{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,10]],"date-time":"2024-09-10T18:36:03Z","timestamp":1725993363191},"publisher-location":"Cham","reference-count":42,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319753850"},{"type":"electronic","value":"9783319753867"}],"license":[{"start":{"date-parts":[[2018,9,27]],"date-time":"2018-09-27T00:00:00Z","timestamp":1538006400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019]]},"DOI":"10.1007\/978-3-319-75386-7_1","type":"book-chapter","created":{"date-parts":[[2018,9,26]],"date-time":"2018-09-26T18:24:43Z","timestamp":1537986283000},"page":"1-6","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Introduction"],"prefix":"10.1007","author":[{"given":"Eva","family":"Barreira","sequence":"first","affiliation":[]},{"given":"Ricardo M. S. F.","family":"Almeida","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2018,9,27]]},"reference":[{"key":"1_CR1","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1016\/j.apenergy.2011.12.054","volume":"97","author":"F Asdrubali","year":"2012","unstructured":"Asdrubali F, Baldinelli G, Bianchi F (2012) A quantitative methodology to evaluate thermal bridges in buildings. Appl Energy 97:365\u2013373","journal-title":"Appl Energy"},{"key":"1_CR2","volume-title":"Standard practice for thermographic inspection of insulation installations in envelope cavities of frame buildings","author":"ASTM-C 1060\u201390","year":"2003","unstructured":"ASTM-C 1060\u201390 (2003) Standard practice for thermographic inspection of insulation installations in envelope cavities of frame buildings. ASTM International, USA"},{"issue":"7","key":"1_CR3","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1016\/S0378-7788(02)00210-4","volume":"35","author":"N Avdelidis","year":"2003","unstructured":"Avdelidis N, Moropoulou A (2003) Emissivity considerations in building thermography. Energy Buildings 35(7):663\u2013667","journal-title":"Energy Buildings"},{"issue":"1","key":"1_CR4","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1016\/j.culher.2003.07.002","volume":"5","author":"N Avdelidis","year":"2004","unstructured":"Avdelidis N, Moropoulou A (2004) Applications of infrared thermography for the investigation of historic structures. J Cult Heritage 5(1):119\u2013127","journal-title":"J Cult Heritage"},{"issue":"3","key":"1_CR5","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1016\/S1350-4495(02)00212-8","volume":"44","author":"N Avdelidis","year":"2003","unstructured":"Avdelidis N, Moropoulou A, Theoulakis P (2003) Detection of water deposits and movement in porous materials by infrared imaging. Infrared Phys Technol 44(3):183\u2013190","journal-title":"Infrared Phys Technol"},{"key":"1_CR6","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1016\/j.infrared.2013.03.006","volume":"60","author":"S Bagavathiappan","year":"2013","unstructured":"Bagavathiappan S, Lahiri B, Saravanan T, Jayakumar J (2013) Infrared thermography for condition monitoring\u2014A review. Infrared Phys Technol 60:35\u201355","journal-title":"Infrared Phys Technol"},{"issue":"2","key":"1_CR7","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1016\/S0378-7788(01)00105-0","volume":"34","author":"C Balaras","year":"2002","unstructured":"Balaras C, Argiriou A (2002) Infrared thermography for building diagnostics. Energy Buildings 34(2):171\u2013183","journal-title":"Energy Buildings"},{"key":"1_CR8","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1016\/j.conbuildmat.2016.02.026","volume":"110","author":"E Barreira","year":"2016","unstructured":"Barreira E, Almeida RMSF, Delgado JMPQ (2016) Infrared thermography for assessing moisture related phenomena in building components. Constr Building Mater 110:251\u2013269","journal-title":"Constr Building Mater"},{"key":"1_CR9","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1016\/j.egypro.2017.09.757","volume":"132","author":"E Barreira","year":"2017","unstructured":"Barreira E, Almeida RMSF, Ferreira JPB (2017a) Assessing the humidification process of lightweight concrete specimens through infrared thermography. Energy Procedia 132:213\u2013218","journal-title":"Energy