{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T00:22:58Z","timestamp":1742948578141,"version":"3.40.3"},"publisher-location":"Cham","reference-count":16,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319681948"},{"type":"electronic","value":"9783319681955"}],"license":[{"start":{"date-parts":[[2017,10,13]],"date-time":"2017-10-13T00:00:00Z","timestamp":1507852800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018]]},"DOI":"10.1007\/978-3-319-68195-5_101","type":"book-chapter","created":{"date-parts":[[2017,10,12]],"date-time":"2017-10-12T01:14:26Z","timestamp":1507770866000},"page":"930-936","source":"Crossref","is-referenced-by-count":3,"title":["Visualization and Measurement of the Cell-Free Layer (CFL) in a Microchannel Network"],"prefix":"10.1007","author":[{"given":"D.","family":"Bento","sequence":"first","affiliation":[]},{"given":"C. S.","family":"Fernandes","sequence":"additional","affiliation":[]},{"given":"A. I.","family":"Pereira","sequence":"additional","affiliation":[]},{"given":"J. M.","family":"Miranda","sequence":"additional","affiliation":[]},{"given":"R.","family":"Lima","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2017,10,13]]},"reference":[{"key":"101_CR1","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1146\/annurev.fluid.37.042604.133933","volume":"37","author":"AS Popel","year":"2005","unstructured":"Popel, A.S., Johnson, P.C.: Microcirculation and Hemorheology. Annu. Rev. Fluid Mech. 37, 43\u201369 (2005)","journal-title":"Annu. Rev. Fluid Mech."},{"key":"101_CR2","doi-asserted-by":"crossref","unstructured":"Lima, R., Ishikawa, T., Imai, Y., Yamaguchi, T.: Blood flow behavior in microchannels: past, current and future trends. In: Dias, R., et al. (ed.) Single and two-Phase Flows on Chemical and Biomedical Engineering, pp. 513\u2013547. Bentham Science (2012)","DOI":"10.2174\/978160805295011201010513"},{"key":"101_CR3","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.1016\/0021-9290(94)90052-3","volume":"27","author":"N Tateishi","year":"1994","unstructured":"Tateishi, N., Suzuki, Y., Soutani, M., Maeda, N.: Flow dynamics of erythrocytes in microvessels of isolated rabbit mesentery: cell-free layer and flow resistance. J. Biomech. 27, 1119\u20131125 (1994)","journal-title":"J. Biomech."},{"key":"101_CR4","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1080\/10739680600556878","volume":"13","author":"S Kim","year":"2006","unstructured":"Kim, S., Kong, R.L., Popel, A.S., Intaglietta, M., Johnson, P.C.: A computer-based method for determination of the cell-free layer width in microcirculation. Microcirculation 13, 199\u2013207 (2006)","journal-title":"Microcirculation"},{"key":"101_CR5","doi-asserted-by":"crossref","first-page":"e99615","DOI":"10.1371\/journal.pone.0099615","volume":"9","author":"S Dietzel","year":"2014","unstructured":"Dietzel, S., Pircher, J., Nekolla, A.K., et al.: Label-free determination of hemodynamic parameters in the microcirculaton with third harmonic generation microscopy. PLoS ONE 9, e99615 (2014)","journal-title":"PLoS ONE"},{"key":"101_CR6","doi-asserted-by":"crossref","unstructured":"Namgung, B., Liang, L.H., Kim, S.: Physiological significance of cell-free layer and experimental determination of its width in microcirculatory vessels. In: Lima, R., Ishikawa, T., Imai, Y., Oliveira, M.S.N. (eds.) Visualization and Simulation of Complex Flows in Biomedical Engineering, vol. 12, pp. 75\u201387. Springer, New York (2014)","DOI":"10.1007\/978-94-007-7769-9_4"},{"key":"101_CR7","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.mvr.2011.11.003","volume":"83","author":"PK Ong","year":"2012","unstructured":"Ong, P.K., Jain, S., Kim, S.: Spatio-temporal variations in cell-free layer formation near bifurcations of small arterioles. Microvasc. Res. 83, 118\u2013125 (2012)","journal-title":"Microvasc. Res."