:\/\/doi.org\/10.1177\/1097196304042436","journal-title":"J Therm Envelope Build Sci"},{"key":"3_CR51","doi-asserted-by":"crossref","first-page":"740","DOI":"10.1016\/j.applthermaleng.2008.03.051","volume":"29","author":"MR Hall","year":"2009","unstructured":"Hall MR, Allinson D (2009) Assessing the effects of soil grading on the moisture contentdependent thermal conductivity of stabilised rammed earth materials. Appl Therm Eng 29:740\u2013747","journal-title":"Appl Therm Eng"},{"key":"3_CR52","doi-asserted-by":"crossref","unstructured":"Hall M, Lindsay R, Krayenhoff M (2012) Modern earth buildings 1st Edition Materials, Engineering, Constructions and Applications","DOI":"10.1533\/9780857096166"},{"key":"3_CR53","volume-title":"Handbook of chemistry and physics","author":"WM Haynes","year":"2015","unstructured":"Haynes WM, Lide DR, Bruno TJ (2015) Handbook of chemistry and physics. CRC Press"},{"key":"3_CR54","unstructured":"Horoshenkov KV et al (2011) The effect of moisture and soil type on the acoustical properties of green noise control elements. In: Proceedings of forum acusticum 2011, (ii), pp 845\u2013849"},{"key":"3_CR55","unstructured":"IEEE-442 (1981) IEEE Guide for soil thermal resistivity measurements. Institute of Electrical and Electronics Engineers"},{"key":"3_CR56","unstructured":"ISO 11357-1 (2016) Plastics\u2014differential scanning calorimetry (DSC)\u2014Part 1: General principles. International Organization for Standardization"},{"key":"3_CR57","unstructured":"ISO 12571 (2013) Hygrothermal performance of building materials and products\u2014determination of hygroscopic sorption properties. International Organization for Standardization, Geneva, Switzerland, pp 1\u201322"},{"key":"3_CR58","unstructured":"ISO 12572 (2001) Determination of water vapour transmission properties. International Organization for Standardization, Geneva, Switzerland"},{"key":"3_CR59","unstructured":"ISO 22007-2 (2015) Determination of thermal conductivity and thermal diffusivity\u2014Part 2: Transient plane heat source (hot disc) method. International Organization for Standardization"},{"key":"3_CR60","unstructured":"ISO 8302 (1991) Thermal insulation\u2014determination of steady-state thermal resistance and related properties\u2014Guarded hot plate apparatus. International Organization for Standardization"},{"key":"3_CR61","doi-asserted-by":"publisher","unstructured":"Irulegi O et al (2014) The Ekihouse\u202f: an energy self-sufficient house based on passive design strategies. Energy Build 83:57\u201369. https:\/\/doi.org\/10.1016\/j.enbuild.2014.03.077","DOI":"10.1016\/j.enbuild.2014.03.077"},{"key":"3_CR62","volume-title":"Fundamentals of atmospheric modeling","author":"MZ Jacobson","year":"1999","unstructured":"Jacobson MZ (1999) Fundamentals of atmospheric modeling. Cambridge University Press"},{"key":"3_CR63","unstructured":"Kedowide Y (2015) Analyses exp\u00e9rimentales et num\u00e9riques du comportement hygrothermique d\u2019une paroi compos\u00e9e de mat\u00e9riaux fortement hygroscopiques. Universit\u00e9 Savoie Mont-Blanc"},{"key":"3_CR64","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1016\/j.buildenv.2008.05.006","volume":"44","author":"J Kwiatkowski","year":"2009","unstructured":"Kwiatkowski J, Woloszyn M, Roux J-J (2009) Modelling of hysteresis influence on mass transfer in building materials. Build Environ 44:633\u2013642","journal-title":"Build Environ"},{"key":"3_CR65","unstructured":"K\u00fcnzel HM (1995) Simultaneous heat and moisture transport in building components. Fraunhofer IRB Verlag Suttgart"},{"key":"3_CR66","unstructured":"K\u00fcnzel HM, Gertis EHMK (1995) Simultaneous heat and moisture transport in building components One-and two-dimensional calculation using simple parameters. Fraunhofer IRB Verlag Suttgart"},{"key":"3_CR67","unstructured":"Labarta G (2015) Rammed earth