{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,25]],"date-time":"2025-06-25T04:10:52Z","timestamp":1750824652508,"version":"3.41.0"},"publisher-location":"Cham","reference-count":22,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319599717"},{"type":"electronic","value":"9783319599724"}],"license":[{"start":{"date-parts":[[2017,7,26]],"date-time":"2017-07-26T00:00:00Z","timestamp":1501027200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018]]},"DOI":"10.1007\/978-3-319-59972-4_13","type":"book-chapter","created":{"date-parts":[[2017,7,25]],"date-time":"2017-07-25T03:57:31Z","timestamp":1500955051000},"page":"173-183","source":"Crossref","is-referenced-by-count":2,"title":["Robotic System Navigation Developed for Hip Resurfacing Prosthesis Surgery"],"prefix":"10.1007","author":[{"given":"P. M. B.","family":"Torres","sequence":"first","affiliation":[]},{"given":"P. J. S.","family":"Gon\u00e7alves","sequence":"additional","affiliation":[]},{"given":"J. M. M.","family":"Martins","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2017,7,26]]},"reference":[{"doi-asserted-by":"crossref","unstructured":"Qinjun, D.: The robot system of radio frequency ablation based on ultrasound navigation. In: 2010 2nd International Conference on Advanced Computer Control (ICACC), vol.\u00a04, pp. 542\u2013546 (2010)","key":"13_CR1","DOI":"10.1109\/ICACC.2010.5486860"},{"doi-asserted-by":"crossref","unstructured":"Luo, H., Jia, F., Zheng, Z., Hu, Q., Xu, Y.: An igstk-based surgical navigation system connected with medical robot. In: 2010 IEEE Youth Conference on Information Computing and Telecommunications (YC-ICT), pp. 49\u201352 (2010)","key":"13_CR2","DOI":"10.1109\/YCICT.2010.5713149"},{"doi-asserted-by":"crossref","unstructured":"Chen, X., Bao, N., Li, J., Kang, Y.: A review of surgery navigation system based on ultrasound guidance. In: 2012 International Conference on Information and Automation (ICIA), pp. 882\u2013886 (2012)","key":"13_CR3","DOI":"10.1109\/ICInfA.2012.6246906"},{"doi-asserted-by":"crossref","unstructured":"Otsuka, R., Sato, I., Nakamura, R.: Gpu based real-time surgical navigation system with three-dimensional ultrasound imaging for water-filled laparo-endoscope surgery. In: 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), pp. 2800\u20132803 (2012)","key":"13_CR4","DOI":"10.1109\/EMBC.2012.6346546"},{"doi-asserted-by":"crossref","unstructured":"Shang, P., Bai, X.: An ultrasound approach to digitizie bony landmarks in navigation assisted total hip arthroplasty. In: 2013 6th International Conference on Biomedical Engineering and Informatics (BMEI), pp. 342\u2013346 (2013)","key":"13_CR5","DOI":"10.1109\/BMEI.2013.6746960"},{"issue":"3","key":"13_CR6","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1109\/TBME.2015.2466591","volume":"63","author":"T Ungi","year":"2016","unstructured":"Ungi, T., Gauvin, G., Lasso, A., Yeo, C.T., Pezeshki, P., Vaughan, T., Carter, K., Rudan, J., Engel, C.J., Fichtinger, G.: Navigated breast tumor excision using electromagnetically tracked ultrasound and surgical instruments. IEEE Trans. Biomed. Eng. 63(3), 600\u2013606 (2016)","journal-title":"IEEE Trans. Biomed. Eng."},{"doi-asserted-by":"crossref","unstructured":"Brennecke, T., Woern, H.: Support and imaging tasks using an ultrasound-based navigation procedure for minimally invasive neck surgery: experiments and analyses. In: 2015 IEEE 24th International Symposium on Industrial Electronics (ISIE), pp. 584\u2013589 (2015)","key":"13_CR7","DOI":"10.1109\/ISIE.2015.7281533"},{"issue":"5","key":"13_CR8","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1108\/IR-12-2014-0435","volume":"42","author":"PMB Torres","year":"2015","unstructured":"Torres, P.M.B., Gon\u00e7alves, P.J.S., Martins, J.M.M.: Robotic motion compensation for bone movement, using ultrasound images. Ind. Robot: Int. J. 42(5), 466\u2013474 (2015)","journal-title":"Ind. Robot: Int. J."},{"unstructured":"Berry, D., Lieberman, J.: Surgery of the Hip. Elsevier (2013)","key":"13_CR9"},{"doi-asserted-by":"crossref","unstructured":"McMinn, D.J.W.: Modern Hip Resurfacing. Springer Science & Business Media (2009)","key":"13_CR10","DOI":"10.1007\/978-1-84800-088-9"},{"issue":"4","key":"13_CR11","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1053\/j.sart.2008.10.005","volume":"19","author":"Sarah Muirhead-Allwood","year":"2008","unstructured":"Muirhead-Allwood, Sarah, Sandiford, Nemandra, Kabir, Chindu: Total hip resurfacing as an alternative to total hip arthroplasty: indications and precautions. Seminars Arthroplast. 