{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T17:24:00Z","timestamp":1743009840010,"version":"3.40.3"},"publisher-location":"Singapore","reference-count":80,"publisher":"Springer Nature Singapore","isbn-type":[{"type":"print","value":"9789819721108"},{"type":"electronic","value":"9789819719204"}],"license":[{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024]]},"DOI":"10.1007\/978-981-97-1920-4_9","type":"book-chapter","created":{"date-parts":[[2024,10,11]],"date-time":"2024-10-11T19:01:58Z","timestamp":1728673318000},"page":"79-92","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Recent Development of Transcatheter Aortic Valve Implantation (TAVI): Reality in Malaysia"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6606-4582","authenticated-orcid":false,"given":"Adi Azriff","family":"Basri","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9072-9476","authenticated-orcid":false,"given":"Ernnie Illyani","family":"Basri","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5790-5009","authenticated-orcid":false,"given":"Mohamed","family":"Zuber","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1460-5687","authenticated-orcid":false,"given":"Ahmad Fazli Abdul","family":"Aziz","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5364-7452","authenticated-orcid":false,"given":"Muhammad Shukri","family":"Zakaria","sequence":"additional","affiliation":[]},{"given":"Rosli M.","family":"Ali","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5938-346X","authenticated-orcid":false,"given":"Masaaki","family":"Tamagawa","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4065-4266","authenticated-orcid":false,"given":"Kamarul Arifin","family":"Ahmad","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2024,10,12]]},"reference":[{"issue":"12","key":"9_CR1","doi-asserted-by":"publisher","first-page":"1347","DOI":"10.1080\/10255842.2012.746676","volume":"17","author":"F Auricchio","year":"2013","unstructured":"Auricchio F, Conti M, Morganti S, Reali A (2013) Simulation of transcatheter aortic valve implantation: a patient-specific finite element approach. Comput Methods Biomech Biomed Eng 17(12):1347\u20131357. https:\/\/doi.org\/10.1080\/10255842.2012.746676","journal-title":"Comput Methods Biomech Biomed Eng"},{"issue":"6","key":"9_CR2","doi-asserted-by":"publisher","first-page":"1857","DOI":"10.1016\/j.athoracsur.2009.08.025","volume":"88","author":"AN Azadani","year":"2009","unstructured":"Azadani AN et al (2009) Energy loss due to paravalvular leak with transcatheter aortic valve implantation. Ann Thorac Surg 88(6):1857\u20131863. https:\/\/doi.org\/10.1016\/j.athoracsur.2009.08.025","journal-title":"Ann Thorac Surg"},{"issue":"6","key":"9_CR3","doi-asserted-by":"publisher","first-page":"1864","DOI":"10.1016\/j.athoracsur.2009.08.004","volume":"88","author":"AN Azadani","year":"2009","unstructured":"Azadani AN et al (2009) Valve-in-valve implantation using a novel supravalvular transcatheter aortic valve: proof of concept. Ann Thorac Surg 88(6):1864\u20131869. https:\/\/doi.org\/10.1016\/j.athoracsur.2009.08.004","journal-title":"Ann Thorac Surg"},{"key":"9_CR4","doi-asserted-by":"publisher","unstructured":"Azadani AN, Jaussaud N, Matthews PB, Ge L, Chuter TAM, Tseng EE (2010) Transcatheter aortic valves inadequately relieve stenosis in small degenerated bioprostheses. Interact Cardiovasc Thorac Surg 11(1):70\u201377. https:\/\/doi.org\/10.1510\/icvts.2009.225144","DOI":"10.1510\/icvts.2009.225144"},{"key":"9_CR5","doi-asserted-by":"publisher","unstructured":"Azadani AN, Jaussaud N, Ge L, Chitsaz S, Chuter TAM, Tseng EE (2011) Valve-in-valve hemodynamics of 20-mm transcatheter aortic valves in small bioprostheses. Ann Thorac Surg 92(2):548\u2013555. https:\/\/doi.org\/10.1016\/j.athoracsur.2011.04.009","DOI":"10.1016\/j.athoracsur.2011.04.009"},{"key":"9_CR6","doi-asserted-by":"publisher","DOI":"10.1155\/2020\/9163085","author":"AA Basri","year":"2020","unstructured":"Basri AA et al (2020) Fluid structure interaction on paravalvular leakage of transcatheter aortic valve implantation related to aortic stenosis: a patient-specific case. Comput Math Methods Med. https:\/\/doi.org\/10.1155\/2020\/9163085","journal-title":"Comput Math Methods Med"},{"key":"9_CR7","unstructured":"Basri AA, Zubair M, Aziz AFA, Ali RM, Tamagawa M, Ahmad KA (2014) The effect of aortic stenosis on the hemodynamic