{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T19:12:19Z","timestamp":1774465939834,"version":"3.50.1"},"reference-count":64,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2019,2,19]],"date-time":"2019-02-19T00:00:00Z","timestamp":1550534400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Anal Bioanal Chem"],"published-print":{"date-parts":[[2019,3]]},"DOI":"10.1007\/s00216-019-01593-9","type":"journal-article","created":{"date-parts":[[2019,2,18]],"date-time":"2019-02-18T23:57:38Z","timestamp":1550534258000},"page":"1839-1862","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":34,"title":["Go with the flow: advances and trends in magnetic flow cytometry"],"prefix":"10.1007","volume":"411","author":[{"given":"Rita","family":"Soares","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7032-599X","authenticated-orcid":false,"given":"Ver\u00f3nica C.","family":"Martins","sequence":"additional","affiliation":[]},{"given":"Rita","family":"Macedo","sequence":"additional","affiliation":[]},{"given":"Filipe A.","family":"Cardoso","sequence":"additional","affiliation":[]},{"given":"Sofia A. M.","family":"Martins","sequence":"additional","affiliation":[]},{"given":"Diogo M.","family":"Caetano","sequence":"additional","affiliation":[]},{"given":"Pedro H.","family":"Fonseca","sequence":"additional","affiliation":[]},{"given":"V\u00e2nia","family":"Silv\u00e9rio","sequence":"additional","affiliation":[]},{"given":"Susana","family":"Cardoso","sequence":"additional","affiliation":[]},{"given":"Paulo P.","family":"Freitas","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2019,2,19]]},"reference":[{"key":"1593_CR1","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1126\/science.80.2069.188","volume":"80","author":"A Moldavan","year":"1934","unstructured":"Moldavan A. Photo-electric technique for the counting of microscopical cells. Science. 1934;80:188\u20139.","journal-title":"Science"},{"key":"1593_CR2","doi-asserted-by":"publisher","first-page":"959","DOI":"10.1039\/C4LC01422G","volume":"15","author":"M Hejazian","year":"2015","unstructured":"Hejazian M, Li W, Nguyen N-T. Lab on a chip for continuous-flow magnetic cell separation. Lab Chip. 2015;15:959\u201370. \n                    https:\/\/doi.org\/10.1039\/C4LC01422G\n                    \n                  .","journal-title":"Lab Chip."},{"key":"1593_CR3","doi-asserted-by":"publisher","first-page":"16601","DOI":"10.1088\/0034-4885\/78\/1\/016601","volume":"78","author":"BD Plouffe","year":"2015","unstructured":"Plouffe BD, Murthy SK, Lewis LH. Fundamentals and application of magnetic particles in cell isolation and enrichment. Rep Prog Phys. 2015;78:16601. \n                    https:\/\/doi.org\/10.1088\/0034-4885\/78\/1\/016601\n                    \n                  .","journal-title":"Rep Prog Phys."},{"key":"1593_CR4","doi-asserted-by":"publisher","first-page":"4873","DOI":"10.1109\/TMAG.2009.2026287","volume":"45","author":"J Loureiro","year":"2009","unstructured":"Loureiro J, Fermon C, Pannetier-Lecoeur M, Arrias G, Ferreira R, Cardoso S, et al. Magnetoresistive detection of magnetic beads flowing at high speed in microfluidic channels. IEEE Trans Magn. 2009;45:4873\u20136. \n                    https:\/\/doi.org\/10.1109\/TMAG.2009.2026287\n                    \n                  .","journal-title":"IEEE Trans Magn."},{"key":"1593_CR5","doi-asserted-by":"publisher","first-page":"2593","DOI":"10.1039\/C8LC00486B","volume":"18","author":"A Ch\u00edcharo","year":"2018","unstructured":"Ch\u00edcharo A, Martins M, Barnsley LC, Taouallah A, Fernandes J, Silva BFB, et al. Enhanced magnetic microcytometer with 3D flow focusing for cell enumeration. Lab Chip. 2018;18:2593\u2013603. \n                    https:\/\/doi.org\/10.1039\/C8LC00486B\n                    \n                  .","journal-title":"Lab Chip."