},{"key":"101_CR8","doi-asserted-by":"crossref","first-page":"083001","DOI":"10.1088\/0960-1317\/25\/8\/083001","volume":"25","author":"S Tripathi","year":"2015","unstructured":"Tripathi, S., Bala Varun Kumar, Y.V., Prabhakar, A., Joshi, S.S., Agrawal, A.: Passive blood plasma separation at the microscale: a review of design principles and microdevices. J. Micromech. Microeng. 25, 083001 (2015)","journal-title":"J. Micromech. Microeng."},{"issue":"11","key":"101_CR9","doi-asserted-by":"crossref","first-page":"2280","DOI":"10.1016\/j.jbiomech.2015.11.031","volume":"49","author":"V Faustino","year":"2016","unstructured":"Faustino, V., Catarino, S.O., Lima, R., Minas, G.: Biomedical microfluidic devices by using low-cost fabrication techniques: a review. J. Biomech. 49(11), 2280\u20132292 (2016)","journal-title":"J. Biomech."},{"key":"101_CR10","doi-asserted-by":"crossref","first-page":"121","DOI":"10.3390\/mi6010121","volume":"6","author":"E Pinto","year":"2014","unstructured":"Pinto, E., Faustino, V., Rodrigues, R., et al.: A rapid and low-cost nonlithographic method to fabricate biomedical microdevices for blood flow analysis. Micromachines 6, 121\u2013135 (2014)","journal-title":"Micromachines"},{"key":"101_CR11","doi-asserted-by":"crossref","unstructured":"Lopes, A.R., et al.: Low cost microfluidic device for partial cell separation: micromilling approach. In: Proceedings of the IEEE International Conference on Industrial Technology. Seville, Spain (2015)","DOI":"10.1109\/ICIT.2015.7125594"},{"key":"101_CR12","first-page":"367","volume":"7","author":"D Pinho","year":"2013","unstructured":"Pinho, D., Yaginuma, T., Lima, R.: A microfluidic device for partial cell separation and deformability assessment. Bio. Chip. J. 7, 367\u2013374 (2013)","journal-title":"Bio. Chip. J."},{"issue":"1","key":"101_CR13","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1007\/s10544-016-0138-z","volume":"19","author":"D Bento","year":"2017","unstructured":"Bento, D., Sousa, L., Yaginuma, T., Garcia, V., Lima, R., Miranda, J.M.: Microbubble moving in blood flow in microchannels: effect on the cell-free layer and cell local concentration. Biomed. Microdevice 19(1), 6 (2017)","journal-title":"Biomed. Microdevice"},{"key":"101_CR14","doi-asserted-by":"crossref","first-page":"44120","DOI":"10.1063\/1.3672689","volume":"5","author":"V Leble","year":"2011","unstructured":"Leble, V., Lima, R., Dias, R., et al.: Asymmetry of red blood cell motions in a microchannel with a diverging and converging bifurcation. Biomicrofluidics 5, 44120 (2011)","journal-title":"Biomicrofluidics"},{"key":"101_CR15","first-page":"36","volume":"11","author":"M Abramoff","year":"2004","unstructured":"Abramoff, M., Magelhaes, P., Ram, S.: Image processing with image. J. Int. J. Biophotonics 11, 36\u201342 (2004)","journal-title":"J. Int. J. Biophotonics"},{"key":"101_CR16","doi-asserted-by":"publisher","unstructured":"Bento, D., Pereira, A.I., Lima, J., Miranda, J.M., Lima, R.: Cell-free layer measurements of in vitro blood flow in a microfluidic network: an automatic and manual approach. In: Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization (2017). doi:\n10.1080\/21681163.2017.1329029","DOI":"10.1080\/21681163.2017.1329029"}],"container-title":["Lecture Notes in Computational Vision and Biomechanics","VipIMAGE 2017"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-68195-5_101","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,11,8]],"date-time":"2017-11-08T01:47:58Z","timestamp":1510105678000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-319-68195-5_101"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,10,13]]},"ISBN":["9783319681948","9783319681955"],"references-count":16,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-68195-5_101","relation":{},"ISSN":["2212-9391","2212-9413"],"issn-type":[{"type":"print","value":"2212-9391"},{"type":"electronic","value":"2212-9413"}],"subject":[],"published":{"date-parts":[[2017,10,13]]}}}