flow properties using computational fluid dynamics. In: Proceedings of international conference on computational methods in engineering and health sciences (ICCMEH), December 17\u201319, Manipal, India, pp 17\u201320"},{"key":"9_CR8","doi-asserted-by":"publisher","unstructured":"Basri AA et al (2016) The hemodynamic effects of paravalvular leakage using fluid structure interaction; transcatheter aortic valve implantation patient. J Med Image Health Inform 6(6):1513\u20131518. https:\/\/doi.org\/10.1166\/jmihi.2016.1840","DOI":"10.1166\/jmihi.2016.1840"},{"key":"9_CR9","doi-asserted-by":"publisher","unstructured":"Basri AA et al (2021) Fluid-structure interaction in problems of patient specific transcatheter aortic valve implantation with and without Paravalvular leakage complication. https:\/\/doi.org\/10.32604\/fdmp.2021.010925","DOI":"10.32604\/fdmp.2021.010925"},{"key":"9_CR10","doi-asserted-by":"publisher","unstructured":"Bianchi M et al (2019) Patient-specific simulation of transcatheter aortic valve replacement: impact of deployment options on Paravalvular leakage. 18(2):435\u2013451. https:\/\/doi.org\/10.4172\/2157-7633.1000305.Improved","DOI":"10.4172\/2157-7633.1000305.Improved"},{"key":"9_CR11","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1007\/978-3-642-76846-0_4","volume":"86","author":"MM Black","year":"1994","unstructured":"Black MM, Drury PJ (1994) Mechanical and Other Problems of Artificial Valves. Pathol Dev 86:127\u2013159","journal-title":"Pathol Dev"},{"issue":"1","key":"9_CR12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-020-66899-6","volume":"10","author":"GM Bosi","year":"2020","unstructured":"Bosi GM et al (2020) A validated computational framework to predict outcomes in TAVI. Sci Rep 10(1):1\u201311. https:\/\/doi.org\/10.1038\/s41598-020-66899-6","journal-title":"Sci Rep"},{"issue":"1","key":"9_CR13","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/j.ijcard.2013.03.065","volume":"168","author":"CV Bourantas","year":"2013","unstructured":"Bourantas CV et al (2013) Future perspectives in transcatheter aortic valve implantation. Int J Cardiol 168(1):11\u201318. https:\/\/doi.org\/10.1016\/j.ijcard.2013.03.065","journal-title":"Int J Cardiol"},{"key":"9_CR14","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1016\/j.ijcard.2015.11.106","volume":"203","author":"G Burriesci","year":"2016","unstructured":"Burriesci G, Peruzzo P, Susin FM, Tarantini G, Colli A (2016) In vitro hemodynamic testing of Amplatzer plugs for paravalvular leak occlusion after transcatheter aortic valve implantation. Int J Cardiol 203:1093\u20131099. https:\/\/doi.org\/10.1016\/j.ijcard.2015.11.106","journal-title":"Int J Cardiol"},{"issue":"2","key":"9_CR15","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1007\/s11517-012-0864-1","volume":"50","author":"C Capelli","year":"2012","unstructured":"Capelli C et al (2012) Patient-specific simulations of transcatheter aortic valve stent implantation. Med Biol Eng Comput 50(2):183\u2013192. https:\/\/doi.org\/10.1007\/s11517-012-0864-1","journal-title":"Med Biol Eng Comput"},{"issue":"9667","key":"9_CR16","doi-asserted-by":"publisher","first-page":"956","DOI":"10.1093\/ejechocard\/jen240","volume":"373","author":"B Carabello","year":"2009","unstructured":"Carabello B, Paulus W (2009) Aortic stenosis. Lancet 373(9667):956\u2013966. https:\/\/doi.org\/10.1093\/ejechocard\/jen240","journal-title":"Lancet"},{"key":"9_CR17","doi-asserted-by":"crossref","unstructured":"Carrel T, Englberger L, Stalder M (2013) Replacement: the concept of sutureless valve technology 21","DOI":"10.13055\/ojcar_4_1_1.130112"},{"issue":"7","key":"9_CR18","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.1007\/s10237-012-0375-x","volume":"11","author":"S Chandra","year":"2012","unstructured":"Chandra S, Rajamannan NM, Sucosky P (2012) Computational assessment of bicuspid aortic valve wall-shear stress: Implications for calcific aortic valve disease. Biomech Model Mechanobiol 11(7):1085\u20131096. https:\/\/doi.org\/10.1007\/s10237-012-0375-x","journal-title":"Biomech Model Mechanobiol"},{"issue":"4","key":"9_CR19","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1016\/j.jcin.2008.03.018","volume":"1","author":"PTL Chiam","year":"2008","unstructured":"Chiam PTL, Ruiz CE (2008) Percutaneous transcatheter aortic valve implantation: assessing results, judging