{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,9]],"date-time":"2024-09-09T17:14:07Z","timestamp":1725902047941},"publisher-location":"Cham","reference-count":22,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319603650"},{"type":"electronic","value":"9783319603667"}],"license":[{"start":{"date-parts":[[2017,6,23]],"date-time":"2017-06-23T00:00:00Z","timestamp":1498176000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018]]},"DOI":"10.1007\/978-3-319-60366-7_41","type":"book-chapter","created":{"date-parts":[[2017,6,22]],"date-time":"2017-06-22T02:06:22Z","timestamp":1498097182000},"page":"439-447","source":"Crossref","is-referenced-by-count":1,"title":["S-EMG of Forearm Muscles Activity in Conventional PC Mouse Use"],"prefix":"10.1007","author":[{"given":"Miguel L.","family":"Louren\u00e7o","sequence":"first","affiliation":[]},{"given":"Denis A.","family":"Coelho","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2017,6,23]]},"reference":[{"key":"41_CR1","unstructured":"Nwaigwe, A.F.: Ergonomics Considerations in IT-Enabled Computer-Aided Design for Discrete Manufactured Products. Ph.D. Thesis. University of Pittsburgh, EUA (2015)"},{"key":"41_CR2","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/S1050-6411(00)00053-5","volume":"11","author":"K S\u00f8gaard","year":"2006","unstructured":"S\u00f8gaard, K., Sjogaard, G., Finsen, L., Olsen, H.B., Christensen, H.: Motor unit activity during stereotyped finger tasks and computer mouse work. J. Electromyogr. Kinesiol. 11, 197\u2013206 (2006)","journal-title":"J. Electromyogr. Kinesiol."},{"key":"41_CR3","doi-asserted-by":"crossref","unstructured":"Agarabi, M., Bonato P., De Luca C.J.: A sEMG-based method for assessing the design of computer mice. In: Conference Proceedings: Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference 4, pp. 2450\u20132453 (2004)","DOI":"10.1109\/IEMBS.2004.1403708"},{"issue":"4","key":"41_CR4","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1518\/001872007X215665","volume":"49","author":"D Lee","year":"2007","unstructured":"Lee, D., Fleisher, J., McLoone, H., Kotani, K., Dennerlein, J.: Alternative computer mouse design to reduce static finger extensor muscle activity. Hum. Factors 49(4), 573\u2013584 (2007)","journal-title":"Hum. Factors"},{"key":"41_CR5","doi-asserted-by":"crossref","first-page":"418","DOI":"10.5271\/sjweh.364","volume":"24","author":"C Jensen","year":"1998","unstructured":"Jensen, C., Borg, V., Finsen, L., Hansen, K., Juul-Kristensen, B., Christensen, H.: Job demands, muscle activity and musculoskeletal symptoms in relation to work with the computer mouse. Scand. J. Work Environ. Health 24, 418\u2013424 (1998)","journal-title":"Scand. J. Work Environ. Health"},{"key":"41_CR6","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.1080\/00140139408964904","volume":"37","author":"L Karlqvist","year":"1994","unstructured":"Karlqvist, L., Hagberg, M., Selin, K.: Variation in upper limb posture and movement during word processing with and without mouse use. Ergonomics 37, 1261\u20131267 (1994)","journal-title":"Ergonomics"},{"key":"41_CR7","doi-asserted-by":"crossref","first-page":"1350","DOI":"10.1080\/001401399184992","volume":"42","author":"P Keir","year":"1999","unstructured":"Keir, P., Bach, J., Rempel, D.: Effects of computer mouse design and task on carpal tunnel pressure. Ergonomics 42, 1350\u20131360 (1999)","journal-title":"Ergonomics"},{"key":"41_CR8","series-title":"Advances in Intelligent Systems and Computing","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1007\/978-3-319-41956-5_2","volume-title":"Advances in Human Factors and System Interactions","author":"LM Louren\u00e7o","year":"2017","unstructured":"Louren\u00e7o, L.M., Pitarma, R.A., Coelho, D.A.: Horizontal and vertical handheld pointing devices comparison for increasing human systems integration at the design stage. In: Nunes, I. (ed.) Advances in Human Factors and System Interactions. Advances in Intelligent Systems and Computing, vol. 497, pp. 15\u201324. Springer, Cham (2017)"},{"key":"41_CR9","unstructured":"Louren\u00e7o, M.L.: Desenvolvimento e An\u00e1lise Ergon\u00f3mica de Dispositivos Manuais Apontadores para Computador [Development and Ergonomic Analysis of Computer Handheld Pointing Devices]. Doctoral Dissertation. Industrial Engineering and Management. School of Engineering. Universidade da Beira Interior, Covilh\u00e3, Portugal (2016)"},{"issue":"1","key":"41_CR10","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1177\/0018720808329843","volume":"51","author":"A Houwink","year":"2009","unstructured":"Houwink, A., Hengel, K.M.O., Odell, D., Dennerlein, J.T.: Providing training enhances the biomechanical improvements of an alternative computer mouse design. Hum. Factors J. Hum. Factors Ergon. Soc. 51(1), 46\u201355 (2009)","journal-title":"Hum. Factors J. Hum. Factors Ergon. Soc."