19(4), 274\u2013282 (2008)","journal-title":"Seminars Arthroplast."},{"unstructured":"Smith & Nephew: Smith and Nephew Birmingham hip resurfacing. Surgical Tech. (2008)","key":"13_CR12"},{"doi-asserted-by":"crossref","unstructured":"Shimmin, A.J., Back, D.: Femoral neck fractures following Birmingham hip resurfacing: a national review of 50 cases. J. Bone Jt. Surg. 87-B(4), 463\u2013464 (2005)","key":"13_CR13","DOI":"10.1302\/0301-620X.87B4.15498"},{"key":"13_CR14","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.ocl.2005.01.002","volume":"36","author":"AJ Shimmin","year":"2005","unstructured":"Shimmin, A.J., Bare, J., Back, D.L.: Complications associated with hip resurfacing arthroplasty. Orthop. Clin. North Am. 36, 187\u2013193 (2005)","journal-title":"Orthop. Clin. North Am."},{"key":"13_CR15","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1177\/145749691210100312","volume":"101","author":"T Tapaninen","year":"2012","unstructured":"Tapaninen, T., Kroger, H., Jurvelin, J., Venesmaa, P.: Femoral neck bone mineral density after resurfacing hip arthroplasty. Scand. J. Surg. 101, 211\u2013215 (2012)","journal-title":"Scand. J. Surg."},{"key":"13_CR16","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/j.arth.2012.04.035","volume":"28","author":"Gulraj S Matharu","year":"2013","unstructured":"Matharu, Gulraj S., McBryde, Callum W., Revell, Matthew P., Pynsent, Paul B.: Femoral neck fracture after Birmingham hip resurfacing arthroplasty: prevalence, time to fracture, and outcome after revision. J. Arthroplast. 28, 147\u2013153 (2013)","journal-title":"J. Arthroplast."},{"issue":"4","key":"13_CR17","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1302\/0301-620X.89B4.17893","volume":"89","author":"ET Davis","year":"2007","unstructured":"Davis, E.T., Gallie, P., Macgroarty, K., Waddele, J.P., Schemitsch, E.: The accuracy of image-free computer navigation in the placement of the femoral component of the Birmingham hip resurfacing. Bone Jt. J. 89(4), 557\u2013560 (2007)","journal-title":"Bone Jt. J."},{"issue":"7","key":"13_CR18","doi-asserted-by":"crossref","first-page":"713","DOI":"10.1243\/09544119JEIM284","volume":"221","author":"A Hodgson","year":"2007","unstructured":"Hodgson, A., Helmy, N., Masri, B.A., Greidanus, N.V., Inkpen, K.B., Duncan, C.P., Garbus, D.S., Anglin, C.: Comparative repeatability of guide-pin axis positioning in computer-assisted and manual femoral head resurfacing arthroplasty. Proc. Inst. Mech. Eng. 221(7), 713\u2013724 (2007)","journal-title":"Proc. Inst. Mech. Eng."},{"issue":"5","key":"13_CR19","doi-asserted-by":"crossref","first-page":"1341","DOI":"10.1007\/s11999-008-0299-z","volume":"467","author":"Muthu Ganapathi","year":"2009","unstructured":"Ganapathi, Muthu, Vendittoli, Pascal-Andr\u00e9, Lavigne, Martin, Gunther, Klaus-Peter: Femoral component positioning in hip resurfacing with and without navigation. Clin. Orthop. Relat. Res. 467(5), 1341\u20131347 (2009)","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"4","key":"13_CR20","doi-asserted-by":"crossref","first-page":"917","DOI":"10.1007\/s11999-008-0584-x","volume":"467","author":"Chris Bailey","year":"2009","unstructured":"Bailey, Chris, Gul, Rehan, Falworth, Mark, Zadow, Steven, Oakeshott, Roger: Component alignment in hip resurfacing using computer navigation. Clin. Orthop. Relat. Res. 467(4), 917\u2013922 (2009)","journal-title":"Clin. Orthop. Relat. Res."},{"doi-asserted-by":"crossref","unstructured":"Rusu, R.B., Cousins, S.: 3d is here: point cloud library (pcl). In: 2011 IEEE International Conference on Robotics and Automation (ICRA), pp. 1\u20134 (2011)","key":"13_CR21","DOI":"10.1109\/ICRA.2011.5980567"},{"unstructured":"Pires, P.M.S.: Position and Force Control of Lightweight Robot Manipulators for Orthopedic Surgery. PhD thesis, Instituto Superior T\u00e9cnico, Universidade de Lisboa (2014)","key":"13_CR22"}],"container-title":["Mechanisms and Machine Science","New Trends in Medical and Service Robots"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-59972-4_13","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,24]],"date-time":"2025-06-24T17:42:31Z","timestamp":1750786951000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-319-59972-4_13"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,7,26]]},"ISBN":["9783319599717","9783319599724"],"references-count":22,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-59972-4_13","relation":{},"ISSN":["2211-0984","2211-0992"],"issn-type":[{"type":"print","value":"2211-0984"},{"type":"electronic","value":"2211-0992"}],"subject":[],"published":{"date-parts":[[2017,7,26]]}}}