{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T11:35:18Z","timestamp":1742988918632,"version":"3.40.3"},"publisher-location":"Singapore","reference-count":10,"publisher":"Springer Nature Singapore","isbn-type":[{"type":"print","value":"9789819783168"},{"type":"electronic","value":"9789819783175"}],"license":[{"start":{"date-parts":[[2024,12,23]],"date-time":"2024-12-23T00:00:00Z","timestamp":1734912000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,12,23]],"date-time":"2024-12-23T00:00:00Z","timestamp":1734912000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025]]},"DOI":"10.1007\/978-981-97-8317-5_12","type":"book-chapter","created":{"date-parts":[[2024,12,22]],"date-time":"2024-12-22T10:16:23Z","timestamp":1734862583000},"page":"75-81","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["The Impact of Ventilation Rate on Mitigating the Overheating Risk in Light Steel Framing and Hollow Brick Masonry Buildings"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4324-7006","authenticated-orcid":false,"given":"Ant\u00f3nio","family":"Figueiredo","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9846-6081","authenticated-orcid":false,"given":"Ricardo M. S. F.","family":"Almeida","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5456-1642","authenticated-orcid":false,"given":"Romeu","family":"Vicente","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6295-1333","authenticated-orcid":false,"given":"Victor M.","family":"Ferreira","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2024,12,23]]},"reference":[{"key":"12_CR1","doi-asserted-by":"publisher","unstructured":"Shi, Y., Li, X.: Effect of mechanical ventilation on infiltration rate under stack effect in buildings with multilayer windows. Build. Environ. 170, 106594 (2020). https:\/\/doi.org\/10.1016\/J.BUILDENV.2019.106594","DOI":"10.1016\/J.BUILDENV.2019.106594"},{"key":"12_CR2","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1111\/j.1600-0668.2004.00273.x","volume":"14","author":"J Sundell","year":"2004","unstructured":"Sundell, J.: On the history of indoor air quality and health. Indoor Air Suppl. 14, 51\u201358 (2004). https:\/\/doi.org\/10.1111\/j.1600-0668.2004.00273.x","journal-title":"Indoor Air Suppl."},{"key":"12_CR3","doi-asserted-by":"publisher","first-page":"3059","DOI":"10.1016\/j.enbuild.2011.07.027","volume":"43","author":"S Nabinger","year":"2011","unstructured":"Nabinger, S., Persily, A.: Impacts of airtightening retrofits on ventilation rates and energy consumption in a manufactured home. Energy Build 43, 3059\u20133067 (2011). https:\/\/doi.org\/10.1016\/j.enbuild.2011.07.027","journal-title":"Energy Build"},{"key":"12_CR4","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1016\/S0306-2619(99)00031-8","volume":"63","author":"M Kolokotroni","year":"1999","unstructured":"Kolokotroni, M., Aronis, A.: Cooling-energy reduction in air-conditioned offices by using night ventilation. Appl. Energy 63, 241\u2013253 (1999). https:\/\/doi.org\/10.1016\/S0306-2619(99)00031-8","journal-title":"Appl. Energy"},{"key":"12_CR5","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1016\/S0038-092X(97)00076-5","volume":"61","author":"P Blondeau","year":"1997","unstructured":"Blondeau, P., Sp\u00e9randio, M., Allard, F.: Night ventilation for building cooling in summer. Sol. Energy 61, 327\u2013335 (1997). https:\/\/doi.org\/10.1016\/S0038-092X(97)00076-5","journal-title":"Sol. Energy"},{"key":"12_CR6","doi-asserted-by":"publisher","unstructured":"Santos, H.R.R., Leal, V.M.S.: Energy vs. ventilation rate in buildings: a comprehensive scenario-based assessment in the European context. Energy Build 54, 111\u201321 (2012). https:\/\/doi.org\/10.1016\/j.enbuild.2012.07.040","DOI":"10.1016\/j.enbuild.2012.07.040"},{"key":"12_CR7","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1127\/0941-2948\/2006\/0130","volume":"15","author":"M Kottek","year":"2006","unstructured":"Kottek, M., Grieser, J., Beck, C., Rudolf, B., Rubel, F.: World map of the K\u00f6ppen-Geiger climate classification updated. Meteorol. Z. 15, 259\u2013263 (2006). https:\/\/doi.org\/10.1127\/0941-2948\/2006\/0130","journal-title":"Meteorol. Z."},{"key":"12_CR8","unstructured":"52016\u20131:2017 I. Energy performance of buildings. Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads (2017)"},{"key":"12_CR9","unstructured":"ISO 12569:2017(en). Thermal Performance of Buildings and Materials \u2014 Determination of Specific Airflow Rate in Buildings \u2014 Tracer Gas Dilution Method (2017)"},{"key":"12_CR10","unstructured":"E741\u201323 A. Standard Test Method for Determining Air Change in a Single Zone by Means of a Tracer Gas Dilution (2023)"}],"container-title":["Lecture Notes in Civil Engineering","Multiphysics and Multiscale Building Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-981-97-8317-5_12","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,22]],"date-time":"2024-12-22T11:02:48Z","timestamp":1734865368000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-981-97-8317-5_12"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,23]]},"ISBN":["9789819783168","9789819783175"],"references-count":10,"URL":"https:\/\/doi.org\/10.1007\/978-981-97-8317-5_12","relation":{},"ISSN":["2366-2557","2366-2565"],"issn-type":[{"type":"print","value":"2366-2557"},{"type":"electronic","value":"2366-2565"}],"subject":[],"published":{"date-parts":[[2024,12,23]]},"assertion":[{"value":"23 December 2024","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"The authors declare no conflicts of interest.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Disclosure of Interests"}},{"value":"IABP","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Association of Building Physics","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Toronto, ON","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Canada","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2024","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"25 July 2024","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"27 July 2024","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"9","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"iabp2024","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"https:\/\/www.ibpc2024.org","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}