},{"key":"1593_CR6","doi-asserted-by":"publisher","first-page":"17375","DOI":"10.1038\/s41598-017-17388-w","volume":"7","author":"B Tasadduq","year":"2017","unstructured":"Tasadduq B, Lam W, Alexeev A, Sarioglu AF, Sulchek T. Enhancing size based size separation through vertical focus microfluidics using secondary flow in a ridged microchannel. Sci Rep. 2017;7:17375. \n                    https:\/\/doi.org\/10.1038\/s41598-017-17388-w\n                    \n                  .","journal-title":"Sci Rep."},{"key":"1593_CR7","doi-asserted-by":"publisher","first-page":"3489","DOI":"10.1039\/C8AY01017J","volume":"10","author":"Y Zhao","year":"2018","unstructured":"Zhao Y, Li Q, Hu X. Universally applicable three-dimensional hydrodynamic focusing in a single-layer channel for single cell analysis. Anal Methods. 2018;10:3489\u201397. \n                    https:\/\/doi.org\/10.1039\/C8AY01017J\n                    \n                  .","journal-title":"Anal Methods."},{"key":"1593_CR8","doi-asserted-by":"publisher","first-page":"3491","DOI":"10.1038\/s41598-018-21802-2","volume":"8","author":"L Bougas","year":"2018","unstructured":"Bougas L, Langenegger LD, Mora CA, Zeltner M, Stark WJ, Wickenbrock A, et al. Nondestructive in-line sub-picomolar detection of magnetic nanoparticles in flowing complex fluids. Sci Rep. 2018;8:3491. \n                    https:\/\/doi.org\/10.1038\/s41598-018-21802-2\n                    \n                  .","journal-title":"Sci Rep."},{"key":"1593_CR9","doi-asserted-by":"publisher","first-page":"173701","DOI":"10.1063\/1.4948286","volume":"108","author":"K Fodil","year":"2016","unstructured":"Fodil K, Denoual M, Dolabdjian C, Treizebre A, Senez V. In-flow detection of ultra-small magnetic particles by an integrated giant magnetic impedance sensor. Appl Phys Lett. 2016;108:173701. \n                    https:\/\/doi.org\/10.1063\/1.4948286\n                    \n                  .","journal-title":"Appl Phys Lett."},{"key":"1593_CR10","doi-asserted-by":"publisher","first-page":"4553","DOI":"10.1002\/smll.201601166","volume":"12","author":"G Lin","year":"2016","unstructured":"Lin G, Karnaushenko DD, Berm\u00fadez GSC, Schmidt OG, Makarov D. Magnetic suspension array technology: controlled synthesis and screening in microfluidic networks. Small. 2016;12:4553\u201362. \n                    https:\/\/doi.org\/10.1002\/smll.201601166\n                    \n                  .","journal-title":"Small."},{"key":"1593_CR11","doi-asserted-by":"publisher","first-page":"216","DOI":"10.1039\/C4LC01160K","volume":"15","author":"G Lin","year":"2015","unstructured":"Lin G, Makarov D, Medina-Sanchez M, Guix M, Baraban L, Cuniberti G, et al. Magnetofluidic platform for multidimensional magnetic and optical barcoding of droplets. Lab Chip. 2015;15:216\u201324. \n                    https:\/\/doi.org\/10.1039\/c4lc01160k\n                    \n                  .","journal-title":"Lab Chip."},{"key":"1593_CR12","doi-asserted-by":"publisher","first-page":"696","DOI":"10.1039\/C4LC01076K","volume":"15","author":"KW Kim","year":"2015","unstructured":"Kim KW, Reddy V, Torati SR, Hu XH, Sandhu A, Kim CG. On-chip magnetometer for characterization of superparamagnetic nanoparticles. Lab Chip. 2015;15:696\u2013703. \n                    https:\/\/doi.org\/10.1039\/C4LC01076K\n                    \n                  .","journal-title":"Lab Chip."},{"key":"1593_CR13","doi-asserted-by":"publisher","first-page":"4050","DOI":"10.1039\/C4LC00751D","volume":"14","author":"G Lin","year":"2014","unstructured":"Lin G, Makarov D, Melzer M, Si W, Yan C, Schmidt OG. A highly flexible and compact magnetoresistive analytic device. Lab Chip. 2014;14:4050\u20138. \n                    https:\/\/doi.org\/10.1039\/c4lc00751d\n                    \n                  .","journal-title":"Lab Chip."},{"key":"1593_CR14","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1109\/TMAG.2012.2218797","volume":"49","author":"K Fodil","year":"2013","unstructured":"Fodil K, Denoual M, Dolabdjian C, Harnois M, Senez V. Dynamic sensing of magnetic nanoparticles in microchannel using GMI technology. IEEE Trans Magn. 2013;49:93\u20136. \n                    https:\/\/doi.org\/10.1109\/TMAG.2012.2218797\n                    \n                  .","journal-title":"IEEE Trans Magn."