outcomes, and planning trials. The interventionalist perspective. JACC Cardiovasc Interv 1(4):341\u2013350. https:\/\/doi.org\/10.1016\/j.jcin.2008.03.018","journal-title":"JACC Cardiovasc Interv"},{"issue":"2","key":"9_CR20","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1016\/j.ahj.2008.10.003","volume":"157","author":"PTL Chiam","year":"2009","unstructured":"Chiam PTL, Ruiz CE (2009) Percutaneous transcatheter aortic valve implantation: evolution of the technology. Am Heart J 157(2):229\u2013242. https:\/\/doi.org\/10.1016\/j.ahj.2008.10.003","journal-title":"Am Heart J"},{"issue":"3","key":"9_CR21","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1111\/jocs.12093","volume":"28","author":"W-C Cho","year":"2013","unstructured":"Cho W-C et al (2013) Mechanical valve replacement versus bioprosthetic valve replacement in the tricuspid valve position. J Card Surg 28(3):212\u2013217. https:\/\/doi.org\/10.1111\/jocs.12093","journal-title":"J Card Surg"},{"issue":"3","key":"9_CR22","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1016\/j.acvd.2012.01.005","volume":"105","author":"A Cribier","year":"2012","unstructured":"Cribier A (2012) Development of transcatheter aortic valve implantation (TAVI): a 20-year odyssey. Arch Cardiovasc Dis 105(3):146\u2013152. https:\/\/doi.org\/10.1016\/j.acvd.2012.01.005","journal-title":"Arch Cardiovasc Dis"},{"issue":"24","key":"9_CR23","doi-asserted-by":"publisher","first-page":"3006","DOI":"10.1161\/01.CIR.0000047200.36165.B8","volume":"106","author":"A Cribier","year":"2002","unstructured":"Cribier A et al (2002) Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation 106(24):3006\u20133008. https:\/\/doi.org\/10.1161\/01.CIR.0000047200.36165.B8","journal-title":"Circulation"},{"issue":"6","key":"9_CR24","doi-asserted-by":"publisher","first-page":"1214","DOI":"10.1016\/j.jacc.2006.01.049","volume":"47","author":"A Cribier","year":"2006","unstructured":"Cribier A et al (2006) Treatment of calcific aortic stenosis with the percutaneous heart valve: mid-term follow-up from the initial feasibility studies: the French experience. J Am Coll Cardiol 47(6):1214\u20131223. https:\/\/doi.org\/10.1016\/j.jacc.2006.01.049","journal-title":"J Am Coll Cardiol"},{"key":"9_CR25","doi-asserted-by":"publisher","unstructured":"Cribier A, Eltchaninoff H (2013) Transcatheter Aortic Valve Implantation (TAVI) with the Edwards Sapien XT device. In: Catheter-based cardiovascular interventions: a knowledge-based approach, pp 721\u2013744. https:\/\/doi.org\/10.1007\/978-3-642-27676-7","DOI":"10.1007\/978-3-642-27676-7"},{"issue":"5","key":"9_CR26","doi-asserted-by":"publisher","first-page":"1227","DOI":"10.1016\/j.jtcvs.2009.02.057","volume":"138","author":"HA Dwyer","year":"2009","unstructured":"Dwyer HA, Matthews PB, Azadani A, Ge L, Guy TS, Tseng EE (2009a) Migration forces of transcatheter aortic valves in patients with noncalcific aortic insufficiency. J Thorac Cardiovasc Surg 138(5):1227\u20131233. https:\/\/doi.org\/10.1016\/j.jtcvs.2009.02.057","journal-title":"J Thorac Cardiovasc Surg"},{"key":"9_CR27","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1510\/icvts.2008.200006","volume":"9","author":"HA Dwyer","year":"2009","unstructured":"Dwyer HA et al (2009b) Article in press computational fluid dynamics simulation of transcatheter aortic valve degeneration. Interact Cardiovasc Thorac Surg 9:301\u2013308. https:\/\/doi.org\/10.1510\/icvts.2008.200006","journal-title":"Interact Cardiovasc Thorac Surg"},{"issue":"7","key":"9_CR28","doi-asserted-by":"publisher","first-page":"608","DOI":"10.1055\/s-0039-1695779","volume":"68","author":"K Eghbalzadeh","year":"2020","unstructured":"Eghbalzadeh K et al (2020) SAVR versus TAVI: what about the Hemodynamic Performance? An in vivo and in vitro analysis. Thorac Cardiovasc Surg 68(7):608\u2013615. https:\/\/doi.org\/10.1055\/s-0039-1695779","journal-title":"Thorac Cardiovasc Surg"},{"issue":"3","key":"9_CR29","doi-asserted-by":"publisher","first-page":"1822","DOI":"10.1016\/j.ijcard.2013.07.117","volume":"168","author":"JP Fanning","year":"2013","unstructured":"Fanning JP, Platts DG, Walters DL, Fraser JF (2013) Transcatheter aortic valve implantation (TAVI): valve design and evolution. Int J Cardiol 168(3):1822\u20131831. https:\/\/doi.org\/10.1016\/j.ijcard.2013.07.117","journal-title":"Int J