{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T20:31:20Z","timestamp":1775507480085,"version":"3.50.1"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2009,6,14]],"date-time":"2009-06-14T00:00:00Z","timestamp":1244937600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Eur J Appl Physiol"],"published-print":{"date-parts":[[2009,9]]},"DOI":"10.1007\/s00421-009-1107-5","type":"journal-article","created":{"date-parts":[[2009,6,13]],"date-time":"2009-06-13T01:35:37Z","timestamp":1244856937000},"page":"105-111","source":"Crossref","is-referenced-by-count":113,"title":["Accuracy, reliability, linearity of Accutrend and Lactate Pro versus EBIO plus analyzer"],"prefix":"10.1007","volume":"107","author":[{"given":"Carlo","family":"Baldari","sequence":"first","affiliation":[]},{"given":"Valerio","family":"Bonavolont\u00e0","sequence":"additional","affiliation":[]},{"given":"Gian Pietro","family":"Emerenziani","sequence":"additional","affiliation":[]},{"given":"Maria Chiara","family":"Gallotta","sequence":"additional","affiliation":[]},{"given":"Antonio Jos\u00e9","family":"Silva","sequence":"additional","affiliation":[]},{"given":"Laura","family":"Guidetti","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2009,6,14]]},"reference":[{"key":"1107_CR1","doi-asserted-by":"crossref","first-page":"1798","DOI":"10.1097\/00005768-200010000-00022","volume":"32","author":"C Baldari","year":"2000","unstructured":"Baldari C, Guidetti L (2000) A simple method for individual anaerobic threshold as predictor of max lactate steady state. Med Sci Sports Exerc 32:1798\u20131802. doi: 10.1097\/00005768-200010000-00022","journal-title":"Med Sci Sports Exerc"},{"key":"1107_CR2","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1007\/s00421-004-1203-5","volume":"93","author":"C Baldari","year":"2004","unstructured":"Baldari C, Videira M, Madeira F, Sergio J, Guidetti L (2004) Lactate removal during active recovery related to the individual anaerobic and ventilatory thresholds in soccer players. Eur J Appl Physiol 93:224\u2013230. doi: 10.1007\/s00421-004-1203-5","journal-title":"Eur J Appl Physiol"},{"key":"1107_CR3","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1152\/japplphysiol.00062.2005","volume":"99","author":"R Beneke","year":"2005","unstructured":"Beneke R, H\u00fctler M, Jung M, Leith\u00e4user RM (2005) Modeling the blood lactate kinetics at maximal short-term exercise conditions in children, adolescents, and adults. J Appl Physiol 99:499\u2013504. doi: 10.1152\/japplphysiol.00062.2005","journal-title":"J Appl Physiol"},{"key":"1107_CR4","doi-asserted-by":"crossref","first-page":"2077","DOI":"10.1097\/00005768-200112000-00016","volume":"33","author":"DJ Bentley","year":"2001","unstructured":"Bentley DJ, McNaughton LR, Thompson D, Vleck VE (2001) Peak power output, the lactate threshold, and time trial performance in cyclists. Med Sci Sports Exerc 33:2077\u20132081. doi: 10.1097\/00005768-200112000-00016","journal-title":"Med Sci Sports Exerc"},{"key":"1107_CR5","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1055\/s-2001-17611","volume":"22","author":"D Bishop","year":"2001","unstructured":"Bishop D (2001) Evaluation of the Accusport Lactate Analyser. Int J Sports Med 22:525\u2013530. doi: 10.1055\/s-2001-17611","journal-title":"Int J Sports Med"},{"key":"1107_CR6","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","volume":"1","author":"JM Bland","year":"1986","unstructured":"Bland JM, Altman DG (1986) Statistical methods for assess agreement between two methods of clinical measurement. Lancet 1:307\u2013310","journal-title":"Lancet"},{"key":"1107_CR7","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1016\/S1440-2440(03)80267-0","volume":"6","author":"JD Buckley","year":"2003","unstructured":"Buckley JD, Bourdon PC, Woolford SM (2003) Effect of measuring blood lactate concentrations using different automated lactate analyzers on blood lactate transition thresholds. J Sci Med Sport 6:408\u2013421. doi: 10.1016\/S1440-2440(03)80267-0","journal-title":"J Sci Med Sport"},{"key":"1107_CR8","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1016\/j.cbpb.2004.12.002","volume":"140","author":"JF Carvalho","year":"2005","unstructured":"Carvalho JF, Masako Masuda O, Pompeu AMS (2005) Methods for diagnosis and control of aerobic training in rats based on lactate threshold. Comp Biochem Physiol A 140:409\u2013413. doi: 10.1016\/j.cbpb.2004.12.002","journal-title":"Comp Biochem Physiol A"},{"key":"1107_CR9","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1055\/s-2007-971904","volume":"19","author":"JW Fell","year":"1998","unstructured":"Fell JW, Rayfield JP, Gulbin PT, Gaffney PT (1998) Evaluation of the Accusport Lactate Analyser. Int J Sports Med 19:199\u2013204. doi: 10.1055\/s-2007-971904","journal-title":"Int J Sports Med"},{"key":"1107_CR10","doi-asserted-by":"crossref","first-page":"558","DOI":"10.1177\/193229680700100414","volume":"1","author":"ML Goodwin","year":"2007","unstructured":"Goodwin ML, Harris JE, Hernandez A, Gladden LB (2007) Blood lactate measurements and