Procedia"},{"key":"1_CR10","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1016\/j.enbuild.2017.02.009","volume":"140","author":"E Barreira","year":"2017","unstructured":"Barreira E, Almeida RMSF, Moreira M (2017b) An infrared thermography passive approach to assess the effect of leakage points in buildings. Energy Buildings 140:224\u2013235","journal-title":"Energy Buildings"},{"issue":"1","key":"1_CR11","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1016\/j.conbuildmat.2005.06.049","volume":"21","author":"E Barreira","year":"2007","unstructured":"Barreira E, Freitas VP (2007) Evaluation of building materials using infrared thermograph. Constr Building Mater 21(1):218\u2013224","journal-title":"Constr Building Mater"},{"issue":"1","key":"1_CR12","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1108\/SS-05-2014-0021","volume":"33","author":"E Bauer","year":"2015","unstructured":"Bauer E, Freitas VP, Mustelier N, Barreira E, Freitas SS (2015) Infrared thermography\u2014evaluation of the results reproducibility. Structural Survey 33(1):20\u201335","journal-title":"Structural Survey"},{"issue":"1","key":"1_CR13","first-page":"111","volume":"69","author":"P Bison","year":"2011","unstructured":"Bison P, Cadelano G, Capineri L, Capitani D, Casellato U, Faroldi P, Grinzato E, Ludwig N, Olmi R, Priori S, Proietti N, Rosina E, Ruggeri R, Sansonetti A, Soroldoni L, Valentini M (2011a) Limits and advantages of different techniques for testing moisture content in masonry. Mater Eval 69(1):111\u2013116","journal-title":"Mater Eval"},{"issue":"2","key":"1_CR14","doi-asserted-by":"publisher","first-page":"221","DOI":"10.3166\/qirt.8.221-238","volume":"8","author":"P Bison","year":"2011","unstructured":"Bison P, Cadelano G, Grinzato E (2011b) Thermographic signal reconstruction with periodic temperature variation applied to moisture classification. Quant Infrared Thermography J 8(2):221\u2013238","journal-title":"Quant Infrared Thermography J"},{"issue":"314","key":"1_CR15","first-page":"020","volume":"64","author":"MS Camino","year":"2014","unstructured":"Camino MS, Le\u00f3n FJ, Llorente A, Olivar JM (2014) Evaluation of the behaviour of brick tile masonry and mortar due to capillary rise of moisture. Mater de Construcci\u00f3n 64(314):020","journal-title":"Mater de Construcci\u00f3n"},{"key":"1_CR16","doi-asserted-by":"publisher","first-page":"1845","DOI":"10.1016\/j.enbuild.2011.03.029","volume":"43","author":"F Cerdeira","year":"2011","unstructured":"Cerdeira F, V\u00e1zquez ME, Collazo J, Granada E (2011) Applicability of infrared thermography to the study of the behaviour of stone panel as building envelopes. Energy Buildings 43:1845\u20131851","journal-title":"Energy Buildings"},{"issue":"2","key":"1_CR17","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1108\/02630809810219669","volume":"16","author":"M Chew","year":"1998","unstructured":"Chew M (1998) Assessing building fa\u00e7ades using infra-red thermography. Structural Survey 16(2):81\u201386","journal-title":"Structural Survey"},{"key":"1_CR18","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1016\/j.conbuildmat.2013.10.085","volume":"51","author":"E Edis","year":"2014","unstructured":"Edis E, Flores-Colen I, Brito J (2014) Passive thermographic detection of moisture problems in fa\u00e7ades with adhered ceramic cladding. Constr Building Mater 51:187\u2013197","journal-title":"Constr Building Mater"},{"key":"1_CR19","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1016\/j.buildenv.2015.07.027","volume":"94","author":"E Edis","year":"2015","unstructured":"Edis E, Flores-Colen I, Brito J (2015) Quasi-quantitative infrared thermographic detection of moisture variation in facades with adhered ceramic cladding using principal component analysis. Building Environ 94:97\u2013108","journal-title":"Building Environ"},{"key":"1_CR20","volume-title":"Thermal performance of buildings\u2014Qualitative detection of thermal irregularities in building envelops\u2014Infrared method","author":"EN 13187","year":"1998","unstructured":"EN 13187 (1998) Thermal performance of buildings\u2014Qualitative detection of thermal irregularities in building envelops\u2014Infrared method. European