as a construction buiding material. Warsaw University of Technology"},{"key":"3_CR68","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.buildenv.2015.12.004","volume":"97","author":"M Labat","year":"2016","unstructured":"Labat M et al (2016) From the experimental characterisation of the hygrothermal properties of straw-cvlay mixtures to the numerical assessment of their bu ering potential. Build Environ 97:69\u201381","journal-title":"Build Environ"},{"key":"3_CR69","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1080\/19401493.2015.1107136","volume":"9","author":"M Labat","year":"2016","unstructured":"Labat M, Woloszyn M (2016) Moisture balance assessment at room scale for four cases based on numerical simulations of heat\u2013air\u2013moisture transfers for a realistic occupancy scenario. J Build Performance Simulation 9:487\u2013509","journal-title":"J Build Performance Simulation"},{"key":"3_CR70","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1016\/j.buildenv.2016.09.017","volume":"109","author":"E Latif","year":"2016","unstructured":"Latif E et al (2016) In situ assessment of the fabric and energy performance of five conventional and non-conventional wall systems using comparative coheating tests. Build Environ 109:68\u201381. https:\/\/doi.org\/10.1016\/j.buildenv.2016.09.017","journal-title":"Build Environ"},{"key":"3_CR71","unstructured":"Laurent J (1986) Contribution \u00e0 la caract\u00e9risation thermique des milieux poreux granulaires. Institut National Polytechnique, Grenoble"},{"key":"3_CR72","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1016\/j.enbuild.2014.09.013","volume":"84","author":"D Lelievre","year":"2014","unstructured":"Lelievre D, Colinart T, Glouannec P (2014) Hygrothermal behavior of bio-based building materials including hysteresis effects: experimental and numerical analyses. Energy Build 84:617\u2013627","journal-title":"Energy Build"},{"key":"3_CR73","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1016\/j.buildenv.2012.12.006","volume":"61","author":"S Liuzzi","year":"2013","unstructured":"Liuzzi S et al (2013) Hygrothermal behaviour and relative humidity buffering of unfired and hydrated lime-stabilised clay composites in a Mediterranean climate. Build Environ 61:82\u201392","journal-title":"Build Environ"},{"key":"3_CR74","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1617\/s11527-017-1061-3","volume":"50","author":"F McGregor","year":"2017","unstructured":"McGregor F et al (2017) Impact of the surface film resistance on the hygric properties of clay plasters. Mater Struct 50:193","journal-title":"Mater Struct"},{"key":"3_CR75","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/j.buildenv.2014.09.027","volume":"82","author":"F McGregor","year":"2014","unstructured":"McGregor F, Heath A, Shea A (2014) The moisture buffering capacity of unfiered clay masonry. Build Environ 82:207\u2013599","journal-title":"Build Environ"},{"key":"3_CR76","doi-asserted-by":"publisher","unstructured":"McGregor F et al (2014) The moisture buffering capacity of unfired clay masonry. Build Environ 82. https:\/\/doi.org\/10.1016\/j.buildenv.2014.09.027","DOI":"10.1016\/j.buildenv.2014.09.027"},{"key":"3_CR77","doi-asserted-by":"publisher","unstructured":"McGregor F et al (2016) A review on the buffering capacity of earth building materials 169(5). https:\/\/doi.org\/10.1680\/jcoma.15.00035","DOI":"10.1680\/jcoma.15.00035"},{"key":"3_CR78","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1111\/j.1551-2916.1954.tb20106.x","volume":"37","author":"M McQuarrie","year":"1954","unstructured":"McQuarrie M (1954) Thermal conductivity: VII, Analysis of variation of conductivity with temperature for Al2O3, BeO, and MgO. J Am Ceramic Soc 37:91\u201395","journal-title":"J Am Ceramic Soc"},{"key":"3_CR79","first-page":"1","volume":"2014","author":"D