{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T10:38:51Z","timestamp":1761647931118},"publisher-location":"Berlin, Heidelberg","reference-count":12,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"type":"print","value":"9783642282546"},{"type":"electronic","value":"9783642282553"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2012]]},"DOI":"10.1007\/978-3-642-28255-3_31","type":"book-chapter","created":{"date-parts":[[2012,2,22]],"date-time":"2012-02-22T14:39:25Z","timestamp":1329921565000},"page":"283-290","source":"Crossref","is-referenced-by-count":1,"title":["Power Transformers Differential Protection Using the p-q Power Theory"],"prefix":"10.1007","author":[{"given":"Lu\u00eds M. R.","family":"Oliveira","sequence":"first","affiliation":[]},{"given":"Ant\u00f3nio J. Marques","family":"Cardoso","sequence":"additional","affiliation":[]}],"member":"297","reference":[{"key":"31_CR1","doi-asserted-by":"crossref","unstructured":"Girgis, R.S., teNyenhuis, E.G.: Characteristics of Inrush Current of Present Designs of Power Transformers. In: Power Engineering Society General Meeting (2007)","DOI":"10.1109\/PES.2007.386291"},{"key":"31_CR2","unstructured":"Kasztenny, B., Kulidjian, A.: An Improved Transformer Inrush Restraint Algorithm Increases Security While Maintaining Fault Response Performance. In: Proc. 53rd Annual Conf. for Protective Relay Engineers (2000)"},{"key":"31_CR3","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1109\/61.956726","volume":"16","author":"A. Guzm\u00e1n","year":"2001","unstructured":"Guzm\u00e1n, A., Zocholl, S., Benmouyal, G., Altuve, H.J.: A Current-Based Solution for Transformer Differential Protection - Part I: Problem Statement. IEEE Trans. Power Delivery\u00a016, 485\u2013491 (2001)","journal-title":"IEEE Trans. Power Delivery"},{"key":"31_CR4","unstructured":"Gaji\u0107, Z., Brn\u010di\u0107, I., Hillstr\u00f6m, B., Ivankovic, I.: Sensitive Turn-to-Turn Fault Protection for Power Transformers. In: CIGR\u00c9 Study Committee B5 Colloquium (2005)"},{"key":"31_CR5","doi-asserted-by":"publisher","first-page":"2473","DOI":"10.1109\/TPWRD.2005.855443","volume":"20","author":"G. Baoming","year":"2005","unstructured":"Baoming, G., Almeida, A.T., Qionglin, Z., Xiangheng, W.: An Equivalent Instantaneous Inductance-Based Technique for Discrimination Between Inrush Current and Internal Faults in Power Transformers. IEEE Trans. Power Delivery\u00a020, 2473\u20132482 (2005)","journal-title":"IEEE Trans. Power Delivery"},{"key":"31_CR6","unstructured":"Oliveira, L.M.R., Cardoso, A.J.M.: An EPVA-Based Strategy for Power Transformers Differential Protection. In: Proc. Advanced Research Workshop on Modern Transformers (2010)"},{"key":"31_CR7","doi-asserted-by":"publisher","first-page":"1109","DOI":"10.1109\/61.636909","volume":"12","author":"K. Yabe","year":"1997","unstructured":"Yabe, K.: Power Differential Method for Discrimination Between Fault and Magnetizing Inrush Current in Transformers. IEEE Trans. Power Delivery\u00a012, 1109\u20131118 (1997)","journal-title":"IEEE Trans. Power Delivery"},{"key":"31_CR8","doi-asserted-by":"publisher","first-page":"1203","DOI":"10.1080\/15325000590951618","volume":"33","author":"M. Tripathy","year":"2005","unstructured":"Tripathy, M., Maheshwari, R.P., Verma, H.K.: Advances in Transformer Protection: a Review. Electric Power Components and Systems\u00a033, 1203\u20131209 (2005)","journal-title":"Electric Power Components and Systems"},{"key":"31_CR9","doi-asserted-by":"publisher","first-page":"4606","DOI":"10.1109\/TIE.2009.2027922","volume":"56","author":"M. Drif","year":"2009","unstructured":"Drif, M., Cardoso, A.J.M.: The Use of the Instantaneous-Reactive-Power Signature Analysis for Rotor-Cage-Fault Diagnostics in Three-Phase Induction Motors. IEEE Trans. Industrial Electronics\u00a056, 4606\u20134614 (2009)","journal-title":"IEEE Trans. Industrial Electronics"},{"key":"31_CR10","doi-asserted-by":"publisher","first-page":"843","DOI":"10.1109\/TPWRD.2007.893591","volume":"22","author":"S. Lotfi-fard","year":"2007","unstructured":"Lotfi-fard, S., Faiz, J., Iravani, R.: Improved Overcurrent Protection Using Symmetrical Components. IEEE Trans. Power Delivery\u00a022, 843\u2013850 (2007)","journal-title":"IEEE Trans. Power Delivery"},{"key":"31_CR11","doi-asserted-by":"publisher","first-page":"1589","DOI":"10.1109\/TPWRD.2009.2039149","volume":"25","author":"L.M.R. Oliveira","year":"2010","unstructured":"Oliveira, L.M.R., Cardoso, A.J.M.: A Permeance-Based Transformer Model and its Application to Winding Interturn Arcing Fault Studies. IEEE Trans. Power Delivery\u00a025, 1589\u20131598 (2010)","journal-title":"IEEE Trans. Power Delivery"},{"key":"31_CR12","doi-asserted-by":"crossref","unstructured":"Oliveira, L.M.R., Cardoso, A.J.M.: Power Transformers Behavior Under the Occurrence of Inrush Currents and Turn-To-Turn Winding Insulation Faults. In: Proc. Int. Conf. Electrical Machines (2010)","DOI":"10.1109\/ICELMACH.2010.5608303"}],"container-title":["IFIP Advances in Information and Communication Technology","Technological Innovation for Value Creation"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-642-28255-3_31.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,3]],"date-time":"2021-05-03T12:12:48Z","timestamp":1620043968000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-642-28255-3_31"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012]]},"ISBN":["9783642282546","9783642282553"],"references-count":12,"URL":"https:\/\/doi.org\/10.1007\/978-3-642-28255-3_31","relation":{},"ISSN":["1868-4238","1861-2288"],"issn-type":[{"type":"print","value":"1868-4238"},{"type":"electronic","value":"1861-2288"}],"subject":[],"published":{"date-parts":[[2012]]}}}