},{"key":"1593_CR15","doi-asserted-by":"publisher","first-page":"2548","DOI":"10.1038\/srep02548","volume":"3","author":"G Lin","year":"2013","unstructured":"Lin G, Baraban L, Han L, Karnaushenko D, Makarov D, Cuniberti G, et al. Magnetoresistive emulsion analyzer. Sci Rep. 2013;3:2548.","journal-title":"Sci Rep."},{"key":"1593_CR16","doi-asserted-by":"publisher","first-page":"2284","DOI":"10.1039\/c2ra01062c","volume":"2","author":"M Melzer","year":"2012","unstructured":"Melzer M, Karnaushenko D, Makarov D, Baraban L, Calvimontes A, M\u00f6nch I, et al. Elastic magnetic sensor with isotropic sensitivity for in-flow detection of magnetic objects. RSC Adv. 2012;2:2284\u20138. \n                    https:\/\/doi.org\/10.1039\/C2RA01062C\n                    \n                  .","journal-title":"RSC Adv."},{"key":"1593_CR17","doi-asserted-by":"publisher","first-page":"4783","DOI":"10.1063\/1.1825059","volume":"85","author":"N Pekas","year":"2004","unstructured":"Pekas N, Porter MD, Tondra M, Popple A, Jander A. Giant magnetoresistance monitoring of magnetic picodroplets in an integrated microfluidic system. Appl Phys Lett. 2004;85:4783\u20135. \n                    https:\/\/doi.org\/10.1063\/1.1825059\n                    \n                  .","journal-title":"Appl Phys Lett."},{"key":"1593_CR18","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1016\/j.bios.2018.02.046","volume":"109","author":"M Reisbeck","year":"2018","unstructured":"Reisbeck M, Richter L, Helou MJ, Arlinghaus S, Anton B, van Dommelen I, et al. Hybrid integration of scalable mechanical and magnetophoretic focusing for magnetic flow cytometry. Biosens Bioelectron. 2018;109:98\u2013108. \n                    https:\/\/doi.org\/10.1016\/j.bios.2018.02.046\n                    \n                  .","journal-title":"Biosens Bioelectron."},{"key":"1593_CR19","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TMAG.2018.2835369","volume":"54","author":"A Ch\u00edcharo","year":"2018","unstructured":"Ch\u00edcharo A, Barnsley L, Martins M, Cardoso S, Dieguez L, Espi\u00f1a B, et al. Custom magnet design for a multi-channel magnetic microcytometer. IEEE Trans Magn. 2018;54:1\u20135. \n                    https:\/\/doi.org\/10.1109\/TMAG.2018.2835369\n                    \n                  .","journal-title":"IEEE Trans Magn."},{"key":"1593_CR20","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1016\/j.sna.2011.02.050","volume":"172","author":"A Garc\u00eda-Arribas","year":"2011","unstructured":"Garc\u00eda-Arribas A, Mart\u00ednez F, Fern\u00e1ndez E, Ozaeta I, Kurlyandskaya GV, Svalov AV, et al. GMI detection of magnetic-particle concentration in continuous flow. Sensors Actuators A Phys. 2011;172:103\u20138. \n                    https:\/\/doi.org\/10.1016\/j.sna.2011.02.050\n                    \n                  .","journal-title":"Sensors Actuators A Phys."},{"key":"1593_CR21","doi-asserted-by":"publisher","first-page":"7436","DOI":"10.1021\/nn202351j","volume":"5","author":"I M\u00f6nch","year":"2011","unstructured":"M\u00f6nch I, Makarov D, Koseva R, Baraban L, Karnaushenko D, Kaiser C, et al. Rolled-up magnetic sensor: nanomembrane architecture for in-flow detection of magnetic objects. ACS Nano. 2011;5:7436\u201342. \n                    https:\/\/doi.org\/10.1021\/nn202351j\n                    \n                  .","journal-title":"ACS Nano."},{"key":"1593_CR22","doi-asserted-by":"publisher","first-page":"L69","DOI":"10.1016\/j.jmmm.2010.08.006","volume":"322","author":"K Aledealat","year":"2010","unstructured":"Aledealat K, Mihajlovi\u0107 G, Chen K, Field M, Sullivan GJ, Xiong P, et al. Dynamic micro-Hall detection of superparamagnetic beads in a microfluidic channel. J Magn Magn Mater. 2010;322:L69\u201372. \n                    https:\/\/doi.org\/10.1016\/j.jmmm.2010.08.006\n                    \n                  .","journal-title":"J Magn Magn Mater."