Cardiol"},{"issue":"1","key":"9_CR30","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1007\/s11748-013-0262-0","volume":"62","author":"H Furukawa","year":"2014","unstructured":"Furukawa H, Tanemoto K (2014) Current status and future perspectives of prosthetic valve selection for aortic valve replacement. Gen Thorac Cardiovasc Surg 62(1):19\u201323. https:\/\/doi.org\/10.1007\/s11748-013-0262-0","journal-title":"Gen Thorac Cardiovasc Surg"},{"issue":"7","key":"9_CR31","doi-asserted-by":"publisher","first-page":"765","DOI":"10.1161\/01.CIR.101.7.765","volume":"101","author":"D Garcia","year":"2000","unstructured":"Garcia D, Pibarot P, Dumesnil JG, Sakr F, Durand LG (2000) Assessment of aortic valve stenosis severity: a new index based on the energy loss concept. Circulation 101(7):765\u2013771. https:\/\/doi.org\/10.1161\/01.CIR.101.7.765","journal-title":"Circulation"},{"issue":"1","key":"9_CR32","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/j.jacc.2007.04.047","volume":"50","author":"E Grube","year":"2007","unstructured":"Grube E et al (2007) Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding corevalve prosthesis. device success and 30-day clinical outcome. J Am Coll Cardiol 50(1):69\u201376. https:\/\/doi.org\/10.1016\/j.jacc.2007.04.047","journal-title":"J Am Coll Cardiol"},{"issue":"10","key":"9_CR33","doi-asserted-by":"publisher","first-page":"E282","DOI":"10.1111\/aor.13504","volume":"43","author":"U G\u00fclan","year":"2019","unstructured":"G\u00fclan U et al (2019) Performance analysis of the transcatheter aortic valve implantation on blood flow hemodynamics: An optical imaging-based in vitro study. Artif Organs 43(10):E282\u2013E293. https:\/\/doi.org\/10.1111\/aor.13504","journal-title":"Artif Organs"},{"issue":"6","key":"9_CR34","doi-asserted-by":"publisher","first-page":"1195","DOI":"10.1007\/s10439-014-1008-6","volume":"42","author":"PS Gunning","year":"2014","unstructured":"Gunning PS, Saikrishnan N, McNamara LM, Yoganathan AP (2014) An in vitro evaluation of the impact of eccentric deployment on transcatheter aortic valve hemodynamics. Ann Biomed Eng 42(6):1195\u20131206. https:\/\/doi.org\/10.1007\/s10439-014-1008-6","journal-title":"Ann Biomed Eng"},{"key":"9_CR35","unstructured":"IJN NHI (2020) IJN introduces MYVAL, the latest technology to treat aortic stenosis"},{"key":"9_CR36","doi-asserted-by":"crossref","unstructured":"Jamuna C, Abnurajan M (2011) Design of patient specific prosthetic aortic valve and to study its computational fluid dynamics. In: 3rd international conference on electronics computer technology, vol 3, pp 355\u2013360","DOI":"10.1109\/ICECTECH.2011.5941771"},{"key":"9_CR37","unstructured":"Kemp IH (2012) Development, testing and fluid structure interaction simulation of a bioprosthetic valve for transcatheter aortic valve implantation"},{"issue":"3","key":"9_CR38","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1007\/s13246-013-0213-1","volume":"36","author":"I Kemp","year":"2013","unstructured":"Kemp I et al (2013) Experimental validation of the fluid-structure interaction simulation of a bioprosthetic aortic heart valve. Australas Phys Eng Sci Med 36(3):363\u2013373. https:\/\/doi.org\/10.1007\/s13246-013-0213-1","journal-title":"Australas Phys Eng Sci Med"},{"issue":"15","key":"9_CR39","doi-asserted-by":"publisher","first-page":"1308","DOI":"10.1093\/eurheartj\/ehx562","volume":"39","author":"WKF Kong","year":"2018","unstructured":"Kong WKF et al (2018) Inter-ethnic differences in valve morphology, valvular dysfunction, and aortopathy between Asian and European patients with bicuspid aortic valve. Eur Heart J 39(15):1308\u20131313. https:\/\/doi.org\/10.1093\/eurheartj\/ehx562","journal-title":"Eur Heart J"},{"issue":"3","key":"9_CR40","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1055\/s-0036-1586492","volume":"65","author":"RU Kuehnel","year":"2017","unstructured":"Kuehnel RU, Hartrumpf M, Erb M, Albes JM (2017) Hemodynamic performance of endovascular valves as valve-in-valve in small stented bioprosthesis. Thorac Cardiovasc Surg 65(3):225\u2013230. https:\/\/doi.org\/10.1055\/s-0036-1586492","journal-title":"Thorac Cardiovasc Surg"},{"key":"9_CR41","doi-asserted-by":"publisher","unstructured":"Figulla L, Neumann HR, Figulla PK, Erbel R, Neumann T (2011) Transcatheter aortic valve implantation: Evidence on safety and efficacy compared with medical therapy. A systematic review of current