Committee for Standardization, Belgium"},{"key":"1_CR21","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1016\/j.conbuildmat.2014.07.094","volume":"70","author":"SS Freitas","year":"2014","unstructured":"Freitas SS, Freitas VP, Barreira E (2014) Detection of fa\u00e7ade plaster detachments using infrared thermography\u2014A non-destructive technique. Construction Building Mater 70:80\u201387","journal-title":"Construction Building Mater"},{"issue":"18","key":"1_CR22","doi-asserted-by":"publisher","first-page":"1770","DOI":"10.1080\/09500341003731597","volume":"57","author":"E Grinzato","year":"2010","unstructured":"Grinzato E, Cadelano G, Bison P (2010) Moisture map by IR thermography. J Modern Optics 57(18):1770\u20131778","journal-title":"J Modern Optics"},{"issue":"1","key":"1_CR23","first-page":"97","volume":"69","author":"E Grinzato","year":"2011","unstructured":"Grinzato E, Ludwig N, Cadelano G, Bertucci M, Gargano M, Bison P (2011) Infrared thermography for moisture detection: a laboratory study and in-situ test. Mater Eval 69(1):97\u2013104","journal-title":"Mater Eval"},{"key":"1_CR24","volume-title":"A practical guide for infra-red thermography for building surveys","author":"J Hart","year":"2001","unstructured":"Hart J (2001) A practical guide for infra-red thermography for building surveys. BRE, UK"},{"key":"1_CR25","volume-title":"Thermal Insulation\u2014Qualitative detection of thermal irregularities in building envelopes\u2014Infrared method","author":"ISO 6781","year":"1983","unstructured":"ISO 6781 (1983) Thermal Insulation\u2014Qualitative detection of thermal irregularities in building envelopes\u2014Infrared method. International Organization for Standardization, Switzerland"},{"key":"1_CR26","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1016\/j.buildenv.2013.05.014","volume":"67","author":"D Katunsky","year":"2013","unstructured":"Katunsky D, Korjenic A, Katunska J, Lopusniak M, Korjenic S, Doroudiani S (2013) Analysis of thermal energy demand and saving in industrial buildings: a case study in Slovakia. Building Environ 67:138\u2013146","journal-title":"Building Environ"},{"key":"1_CR27","doi-asserted-by":"crossref","unstructured":"Lai WL, Poon CS (2012) Boundary and size estimation of debonds in external wall finishes of high-rise buildings using Infrared thermography, In: Proceedings of QIRT2012\u201411th international conference on quantitative infrared thermography, Naples, Italy, June 2012","DOI":"10.21611\/qirt.2012.279"},{"key":"1_CR28","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1016\/j.enbuild.2018.02.050","volume":"168","author":"C Lerma","year":"2018","unstructured":"Lerma C, Barreira E, Almeida RMSF (2018) A discussion concerning active infrared thermography in the evaluation of buildings air infiltration. Energy Buildings 168:56\u201366","journal-title":"Energy Buildings"},{"issue":"5","key":"1_CR29","doi-asserted-by":"publisher","first-page":"2190","DOI":"10.1016\/j.conbuildmat.2010.10.007","volume":"25","author":"J Lerma","year":"2011","unstructured":"Lerma J, Cabrelles M, Portal\u00e9s C (2011) Multitemporal thermal analysis to detect moisture on a building fa\u00e7ade. Construction Building Mater 25(5):2190\u20132197","journal-title":"Construction Building Mater"},{"issue":"313","key":"1_CR30","doi-asserted-by":"publisher","first-page":"009","DOI":"10.3989\/mc.2013.06612","volume":"64","author":"C Lerma","year":"2014","unstructured":"Lerma C, Mas \u00c1, Gil E, Vercher J, Pe\u00f1alver MJ (2014) Pathology of building materials in historic buildings. Relationship between laboratory testing and infrared thermography. Materiales de Construcci\u00f3n 64(313):009","journal-title":"Materiales de Construcci\u00f3n"},{"key":"1_CR31","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4471-1995-1","volume-title":"Nondestructive evaluation of materials by infrared thermography","author":"X Maldague","year":"1993","unstructured":"Maldague X (1993) Nondestructive evaluation of materials by infrared thermography. Springer-Verlag, Germany"},{"key":"1_CR32","volume-title":"Nondestructive testing monographs and tracts. Infrared methodology and technology","author":"X