{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,11]],"date-time":"2024-09-11T04:45:49Z","timestamp":1726029949968},"publisher-location":"Cham","reference-count":32,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319761701"},{"type":"electronic","value":"9783319761725"}],"license":[{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019]]},"DOI":"10.1007\/978-3-319-76172-5_10","type":"book-chapter","created":{"date-parts":[[2019,3,20]],"date-time":"2019-03-20T11:04:23Z","timestamp":1553079863000},"page":"141-155","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Hygrothermal Behaviour Control in the Crawlspaces of Historical Museums"],"prefix":"10.1007","author":[{"given":"Jo\u00e3o M. P. Q.","family":"Delgado","sequence":"first","affiliation":[]},{"given":"Ana Sofia","family":"Guimar\u00e3es","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2019,3,21]]},"reference":[{"issue":"1","key":"10_CR1","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1007\/BF02486006","volume":"29","author":"A Bakolas","year":"1996","unstructured":"Bakolas A, Biscontin G, Moropoulou A, Zendri E (1996) Salt impact on brickwork along the canals of Venice. Mater Struct 29(1):47\u201355. https:\/\/doi.org\/10.1007\/BF02486006","journal-title":"Mater Struct"},{"issue":"6","key":"10_CR2","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1128\/AEM.1.6.287-293.1953","volume":"1","author":"SS Block","year":"1953","unstructured":"Block SS (1953) Humidity requirements for mould growth. Appl Microbiol 1(6):287\u2013293","journal-title":"Appl Microbiol"},{"key":"10_CR3","unstructured":"Bowley M (1975) Desalination of stone: a case study, Paper CP46\/75. Building Research Establishment, Watford, UK"},{"key":"10_CR4","unstructured":"Burke S (2005) Advantages and risks associated with crawl space foundations. In: Proceedings of the 7th symposium on building physics in the nordic countries, June 13\u201315, Reykjav\u00edk Iceland"},{"issue":"1","key":"10_CR5","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1108\/02630800710740976","volume":"25","author":"S Burke","year":"2007","unstructured":"Burke S (2007) Crawl spaces in wood framed single family dwellings in Sweden: unwanted yet popular. Struct Surv 25(1):51\u201360","journal-title":"Struct Surv"},{"issue":"4","key":"10_CR6","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1111\/j.1600-0668.2004.00237.x","volume":"14","author":"MJ Cunningham","year":"2004","unstructured":"Cunningham MJ, Roos C, Gu L, Spolek G (2004) Predicting psychrometric conditions in biocontaminant microenvironments with a microclimate heat and moisture transfer model\u00a0\u2013 description and field comparison. Indoor Air 14(4):235\u2013242","journal-title":"Indoor Air"},{"issue":"3","key":"10_CR7","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1615\/JPorMedia.v13.i3.30","volume":"13","author":"JMPQ Delgado","year":"2010","unstructured":"Delgado JMPQ, Ramos NMM, Barreira E, Freitas VP (2010) A critical review of hygrothermal models used in porous building materials. J Porous Media 13(3):221\u2013234","journal-title":"J Porous Media"},{"key":"10_CR8","unstructured":"Elmroth A (1975) Crawl space foundation. Construction Research, Report 12, Stockholm"},{"issue":"1","key":"10_CR9","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1046\/j.1600-0668.2003.00207.x","volume":"14","author":"G Emenius","year":"2004","unstructured":"Emenius G, Svartengren M, Korsgaard J, Nordvall L, Pershagen G, Wickman M (2004) Building characteristics, indoor air quality and recurrent wheezing in very young children (BAMSE). Indoor Air 14(1):34\u201342","journal-title":"Indoor Air"},{"issue":"1","key":"10_CR10","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1177\/1744259109355730","volume":"34","author":"A