{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,16]],"date-time":"2026-03-16T16:31:48Z","timestamp":1773678708688,"version":"3.50.1"},"reference-count":83,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2021,2,22]],"date-time":"2021-02-22T00:00:00Z","timestamp":1613952000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,2,22]],"date-time":"2021-02-22T00:00:00Z","timestamp":1613952000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100005856","name":"Faculdade de Ci\u00eancias e Tecnologia, Universidade Nova de Lisboa","doi-asserted-by":"publisher","award":["UID\/EEA\/04436\/2013"],"award-info":[{"award-number":["UID\/EEA\/04436\/2013"]}],"id":[{"id":"10.13039\/501100005856","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100005856","name":"Faculdade de Ci\u00eancias e Tecnologia, Universidade Nova de Lisboa","doi-asserted-by":"publisher","award":["NORTE-01-0145-FEDER-000018 \u2013 HAMaBICo"],"award-info":[{"award-number":["NORTE-01-0145-FEDER-000018 \u2013 HAMaBICo"]}],"id":[{"id":"10.13039\/501100005856","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Clin Oral Invest"],"published-print":{"date-parts":[[2021,4]]},"DOI":"10.1007\/s00784-021-03785-z","type":"journal-article","created":{"date-parts":[[2021,2,22]],"date-time":"2021-02-22T05:03:11Z","timestamp":1613970191000},"page":"1627-1640","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":72,"title":["Cytotoxic effects of submicron- and nano-scale titanium debris released from dental implants: an integrative review"],"prefix":"10.1007","volume":"25","author":[{"given":"Redouane","family":"Messous","sequence":"first","affiliation":[]},{"given":"Bruno","family":"Henriques","sequence":"additional","affiliation":[]},{"given":"Hassan","family":"Bousbaa","sequence":"additional","affiliation":[]},{"given":"Filipe S.","family":"Silva","sequence":"additional","affiliation":[]},{"given":"Wim","family":"Teughels","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7999-4009","authenticated-orcid":false,"given":"J\u00falio C. M.","family":"Souza","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2021,2,22]]},"reference":[{"key":"3785_CR1","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1016\/j.ijom.2014.10.023","volume":"44","author":"V Moraschini","year":"2015","unstructured":"Moraschini V, Poubel LADC, Ferreira VF, Barboza EDSP (2015) Evaluation of survival and success rates of dental implants reported in longitudinal studies with a follow-up period of at least 10 years: a systematic review. Int J Oral Maxillofac Surg 44:377\u2013388. https:\/\/doi.org\/10.1016\/j.ijom.2014.10.023","journal-title":"Int J Oral Maxillofac Surg"},{"key":"3785_CR2","doi-asserted-by":"publisher","first-page":"781","DOI":"10.1111\/cid.12017","volume":"14","author":"T Albrektsson","year":"2012","unstructured":"Albrektsson T, Buser D, Chen ST, Cochran D, DeBruyn H, Jemt T, Koka S, Nevins M, Sennerby L, Simion M, Taylor TD, Wennerberg A (2012) Statements from the Estepona consensus meeting on peri-implantitis, February 2\u20134, 2012. Clin Implant Dent Relat Res 14:781\u2013782","journal-title":"Clin Implant Dent Relat Res"},{"key":"3785_CR3","doi-asserted-by":"publisher","first-page":"S158","DOI":"10.1111\/jcpe.12334","volume":"42","author":"J Derks","year":"2015","unstructured":"Derks J, Tomasi C (2015) Peri-implant health and disease. A systematic review of current epidemiology. J Clin Periodontol 42:S158\u2013S171. https:\/\/doi.org\/10.1111\/jcpe.12334","journal-title":"J Clin Periodontol"},{"key":"3785_CR4","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1111\/clr.13416","volume":"30","author":"K Kordbacheh Changi","year":"2019","unstructured":"Kordbacheh Changi K, Finkelstein J, Papapanou PN (2019) Peri-implantitis prevalence, incidence rate, and risk factors: a study of electronic health records at a U.S. dental school. Clin Oral Implants Res 30:306\u2013314. https:\/\/doi.org\/10.1111\/clr.13416","journal-title":"Clin Oral Implants Res"},{"key":"3785_CR5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jdent.2017.04.011","volume":"62","author":"CT Lee","year":"2017","unstructured":"Lee CT, Huang YW, Zhu L, Weltman R (2017) Prevalences of peri-implantitis and peri-implant mucositis: systematic review and meta-analysis. J Dent 62:1\u201312. https:\/\/doi.org\/10.1016\/j.jdent.2017.04.011","journal-title":"J Dent"},{"key":"3785_CR6","doi-asserted-by":"publisher","first-page":"1805","DOI":"10.1007\/s00784-017-2276-y","volume":"22","author":"M Rakic","year":"2018","unstructured":"Rakic M, Galindo-Moreno P, Monje A, Radovanovic S, Wang HL, Cochran D, Sculean A, Canullo L (2018) How frequent does peri-implantitis occur? A systematic review and meta-analysis. Clin Oral Investig 22:1805\u20131816. https:\/\/doi.org\/10.1007\/s00784-017-2276-y","journal-title":"Clin Oral Investig"},{"key":"3785_CR7","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1111\/j.1600-0501.2012.02500.x","volume":"24","author":"K Patel","year":"2013","unstructured":"Patel K, Mardas