{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T22:26:10Z","timestamp":1767997570429,"version":"3.49.0"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2020,10,30]],"date-time":"2020-10-30T00:00:00Z","timestamp":1604016000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,10,30]],"date-time":"2020-10-30T00:00:00Z","timestamp":1604016000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2021,5]]},"DOI":"10.1007\/s00330-020-07390-8","type":"journal-article","created":{"date-parts":[[2020,10,30]],"date-time":"2020-10-30T13:02:41Z","timestamp":1604062961000},"page":"3071-3079","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Are lesion features reproducible between 18F-FDG PET\/CT images when acquired on analog or digital PET\/CT scanners?"],"prefix":"10.1007","volume":"31","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4320-8437","authenticated-orcid":false,"given":"Cl\u00e1udia S.","family":"Constantino","sequence":"first","affiliation":[]},{"given":"Francisco P. M.","family":"Oliveira","sequence":"additional","affiliation":[]},{"given":"Mariana","family":"Silva","sequence":"additional","affiliation":[]},{"given":"Carla","family":"Oliveira","sequence":"additional","affiliation":[]},{"given":"Joana C.","family":"Castanheira","sequence":"additional","affiliation":[]},{"given":"\u00c2ngelo","family":"Silva","sequence":"additional","affiliation":[]},{"given":"Sofia C.","family":"Vaz","sequence":"additional","affiliation":[]},{"given":"Pedro","family":"Vieira","sequence":"additional","affiliation":[]},{"given":"Durval C.","family":"Costa","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2020,10,30]]},"reference":[{"key":"7390_CR1","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1007\/s00259-014-2961-x","volume":"42","author":"R Boellaard","year":"2015","unstructured":"Boellaard R, Delgado-Bolton R, Oyen WJG et al (2015) FDG PET\/CT: EANM procedure guidelines for tumour imaging: version 2.0. Eur J Nucl Med Mol Imaging 42:328\u2013354","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"7390_CR2","doi-asserted-by":"publisher","first-page":"122","DOI":"10.2967\/jnumed.108.057307","volume":"50","author":"RL Wahl","year":"2009","unstructured":"Wahl RL, Jacene H, Kasamon Y, Lodge MA (2009) From RECIST to PERCIST: evolving considerations for PET response criteria in solid tumors. J Nucl Med 50:122\u2013150","journal-title":"J Nucl Med"},{"key":"7390_CR3","doi-asserted-by":"publisher","first-page":"1738","DOI":"10.1002\/cncr.22974","volume":"110","author":"EA Kidd","year":"2007","unstructured":"Kidd EA, Siegel BA, Dehdashti F, Grigsby PW (2007) The standardized uptake value for F-18 fluorodeoxyglucose is a sensitive predictive biomarker for cervical cancer treatment response and survival. Cancer 110:1738\u20131744","journal-title":"Cancer"},{"key":"7390_CR4","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1186\/s12885-016-2097-4","volume":"16","author":"N Nakaigawa","year":"2016","unstructured":"Nakaigawa N, Kondo K, Tateishi U et al (2016) FDG PET\/CT as a prognostic biomarker in the era of molecular-targeting therapies: max SUVmax predicts survival of patients with advanced renal cell carcinoma. BMC Cancer 16:67","journal-title":"BMC Cancer"},{"key":"7390_CR5","doi-asserted-by":"crossref","unstructured":"Imsande HM, Davison JM, Truong MT et al (2011) Use of 18F-FDG PET\/CT as a predictive biomarker of outcome in patients with head-and-neck non \u2013 squamous cell carcinoma. AJR Am J Roentgenol 197:976\u2013980","DOI":"10.2214\/AJR.10.4884"},{"key":"7390_CR6","doi-asserted-by":"publisher","first-page":"178","DOI":"10.2967\/jnumed.118.210161","volume":"60","author":"E Woff","year":"2019","unstructured":"Woff E, Hendlisz A, Ameye L et al (2019) Validation of metabolically active tumor volume and total lesion glycolysis as 18F-FDG PET\/CT\u2013derived prognostic biomarkers in chemorefractory metastatic colorectal cancer. J Nucl Med 60:178\u2013184","journal-title":"J Nucl Med"},{"key":"7390_CR7","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1186\/s12885-016-2624-3","volume":"16","author":"T Kitao","year":"2016","unstructured":"Kitao T, Hirata K, Shima K et al (2016) Reproducibility and uptake time dependency of volume-based parameters on FDG-PET for lung cancer. BMC Cancer 16:576","journal-title":"BMC Cancer"},{"key":"7390_CR8","doi-asserted-by":"publisher","first-page":"4006","DOI":"10.1038\/ncomms5006","volume":"5","author":"HJWL Aerts","year":"2014","unstructured":"Aerts HJWL, Velazquez ER, Leijenaar RTH et al (2014) Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach. Nat Commun 5:4006","journal-title":"Nat Commun"},{"key":"7390_CR9","doi-asserted-by":"publisher","first-page":"2638","DOI":"10.1007\/s00259-019-04391-8","volume":"46","author":"A Zwanenburg","year":"2019","unstructured":"Zwanenburg A (2019) Radiomics in nuclear medicine: robustness, reproducibility, standardization, and how to avoid data analysis traps and replication crisis. Eur J Nucl Med Mol Imaging 46:2638\u20132655","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"7390_CR10","doi-asserted-by":"crossref","unstructured":"Dege C, Prescher G, Frach T, et al (2009) The digital silicon photomultiplier - a novel sensor for the detection of scintillation light. In: 2009 IEEE Nuclear Science Symposium Conference Record. pp 2383\u20132386","DOI":"10.1109\/NSSMIC.2009.5402190"},{"key":"7390_CR11","doi-asserted-by":"crossref","unstructured":"Degenhardt C, Rodrigues P, Trindade A, et al (2012) Performance evaluation of a prototype