literature. Clin Res Cardiol 100(4):265\u2013276. https:\/\/doi.org\/10.1007\/s00392-010-0268-x","DOI":"10.1007\/s00392-010-0268-x"},{"issue":"8","key":"9_CR42","doi-asserted-by":"publisher","first-page":"2690","DOI":"10.1007\/s10439-010-0009-3","volume":"38","author":"K Li","year":"2010","unstructured":"Li K, Sun W (2010) Simulated thin pericardial bioprosthetic valve leaflet deformation under static pressure-only loading conditions: implications for percutaneous valves. Ann Biomed Eng 38(8):2690\u20132701. https:\/\/doi.org\/10.1007\/s10439-010-0009-3","journal-title":"Ann Biomed Eng"},{"issue":"5","key":"9_CR43","doi-asserted-by":"publisher","first-page":"1220","DOI":"10.1016\/0735-1097(93)90249-Z","volume":"21","author":"M Lindroos","year":"1993","unstructured":"Lindroos M, Kupari M, Heikkil\u00e4 J, Tilvis R (1993) Prevalence of aortic valve abnormalities in the elderly: an echocardiographic study of a random population sample. J Am Coll Cardiol 21(5):1220\u20131225. https:\/\/doi.org\/10.1016\/0735-1097(93)90249-Z","journal-title":"J Am Coll Cardiol"},{"issue":"5","key":"9_CR44","doi-asserted-by":"publisher","first-page":"54501","DOI":"10.1115\/1.4026576","volume":"136","author":"H Maleki","year":"2014","unstructured":"Maleki H, Shahriari S, Labrosse M, Pibarot P, Kadem L (2014) An in vitro model of aortic stenosis for the assessment of transcatheter aortic valve implantation. J Biomech Eng 136(5):54501. https:\/\/doi.org\/10.1115\/1.4026576","journal-title":"J Biomech Eng"},{"issue":"15","key":"9_CR45","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1161\/CIRCULATIONAHA.111.070086","volume":"125","author":"M Markl","year":"2012","unstructured":"Markl M, Mikati I, Carr J, McCarthy P, Malaisrie SC (2012) Three-dimensional blood flow alterations after transcatheter aortic valve implantation. Circulation 125(15):573\u2013575. https:\/\/doi.org\/10.1161\/CIRCULATIONAHA.111.070086","journal-title":"Circulation"},{"issue":"8","key":"9_CR46","doi-asserted-by":"publisher","first-page":"797","DOI":"10.1093\/ehjci\/jes273","volume":"14","author":"C Meierhofer","year":"2013","unstructured":"Meierhofer C et al (2013) Wall shear stress and flow patterns in the ascending aorta in patients with bicuspid aortic valves differ significantly from tricuspid aortic valves: a prospective study. Eur Heart J Cardiovasc Imaging 14(8):797\u2013804. https:\/\/doi.org\/10.1093\/ehjci\/jes273","journal-title":"Eur Heart J Cardiovasc Imaging"},{"issue":"9540","key":"9_CR47","doi-asserted-by":"publisher","first-page":"1005","DOI":"10.1016\/S0140-6736(06)69208-8","volume":"368","author":"VT Nkomo","year":"2006","unstructured":"Nkomo VT, Gardin JM, Skelton TN, Gottdiener JS, Scott CG, Enriquez-Sarano M (2006) Burden of valvular heart diseases: a population-based study. Lancet 368(9540):1005\u20131011. https:\/\/doi.org\/10.1016\/S0140-6736(06)69208-8","journal-title":"Lancet"},{"issue":"11","key":"9_CR48","doi-asserted-by":"publisher","first-page":"1002","DOI":"10.1016\/j.jacc.2013.05.015","volume":"62","author":"RLJ Osnabrugge","year":"2013","unstructured":"Osnabrugge RLJ et al (2013) Aortic stenosis in the elderly: disease prevalence and number of candidates for transcatheter aortic valve replacement: a meta-analysis and modeling study. J Am Coll Cardiol 62(11):1002\u20131012. https:\/\/doi.org\/10.1016\/j.jacc.2013.05.015","journal-title":"J Am Coll Cardiol"},{"issue":"6","key":"9_CR49","doi-asserted-by":"publisher","first-page":"551","DOI":"10.1007\/s12265-019-09902-4","volume":"12","author":"P Peruzzo","year":"2019","unstructured":"Peruzzo P, Burriesci G, Susin FM, Colli A (2019) In vitro and ex vivo hemodynamic testing of an innovative occluder for paravalvular leak after transcather aortic valve implantation. J Cardiovasc Transl Res 12(6):551\u2013559. https:\/\/doi.org\/10.1007\/s12265-019-09902-4","journal-title":"J Cardiovasc Transl Res"},{"issue":"7","key":"9_CR50","doi-asserted-by":"publisher","first-page":"1034","DOI":"10.1161\/CIRCULATIONAHA.108.778886","volume":"119","author":"P Pibarot","year":"2009","unstructured":"Pibarot P, Dumesnil JG (2009) Prosthetic heart valves: selection of the optimal prosthesis and long-term management. Circulation 119(7):1034\u20131048. https:\/\/doi.org\/10.1161\/CIRCULATIONAHA.108.778886","journal-title":"Circulation"},{"issue":"10","key":"9_CR51","doi-asserted-by":"publisher","first-page":"1925","DOI":"10.1007\/s10554-019-01632-7","volume":"35","author":"O