},{"key":"1593_CR23","doi-asserted-by":"publisher","first-page":"34104","DOI":"10.1063\/1.3182791","volume":"95","author":"J Loureiro","year":"2009","unstructured":"Loureiro J, Ferreira R, Cardoso S, Freitas PP, Germano J, Fermon C, et al. Toward a magnetoresistive chip cytometer: integrated detection of magnetic beads flowing at cm\/s velocities in microfluidic channels. Appl Phys Lett. 2009;95:34104. \n                    https:\/\/doi.org\/10.1063\/1.3182791\n                    \n                  .","journal-title":"Appl Phys Lett."},{"key":"1593_CR24","doi-asserted-by":"publisher","first-page":"253901","DOI":"10.1063\/1.1952582","volume":"86","author":"W Shen","year":"2005","unstructured":"Shen W, Liu X, Mazumdar D, Xiao G. In situ detection of single micron-sized magnetic beads using magnetic tunnel junction sensors. Appl Phys Lett. 2005;86:253901. \n                    https:\/\/doi.org\/10.1063\/1.1952582\n                    \n                  .","journal-title":"Appl Phys Lett."},{"key":"1593_CR25","doi-asserted-by":"publisher","first-page":"2652","DOI":"10.1109\/TMAG.2004.830403","volume":"40","author":"HA Ferreira","year":"2004","unstructured":"Ferreira HA, Graham DL, Parracho P, Soares V, Freitas PP. Flow velocity measurement in microchannels using magnetoresistive chips. IEEE Trans Magn. 2004;40:2652\u20134. \n                    https:\/\/doi.org\/10.1109\/TMAG.2004.830403\n                    \n                  .","journal-title":"IEEE Trans Magn."},{"key":"1593_CR26","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1109\/JSSC.2016.2621036","volume":"52","author":"P Murali","year":"2017","unstructured":"Murali P, Niknejad AM, Boser BE. CMOS microflow cytometer for magnetic label detection and classification. IEEE J Solid-State Circuits. 2017;52:543\u201355. \n                    https:\/\/doi.org\/10.1109\/JSSC.2016.2621036\n                    \n                  .","journal-title":"IEEE J Solid-State Circuits."},{"key":"1593_CR27","doi-asserted-by":"publisher","first-page":"32838","DOI":"10.1038\/srep32838","volume":"6","author":"M Reisbeck","year":"2016","unstructured":"Reisbeck M, Helou MJ, Richter L, Kappes B, Friedrich O, Hayden O. Magnetic fingerprints of rolling cells for quantitative flow cytometry in whole blood. Sci Rep. 2016;6:32838.","journal-title":"Sci Rep."},{"key":"1593_CR28","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.bios.2014.01.028","volume":"57","author":"C-P Lee","year":"2014","unstructured":"Lee C-P, Lai M-F, Huang H-T, Lin C-W, Wei Z-H. Wheatstone bridge giant-magnetoresistance based cell counter. Biosens Bioelectron. 2014;57:48\u201353. \n                    https:\/\/doi.org\/10.1016\/j.bios.2014.01.028\n                    \n                  .","journal-title":"Biosens Bioelectron."},{"key":"1593_CR29","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TMAG.2014.2324411","volume":"50","author":"A Vila","year":"2014","unstructured":"Vila A, Martins VC, Ch\u00edcharo A, Rodriguez-Abreu C, Fernandes AC, Cardoso FA, et al. Customized design of magnetic beads for dynamic magnetoresistive cytometry. IEEE Trans Magn. 2014;50:1\u20134. \n                    https:\/\/doi.org\/10.1109\/TMAG.2014.2324411\n                    \n                  .","journal-title":"IEEE Trans Magn."},{"key":"1593_CR30","doi-asserted-by":"publisher","unstructured":"Boser BE, Murali P. Flow cytometer-on-a-chip. In: 2014 IEEE Biomedical Circuits and Systems Conference (BioCAS) Proceedings. Lausanne; 2014. p. 480\u2013483. \n                    https:\/\/doi.org\/10.1109\/BioCAS.2014.6981767\n                    \n                  .","DOI":"10.1109\/BioCAS.2014.6981767"},{"key":"1593_CR31","doi-asserted-by":"publisher","first-page":"141ra92","DOI":"10.1126\/scitranslmed.3003747","volume":"4","author":"D Issadore","year":"2012","unstructured":"Issadore D, Chung J, Shao H, Liong M, Ghazani AA, Castro CM, et al. Ultrasensitive clinical enumeration of rare cells ex vivo using a \u03bc-Hall detector. Sci Transl Med. 2012;4:141ra92. \n                    https:\/\/doi.org\/10.1126\/scitranslmed.3003747\n                    \n                  .","journal-title":"Sci Transl Med"},{"key":"1593_CR32","doi-asserted-by":"publisher","first-page":"2255","DOI":"10.1039\/c0lc00324g","volume":"11","author":"J Loureiro","year":"2011","unstructured":"Loureiro J, Andrade PZ, Cardoso S, da Silva CL, Cabral JM, Freitas PP. Magnetoresistive chip cytometer. Lab Chip. 2011;11:2255\u201361. \n                    https:\/\/doi.org\/10.1039\/c0lc00324g\n                    \n                  .","journal-title":"Lab Chip."