},{"issue":"6","key":"41_CR11","doi-asserted-by":"crossref","first-page":"2205","DOI":"10.1007\/s00421-011-2198-3","volume":"112","author":"HM Chen","year":"2012","unstructured":"Chen, H.M., Lee, C.S., Cheng, C.H.: The weight of computer mouse affects the wrist motion and forearm muscle activity during fast operation speed task. Eur. J. Appl. Physiol. 112(6), 2205\u20132212 (2012)","journal-title":"Eur. J. Appl. Physiol."},{"key":"41_CR12","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1016\/j.apergo.2014.10.003","volume":"47","author":"MYC Lin","year":"2015","unstructured":"Lin, M.Y.C., Young, J.G., Dennerlein, J.T.: Evaluating the effect of four different pointing device designs on upper extremity posture and muscle activity during mousing tasks. Appl. Ergon. 47, 259\u2013264 (2015)","journal-title":"Appl. Ergon."},{"key":"41_CR13","volume-title":"Cram\u2019s Introduction to Surface Electromyography","author":"E Criswell","year":"2011","unstructured":"Criswell, E.: Cram\u2019s Introduction to Surface Electromyography, 2nd edn. Jones and Bartlett Publishers, Burlington, MA (2011)","edition":"2"},{"key":"41_CR14","unstructured":"ISO 9241-400: Ergonomics of Human\u2013System Interaction. Part 400: Principles and Requirements for Physical Input Devices International Organization for Standardization (ISO), Geneva, Switzerland (2007)"},{"key":"41_CR15","unstructured":"Rempel, D.M.: Personal Communication Regarding Appropriate Surface EMG Equipment and Selection of Muscles for Monitoring. Professor of Occupational Medicine, University of California, San Francisco CA (2013\u20132015)"},{"key":"41_CR16","volume-title":"Anatomical Guide for the Electromyographer: The Limbs and Trunk","author":"A Perotto","year":"1994","unstructured":"Perotto, A.: Anatomical Guide for the Electromyographer: The Limbs and Trunk. Charles C. Thomas, Springfield, IL (1994)"},{"issue":"1","key":"41_CR17","doi-asserted-by":"crossref","first-page":"59","DOI":"10.3233\/WOR-131604","volume":"45","author":"JG Young","year":"2013","unstructured":"Young, J.G., Trudeau, M.B., Odell, D., Marinelli, K., Dennerlein, J.T.: Wrist and shoulder posture and muscle activity during touch-screen tablet use: effects of usage configuration, tablet type, and interacting hand. Work 45(1), 59\u201371 (2013)","journal-title":"Work"},{"issue":"4","key":"41_CR18","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1007\/BF00421518","volume":"40","author":"M Hagberg","year":"1979","unstructured":"Hagberg, M.: The amplitude distribution of surface EMG in static and intermittent static muscular performance. Eur. J. Appl. Physiol. Occup. Physiol. 40(4), 265\u2013272 (1979)","journal-title":"Eur. J. Appl. Physiol. Occup. Physiol."},{"key":"41_CR19","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1007\/BF00635988","volume":"57","author":"B Jonsson","year":"1988","unstructured":"Jonsson, B.: The static load component in muscle work. Eur. J. Appl. Physiol. 57, 305\u2013310 (1988)","journal-title":"Eur. J. Appl. Physiol."},{"key":"41_CR20","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.apergo.2006.12.008","volume":"39","author":"DL Lee","year":"2008","unstructured":"Lee, D.L., McLoone, H., Dennerlein, J.T.: Observed finger behaviour during computer mouse use. Appl. Ergon. 39, 107\u2013113 (2008)","journal-title":"Appl. Ergon."},{"key":"41_CR21","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1201\/b21172-66","volume-title":"Occupational Safety and Hygiene IV","author":"LM Louren\u00e7o","year":"2016","unstructured":"Louren\u00e7o, L.M., Pitarma, R.A., Coelho, D.A.: Association of hand size with usability assessment parameters of a standard handheld computer pointing device. In: Arezes, P.M., Baptista, J.S., Barroso, M.P., Carneiro, P., Cordeiro, P., Costa, N., Melo, R.B., Miguel, A.S., Perestrelo, G. (eds.) Occupational Safety and Hygiene IV, pp. 339\u2013343. Balkena and CRC Press, Boca Raton (2016)"},{"key":"41_CR22","unstructured":"Louren\u00e7o, L.M., Pitarma, R.A., Coelho, D.A.: Ergonomic development of a computer pointing device \u2013 a departure from the conventional PC mouse towards CAD users. In: Proceedings of the 19th Triennial Congress of the International Ergonomics Association, Melbourne, Australia (2015)"}],"container-title":["Advances in Intelligent Systems and Computing","Advances in Human Factors and Systems Interaction"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-60366-7_41","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,10,10]],"date-time":"2020-10-10T16:53:17Z","timestamp":1602348797000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-319-60366-7_41"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,6,23]]},"ISBN":["9783319603650","9783319603667"],"references-count":22,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-60366-7_41","relation":{},"ISSN":["2194-5357","2194-5365"],"issn-type":[{"type":"print","value":"2194-5357"},{"type":"electronic","value":"2194-5365"}],"subject":[],"published":{"date-parts":[[2017,6,23]]}}}