{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T09:02:28Z","timestamp":1762506148684,"version":"3.40.3"},"publisher-location":"Berlin, Heidelberg","reference-count":31,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"type":"print","value":"9783642374685"},{"type":"electronic","value":"9783642374692"}],"license":[{"start":{"date-parts":[[2013,1,1]],"date-time":"2013-01-01T00:00:00Z","timestamp":1356998400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2013,1,1]],"date-time":"2013-01-01T00:00:00Z","timestamp":1356998400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2013]]},"DOI":"10.1007\/978-3-642-37469-2_4","type":"book-chapter","created":{"date-parts":[[2013,8,17]],"date-time":"2013-08-17T11:15:20Z","timestamp":1376738120000},"page":"91-117","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Infrared Thermography Application in Buildings Diagnosis: A Proposal for Test Procedures"],"prefix":"10.1007","author":[{"given":"E.","family":"Barreira","sequence":"first","affiliation":[]},{"given":"S. S.","family":"de Freitas","sequence":"additional","affiliation":[]},{"given":"V. P.","family":"de Freitas","sequence":"additional","affiliation":[]},{"given":"J. M. P. Q.","family":"Delgado","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2013,8,18]]},"reference":[{"key":"4_CR1","unstructured":"Rao, P.: Infrared thermography and its applications in civil engineering. The Indian Concrete Journal, 82(5), 41\u201350 (2008)"},{"key":"4_CR2","unstructured":"NEC San-ei Instruments, Ltd.: TH1 101 Thermo Tracer\u2014Operation Manual, Japan (1991)"},{"key":"4_CR3","volume-title":"A Practical Guide to Infra-red Thermography for Building Surveys","author":"JM Hart","year":"1991","unstructured":"Hart, J.M.: A Practical Guide to Infra-red Thermography for Building Surveys. Garston, Watford (1991)"},{"issue":"1","key":"4_CR4","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/j.culher.2003.07.002","volume":"5","author":"N.P. Avdelidis","year":"2004","unstructured":"Avdelidis, N.P., Moropoulou, A.: Applications of infrared thermography for the investigation of historic structures. J. Cultural Heritage. 5(1), 119\u2013127 (2004)","journal-title":"J. Cultural Heritage."},{"issue":"1","key":"4_CR5","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0378-7788(97)00039-X","volume":"29","author":"E. Grinzato","year":"1998","unstructured":"Grinzato, E., Vavilovb, V., Kauppinen, T.: Quantitative infrared thermography in buildings. Energ. Build., 29(1), 1\u20139 (1998)","journal-title":"Energ. Build."},{"issue":"1\u20132","key":"4_CR6","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/S0196-8904(96)00176-8","volume":"39","author":"D.A. Haralambopoulos","year":"1998","unstructured":"Haralambopoulos, D.A., Paparsenos, G.F.: Assessing the thermal insulation of old buildings\u2014The need for in situ spot measurements of thermal resistance and planar infrared thermography. Energy Convers. Manage., 39(1\u20132), 65\u201379 (1998)","journal-title":"Energy Convers. Manage."},{"key":"4_CR7","unstructured":"Incropera, F.P., Witt, D.P.: Fundamentals of Heat and Mass Transfer- 4th ed. John Wiley & Sons ed. , New York  (1996)"},{"key":"4_CR8","volume-title":"Introduction to Building Physics","author":"C Hagentoft","year":"2001","unstructured":"Hagentoft, C.: Introduction to Building Physics. Student Litteratur, Sweden (2001)"},{"key":"4_CR9","unstructured":"Chown, G.A., Burn, K. N.: Thermographic identification of buildings enclosure defects and deficiencies. Canadian building digest 229, Canada, NRC\u2013IRC (1983)"},{"issue":"2","key":"4_CR10","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1108\/02630809810219669","volume":"16","author":"M.Y.L. Chew","year":"1998","unstructured":"Chew, M.Y.L.: Assessing building facades using infra-red thermography. Struct. Survey, 16(2), 81\u201386 (1998)","journal-title":"Struct. Survey"},{"key":"4_CR11","unstructured":"Gaussorgues, G.: La thermographie infrarouge\u2014Principles, Technologies, Applications. 