},{"key":"1593_CR33","doi-asserted-by":"publisher","first-page":"19","DOI":"10.3390\/bios6020019","volume":"6","author":"C Duarte","year":"2016","unstructured":"Duarte C, Costa T, Carneiro C, Soares R, Jitariu A, Cardoso S, et al. Semi-quantitative method for Streptococci magnetic detection in raw milk. Biosensors. 2016;6:19. \n                    https:\/\/doi.org\/10.3390\/bios6020019\n                    \n                  .","journal-title":"Biosensors."},{"key":"1593_CR34","doi-asserted-by":"publisher","first-page":"15496","DOI":"10.3390\/s140815496","volume":"14","author":"AC Fernandes","year":"2014","unstructured":"Fernandes AC, Duarte CM, Cardoso FA, Bexiga R, Cardoso S, Freitas PP. Lab-on-Chip cytometry based on magnetoresistive sensors for bacteria detection in milk. Sensors (Basel). 2014;14:15496\u2013524. \n                    https:\/\/doi.org\/10.3390\/s140815496\n                    \n                  .","journal-title":"Sensors (Basel)"},{"key":"1593_CR35","doi-asserted-by":"publisher","first-page":"1224","DOI":"10.1002\/adhm.201200380","volume":"2","author":"D Issadore","year":"2013","unstructured":"Issadore D, Chung HJ, Chung J, Budin G, Weissleder R, Lee H. muHall chip for sensitive detection of bacteria. Adv Healthc Mater. 2013;2:1224\u20138. \n                    https:\/\/doi.org\/10.1002\/adhm.201200380\n                    \n                  .","journal-title":"Adv Healthc Mater."},{"key":"1593_CR36","doi-asserted-by":"publisher","first-page":"1018","DOI":"10.1109\/TMAG.1975.1058782","volume":"11","author":"T McGuire","year":"1975","unstructured":"McGuire T, Potter R. Anisotropic magnetoresistance in ferromagnetic 3d alloys. IEEE Trans Magn. 1975;11:1018\u201338. \n                    https:\/\/doi.org\/10.1109\/TMAG.1975.1058782\n                    \n                  .","journal-title":"IEEE Trans Magn."},{"key":"1593_CR37","doi-asserted-by":"publisher","first-page":"6152","DOI":"10.1063\/1.366533","volume":"82","author":"RJM Veerdonk van de","year":"1997","unstructured":"van de Veerdonk RJM, Beli\u00ebn PJL, Schep KM, Kools JCS, de Nooijer MC, Gijs MAM, et al. 1\/f noise in anisotropic and giant magnetoresistive elements. J Appl Phys. 1997;82:6152\u201364. \n                    https:\/\/doi.org\/10.1063\/1.366533\n                    \n                  .","journal-title":"J Appl Phys."},{"key":"1593_CR38","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1016\/0924-4247(96)01152-1","volume":"53","author":"F Nguyen Van Dau","year":"1996","unstructured":"Nguyen Van Dau F, Schuhl A, Childress JR, Sussiau M. Magnetic sensors for nanotesla detection using planar Hall effect. Sensors Actuators A Phys. 1996;53:256\u201360. \n                    https:\/\/doi.org\/10.1016\/0924-4247(96)01152-1\n                    \n                  .","journal-title":"Sensors Actuators A Phys"},{"key":"1593_CR39","doi-asserted-by":"publisher","first-page":"4729","DOI":"10.1063\/1.1759380","volume":"84","author":"L Ejsing","year":"2004","unstructured":"Ejsing L, Hansen MF, Menon AK, Ferreira HA, Graham DL, Freitas PP. Planar Hall effect sensor for magnetic micro- and nanobead detection. Appl Phys Lett. 2004;84:4729\u201331. \n                    https:\/\/doi.org\/10.1063\/1.1759380\n                    \n                  .","journal-title":"Appl Phys Lett."},{"issue":"7","key":"1593_CR40","doi-asserted-by":"publisher","first-page":"07A302","DOI":"10.1063\/1.2830008","volume":"103","author":"C Damsgaard","year":"2008","unstructured":"Damsgaard C, Cardoso S, Freitas P, Hansen M. Exchange-biased planar Hall effect sensor optimized for biosensor applications. J Appl Phys. 2008;103(7):07A302\u201307A302-3.","journal-title":"J Appl Phys"},{"key":"1593_CR41","unstructured":"Freitas P, Ferreira H, Graham D, Clarke L, Amaral M, Martins V, et al. Magnetoresistive biochips E. In: Johnson M, editor. Magnetoelectronics. Amsterdam: Elsevier."