Rahman","year":"2019","unstructured":"Rahman O et al (2019) Interval changes in aortic peak velocity and wall shear stress in patients with bicuspid aortic valve disease. Int J Cardiovasc Imaging 35(10):1925\u20131934. https:\/\/doi.org\/10.1007\/s10554-019-01632-7","journal-title":"Int J Cardiovasc Imaging"},{"key":"9_CR52","doi-asserted-by":"publisher","unstructured":"Rein\u00f6hl J, Von Zur M\u00fchlen C, Moser M, Sorg S, Bode C, Zehender M (2013) TAVI 2012: state of the art. J Thromb Thrombolysis 35(4):419\u2013435. https:\/\/doi.org\/10.1007\/s11239-012-0825-4","DOI":"10.1007\/s11239-012-0825-4"},{"issue":"1","key":"9_CR53","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1007\/s10439-018-02119-7","volume":"47","author":"OM Rotman","year":"2019","unstructured":"Rotman OM et al (2019) Novel polymeric valve for transcatheter aortic valve replacement applications. In vitro hemodynamic study. Ann Biomed Eng 47(1):113\u2013125. https:\/\/doi.org\/10.1007\/s10439-018-02119-7","journal-title":"Ann Biomed Eng"},{"issue":"4","key":"9_CR54","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1007\/s13239-013-0163-5","volume":"4","author":"N Saikrishnan","year":"2013","unstructured":"Saikrishnan N, Gupta S, Yoganathan AP (2013) Hemodynamics of the Boston Scientific LotusTM valve: an in vitro study. Cardiovasc Eng Technol 4(4):427\u2013439. https:\/\/doi.org\/10.1007\/s13239-013-0163-5","journal-title":"Cardiovasc Eng Technol"},{"issue":"3","key":"9_CR55","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1007\/s10237-014-0623-3","volume":"14","author":"N Saikrishnan","year":"2015","unstructured":"Saikrishnan N, Mirabella L, Yoganathan AP (2015) Bicuspid aortic valves are associated with increased wall and turbulence shear stress levels compared to trileaflet aortic valves. Biomech Model Mechanobiol 14(3):577\u2013588. https:\/\/doi.org\/10.1007\/s10237-014-0623-3","journal-title":"Biomech Model Mechanobiol"},{"key":"9_CR56","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.ijcard.2016.01.048","volume":"208","author":"E Salaun","year":"2016","unstructured":"Salaun E et al (2016) Effect of oversizing and elliptical shape of aortic annulus on transcatheter valve hemodynamics: an in vitro study. Int J Cardiol 208:28\u201335. https:\/\/doi.org\/10.1016\/j.ijcard.2016.01.048","journal-title":"Int J Cardiol"},{"issue":"5","key":"9_CR57","doi-asserted-by":"publisher","first-page":"43","DOI":"10.3978\/j.issn.2305-5839.2014.05.04","volume":"2","author":"LN Scotten","year":"2014","unstructured":"Scotten LN, Siegel R (2014) Thrombogenic potential of transcatheter aortic valve implantation with trivial paravalvular leakage. Ann Transl Med 2(5):43\u201352. https:\/\/doi.org\/10.3978\/j.issn.2305-5839.2014.05.04","journal-title":"Ann Transl Med"},{"key":"9_CR58","doi-asserted-by":"publisher","unstructured":"Seaman C, Akingba G, Sucosky P (2014) Steady flow hemodynamic and energy loss measurements in normal and simulated calcified tricuspid and bicuspid aortic valves. J Biomech Eng 136(4):1\u201343. https:\/\/doi.org\/10.1115\/1.4026575","DOI":"10.1115\/1.4026575"},{"issue":"5","key":"9_CR59","doi-asserted-by":"publisher","first-page":"862","DOI":"10.1016\/j.ahj.2010.07.017","volume":"160","author":"MA Sherif","year":"2010","unstructured":"Sherif MA et al (2010) Early hemodynamic and neurohormonal response after transcatheter aortic valve implantation. Am Heart J 160(5):862\u2013869. https:\/\/doi.org\/10.1016\/j.ahj.2010.07.017","journal-title":"Am Heart J"},{"issue":"3","key":"9_CR60","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1007\/s13239-011-0037-7","volume":"2","author":"E Sirois","year":"2011","unstructured":"Sirois E, Wang Q, Sun W (2011) Fluid simulation of a transcatheter aortic valve deployment into a patient-specific aortic root. Cardiovasc Eng Technol 2(3):186\u2013195. https:\/\/doi.org\/10.1007\/s13239-011-0037-7","journal-title":"Cardiovasc Eng Technol"},{"issue":"1","key":"9_CR61","first-page":"53","volume":"20","author":"S St\u00fchle","year":"2011","unstructured":"St\u00fchle S et al (2011) In-vitro investigation of the hemodynamics of the Edwards SapienTM transcatheter heart valve. J Heart Valve Dis 20(1):53\u201363","journal-title":"J Heart Valve Dis"},{"issue":"16","key":"9_CR62","doi-asserted-by":"publisher","first-page":"3085","DOI":"10.1016\/j.jbiomech.2010.08.010","volume":"43","author":"W