Medjelekh","year":"2014","unstructured":"Medjelekh D et al (2014) Mesure et mod\u00e9lisation des transferts hygrothermiques d\u2019une enveloppe en b\u00e9ton de bois. IBPSA 2014:1\u20138","journal-title":"IBPSA"},{"key":"3_CR80","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1180\/000985598545327","volume":"33","author":"K Midttomme","year":"1998","unstructured":"Midttomme K, Roaldset E, Aagaard P (1998) Thermal conductivity of selected claystones and mudstones from England. Clay Miner 33:131\u2013145","journal-title":"Clay Miner"},{"key":"3_CR81","doi-asserted-by":"crossref","unstructured":"Minke G (2012) Building with earth: design and technology of a sustainable architecture. Birkh\u00e4user\u2014Publishers for Architecture","DOI":"10.1515\/9783034608725"},{"issue":"3","key":"3_CR82","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1080\/01457630500458187","volume":"27","author":"MG Mwaba","year":"2006","unstructured":"Mwaba MG et al (2006) Experimental investigation of CaSO4 crystallization on a flat plate. Heat Transfer Eng 27(3):42\u201354","journal-title":"Heat Transfer Eng"},{"key":"3_CR83","volume-title":"Handbook of energy data and calculations","author":"P Osborn","year":"2013","unstructured":"Osborn P (2013) Handbook of energy data and calculations. Butterworth"},{"issue":"9","key":"3_CR84","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1016\/j.crme.2015.06.009","volume":"343","author":"F Osselin","year":"2015","unstructured":"Osselin F et al (2015) \u2018Experimental investigation of the influence of supercritical state on the relative permeability of Vosges sandstone\u2019, Comptes Rendus - Mecanique. Elsevier Masson SAS 343(9):495\u2013502. https:\/\/doi.org\/10.1016\/j.crme.2015.06.009","journal-title":"Elsevier Masson SAS"},{"key":"3_CR85","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1016\/j.matdes.2009.07.011","volume":"31","author":"JE Oti","year":"2010","unstructured":"Oti JE, Kinuthia JM, Bai J (2010) Design thermal values for unfired clay bricks. Mater Des 31:104\u2013112","journal-title":"Mater Des"},{"key":"3_CR86","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1016\/j.conbuildmat.2015.12.117","volume":"106","author":"YA Oumeziane","year":"2016","unstructured":"Oumeziane YA et al (2016) Influence of temperature on sorption process in hemp concrete. Constr Build Mater 106:600\u2013607","journal-title":"Constr Build Mater"},{"key":"3_CR87","doi-asserted-by":"crossref","first-page":"1393","DOI":"10.1021\/la8020244","volume":"25","author":"RJM Pellenq","year":"2009","unstructured":"Pellenq RJM et al (2009) Simple model for phase transition in confined geometry. 2: Capillary condensation\/evaporation in cylindrical pores. Langmuir 25:1393\u20131402","journal-title":"Langmuir"},{"key":"3_CR88","doi-asserted-by":"publisher","first-page":"2076","DOI":"10.1016\/j.enbuild.2008.05.012","volume":"40","author":"C Peng","year":"2008","unstructured":"Peng C, Wu Z (2008) In situ measuring and evaluating the thermal resistance of building construction. Energy Build 40:2076\u20132082. https:\/\/doi.org\/10.1016\/j.enbuild.2008.05.012","journal-title":"Energy Build"},{"issue":"6","key":"3_CR89","doi-asserted-by":"crossref","first-page":"1322","DOI":"10.1016\/j.enbuild.2011.01.008","volume":"43","author":"A Piot","year":"2011","unstructured":"Piot A et al (2011) Experimental wooden frame house for the validation of whole building heat and moisture transfer numerical models. Energy Build 43(6):1322\u20131328","journal-title":"Energy Build"},{"key":"3_CR90","doi-asserted-by":"crossref","DOI":"10.1201\/9781482265675","volume-title":"Microstructure of Smectite and engineering performance","author":"R Pusch","year":"2006","unstructured":"Pusch R, Young R (2006) Microstructure of Smectite and engineering performance. Taylor & Francis