analysis during exercise: a guide for clinicians. J Diabetes Sci Technol 1:558\u2013569","journal-title":"J Diabetes Sci Technol"},{"key":"1107_CR11","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1055\/s-2008-1025824","volume":"6","author":"H Heck","year":"1985","unstructured":"Heck H, Mader A, Hess G, M\u00fccke S, M\u00fcller R, Hollmann W (1985) Justification of the 4-mmol\/l lactate threshold. Int J Sports Med 6:117\u2013130. doi: 10.1055\/s-2008-1025824","journal-title":"Int J Sports Med"},{"key":"1107_CR12","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1055\/s-2002-20133","volume":"23","author":"LR Mc Naughton","year":"2002","unstructured":"Mc Naughton LR, Thompson D, Philips G, Backx K, Crickmore L (2002) A comparison of the Lactate Pro, Accusport, Analox GM7 and Kodak Ektachem Lactate Analysers in normal, hot and humid conditions. Int J Sports Med 23:130\u2013135. doi: 10.1055\/s-2002-20133","journal-title":"Int J Sports Med"},{"key":"1107_CR13","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1080\/003655100750019279","volume":"60","author":"JI Medb\u00f8","year":"2000","unstructured":"Medb\u00f8 JI, Mamen A, Holt Olsen O, Evertsen F (2000) Examination of four different instruments for measuring blood lactate concentration. Scand J Clin Lab Invest 60:367\u2013380. doi: 10.1080\/003655100750019279","journal-title":"Scand J Clin Lab Invest"},{"key":"1107_CR14","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1515\/jpme.1998.26.2.83","volume":"26","author":"L Nordstrom","year":"1998","unstructured":"Nordstrom L, Chua S, Roy A, Arulkumaran S (1998) Quality assessment of two lactate test strip methods suitable for obstetric use. J Perinat Med 26:83\u201388","journal-title":"J Perinat Med"},{"key":"1107_CR15","first-page":"263","volume":"108","author":"L Nordstrom","year":"2001","unstructured":"Nordstrom L, Achanna S, Naka K, Arulkumaran S (2001) Fetal and maternal lactate increase during active second stage of labour. BJOG 108:263\u2013268","journal-title":"BJOG"},{"key":"1107_CR16","doi-asserted-by":"crossref","first-page":"670","DOI":"10.1097\/00005768-199905000-00008","volume":"31","author":"T Oosthuyse","year":"1999","unstructured":"Oosthuyse T, Carter RN (1999) Plasma lactate decline during passive recovery from high-intensity exercise. Med Sci Sports Exerc 31:670\u2013674. doi: 10.1097\/00005768-199905000-00008","journal-title":"Med Sci Sports Exerc"},{"key":"1107_CR17","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/S1440-2440(01)80014-1","volume":"4","author":"H Pinnington","year":"2001","unstructured":"Pinnington H, Dawson B (2001) Examination of the validity and reliability of the Accusport blood lactate analyser. J Sci Med Sport 4:129\u2013138. doi: 10.1016\/S1440-2440(01)80014-1","journal-title":"J Sci Med Sport"},{"key":"1107_CR18","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1007\/s004210050659","volume":"82","author":"DB Pyne","year":"2000","unstructured":"Pyne DB, Martin DT, Logan A (2000) Evaluation of the Lactate Pro blood lactate analyser. Eur J Appl Physiol 82:112\u2013116. doi: 10.1007\/s004210050659","journal-title":"Eur J Appl Physiol"},{"key":"1107_CR19","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1097\/00005768-200102000-00019","volume":"33","author":"DB Pyne","year":"2001","unstructured":"Pyne DB, Lee H, Swanwick KM (2001) Monitoring the lactate threshold in world-ranked swimmers. Med Sci Sports Exerc 33:291\u2013297. doi: 10.1097\/00005768-200102000-00019","journal-title":"Med Sci Sports Exerc"},{"key":"1107_CR20","first-page":"657","volume":"26","author":"KA Someren Van","year":"2005","unstructured":"Van Someren KA, Howatson G, Nunan D, Thatcher R, Shave R (2005) Comparison of the Lactate Pro and Analox GM7 blood lactate analysers. J Sports Med 26:657\u2013661. doi: 10.1055\/s-2004-830337","journal-title":"J Sports Med"},{"key":"1107_CR21","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1097\/00006254-199901000-00023","volume":"54","author":"M Westgren","year":"1999","unstructured":"Westgren M, Kublickas M, Kruger K (1999) Role of lactate measurements during labor. Obstet Gynecol Surv 54:43\u201348. doi: 10.1097\/00006254-199901000-00023","journal-title":"Obstet Gynecol Surv"}],"container-title":["European Journal of Applied Physiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00421-009-1107-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00421-009-1107-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00421-009-1107-5","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,28]],"date-time":"2019-05-28T16:14:58Z","timestamp":1559060098000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00421-009-1107-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,6,14]]},"references-count":21,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2009,9]]}},"alternative-id":["1107"],"URL":"https:\/\/doi.org\/10.1007\/s00421-009-1107-5","relation":{},"ISSN":["1439-6319","1439-6327"],"issn-type":[{"value":"1439-6319","type":"print"},{"value":"1439-6327","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,6,14]]}}}