Sun","year":"2010","unstructured":"Sun W, Li K, Sirois E (2010) Simulated elliptical bioprosthetic valve deformation: implications for asymmetric transcatheter valve deployment. J Biomech 43(16):3085\u20133090. https:\/\/doi.org\/10.1016\/j.jbiomech.2010.08.010","journal-title":"J Biomech"},{"key":"9_CR63","doi-asserted-by":"publisher","unstructured":"Sun L, Chandra S, Sucosky P (2012) Ex vivo evidence for the contribution of hemodynamic shear stress abnormalities to the early pathogenesis of calcific bicuspid aortic valve disease. PLoS One 7(10). https:\/\/doi.org\/10.1371\/journal.pone.0048843","DOI":"10.1371\/journal.pone.0048843"},{"issue":"1","key":"9_CR64","doi-asserted-by":"publisher","first-page":"83","DOI":"10.2217\/fca.09.53","volume":"6","author":"C Tamburino","year":"2010","unstructured":"Tamburino C, Barbanti M, Capodanno D, Ussia GP (2010) Transcatheter aortic valve implantation: what has been done and what is going to be done. Fut Cardiol 6(1):83\u201395","journal-title":"Fut Cardiol"},{"issue":"1","key":"9_CR65","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1007\/s13239-011-0073-3","volume":"3","author":"FPP Tan","year":"2012","unstructured":"Tan FPP et al (2012) Comparison of aortic flow patterns before and after transcatheter aortic valve implantation. Cardiovasc Eng Technol 3(1):123\u2013135. https:\/\/doi.org\/10.1007\/s13239-011-0073-3","journal-title":"Cardiovasc Eng Technol"},{"issue":"1","key":"9_CR66","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13019-020-01255-3","volume":"15","author":"C Thorburn","year":"2020","unstructured":"Thorburn C et al (2020) Three-dimensional printing for assessment of paravalvular leak in transcatheter aortic valve implantation. J Cardiothorac Surg 15(1):1\u20135. https:\/\/doi.org\/10.1186\/s13019-020-01255-3","journal-title":"J Cardiothorac Surg"},{"issue":"2","key":"9_CR67","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1007\/s10047-010-0507-y","volume":"13","author":"S Tokunaga","year":"2010","unstructured":"Tokunaga S, Tominaga R (2010) Artificial valves \u2018up to date\u2019 in Japan. J Artif Organs 13(2):77\u201387. https:\/\/doi.org\/10.1007\/s10047-010-0507-y","journal-title":"J Artif Organs"},{"issue":"1","key":"9_CR68","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1016\/j.medengphy.2012.04.009","volume":"35","author":"S Tzamtzis","year":"2013","unstructured":"Tzamtzis S, Viquerat J, Yap J, Mullen MJ, Burriesci G (2013) Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI). Med Eng Phys 35(1):125\u2013130. https:\/\/doi.org\/10.1016\/j.medengphy.2012.04.009","journal-title":"Med Eng Phys"},{"issue":"4","key":"9_CR69","doi-asserted-by":"publisher","first-page":"416","DOI":"10.1093\/eurheartj\/ehp575","volume":"31","author":"A Vahanian","year":"2010","unstructured":"Vahanian A, Otto CM (2010) Risk stratification of patients with aortic stenosis. Eur Heart J 31(4):416\u2013423. https:\/\/doi.org\/10.1093\/eurheartj\/ehp575","journal-title":"Eur Heart J"},{"issue":"2","key":"9_CR70","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1007\/s10237-017-0962-y","volume":"17","author":"S Wald","year":"2018","unstructured":"Wald S, Liberzon A, Avrahami I (2018) A numerical study of the hemodynamic effect of the aortic valve on coronary flow. Biomech Model Mechanobiol 17(2):319\u2013338. https:\/\/doi.org\/10.1007\/s10237-017-0962-y","journal-title":"Biomech Model Mechanobiol"},{"issue":"5","key":"9_CR71","doi-asserted-by":"publisher","first-page":"1120","DOI":"10.1016\/j.ejcts.2011.02.056","volume":"40","author":"T Walther","year":"2011","unstructured":"Walther T, Dehdashtian MM, Khanna R, Young E, Goldbrunner PJ, Lee W (2011) Trans-catheter valve-in-valve implantation: in vitro hydrodynamic performance of the SAPIEN+cloth trans-catheter heart valve in the Carpentier-Edwards Perimount valves. Eur J Cardiothorac Surg 40(5):1120\u20131126. https:\/\/doi.org\/10.1016\/j.ejcts.2011.02.056","journal-title":"Eur J Cardiothorac Surg"},{"issue":"1","key":"9_CR72","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1007\/s10237-014-0583-7","volume":"14","author":"Q Wang","year":"2014","unstructured":"Wang Q, Kodali S, Primiano C, Sun W (2014) Simulations of transcatheter aortic valve implantation: implications for aortic root rupture. Biomech Model Mechanobiol 