{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,8]],"date-time":"2026-04-08T10:38:42Z","timestamp":1775644722473,"version":"3.50.1"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"30","license":[{"start":{"date-parts":[[2021,10,15]],"date-time":"2021-10-15T00:00:00Z","timestamp":1634256000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,10,15]],"date-time":"2021-10-15T00:00:00Z","timestamp":1634256000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100001871","name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia","doi-asserted-by":"publisher","award":["SFRH\/BD\/144962\/2019"],"award-info":[{"award-number":["SFRH\/BD\/144962\/2019"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001871","name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia","doi-asserted-by":"publisher","award":["UIDB\/50016\/2020"],"award-info":[{"award-number":["UIDB\/50016\/2020"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Anal Bioanal Chem"],"published-print":{"date-parts":[[2021,12]]},"DOI":"10.1007\/s00216-021-03706-9","type":"journal-article","created":{"date-parts":[[2021,10,15]],"date-time":"2021-10-15T21:05:59Z","timestamp":1634331959000},"page":"7463-7472","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":23,"title":["New microfluidic paper-based analytical device for iron determination in urine samples"],"prefix":"10.1007","volume":"413","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3921-3973","authenticated-orcid":false,"given":"Francisca T. S. M.","family":"Ferreira","sequence":"first","affiliation":[]},{"given":"Karina A.","family":"Catal\u00e3o","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7745-1860","authenticated-orcid":false,"given":"Raquel B. R.","family":"Mesquita","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6486-8947","authenticated-orcid":false,"given":"Ant\u00f3nio O. S. S.","family":"Rangel","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2021,10,15]]},"reference":[{"key":"3706_CR1","unstructured":"Linus Pauling Institute (2016) Iron | Linus Pauling Institute | Oregon State University. https:\/\/lpi.oregonstate.edu\/mic\/minerals\/iron. Accessed 7 Sep 2020."},{"key":"3706_CR2","doi-asserted-by":"publisher","first-page":"458","DOI":"10.1159\/000488470","volume":"43","author":"S Nakatani","year":"2018","unstructured":"Nakatani S, Nakatani A, Ishimura E, Toi N, Tsuda A, Mori K, Emoto M, Hirayama Y, Saito A, Inaba M. Urinary iron excretion is associated with urinary full-length megalin and renal oxidative stress in chronic kidney disease. Kidney Blood Press Res. 2018;43:458\u201370. https:\/\/doi.org\/10.1159\/000488470.","journal-title":"Kidney Blood Press Res"},{"key":"3706_CR3","unstructured":"Marshfield Labs Iron, Urine (FEU). https:\/\/www.marshfieldlabs.org\/sites\/ltrm\/Human\/Pages\/22804.aspx. Accessed 7 Sep 2020."},{"key":"3706_CR4","unstructured":"Iron, Urine. http:\/\/www.labnet.health.nz\/testmanager\/index.php?fuseaction=main.DisplayTest&testid=284. Accessed 17 Sep 2020."},{"key":"3706_CR5","unstructured":"Iron, Urine - NMS Labs. https:\/\/www.nmslabs.com\/tests\/2430U. Accessed 17 Sep 2020."},{"key":"3706_CR6","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1086\/499363","volume":"42","author":"CA Petti","year":"2006","unstructured":"Petti CA, Polage CR, Quinn TC, Ronald AR, Sande MA. Laboratory medicine in Africa: a barrier to effective health care. Clin Infect Dis. 2006;42:377\u201382. https:\/\/doi.org\/10.1086\/499363.","journal-title":"Clin Infect Dis"},{"key":"3706_CR7","doi-asserted-by":"publisher","first-page":"200","DOI":"10.3390\/DIAGNOSTICS5020200","volume":"5","author":"R McNerney","year":"2015","unstructured":"McNerney R. Diagnostics for developing countries. Diagnostics. 2015;5:200. https:\/\/doi.org\/10.3390\/DIAGNOSTICS5020200.","journal-title":"Diagnostics"},{"key":"3706_CR8","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1016\/J.TALANTA.2017.08.072","volume":"177","author":"MIGS Almeida","year":"2018","unstructured":"Almeida MIGS, Jayawardane BM, Kolev SD, McKelvie ID. Developments of microfluidic paper-based analytical devices (\u03bcPADs) for water analysis: a review. Talanta. 