},{"key":"1593_CR42","doi-asserted-by":"publisher","first-page":"2472","DOI":"10.1103\/PhysRevLett.61.2472","volume":"61","author":"MN Baibich","year":"1988","unstructured":"Baibich MN, Broto JM, Fert A, Van Dau FN, Petroff F, Etienne P, et al. Giant magnetoresistance of (001)Fe\/(001)Cr magnetic superlattices. Phys Rev Lett. 1988;61:2472\u20135. \n                    https:\/\/doi.org\/10.1103\/PhysRevLett.61.2472\n                    \n                  .","journal-title":"Phys Rev Lett."},{"key":"1593_CR43","doi-asserted-by":"publisher","first-page":"4828","DOI":"10.1103\/PhysRevB.39.4828","volume":"39","author":"G Binasch","year":"1989","unstructured":"Binasch G, Gr\u00fcnberg P, Saurenbach F, Zinn W. Enhanced magnetoresistance in layered magnetic structures with antiferromagnetic interlayer exchange. Phys Rev B. 1989;39:4828\u201330. \n                    https:\/\/doi.org\/10.1103\/PhysRevB.39.4828\n                    \n                  .","journal-title":"Phys Rev B."},{"key":"1593_CR44","doi-asserted-by":"publisher","first-page":"1297","DOI":"10.1103\/PhysRevB.43.1297","volume":"43","author":"B Dieny","year":"1991","unstructured":"Dieny B, Speriosu VS, Parkin SSP, Gurney BA, Wilhoit DR, Mauri D. Giant magnetoresistive in soft ferromagnetic multilayers. Phys Rev B. 1991;43:1297\u2013300. \n                    https:\/\/doi.org\/10.1103\/PhysRevB.43.1297\n                    \n                  .","journal-title":"Phys Rev B."},{"key":"1593_CR45","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1109\/20.312279","volume":"30","author":"DE Heim","year":"1994","unstructured":"Heim DE, Fontana RE, Tsang C, Speriosu VS, Gurney BA, Williams ML. Design and operation of spin valve sensors. IEEE Trans Magn. 1994;30:316\u201321. \n                    https:\/\/doi.org\/10.1109\/20.312279\n                    \n                  .","journal-title":"IEEE Trans Magn."},{"key":"1593_CR46","doi-asserted-by":"publisher","first-page":"165221","DOI":"10.1088\/0953-8984\/19\/16\/165221","volume":"19","author":"PP Freitas","year":"2007","unstructured":"Freitas PP, Ferreira R, Cardoso S, Cardoso F. Magnetoresistive sensors. J Phys Condens Matter. 2007;19:165221. \n                    https:\/\/doi.org\/10.1088\/0953-8984\/19\/16\/165221\n                    \n                  .","journal-title":"J Phys Condens Matter."},{"key":"1593_CR47","doi-asserted-by":"publisher","first-page":"232510","DOI":"10.1063\/1.2402904","volume":"89","author":"J Hayakawa","year":"2006","unstructured":"Hayakawa J, Ikeda S, Lee YM, Matsukura F, Ohno H. Effect of high annealing temperature on giant tunnel magnetoresistance ratio of CoFeB\/MgO\/CoFeB magnetic tunnel junctions. Appl Phys Lett. 2006;89:232510. \n                    https:\/\/doi.org\/10.1063\/1.2402904\n                    \n                  .","journal-title":"Appl Phys Lett."},{"key":"1593_CR48","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1016\/j.tibtech.2004.06.006","volume":"22","author":"DL Graham","year":"2004","unstructured":"Graham DL, Ferreira HA, Freitas PP. Magnetoresistive-based biosensors and biochips. Trends Biotechnol. 2004;22:455\u201362. \n                    https:\/\/doi.org\/10.1016\/j.tibtech.2004.06.006\n                    \n                  .","journal-title":"Trends Biotechnol."},{"key":"1593_CR49","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1038\/nnano.2010.274","volume":"6","author":"E Krieg","year":"2011","unstructured":"Krieg E, Weissman H, Shirman E, Shimoni E, Rybtchinski B. A recyclable supramolecular membrane for size-selective separation of nanoparticles. Nature Nanotechnol. 2011;6:141\u20136. \n                    https:\/\/doi.org\/10.1038\/nnano.2010.274\n                    \n                  .","journal-title":"Nature Nanotechnol."