14(1):29\u201338. https:\/\/doi.org\/10.1007\/s10237-014-0583-7","journal-title":"Biomech Model Mechanobiol"},{"issue":"7","key":"9_CR73","doi-asserted-by":"publisher","first-page":"755","DOI":"10.1161\/CIRCULATIONAHA.107.698258","volume":"116","author":"JG Webb","year":"2007","unstructured":"Webb JG et al (2007) Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis. Circulation 116(7):755\u2013763. https:\/\/doi.org\/10.1161\/CIRCULATIONAHA.107.698258","journal-title":"Circulation"},{"issue":"6","key":"9_CR74","first-page":"765","volume":"23","author":"AD Wisneski","year":"2014","unstructured":"Wisneski AD et al (2014) Patient-specific finite element analysis of ascending thoracic aortic aneurysm. J Hear Valve Dis 23(6):765\u2013772","journal-title":"J Hear Valve Dis"},{"key":"9_CR75","doi-asserted-by":"publisher","first-page":"1171","DOI":"10.3760\/cma.j.issn.0366-6999.20123100","volume":"6","author":"Y Wu","year":"2013","unstructured":"Wu Y, Zhang J, Shen W, Zhao Q (2013) Transcatheter aortic valve implantation versus surgical aortic valve replacement for severe aortic stenosis: a meta-analysis. Chin Med J (Engl) 6:1171\u20131177. https:\/\/doi.org\/10.3760\/cma.j.issn.0366-6999.20123100","journal-title":"Chin Med J (Engl)"},{"issue":"2","key":"9_CR76","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1038\/ncpcardio0112","volume":"2","author":"MH Yacoub","year":"2005","unstructured":"Yacoub MH, Takkenberg JJM (2005) Will heart valve tissue engineering change the world? Nat Clin Pract Cardiovasc Med 2(2):60\u201361. https:\/\/doi.org\/10.1038\/ncpcardio0112","journal-title":"Nat Clin Pract Cardiovasc Med"},{"key":"9_CR77","doi-asserted-by":"publisher","unstructured":"Yankah CA, Hetzer R (2010) Aortic root surgery. Steinkopff, Heidelberg. https:\/\/doi.org\/10.1007\/978-3-7985-1869-8","DOI":"10.1007\/978-3-7985-1869-8"},{"key":"9_CR78","doi-asserted-by":"publisher","unstructured":"Yap CH, Saikrishnan N, Tamilselvan G, Vasilyev N, Yoganathan AP (2012) The congenital bicuspid aortic valve can experience high-frequency unsteady shear stresses on its leaflet surface. Am J Physiol Hear Circ Physiol 303(6). https:\/\/doi.org\/10.1152\/ajpheart.00829.2011","DOI":"10.1152\/ajpheart.00829.2011"},{"key":"9_CR79","doi-asserted-by":"publisher","unstructured":"Yoganathan AP, He Z, Casey Jones S (2004) Fluid mechanics of heart valves. Annu Rev Biomed Eng 6(1):331\u2013362. https:\/\/doi.org\/10.1146\/annurev.bioeng.6.040803.140111","DOI":"10.1146\/annurev.bioeng.6.040803.140111"},{"issue":"12","key":"9_CR80","doi-asserted-by":"publisher","first-page":"1151","DOI":"10.1111\/j.1525-1594.2011.01331.x","volume":"35","author":"E Young","year":"2011","unstructured":"Young E, Chen J-F, Dong O, Gao S, Massiello A, Fukamachi K (2011) Transcatheter heart valve with variable geometric configuration: in vitro evaluation. Artif Organs 35(12):1151\u20131159. https:\/\/doi.org\/10.1111\/j.1525-1594.2011.01331.x","journal-title":"Artif Organs"}],"container-title":["Lecture Notes in Bioengineering","Proceedings of the Annual Congress of the Asia-Pacific Society for Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-981-97-1920-4_9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,11]],"date-time":"2024-10-11T19:17:29Z","timestamp":1728674249000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-981-97-1920-4_9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024]]},"ISBN":["9789819721108","9789819719204"],"references-count":80,"URL":"https:\/\/doi.org\/10.1007\/978-981-97-1920-4_9","relation":{},"ISSN":["2195-271X","2195-2728"],"issn-type":[{"type":"print","value":"2195-271X"},{"type":"electronic","value":"2195-2728"}],"subject":[],"published":{"date-parts":[[2024]]},"assertion":[{"value":"12 October 2024","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"APSAO","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Annual Congress of the Asia-Pacific Society for Artificial Organs","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Kuala Lumpur","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Malaysia","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2023","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"25 September 2023","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"26 September 2023","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"apsao2023","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}