2018;177:176\u201390. https:\/\/doi.org\/10.1016\/J.TALANTA.2017.08.072.","journal-title":"Talanta"},{"key":"3706_CR9","doi-asserted-by":"publisher","first-page":"1340","DOI":"10.1002\/ange.200603817","volume":"119","author":"AW Martinez","year":"2007","unstructured":"Martinez AW, Phillips ST, Butte MJ, Whitesides GM. Patterned paper as a platform for inexpensive, low-volume, portable bioassays. Angew Chem. 2007;119:1340\u20132. https:\/\/doi.org\/10.1002\/ange.200603817.","journal-title":"Angew Chem"},{"key":"3706_CR10","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1146\/annurev-anchem-071015-041714","volume":"9","author":"X Jiang","year":"2016","unstructured":"Jiang X, Fan ZH. Fabrication and operation of paper-based analytical devices. Annu Rev Anal Chem. 2016;9:203\u201322. https:\/\/doi.org\/10.1146\/annurev-anchem-071015-041714.","journal-title":"Annu Rev Anal Chem"},{"key":"3706_CR11","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1021\/ac9013989","volume":"82","author":"AW Martinez","year":"2010","unstructured":"Martinez AW, Phillips ST, Whitesides GM, Carrilho E. Diagnostics for the developing world: microfluidic paper-based analytical devices. Anal Chem. 2010;82:3\u201310. https:\/\/doi.org\/10.1021\/ac9013989.","journal-title":"Anal Chem"},{"key":"3706_CR12","unstructured":"Paper microfluidic devices\u202f: a review 2017 - Elveflow. https:\/\/www.elveflow.com\/microfluidic-tutorials\/microfluidic-reviews-and-tutorials\/paper-microfluidic-devices-a-review-2017\/. Accessed 13 Dec 2018."},{"key":"3706_CR13","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1016\/S0009-8981(03)00168-2","volume":"333","author":"NC Birch","year":"2003","unstructured":"Birch NC, Stickle DF. Example of use of a desktop scanner for data acquisition in a colorimetric assay. Clin Chim Acta. 2003;333:95\u20136. https:\/\/doi.org\/10.1016\/S0009-8981(03)00168-2.","journal-title":"Clin Chim Acta"},{"key":"3706_CR14","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1016\/j.aca.2016.03.030","volume":"919","author":"AN Ramdzan","year":"2016","unstructured":"Ramdzan AN, Almeida MIGS, McCullough MJ, Kolev SD. Development of a microfluidic paper-based analytical device for the determination of salivary aldehydes. Anal Chim Acta. 2016;919:47\u201354. https:\/\/doi.org\/10.1016\/j.aca.2016.03.030.","journal-title":"Anal Chim Acta"},{"key":"3706_CR15","doi-asserted-by":"publisher","first-page":"85","DOI":"10.3390\/medicines6030085","volume":"6","author":"A Yiannikourides","year":"2019","unstructured":"Yiannikourides A, Latunde-Dada G. A short review of iron metabolism and pathophysiology of iron disorders. Medicines. 2019;6:85. https:\/\/doi.org\/10.3390\/medicines6030085.","journal-title":"Medicines"},{"key":"3706_CR16","unstructured":"Ems T, Lucia KS, Huecker MR (article editor) (2019) Biochemistry, Iron Absorption. StatPearls Publishing Bookshelf ID:NBK448204"},{"key":"3706_CR17","doi-asserted-by":"publisher","first-page":"120887","DOI":"10.1016\/j.talanta.2020.120887","volume":"214","author":"T Moniz","year":"2020","unstructured":"Moniz T, Bassett CR, Almeida MIGS, Kolev SD, Rangel M, Mesquita RBR. Use of an ether-derived 3-hydroxy-4-pyridinone chelator as a new chromogenic reagent in the development of a microfluidic paper-based analytical device for Fe(III) determination in natural waters. Talanta. 2020;214:120887. https:\/\/doi.org\/10.1016\/j.talanta.2020.120887.","journal-title":"Talanta"},{"key":"3706_CR18","doi-asserted-by":"publisher","first-page":"31","DOI":"10.2116\/analsci.32.31","volume":"32","author":"K Ogawa","year":"2016","unstructured":"Ogawa K, Kaneta T. Determination of iron ion in the water of a natural hot spring using microfluidic paper-based analytical devices. Anal Sci. 2016;32:31\u20134. https:\/\/doi.org\/10.2116\/analsci.32.31.","journal-title":"Anal Sci"},{"key":"3706_CR19","doi-asserted-by":"publisher","first-page":"1573","DOI":"10.1007\/s00216-019-02385-x","volume":"412","author":"K Shrivas","year":"2020","unstructured":"Shrivas K, Monisha KT, Karbhal I, Kurrey R, Sahu B, Sinha D, Patra GK, Deb MK, Pervez S. Smartphone coupled with paper-based chemical sensor for on-site determination of iron(III) in environmental and biological samples. Anal Bioanal Chem. 2020;412:1573\u201383. https:\/\/doi.org\/10.1007\/s00216-019-02385-x.","journal-title":"Anal Bioanal Chem"},{"key":"3706_CR20","doi-asserted-by":"publisher","first-page":"121183","DOI":"10.1016\/j.talanta.2020.121183","volume":"219","author":"FTSM Ferreira","year":"2020","unstructured":"Ferreira FTSM, Mesquita RBR, Rangel AOSS. Novel microfluidic paper-based analytical devices (\u03bcPADs) for the determination of nitrate and nitrite in human saliva. Talanta. 