{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,9]],"date-time":"2024-09-09T16:08:09Z","timestamp":1725898089333},"publisher-location":"Berlin, Heidelberg","reference-count":16,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"type":"print","value":"9783642382550"},{"type":"electronic","value":"9783642382567"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2013]]},"DOI":"10.1007\/978-3-642-38256-7_9","type":"book-chapter","created":{"date-parts":[[2013,5,14]],"date-time":"2013-05-14T03:22:23Z","timestamp":1368501743000},"page":"135-149","source":"Crossref","is-referenced-by-count":0,"title":["Laser Doppler Flowmeters Prototypes: Monte Carlo Simulations Validation Paired with Measurements"],"prefix":"10.1007","author":[{"given":"Edite","family":"Figueiras","sequence":"first","affiliation":[]},{"given":"Anne","family":"Humeau-Heurtier","sequence":"additional","affiliation":[]},{"given":"Rita","family":"Campos","sequence":"additional","affiliation":[]},{"given":"Ricardo","family":"Oliveira","sequence":"additional","affiliation":[]},{"given":"Lu\u00eds F. Requicha","family":"Ferreira","sequence":"additional","affiliation":[]},{"given":"Frits","family":"de Mul","sequence":"additional","affiliation":[]}],"member":"297","reference":[{"key":"9_CR1","doi-asserted-by":"publisher","first-page":"2097","DOI":"10.1364\/AO.20.002097","volume":"20","author":"R.F. Bonner","year":"1981","unstructured":"Bonner, R.F., Nossal, R.: Model for laser Doppler measurements of blood flow in tissue. Applied Optics\u00a020, 2097\u20132107 (1981)","journal-title":"Applied Optics"},{"key":"9_CR2","volume-title":"Biomedical Photonics Handbook, ch. 15","author":"G.E. Nilsson","year":"2003","unstructured":"Nilsson, G.E., Salerud, E.G., Stromberg, T.N.O., Wardell, K.: Laser Doppler perfusion monitoring and imaging. In: Vo-Dinh, T. (ed.) Biomedical Photonics Handbook, ch. 15. CRC Press, Washington, D.C (2003)"},{"key":"9_CR3","doi-asserted-by":"crossref","unstructured":"Oliveira, R., Semedo, S., Figueiras, E., Requicha Ferreira, L.F., Humeau, A.: Laser Doppler Flowmeters for microcirculation measurements. In: 1st Portuguese Meeting in Bioengineering - Bioengineering and Medical Sciences - The Challenge of the XXI Century, Portuguese chapter of IEEE EMBS; Technical University of Portugal (2011)","DOI":"10.1109\/ENBENG.2011.6026037"},{"key":"9_CR4","volume-title":"Numerical Simulations - Applications, Examples and Theory, ch. 7","author":"E. Figueiras","year":"2011","unstructured":"Figueiras, E., Ferreira, L.F.R., De Mul, F.F.M., Humeau, A.: Monte Carlo Methods to Numerically Simulate Signals Reflecting the Microvascular Perfusion. In: Angermann, L. (ed.) Numerical Simulations - Applications, Examples and Theory, ch. 7. InTech, Rijeka (2011)"},{"key":"9_CR5","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1046\/j.1087-0024.2000.00010.x","volume":"5","author":"I.M. Braverman","year":"2000","unstructured":"Braverman, I.M.: The Cutaneous Microcirculation. J. Investig. Dermatol. Symp. Proc.\u00a05, 3\u20139 (2000)","journal-title":"J. Investig. Dermatol. Symp. Proc."},{"key":"9_CR6","unstructured":"Figueiras, E., Ferreira, L.F.R., Humeau, A.: Phantom validation for depth assessment in laser Doppler flowmetry technique. In: Proceedings of EOS, Topical Meeting on Diffractive Optics, 2413, Koli (Finland) (2010)"},{"key":"9_CR7","first-page":"39","volume":"18","author":"M.D. Waterworth","year":"1995","unstructured":"Waterworth, M.D., Tarte, B.J., Joblin, A.J., van Doorn, T., Niesler, H.E.: Optical transmission properties of homogenized milk used as a phantom material in visible wavelength imaging. Australasian Physical and Engineering Sciences in Medicine\u00a018, 39\u201344 (1995)","journal-title":"Australasian Physical and Engineering Sciences in Medicine"},{"issue":"5","key":"9_CR8","doi-asserted-by":"crossref","first-page":"054064","DOI":"10.1117\/1.2992485","volume":"13","author":"Q. Li","year":"2008","unstructured":"Li, Q., Lee, B.J., Zhang, Z.M., Allen, D.W.: Light scattering of