4th edn. TEC & DOC, Paris, France (1999)"},{"key":"4_CR12","unstructured":"Barreira, E.: Thermography applications in the study of buildings hygrothermal behaviour. M.Sc. Thesis, Porto, FEUP, Portugal (in Portuguese) (2004)"},{"key":"4_CR13","unstructured":"Barreira, E., de Freitas, V.P.: Thermal images obtained from different solutions of radiant floor. Internal Report LFC\/IC 134.2003, LFC, FEUP, Porto, Portugal (in Portuguese) (2003)"},{"key":"4_CR14","doi-asserted-by":"crossref","unstructured":"Barreira, E., de Freitas, V.P., Delgado, J.M.P.Q., Ramos, N.: Thermography applications in the study of buildings hygrothermal behaviour. Chapter published in infrared thermography. In: Prakash, R.V. (ed.) Intech, Croatia (2012)","DOI":"10.5772\/28282"},{"issue":"1","key":"4_CR15","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1016\/j.conbuildmat.2005.06.049","volume":"21","author":"E. Barreira","year":"2007","unstructured":"Barreira, E., de Freitas, V.P.: Evaluation of building materials using infrared thermography. Constr. Build. Mater., 21(1), 218\u2013224 (2007)","journal-title":"Constr. Build. Mater."},{"issue":"8","key":"4_CR16","first-page":"30","volume":"3","author":"E Barreira","year":"2004","unstructured":"Barreira, E., de Freitas, V.P.: Thermal comfort evaluation of floor coatings using infrared thermography. Construlink Int. J. 3(8), 30\u201338 (2004). (in Portuguese)","journal-title":"Construlink Int. J."},{"key":"4_CR17","doi-asserted-by":"crossref","unstructured":"Sakagami, T., Komiyama, T., Suzuki, H.: Proposal for a new thermographic non-destructive testing technique using microwave heating, In: Proceedings of the thermosense XXI, International society for optical engineering (SPIE), Orlando, pp. 99\u2013103 (1999)","DOI":"10.1117\/12.342324"},{"key":"4_CR18","doi-asserted-by":"crossref","unstructured":"Cerdeira, F., V\u00e1zquez, M.E., Collazo, J., Granada, E. Applicability of infrared thermography to the study of the behaviour of stone panels as building envelopes. Energ. Build., 43(8), 1845\u2013185 (2011)","DOI":"10.1016\/j.enbuild.2011.03.029"},{"key":"4_CR19","doi-asserted-by":"crossref","unstructured":"Sim\u00f5es, N., Sim\u00f5es, I., Tadeu, A., Serra, C.: Evaluation of adhesive bonding of ceramic tiles using active thermography. In: Proceedings of the 11th international conference on quantitative infrared thermography, Naples, Italy (2012)","DOI":"10.21611\/qirt.2012.362"},{"key":"4_CR20","doi-asserted-by":"crossref","unstructured":"Rosina, E., Ludwig, N.: Optimal thermographic procedures for moisture analysis in building materials. In: Proceedings of society of photographic instrumentation engineers (SPIE), 3827, pp. 22\u201333 (1999)","DOI":"10.1117\/12.361015"},{"key":"4_CR21","unstructured":"ASTM.: ASTM C1153\u201410 Standard practices for location of wet insulation in roofing systems using infrared imaging. American Society for Testing and Materials (ASTM) International (2010)"},{"issue":"2","key":"4_CR22","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1016\/S0378-7788(01)00105-0","volume":"34","author":"CA Balaras","year":"2002","unstructured":"Balaras, C.A., Argiriou, A.A.: Infrared thermography for building diagnostics. Energ. Build. 34(2), 171\u2013183 (2002)","journal-title":"Energ. Build."