2020;219:121183. https:\/\/doi.org\/10.1016\/j.talanta.2020.121183.","journal-title":"Talanta"},{"key":"3706_CR21","doi-asserted-by":"publisher","first-page":"39","DOI":"10.3164\/jcbn.16-70","volume":"60","author":"T Hirayama","year":"2017","unstructured":"Hirayama T, Nagasawa H. Chemical tools for detecting Fe ions. J Clin Biochem Nutr. 2017;60:39\u201348. https:\/\/doi.org\/10.3164\/jcbn.16-70.","journal-title":"J Clin Biochem Nutr"},{"key":"3706_CR22","volume-title":"Separation, preconcentration, and spectrophotometry in inorganic analysis","author":"Z Marczenko","year":"2000","unstructured":"Marczenko Z, Balcerzak M. Separation, preconcentration, and spectrophotometry in inorganic analysis. 1st ed. Amsterdam: Elsevier Science; 2000.","edition":"1"},{"key":"3706_CR23","doi-asserted-by":"publisher","first-page":"688","DOI":"10.1016\/j.talanta.2017.03.017","volume":"167","author":"A Machado","year":"2017","unstructured":"Machado A, Mesquita RBR, Oliveira S, Bordalo AA. Development of a robust, fast screening method for the potentiometric determination of iodide in urine and salt samples. Talanta. 2017;167:688\u201394. https:\/\/doi.org\/10.1016\/j.talanta.2017.03.017.","journal-title":"Talanta"},{"key":"3706_CR24","unstructured":"APHA, AWWA, WEF (1998) Standard Methods for the Examination of Water and Wastewater, Editors: Clesceri LS, Greenberg AE, Eaton AD, 20th ed. Washington, DC, Section 3500-Fe, p.440-447."},{"key":"3706_CR25","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1016\/j.talanta.2014.01.025","volume":"133","author":"IC Santos","year":"2015","unstructured":"Santos IC, Mesquita RBR, Bordalo AA, Rangel AOSS. Iodine speciation in coastal and inland bathing waters and seaweeds extracts using a sequential injection standard addition flow-batch method. Talanta. 2015;133:7\u201314. https:\/\/doi.org\/10.1016\/j.talanta.2014.01.025.","journal-title":"Talanta"},{"key":"3706_CR26","doi-asserted-by":"publisher","first-page":"1699","DOI":"10.1351\/pac199567101699","volume":"67","author":"LA Currie","year":"1995","unstructured":"Currie LA. Nomenclature in evaluation of analytical methods including detection and quantification capabilities (IUPAC Recommendations 1995). Pure Appl Chem. 1995;67:1699\u2013723. https:\/\/doi.org\/10.1351\/pac199567101699.","journal-title":"Pure Appl Chem"}],"container-title":["Analytical and Bioanalytical Chemistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-021-03706-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00216-021-03706-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-021-03706-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,11,27]],"date-time":"2021-11-27T03:04:20Z","timestamp":1637982260000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00216-021-03706-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,15]]},"references-count":26,"journal-issue":{"issue":"30","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["3706"],"URL":"https:\/\/doi.org\/10.1007\/s00216-021-03706-9","relation":{},"ISSN":["1618-2642","1618-2650"],"issn-type":[{"value":"1618-2642","type":"print"},{"value":"1618-2650","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,10,15]]},"assertion":[{"value":"30 June 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 September 2021","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 September 2021","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 October 2021","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The urine samples involved in this work were blind in-house samples, with no identification nor any information required or register, obtained from voluntary participants with informed consent. There was no association with a clinical trial.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}