Maldague","year":"1994","unstructured":"Maldague X (1994) Nondestructive testing monographs and tracts. Infrared methodology and technology. Gordon and Breach Science Publishers, Switzerland"},{"key":"1_CR33","volume-title":"Theory and practice of infrared technology for nondestructive testing","author":"X Maldague","year":"2001","unstructured":"Maldague X (2001) Theory and practice of infrared technology for nondestructive testing. Wiley-Interscience Publication, USA"},{"key":"1_CR34","unstructured":"Maldague X (2002) Applications of infrared thermography in nondestructive evaluation, Research Working Paper No. G1K7P4, University of Laval, Electrical and Computing Engineering Department, Canada"},{"key":"1_CR35","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1016\/j.conbuildmat.2014.11.039","volume":"75","author":"A Menezes","year":"2015","unstructured":"Menezes A, Gomes MG, Flores-Colen I (2015) In-situ assessment of physical performance and degradation analysis of rendering walls. Constr Building Mater 75:283\u2013292","journal-title":"Constr Building Mater"},{"key":"1_CR36","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1016\/j.culher.2012.05.005","volume":"14","author":"D Paoletti","year":"2013","unstructured":"Paoletti D, Ambrosini D, Sfarra S, Bisegna F (2013) Preventive thermographic diagnosis of historical buildings for consolidation. J Cultural Heritage 14:116\u2013121","journal-title":"J Cultural Heritage"},{"key":"1_CR37","volume-title":"Building envelope\u2014Infrared thermography\u2014Preventative roof maintenance","author":"G Rajewski","year":"1996","unstructured":"Rajewski G, Devine G (1996) Building envelope\u2014Infrared thermography\u2014Preventative roof maintenance. Building Operator Association, Canada"},{"issue":"5","key":"1_CR38","first-page":"41","volume":"82","author":"P Rao","year":"2008","unstructured":"Rao P (2008) Infrared thermography and its applications to civil engineering. Indian Concrete J 82(5):41\u201350","journal-title":"Indian Concrete J"},{"key":"1_CR39","first-page":"22","volume":"3827","author":"E Rosina","year":"1999","unstructured":"Rosina E, Ludwig N (1999) Optimal thermographic procedures for moisture analysis in building materials. Soc Photographic Instrumentation Eng (SPIE) 3827:22\u201333","journal-title":"Soc Photographic Instrumentation Eng (SPIE)"},{"key":"1_CR40","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1016\/j.culher.2015.07.011","volume":"18","author":"S Sfarra","year":"2016","unstructured":"Sfarra S, Ibarra-Castanedo C, Tortorac M, Arrizzac L, Cerichellic G, Nardia I, Maldague X (2016) Diagnostics of wall paintings: A smart and reliable approach. J Cultural Heritage 18:229\u2013241","journal-title":"J Cultural Heritage"},{"key":"1_CR41","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1016\/j.enbuild.2013.07.051","volume":"66","author":"T Taylor","year":"2013","unstructured":"Taylor T, Counsell J, Gill S (2013) Energy efficiency is more than skin deep: Improving construction quality control in new-build housing using thermography. Energy Buildings 66:222\u2013231","journal-title":"Energy Buildings"},{"key":"1_CR42","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.ndteint.2013.09.002","volume":"61","author":"V Vavilov","year":"2014","unstructured":"Vavilov V (2014) Noise-limited thermal\/infrared nondestructive testing. NDT E Int 61:16\u201323","journal-title":"NDT E Int"}],"container-title":["SpringerBriefs in Applied Sciences and Technology","Infrared Thermography for Building Moisture Inspection"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-75386-7_1","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,24]],"date-time":"2019-10-24T23:08:45Z","timestamp":1571958525000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-319-75386-7_1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,9,27]]},"ISBN":["9783319753850","9783319753867"],"references-count":42,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-75386-7_1","relation":{},"ISSN":["2191-530X","2191-5318"],"issn-type":[{"type":"print","value":"2191-530X"},{"type":"electronic","value":"2191-5318"}],"subject":[],"published":{"date-parts":[[2018,9,27]]}}}