{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,13]],"date-time":"2025-05-13T16:19:39Z","timestamp":1747153179019,"version":"3.40.5"},"publisher-location":"Cham","reference-count":17,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783031257940"},{"type":"electronic","value":"9783031257957"}],"license":[{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023]]},"DOI":"10.1007\/978-3-031-25795-7_23","type":"book-chapter","created":{"date-parts":[[2023,4,29]],"date-time":"2023-04-29T11:01:44Z","timestamp":1682766104000},"page":"293-301","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Building Thermal Modelling Used in DSF Design Applied in Ventilated Spaces"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5963-2107","authenticated-orcid":false,"given":"Eus\u00e9bio","family":"Concei\u00e7\u00e3o","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0346-6207","authenticated-orcid":false,"given":"Jo\u00e3o","family":"Gomes","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5322-8875","authenticated-orcid":false,"given":"M\u00aa. In\u00eas","family":"Concei\u00e7\u00e3o","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3243-3831","authenticated-orcid":false,"given":"M\u00aa. Manuela","family":"L\u00facio","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0201-3801","authenticated-orcid":false,"given":"Hazim","family":"Awbi","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2023,4,30]]},"reference":[{"key":"23_CR1","doi-asserted-by":"publisher","first-page":"1052","DOI":"10.1016\/j.rser.2016.01.130","volume":"60","author":"A Ghaffarianhoseini","year":"2016","unstructured":"A. Ghaffarianhoseini, A. Ghaffarianhoseini, U. Berardi, J. Tookey, D. Li, S. Kariminia, Exploring the advantages and challenges of double-skin facades (DSFs). Renew. Sust. Energ. Rev. 60, 1052\u20131065 (2016)","journal-title":"Renew. Sust. Energ. Rev."},{"key":"23_CR2","unstructured":"H. Poirazis, Double skin facades for office buildings \u2013 literature review. Report EBD-R--04\/3. Department of Construction and Architecture, Lund University, Sweden (2004)"},{"key":"23_CR3","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1016\/j.solener.2015.01.040","volume":"114","author":"F Xue","year":"2015","unstructured":"F. Xue, X. Li, A fast assessment method for thermal performance of naturally ventilated double-skin facades during cooling season. Sol. Energy 114, 303\u2013313 (2015)","journal-title":"Sol. Energy"},{"key":"23_CR4","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1007\/s12273-019-0511-y","volume":"12","author":"E Lucchino","year":"2019","unstructured":"E. Lucchino, F. Goia, G. Lobaccaro, G. Chaudhary, Modelling of double skin facades in whole-building energy simulation tools: A review of current practices and possibilities for future developments. Build. Simul. 12, 3\u201327 (2019)","journal-title":"Build. Simul."},{"key":"23_CR5","doi-asserted-by":"publisher","first-page":"310","DOI":"10.1016\/j.proeng.2015.08.432","volume":"118","author":"J Lee","year":"2015","unstructured":"J. Lee, M. Alshayeb, D. Chang, A study of shading device configuration on the natural ventilation efficiency and energy performance of a double skin facade. Procedia Eng. 118, 310\u2013317 (2015)","journal-title":"Procedia Eng."},{"key":"23_CR6","doi-asserted-by":"publisher","first-page":"4882","DOI":"10.3390\/en8064882","volume":"8","author":"J Parra","year":"2015","unstructured":"J. Parra, A. Guardo, E. Egusquiza, P. Alavedra, Thermal performance of ventilated double skin facades with venetian blinds. Energies 8, 4882\u20134898 (2015)","journal-title":"Energies"},{"key":"23_CR7","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1016\/j.energy.2018.09.175","volume":"165","author":"Y Luo","year":"2018","unstructured":"Y. Luo, Z. Ling, Z. Liu, L. Xie, X. Wang, J. Wu, Experimental study and performance evaluation of a PV-blind embedded double skin facade in winter season. Energy 165, 326\u2013342 (2018)","journal-title":"Energy"},{"issue":"3","key":"23_CR8","first-page":"287","volume":"9","author":"E Concei\u00e7\u00e3o","year":"2010","unstructured":"E. Concei\u00e7\u00e3o, A. Nunes, J. Gomes, M. L\u00facio, Application of a school building thermal response numerical model in the evolution of the adaptive thermal comfort level in Mediterranean environment. Int. J. Vent. 9(3), 287\u2013304 (2010)","journal-title":"Int. J. Vent."