semitransparent sintered polytetrafluoroethylene films. Journal of Biomedical Optics 13(5), 054064 (2008)","journal-title":"Journal of Biomedical Optics"},{"key":"9_CR9","doi-asserted-by":"crossref","first-page":"014015","DOI":"10.1117\/1.2854691","volume":"13","author":"I. Fredriksson","year":"2008","unstructured":"Fredriksson, I., Larsson, M., Str\u00f6mberg, T.: Optical microcirculatory skin model: assessed by Monte Carlo simulations paired with in vivo laser Doppler flowmetry. Journal of Biomedical Optics 13, 014015 (2008)","journal-title":"Journal of Biomedical Optics"},{"key":"9_CR10","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1016\/j.mvr.2009.02.008","volume":"78","author":"I. Fredriksson","year":"2009","unstructured":"Fredriksson, I., Larsson, M., Str\u00f6mberg, T.: Measurement depth and volume in laser Doppler flowmetry. Microvascular Research\u00a078, 4\u201313 (2009)","journal-title":"Microvascular Research"},{"key":"9_CR11","doi-asserted-by":"publisher","first-page":"2465","DOI":"10.1088\/0031-9155\/43\/9\/003","volume":"43","author":"C.R. Simpson","year":"1998","unstructured":"Simpson, C.R., Kohl, M., Essenpreis, M., Cope, M.: Near infrared optical properties of ex-vivo human skin and subcutaneous tissues measured using the Monte Carlo inversion technique. Phys. Med. Biol.\u00a043, 2465\u20132478 (1998)","journal-title":"Phys. Med. Biol."},{"key":"9_CR12","unstructured":"Prahl, S.: Optical Absorption of Hemoglobin (1999), \n                    \n                      http:\/\/omlc.ogi.edu\/spectra\/hemoglobin\/"},{"issue":"10","key":"9_CR13","first-page":"1861","volume":"17","author":"L.M. Hamberg","year":"1996","unstructured":"Hamberg, L.M., Hunter, G.J., Kierstead, D., Lo, E.H., Gonzalez, R.G., Wolf, G.I.: Measurement of cerebral blood volume with substraction three-dimentional functional CT. Am. J. Neuroradiol.\u00a017(10), 1861\u20131869 (1996)","journal-title":"Am. J. Neuroradiol."},{"key":"9_CR14","doi-asserted-by":"publisher","first-page":"6595","DOI":"10.1364\/AO.34.006595","volume":"34","author":"F.F.M. Mul De","year":"1995","unstructured":"De Mul, F.F.M., Koelink, M.H., Kok, M.L., Harmsma, P.J., Greve, J., Graaff, R., Aarnoudse, J.G.: Laser Doppler Velocimetry and Monte Carlo Simulations on Models for Blood Perfusion in Tissue. Applied Optics\u00a034, 6595\u20136611 (1995)","journal-title":"Applied Optics"},{"key":"9_CR15","volume-title":"Handbook of Coherent Domain Optical Methods, Biomedical Diagnostics. Environment and Material Science, ch. 12","author":"F.F.M. Mul De","year":"2004","unstructured":"De Mul, F.F.M.: Monte-Carlo simulation of Light transport in Turbid Media. In: Tuchin, V.V. (ed.) Handbook of Coherent Domain Optical Methods, Biomedical Diagnostics. Environment and Material Science, ch. 12. Kluwer Publishers, Dordrecht (2004)"},{"key":"9_CR16","doi-asserted-by":"publisher","first-page":"33563","DOI":"10.1109\/TIM.2007.909473","volume":"57","author":"S.K. Ozdemir","year":"2008","unstructured":"Ozdemir, S.K., Ohno, I., Shinohara, S.: A comparative Study for the Assesment on Blood Flow Measurement Using Self-Mixing Laser Speckle Interferometer. IEEE Transactions on Instrumentation and Measurement\u00a057, 33563 (2008)","journal-title":"IEEE Transactions on Instrumentation and Measurement"}],"container-title":["Communications in Computer and Information Science","Biomedical Engineering Systems and Technologies"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-642-38256-7_9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,12]],"date-time":"2019-05-12T21:18:57Z","timestamp":1557695937000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-642-38256-7_9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013]]},"ISBN":["9783642382550","9783642382567"],"references-count":16,"URL":"https:\/\/doi.org\/10.1007\/978-3-642-38256-7_9","relation":{},"ISSN":["1865-0929","1865-0937"],"issn-type":[{"type":"print","value":"1865-0929"},{"type":"electronic","value":"1865-0937"}],"subject":[],"published":{"date-parts":[[2013]]}}}