Evrard","year":"2010","unstructured":"Evrard A, De Herde A (2010) Hygrothermal performance of Lime-Hemp wall assemblies. J Build Phys 34(1):5\u201325","journal-title":"J Build Phys"},{"issue":"3","key":"10_CR11","doi-asserted-by":"publisher","first-page":"233","DOI":"10.2174\/187221211797636863","volume":"5","author":"VP Freitas","year":"2011","unstructured":"Freitas VP, Guimar\u00e3es AS, Delgado JMPQ (2011) The HUMIVENT device for rising damp treatment. Recent Patents Eng 5(3):233\u2013240","journal-title":"Recent Patents Eng"},{"key":"10_CR12","doi-asserted-by":"publisher","first-page":"311","DOI":"10.4028\/www.scientific.net\/DDF.353.311","volume":"353","author":"AS Guimar\u00e3es","year":"2014","unstructured":"Guimar\u00e3es AS, Delgado JMPQ, Freitas VP (2014) Rising damp: optimization of the wall base ventilation system. Defect Diffus Forum 353:311\u2013316","journal-title":"Defect Diffus Forum"},{"key":"10_CR13","doi-asserted-by":"crossref","unstructured":"Guimar\u00e3es AS, Delgado JMPQ, Freitas VP (2013) Rising damp in walls: evaluation of the level achieved by the damp front. J Build Phys in Press","DOI":"10.1177\/1744259112453822"},{"issue":"11","key":"10_CR14","doi-asserted-by":"publisher","first-page":"2414","DOI":"10.1016\/j.buildenv.2010.05.007","volume":"45","author":"AS Guimar\u00e3es","year":"2010","unstructured":"Guimar\u00e3es AS, Delgado JMPQ, Freitas VP (2010) Mathematical analysis of the evaporative process of a new technological treatment of rising damp in historic buildings. Build Environ 45(11):2414\u20132420","journal-title":"Build Environ"},{"key":"10_CR15","unstructured":"Hagentoft CE, Kalagasidis AS, Nilsson SF, Thorin M (2008) Mould growth control in cold attics through adaptive ventilation. In: Proceedings of the 8th Nordic symposium on building physics, Copenhagen, pp 1\u20138"},{"issue":"2","key":"10_CR16","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1177\/1420326X0101000204","volume":"10","author":"U Haverinen","year":"2001","unstructured":"Haverinen U, Husman T, Pekkanen J, Vahteristo M, Moschandreas D, Nevalainen A (2001a) Characteristics of moisture damage in houses and their association with self-reported symptoms of the occupants. Indoor Built Environ 10(2):83\u201394","journal-title":"Indoor Built Environ"},{"issue":"3","key":"10_CR17","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1034\/j.1600-0668.2001.011003192.x","volume":"11","author":"U Haverinen","year":"2001","unstructured":"Haverinen U, Husman T, Vahteristo M, Koskinen O, Moschandreas D, Nevalainen A, Juha P (2001b) Comparison of two-level and three-level classifications of moisture-damaged dwellings in relation to health effects. Indoor Air 11(3):192\u2013199","journal-title":"Indoor Air"},{"key":"10_CR18","unstructured":"Henningsson B (1980) Thermotolerant moulds on timber during kiln drying. Uppsala, Swedish University of Agricultural Sciences, Department of Forest Products, Note No 96"},{"key":"10_CR19","unstructured":"Hens H (1996) Final report task 1: modelling common exercises, Summary reports. Annex 24"},{"key":"10_CR20","volume-title":"The technology of building defects","author":"J Hinks","year":"1999","unstructured":"Hinks J, Cook G (1999) The technology of building defects. E & FN Spon, London"},{"key":"10_CR21","unstructured":"Holm AH, Kunzel HM (2003) Two-dimensional transient heat and moisture simulations of rising damp with WUFI-2D. In: Proceedings of the 2nd international conference on building physics, Leuven, Belgium, 14\u201318 September 2003, Swets & Zeitlinger B.V., Lisse, pp 363\u2013367"},{"issue":"2","key":"10_CR22","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1177\/1097196303032801","volume":"27","author":"A Iwamae","year":"2003","unstructured":"Iwamae A, Matsumoto M (2003) The humidity variation in crawl spaces of Japanese houses. J Therm Envel Build Sci 27(2):123\u2013133","journal-title":"J Therm Envel Build Sci"},{"key":"10_CR23","unstructured":"Iwamae A, Suzuki H (2008) Durability of crawl space based on damage due to wood rot. In: Proceedings of the 8th Nordic symposium on building physics, Copenhagen, pp 747\u2013754"},{"issue":"3","key":"10_CR24","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1016\/S0360-1323(00)00013-5","volume":"36","author":"J Kurnitski","year":"2001","unstructured":"Kurnitski J (2001) Ground moisture evaporation in crawl spaces. Build Environ 36(3):359\u2013373","journal-title":"Build Environ"},{"issue":"1","key":"10_CR25","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/S0378-7788(00)00061-X","volume":"33","author":"J Kurnitski","year":"2000","unstructured":"Kurnitski J, Matilainen M (2000) Moisture conditions of outdoor air-ventilated crawl spaces in apartment buildings in a cold climate. Energ Build 33(1):15\u201329","journal-title":"Energ Build"},{"key":"10_CR26","unstructured":"Matilainen M, Pasanen P (2002) Transport of fungal spores from crawl space to indoors. In: Indoor Air Monterey, USA"},{"issue":"2","key":"10_CR27","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1016\/S0378-7788(02)00051-8","volume":"35","author":"M Matilainen","year":"2003","unstructured":"Matilainen M, Kurnitski J, Sepp\u00e4nen O (2003) Moisture conditions and energy consumption in heated crawl spaces in cold climates. Energ Buildings 35(2):203\u2013216","journal-title":"Energ Buildings"},{"key":"10_CR28","unstructured":"Nofal M, Kumaran K (2000) On implementing experimental biological damage-functions models in durability assessment system. In: Proceedings of Japan-Canada housing R&D experts working group meeting building envelope, pp 111\u2013124"},{"issue":"1","key":"10_CR29","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1016\/S0007-1536(82)80212-X","volume":"79","author":"D Park","year":"1982","unstructured":"Park D (1982) Phylloplane fungi: tolerance of hyphal tips to drying. Trans Br Mycol Soc 79(1):174\u2013179","journal-title":"Trans Br Mycol Soc"},{"issue":"3","key":"10_CR30","first-page":"58","volume":"10","author":"I Samuelsson","year":"1994","unstructured":"Samuelsson I (1994) Moisture control in crawl space. ASHRAE Tech Data Bull 10(3):58\u201364","journal-title":"ASHRAE Tech Data Bull"},{"key":"10_CR31","unstructured":"Viitanen H (1996) Factors affecting the development of mould and brown rot decay in wooden material and wooden structures: Effect of humidity, temperature and exposure time. Dissertation, Uppsala"},{"key":"10_CR32","unstructured":"WIPO (2011) Hygro-adjustable wall base ventilation system for the treatment of rising damp. Publication n. WO\/2010\/093272, University of Porto. Webpage: https:\/\/patentscope.wipo.int\/search\/en\/detail.jsf?docId=WO2010093272 . Accessed in 6 of November 2017"}],"container-title":["Building Research: Design, Construction and Technologies","Museum Technology and Architecture"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-76172-5_10","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,12,2]],"date-time":"2020-12-02T03:08:31Z","timestamp":1606878511000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-319-76172-5_10"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019]]},"ISBN":["9783319761701","9783319761725"],"references-count":32,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-76172-5_10","relation":{},"ISSN":["2366-6307","2366-6315"],"issn-type":[{"type":"print","value":"2366-6307"},{"type":"electronic","value":"2366-6315"}],"subject":[],"published":{"date-parts":[[2019]]},"assertion":[{"value":"21 March 2019","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}}]}}