},{"key":"1593_CR50","doi-asserted-by":"publisher","first-page":"27494","DOI":"10.1038\/srep27494","volume":"6","author":"JD Robertson","year":"2016","unstructured":"Robertson JD, Rizzello L, Avi M, Gaitzsch J. Purification of nanoparticles by size and shape. Sci Rep. 2016;6:27494. \n                    https:\/\/doi.org\/10.1038\/srep27494\n                    \n                  .","journal-title":"Sci Rep."},{"key":"1593_CR51","doi-asserted-by":"publisher","first-page":"1035","DOI":"10.1039\/c3lc41310a","volume":"13","author":"M Helou","year":"2013","unstructured":"Helou M, Reisbeck M, Tedde SF, Richter L, B\u00e4r L, Bosch JJ, et al. Time-of-flight magnetic flow cytometry in whole blood with integrated sample preparation. Lab Chip. 2013;13:1035\u20138. \n                    https:\/\/doi.org\/10.1039\/c3lc41310a\n                    \n                  .","journal-title":"Lab Chip."},{"key":"1593_CR52","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1007\/978-1-61779-915-0_13","volume-title":"Molecular biological technologies for ocean sensing","author":"SSA Martins","year":"2012","unstructured":"Martins SSA, Martins VC, Cardoso FA, Freitas PP, Fonseca LP. Waterborne pathogen detection using a magnetoresistive immuno-chip BT. In: Tiquia-Arashiro SM, editor. Molecular biological technologies for ocean sensing. Totowa: Humana; 2012. p. 263\u201388."},{"key":"1593_CR53","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1016\/j.jpba.2014.04.017","volume":"101","author":"J He","year":"2014","unstructured":"He J, Huang M, Wang D, Zhang Z, Li G. Magnetic separation techniques in sample preparation for biological analysis: a review. J Pharm Biomed Anal. 2014;101:84\u2013101. \n                    https:\/\/doi.org\/10.1016\/j.jpba.2014.04.017\n                    \n                  .","journal-title":"J Pharm Biomed Anal."},{"key":"1593_CR54","doi-asserted-by":"publisher","first-page":"1108","DOI":"10.1109\/JSEN.2010.2043429","volume":"10","author":"P Ripka","year":"2010","unstructured":"Ripka P, Janosek M. Advances in magnetic field sensors. IEEE Sens J. 2010;10:1108\u201316. \n                    https:\/\/doi.org\/10.1109\/JSEN.2010.2043429\n                    \n                  .","journal-title":"IEEE Sens J."},{"key":"1593_CR55","doi-asserted-by":"publisher","first-page":"1.20.1","DOI":"10.1002\/0471142956.cy0120s40","volume":"40","author":"RA Hoffman","year":"2007","unstructured":"Hoffman RA, Wood JCS. Characterization of flow cytometer instrument sensitivity. Curr Protoc Cytom. 2007;40:1.20.1\u20131.20.18. \n                    https:\/\/doi.org\/10.1002\/0471142956.cy0120s40\n                    \n                  .","journal-title":"Curr Protoc Cytom."},{"key":"1593_CR56","doi-asserted-by":"publisher","first-page":"08S105","DOI":"10.1063\/1.2176238","volume":"99","author":"Z Jiang","year":"2006","unstructured":"Jiang Z, Llandro J, Mitrelias T, Bland JAC. An integrated microfluidic cell for detection, manipulation, and sorting of single micron-sized magnetic beads. J Appl Phys. 2006;99:08S105. \n                    https:\/\/doi.org\/10.1063\/1.2176238\n                    \n                  .","journal-title":"J Appl Phys"},{"key":"1593_CR57","doi-asserted-by":"publisher","first-page":"1044","DOI":"10.1039\/C3LC51152A","volume":"14","author":"ME Piyasena","year":"2014","unstructured":"Piyasena ME, Graves SW. The intersection of flow cytometry with microfluidics and microfabrication. Lab Chip. 2014;14:1044\u201359. \n                    https:\/\/doi.org\/10.1039\/C3LC51152A\n                    \n                  .","journal-title":"Lab Chip."},{"issue":"4","key":"1593_CR58","doi-asserted-by":"publisher","first-page":"4674","DOI":"10.3390\/s130404674","volume":"13","author":"M Frankowski","year":"2013","unstructured":"Frankowski M, Theisen J, Kummrow A, Simon P, Ragusch H, Bock N, et al. Microflow cytometers with integrated hydrodynamic focusing. Sensors (Basel). 