positron emission tomography scanner using digital photon counters (DPC). In: 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record. pp 2820\u20132824","DOI":"10.1109\/NSSMIC.2012.6551643"},{"key":"7390_CR12","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1007\/s00259-009-1297-4","volume":"37","author":"R Boellaard","year":"2010","unstructured":"Boellaard R, Doherty MJO, Weber WA et al (2010) FDG PET and PET\/CT: EANM procedure guidelines for tumour PET imaging: version 1.0. Eur J Nucl Med Mol Imaging 37:181\u2013200","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"7390_CR13","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1186\/s40658-017-0176-5","volume":"4","author":"D Koopman","year":"2017","unstructured":"Koopman D, Groot Koerkamp M, Jager PL et al (2017) Digital PET compliance to EARL accreditation specifications. EJNMMI Phys 4:9","journal-title":"EJNMMI Phys"},{"key":"7390_CR14","doi-asserted-by":"crossref","unstructured":"Koopman D, Jager PL, Slump CH, Knollema S, van Dalen JA (2019) SUV variability in EARL-accredited conventional and digital PET. EJNMMI Res 9:106","DOI":"10.1186\/s13550-019-0569-7"},{"key":"7390_CR15","unstructured":"Philips Medical System (2017) Technical reference guide - Vereos PET\/CT. Cleveland"},{"key":"7390_CR16","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1016\/j.mri.2012.05.001","volume":"30","author":"A Fedorov","year":"2012","unstructured":"Fedorov A, Beichel R, Kalpathy-Cramer J et al (2012) 3D Slicer as an image computing platform for the quantitative imaging network. Magn Reson Imaging 30:1323\u20131341. https:\/\/doi.org\/10.1016\/j.mri.2012.05.001","journal-title":"Magn Reson Imaging"},{"key":"7390_CR17","unstructured":"Constantino C, Oliveira F, Silva M, et al (2019) Segmenta\u00e7\u00e3o autom\u00e1tica de les\u00f5es \u00e1vidas para FDG em PET\/CT baseada numa t\u00e9cnica de clustering bayesiana. In: XVII Congresso Nacional de Medicina Nuclear. p 7"},{"key":"7390_CR18","doi-asserted-by":"publisher","first-page":"523","DOI":"10.2967\/jnumed.116.186353","volume":"58","author":"MA Lodge","year":"2017","unstructured":"Lodge MA (2017) Repeatability of SUV in oncologic 18F-FDG PET. J Nucl Med 58:523\u2013532","journal-title":"J Nucl Med"},{"key":"7390_CR19","doi-asserted-by":"publisher","first-page":"1745","DOI":"10.1007\/s00259-018-4256-0","volume":"46","author":"F Fuentes-Ocampo","year":"2019","unstructured":"Fuentes-Ocampo F, L\u00f3pez-Mora DA, Flotats A et al (2019) Digital vs. analog PET\/CT: intra-subject comparison of the SUVmax in target lesions and reference regions. Eur J Nucl Med Mol Imaging 46:1745\u20131750","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"7390_CR20","doi-asserted-by":"publisher","first-page":"1344","DOI":"10.1007\/s00259-018-3977-4","volume":"45","author":"A Kaalep","year":"2018","unstructured":"Kaalep A, Sera T, Rijnsdorp S et al (2018) Feasibility of state of the art PET\/CT systems performance harmonisation. Eur J Nucl Med Mol Imaging 45:1344\u20131361","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"7390_CR21","doi-asserted-by":"publisher","first-page":"1383","DOI":"10.1007\/s00259-019-4260-z","volume":"46","author":"DA L\u00f3pez-Mora","year":"2019","unstructured":"L\u00f3pez-Mora DA, Flotats A, Fuentes-Ocampo F et al (2019) Comparison of image quality and lesion detection between digital and analog PET\/CT. Eur J Nucl Med Mol Imaging 46:1383\u20131390","journal-title":"Eur J Nucl Med Mol Imaging"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-020-07390-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-020-07390-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-020-07390-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,13]],"date-time":"2021-04-13T10:32:18Z","timestamp":1618309938000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-020-07390-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10,30]]},"references-count":21,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2021,5]]}},"alternative-id":["7390"],"URL":"https:\/\/doi.org\/10.1007\/s00330-020-07390-8","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,10,30]]},"assertion":[{"value":"12 August 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 September 2020","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 October 2020","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 October 2020","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The scientific guarantor of this publication is Durval C. Costa, MD, MSc, PhD, FRCR, head of Nuclear Medicine-Radiopharmacology department at Champalimaud Foundation, Lisbon, Portugal.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare no relationships with any companies, whose products or services may be related to the subject matter of the article.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"One of the authors has significant statistical expertise (Francisco P. M. Oliveira is an experienced statistician; he has a degree in Mathematics, a MSc in Computational Methods, and a PhD in Biomedical Engineering). No complex statistical methods were necessary for this paper.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was obtained from all subjects (patients) in this study.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board approval was obtained.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"\u2022 prospective\u2022 cross-sectional and observational study\u2022 performed at one institution","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}