Group, London"},{"key":"3_CR91","doi-asserted-by":"publisher","unstructured":"Ridley I et al (2013) The monitored performance of the first new London dwelling certified to the Passive House standard. Energy Build 63:67\u201378. https:\/\/doi.org\/10.1016\/j.enbuild.2013.03.052","DOI":"10.1016\/j.enbuild.2013.03.052"},{"key":"3_CR92","doi-asserted-by":"publisher","unstructured":"Ridley I et al (no date) The side by side in use monitored performance of two passive and low carbon Welsh houses. Energy Build 82(2014):13\u201326. https:\/\/doi.org\/10.1016\/j.enbuild.2014.06.038","DOI":"10.1016\/j.enbuild.2014.06.038"},{"key":"3_CR93","unstructured":"Rinc\u00f3n L et al (2015) Experimental rammed earth prototypes in Mediterranean climate. In: Mileto V, Soriano G (eds) Earthen architecture: past, present and future. Taylor & Francis, London, pp 311\u2013316"},{"key":"3_CR94","unstructured":"Rode C et al (2005) Nordic Innovation Centre: moisture buffer value of building materials. Technical Report of the Technical University of Denmark"},{"key":"3_CR95","doi-asserted-by":"publisher","unstructured":"Roels S et al (2004) Interlaboratory comparison of hygric properties of porous building materials. J Thermal Envelope Build Sci 27(4):307\u2013325. https:\/\/doi.org\/10.1177\/1097196304042119","DOI":"10.1177\/1097196304042119"},{"key":"3_CR96","unstructured":"Scheffler G, Grunewald J (2003) Material development and optimisation supported by numerical simulation for a capillary-active inside insulation material. In: Vermeir GLG, Hens H, Carmeliet J (eds) Research in building physics\u2014proceedings of the 2nd CIB co-sponsored international conference on building physics. In-house Publishing"},{"key":"3_CR97","doi-asserted-by":"crossref","DOI":"10.1007\/978-3-8348-9366-6","volume-title":"Lehmbau","author":"H Schroeder","year":"2010","unstructured":"Schroeder H (2010) Lehmbau. Vieweg+Teubner, Wiesbaden"},{"key":"3_CR98","first-page":"101","volume":"2010","author":"A Shea","year":"2010","unstructured":"Shea A, Beadle K, Walker P (2010) Dynamic simulation and full-scale testing of a pre-fabricated straw-bale house. ICSBE 2010:101\u2013107","journal-title":"ICSBE"},{"key":"3_CR99","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1016\/j.conbuildmat.2012.04.123","volume":"36","author":"A Shea","year":"2012","unstructured":"Shea A, Lawrence M, Walker P (2012) Hygrothermal performance of an experimental hemp\u2014lime building Construction and Building Materials. Constr Build Mater 36:270\u2013275. https:\/\/doi.org\/10.1016\/j.conbuildmat.2012.04.123","journal-title":"Constr Build Mater"},{"key":"3_CR100","unstructured":"Soebarto V (2009) Analysis of indoor performance of houses using rammed earth walls. In: Eleventh international IBPSA conference. Glasgow"},{"key":"3_CR101","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1016\/j.enbuild.2016.01.025","volume":"116","author":"L Soudani","year":"2016","unstructured":"Soudani L, Fabbri A et al (2016) Assessment of the validity of some common assumptions in hygrothermal modeling of earth based materials. Energy Build 116:498\u2013511","journal-title":"Energy Build"},{"key":"3_CR102","doi-asserted-by":"publisher","unstructured":"Soudani L, Woloszyn M, Fabbri A, Morel JC, Grillet AC (2017) Energy evaluation of rammed earth walls using long term in-situ measurements. Sol Energy 141:70\u201380. https:\/\/doi.org\/10.1016\/j.solener.2016.11.002","DOI":"10.1016\/j.solener.2016.11.002"},{"key":"3_CR103","unstructured":"Stefanoiu AM et al (2016) Comparison between the design phase and the real behavioral measurements of an Energy Efficient Building. In: IBPSA France, pp 1\u20138"},{"key":"3_CR104","volume-title":"Moisture buffering in the indoor environment","author":"K Svennberg","year":"2006","unstructured":"Svennberg K (2006) Moisture buffering in the indoor environment. Lund