2013;13(4):4674\u201393.","journal-title":"Sensors (Basel)"},{"key":"1593_CR59","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1039\/b209333b","volume":"3","author":"A Wolff","year":"2003","unstructured":"Wolff A, Perch-Nielsen IR, Larsen UD, Friis P, Goranovic G, Poulsen CR, et al. Integrating advanced functionality in a microfabricated high-throughput fluorescent-activated cell sorter. Lab Chip. 2003;3:22\u20137. \n                    https:\/\/doi.org\/10.1039\/b209333b\n                    \n                  .","journal-title":"Lab Chip."},{"key":"1593_CR60","doi-asserted-by":"publisher","first-page":"102014","DOI":"10.1063\/1.3116091","volume":"105","author":"C Liu","year":"2009","unstructured":"Liu C, Stakenborg T, Peeters S, Lagae L. Cell manipulation with magnetic particles toward microfluidic cytometry. J Appl Phys. 2009;105:102014. \n                    https:\/\/doi.org\/10.1063\/1.3116091\n                    \n                  .","journal-title":"J Appl Phys."},{"key":"1593_CR61","doi-asserted-by":"publisher","unstructured":"Huang C, Zhou X, Ying D, Hall DA. A GMR-based magnetic flow cytometer using matched filtering. In: 2017 IEEE Sensors. Glasgow, 2017. p. 1\u20133. \n                    https:\/\/doi.org\/10.1109\/ICSENS.2017.8233892\n                    \n                  .","DOI":"10.1109\/ICSENS.2017.8233892"},{"key":"1593_CR62","doi-asserted-by":"publisher","first-page":"12967","DOI":"10.1038\/s41598-017-13389-x","volume":"7","author":"X Sun","year":"2017","unstructured":"Sun X, Feng Z, Zhi S, Lei C, Zhang D, Zhou Y. An integrated microfluidic system using a micro-fluxgate and micro spiral coil for magnetic microbeads trapping and detecting. Sci Rep. 2017;7:12967. \n                    https:\/\/doi.org\/10.1038\/s41598-017-13389-x\n                    \n                  .","journal-title":"Sci Rep."},{"key":"1593_CR63","doi-asserted-by":"publisher","first-page":"3784","DOI":"10.1109\/TMAG.2012.2198449","volume":"48","author":"FA Cardoso","year":"2012","unstructured":"Cardoso FA, Costa T, Germano J, Cardoso S, Borme J, Gaspar J, et al. Integration of magnetoresistive biochips on a CMOS circuit. IEEE Trans Magn. 2012;48:3784\u20137. \n                    https:\/\/doi.org\/10.1109\/TMAG.2012.2198449\n                    \n                  .","journal-title":"IEEE Trans Magn."},{"key":"1593_CR64","doi-asserted-by":"publisher","first-page":"988","DOI":"10.1109\/TBCAS.2017.2743685","volume":"11","author":"T Costa","year":"2017","unstructured":"Costa T, Cardoso FA, Germano J, Freitas PP, Piedade MS. A CMOS front-end with integrated magnetoresistive sensors for biomolecular recognition detection applications. IEEE Trans Biomed Circuits Syst. 2017;11:988\u20131000. \n                    https:\/\/doi.org\/10.1109\/TBCAS.2017.2743685\n                    \n                  .","journal-title":"IEEE Trans Biomed Circuits Syst."}],"container-title":["Analytical and Bioanalytical Chemistry"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00216-019-01593-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-019-01593-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-019-01593-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,2,18]],"date-time":"2020-02-18T19:09:43Z","timestamp":1582052983000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00216-019-01593-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2,19]]},"references-count":64,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2019,3]]}},"alternative-id":["1593"],"URL":"https:\/\/doi.org\/10.1007\/s00216-019-01593-9","relation":{},"ISSN":["1618-2642","1618-2650"],"issn-type":[{"value":"1618-2642","type":"print"},{"value":"1618-2650","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,2,19]]},"assertion":[{"value":"30 September 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 December 2018","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 January 2019","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 February 2019","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"No experiments involving human participants and\/or animals have been conducted for this publication.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}