},{"issue":"5","key":"23_CR9","doi-asserted-by":"publisher","first-page":"871","DOI":"10.1016\/j.buildenv.2008.06.015","volume":"44","author":"E Concei\u00e7\u00e3o","year":"2009","unstructured":"E. Concei\u00e7\u00e3o, M. L\u00facio, A. Ruano, E. Crispim, Development of a temperature control model used in HVAC systems in school spaces in Mediterranean climate. Build. Environ. 44(5), 871\u2013877 (2009)","journal-title":"Build. Environ."},{"issue":"6","key":"23_CR10","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1177\/1420326X10377546","volume":"19","author":"E Concei\u00e7\u00e3o","year":"2010","unstructured":"E. Concei\u00e7\u00e3o, M. L\u00facio, Numerical study of the influence of opaque external trees with pyramidal shape on the thermal behaviour of a school building in summer conditions. Indoor Built. Environ. 19(6), 657\u2013667 (2010)","journal-title":"Indoor Built. Environ."},{"issue":"12","key":"23_CR11","doi-asserted-by":"publisher","first-page":"766","DOI":"10.3390\/atmos10120766","volume":"10","author":"E Concei\u00e7\u00e3o","year":"2019","unstructured":"E. Concei\u00e7\u00e3o, J. Gomes, H. Awbi, Influence of the airflow in a solar passive building on the indoor air quality and thermal comfort levels. Atmos. 10(12), 766 (2019)","journal-title":"Atmos."},{"key":"23_CR12","volume-title":"Thermal Comfort: Analysis and Applications in Environmental Engineering","author":"P Fanger","year":"1970","unstructured":"P. Fanger, Thermal Comfort: Analysis and Applications in Environmental Engineering (Danish Technical Press, Copenhagen, 1970)"},{"key":"23_CR13","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1016\/j.buildenv.2019.01.055","volume":"153","author":"T Cheung","year":"2019","unstructured":"T. Cheung, S. Schiavon, T. Parkinson, P. Li, G. Brager, Analysis of the accuracy on PMV \u2013 PPD model using the ASHRAE global thermal comfort database II. Build. Environ. 153, 205\u2013217 (2019)","journal-title":"Build. Environ."},{"key":"23_CR14","volume-title":"Ergonomics of the Thermal Environments\u2014Analytical Determination and Interpretation of Thermal Comfort Using Calculation of the PMV and PPD Indices and Local Thermal Comfort Criteria","author":"ISO 7730","year":"2005","unstructured":"ISO 7730, Ergonomics of the Thermal Environments\u2014Analytical Determination and Interpretation of Thermal Comfort Using Calculation of the PMV and PPD Indices and Local Thermal Comfort Criteria (International Standard Organization, Geneva, 2005)"},{"issue":"4","key":"23_CR15","first-page":"521","volume":"7","author":"E Concei\u00e7\u00e3o","year":"1997","unstructured":"E. Concei\u00e7\u00e3o, M. Silva, D. Viegas, Air quality inside the passenger compartment of a bus. J. Expo. Anal. Environ. Epidemiol. 7(4), 521\u2013534 (1997)","journal-title":"J. Expo. Anal. Environ. Epidemiol."},{"key":"23_CR16","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1016\/j.buildenv.2018.01.042","volume":"133","author":"A Asif","year":"2018","unstructured":"A. Asif, M. Zeeshan, M. Jahanzaib, Indoor temperature, relative humidity and CO2 levels assessment in academic buildings with different heating, ventilation and air-conditioning systems. Build. Environ. 133, 83\u201390 (2018)","journal-title":"Build. Environ."},{"key":"23_CR17","unstructured":"ANSI\/ASHRAE Standard 62-1, Ventilation for Acceptable Indoor Air Quality, American Society of Heating, Refrigerating and Air-Conditioning Engineers. Atlanta, (2016)"}],"container-title":["Sustainable and Digital Building"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-031-25795-7_23","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,29]],"date-time":"2023-04-29T11:13:19Z","timestamp":1682766799000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-031-25795-7_23"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023]]},"ISBN":["9783031257940","9783031257957"],"references-count":17,"URL":"https:\/\/doi.org\/10.1007\/978-3-031-25795-7_23","relation":{},"subject":[],"published":{"date-parts":[[2023]]},"assertion":[{"value":"30 April 2023","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}}]}}