University, LTH"},{"key":"3_CR105","doi-asserted-by":"crossref","first-page":"793","DOI":"10.1016\/j.enbuild.2007.05.013","volume":"40","author":"P Taylor","year":"2008","unstructured":"Taylor P, Fuller RJ, Luther MB (2008) Energy use and thermal comfort in a rammed earth office building. Energy Build 40:793\u2013800","journal-title":"Energy Build"},{"issue":"1\u20133","key":"3_CR106","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1016\/j.solener.2003.08.026","volume":"76","author":"P Taylor","year":"2004","unstructured":"Taylor P, Luther MB (2004) Evaluating rammed earth walls: a case study. Sol Energy 76(1\u20133):79\u201384. https:\/\/doi.org\/10.1016\/j.solener.2003.08.026","journal-title":"Sol Energy"},{"key":"3_CR107","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1016\/j.conbuildmat.2012.12.024","volume":"41","author":"E Vereecken","year":"2013","unstructured":"Vereecken E, Roels S (2013) Hygric performance of a massive masonry wall: how do the mortar joints influence the moisture flux? Constr Build Mater 41:697\u2013707","journal-title":"Constr Build Mater"},{"key":"3_CR108","unstructured":"Volhard F (1983) Leichtlehmbau: alter Baustoff - neue Technik. Karlsruhe"},{"key":"3_CR109","unstructured":"Volhard F (2016) Construire en terre all\u00e9g\u00e9e. Actes Sud"},{"key":"3_CR110","doi-asserted-by":"publisher","first-page":"338","DOI":"10.1016\/j.conbuildmat.2015.10.126","volume":"102","author":"O Vololonirina","year":"2016","unstructured":"Vololonirina O, Perrin B (2016) Inquiries into the measurement of vapour permeability of permeable materials\u2019, Construction and Building Materials. Constr Build Mater 102:338\u2013348. https:\/\/doi.org\/10.1016\/j.conbuildmat.2015.10.126","journal-title":"Constr Build Mater"},{"issue":"1","key":"3_CR111","first-page":"1","volume":"52","author":"DA De Vries","year":"1952","unstructured":"De Vries DA (1952) The thermal conductivity of soil. Mededelingen van de Landbouwhogeschool te Wageningen 52(1):1\u201373","journal-title":"Mededelingen van de Landbouwhogeschool te Wageningen"},{"key":"3_CR112","unstructured":"Vries DA, Kruger AJ (1966) On the value of the diffusion coefficient of water vapour in air. Ph\u00e9nom\u00e9nes de transport avec changement de phase dans les milieux poreux ou collo\u00efdaux, pp 561\u2013572"},{"key":"3_CR113","unstructured":"Walker P et al (2004) Rammed Earth: design and construction guidelines. In: Innovation Project: \u201cDeveloping Rammed Earth for UK Housing\u201d"},{"key":"3_CR114","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1016\/j.compgeo.2012.10.004","volume":"49","author":"A-N Zhou","year":"2013","unstructured":"Zhou A-N (2013) A contact angle-dependent hysteresis model for soil-water retention behaviour. Comput Geotech 49:36\u201342","journal-title":"Comput Geotech"},{"key":"3_CR115","unstructured":"Zillig W et al (2006) Liquid water transport in wood\u202f: towards a mesoscopic approach. In: Fazio P, Ge H, Rao J, Desmarais G (eds) Research in building physics engineering. CRC Press"}],"container-title":["RILEM State-of-the-Art Reports","Testing and Characterisation of Earth-based Building Materials and Elements"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-030-83297-1_3","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,11,26]],"date-time":"2021-11-26T13:07:18Z","timestamp":1637932038000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-030-83297-1_3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,11,27]]},"ISBN":["9783030832964","9783030832971"],"references-count":115,"URL":"https:\/\/doi.org\/10.1007\/978-3-030-83297-1_3","relation":{},"ISSN":["2213-204X","2213-2031"],"issn-type":[{"value":"2213-204X","type":"print"},{"value":"2213-2031","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,11,27]]},"assertion":[{"value":"27 November 2021","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}}]}}