},{"issue":"3","key":"4_CR23","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1016\/S1350-4495(02)00212-8","volume":"44","author":"N.P. Avdelidis","year":"2003","unstructured":"Avdelidis, N.P., Moropoulou, A., Theoulakis, P.: Detection of water deposits and movement in porous materials by infrared imaging. Infrared Phys. Technol. 44(3), 183\u2013190 (2003)","journal-title":"Infrared Phys. Technol."},{"issue":"18","key":"4_CR24","doi-asserted-by":"crossref","first-page":"1770","DOI":"10.1080\/09500341003731597","volume":"57","author":"B. Grinzato","year":"2010","unstructured":"Grinzato, B., Cadelano, G., Bison, P.: Moisture map by IR thermography. J. Modern Optics, 57(18), 1770\u20131778 (2010)","journal-title":"J. Modern Optics"},{"issue":"5","key":"4_CR25","doi-asserted-by":"crossref","first-page":"2190","DOI":"10.1016\/j.conbuildmat.2010.10.007","volume":"25","author":"J.L. Lerma","year":"2011","unstructured":"Lerma, J.L., Cabrelles, M., Portal\u00e9s, C.: Multitemporal thermal analysis to detect moisture on a building fa\u00e7ade. Construction and Building Materials, 25(5), 2190\u20132197 (2011)","journal-title":"Construction and Building Materials"},{"key":"4_CR26","unstructured":"Rajewski, G., Devine, G.: Building Envelope\u2014infrared thermography, preventative roof maintenance workshop, Building operator association (1996)"},{"key":"4_CR27","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1016\/j.apenergy.2011.12.054","volume":"97","author":"F Asdrubali","year":"2012","unstructured":"Asdrubali, F., Baldinelli, G., Bianchi, F.: A quantitative methodology to evaluate thermal bridges in buildings. Appl. Energy 97, 365\u2013373 (2012)","journal-title":"Appl. Energy"},{"issue":"6","key":"4_CR28","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1016\/j.enbuild.2003.12.012","volume":"36","author":"S.M. Oca\u00f1a","year":"2004","unstructured":"Oca\u00f1a, S.M.; Guerrero, I.C.; Requena, I.G. (2004). Thermographic survey of two rural buildings in Spain. Energy and Buildings, 36(6), 515\u2013523","journal-title":"Energy and Buildings"},{"key":"4_CR29","unstructured":"de Freitas, S.S., de Freitas, V.P., Barreira, E.: Application of infrared thermography to the diagnosis of fa\u00e7ade rendering detachment, A state of the art report on building pathology\u2014CIB W086, CIB Edition (in Press) (2013)"},{"key":"4_CR30","unstructured":"Barreira, E., de Freitas, V.P.: Infrared thermography applications in the study of building hygrothermal behaviour. CIB W40 Meeting, Caledonian University, Glasgow (2004a)"},{"key":"4_CR31","unstructured":"Barreira, E., de Freitas, V.P.: Importance of thermography in the study of ETICS finishing coatings degradation due to algae and mildew growth. In: Proceedings of the 10th international conference on durability of building materials and components (10DBMC), CSTB, Lyon (2005)"}],"container-title":["Advanced Structured Materials","Industrial and Technological Applications of Transport in Porous Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-642-37469-2_4","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,2,19]],"date-time":"2023-02-19T14:46:16Z","timestamp":1676817976000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-642-37469-2_4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013]]},"ISBN":["9783642374685","9783642374692"],"references-count":31,"URL":"https:\/\/doi.org\/10.1007\/978-3-642-37469-2_4","relation":{},"ISSN":["1869-8433","1869-8441"],"issn-type":[{"type":"print","value":"1869-8433"},{"type":"electronic","value":"1869-8441"}],"subject":[],"published":{"date-parts":[[2013]]},"assertion":[{"value":"18 August 2013","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}}]}}