N, Donos N (2013) Radiographic and clinical outcomes of implants placed in ridge preserved sites: a 12-month post-loading follow-up. Clin Oral Implants Res 24:599\u2013605. https:\/\/doi.org\/10.1111\/j.1600-0501.2012.02500.x","journal-title":"Clin Oral Implants Res"},{"key":"3785_CR8","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1097\/ID.0000000000000836","volume":"28","author":"W Zhou","year":"2019","unstructured":"Zhou W, Tangl S, Reich KM, Kirchweger F, Liu Z, Zechner W, Christian Ulm, Rausch-Fan X (2019) The influence of type 2 diabetes mellitus on the osseointegration of titanium implants with different surface modifications\u2014a histomorphometric study in high-fat diet\/low-dose streptozotocin-treated rats. Implant Dent 28:11\u201319. https:\/\/doi.org\/10.1097\/ID.0000000000000836","journal-title":"Implant Dent"},{"key":"3785_CR9","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1177\/0022034517740560","volume":"97","author":"T Fretwurst","year":"2018","unstructured":"Fretwurst T, Nelson K, Tarnow DP, Wang HL, Giannobile WV (2018) Is metal particle release associated with peri-implant bone destruction? An emerging concept. J Dent Res 97:259\u2013265. https:\/\/doi.org\/10.1177\/0022034517740560","journal-title":"J Dent Res"},{"key":"3785_CR10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1111\/jre.12479","volume":"53","author":"M Noronha Oliveira","year":"2018","unstructured":"Noronha Oliveira M, Schunemann WVH, Mathew MT, Henriques B, Magini RS, Teughels W, Souza JCM (2018) Can degradation products released from dental implants affect peri-implant tissues? J Periodontal Res 53:1\u201311. https:\/\/doi.org\/10.1111\/jre.12479","journal-title":"J Periodontal Res"},{"key":"3785_CR11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1111\/jre.12469","volume":"52","author":"K Apaza-Bedoya","year":"2017","unstructured":"Apaza-Bedoya K, Tarce M, Benfatti CAMAM et al (2017) Synergistic interactions between corrosion and wear at titanium-based dental implant connections: a scoping review. J Periodontal Res 52:1\u20139. https:\/\/doi.org\/10.1111\/jre.12469","journal-title":"J Periodontal Res"},{"key":"3785_CR12","doi-asserted-by":"publisher","unstructured":"Souza JCM, Apaza-Bedoya K, Benfatti CAM et al (2020) A comprehensive review on the corrosion pathways of titanium dental implants and their biological adverse effects. Met. 10(9):1272.\u00a0https:\/\/doi.org\/10.3390\/met10091272","DOI":"10.3390\/met10091272"},{"key":"3785_CR13","doi-asserted-by":"publisher","unstructured":"Bressan E, Ferroni L, Gardin C, Bellin G, Sbricoli L, Sivolella S, Brunello G, Schwartz-Arad D, Mijiritsky E, Penarrocha M, Penarrocha D, Taccioli C, Tatullo M, Piattelli A, Zavan B (2019) Metal nanoparticles released from dental implant surfaces: potential contribution to chronic inflammation and peri-implant bone loss. Materials (Basel) 12. https:\/\/doi.org\/10.3390\/ma12122036","DOI":"10.3390\/ma12122036"},{"key":"3785_CR14","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1016\/j.sdentj.2019.09.008","volume":"32","author":"Z Berryman","year":"2019","unstructured":"Berryman Z, Bridger L, Hussaini HM, Rich AM, Atieh M, Tawse-Smith A (2019) Titanium particles: an emerging risk factor for peri-implant bone loss. Saudi Dent J 32:283\u2013292. https:\/\/doi.org\/10.1016\/j.sdentj.2019.09.008","journal-title":"Saudi Dent J"},{"key":"3785_CR15","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1902\/jop.2014.140363","volume":"86","author":"TG Wilson","year":"2015","unstructured":"Wilson TG, Valderrama P, Burbano M et al (2015) Foreign bodies associated with peri-implantitis human biopsies. J Periodontol 86:9\u201315. https:\/\/doi.org\/10.1902\/jop.2014.140363","journal-title":"J Periodontol"},{"key":"3785_CR16","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1563\/AAID-JOI-D-11-00032","volume":"40","author":"KX Michalakis","year":"2014","unstructured":"Michalakis KX, Lino P, Muftu S et al (2014) The effect of different implant\u2013abutment connections on screw joint stability. J Oral Implantol 40:146\u2013152. https:\/\/doi.org\/10.1563\/AAID-JOI-D-11-00032","journal-title":"J Oral Implantol"},{"key":"3785_CR17","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1007\/s10856-017-5879-6","volume":"28","author":"AM Prado","year":"2017","unstructured":"Prado AM, Pereira J, Silva FS, Henriques B, Nascimento RM, Benfatti CAM, L\u00f3pez-L\u00f3pez J, Souza JCM (2017) Wear of Morse taper and external hexagon implant joints after abutment removal. J Mater Sci Mater Med 28:65. https:\/\/doi.org\/10.1007\/s10856-017-5879-6","journal-title":"J Mater Sci Mater Med"},{"key":"3785_CR18","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.1111\/clr.13372","volume":"29","author":"F Su\u00e1rez-L\u00f3pez Del Amo","year":"2018","unstructured":"Su\u00e1rez-L\u00f3pez Del Amo F, Garaicoa-Pazmi\u00f1o C, Fretwurst T et al (2018) Dental implants-associated release of titanium particles: a systematic review. Clin Oral Implants Res 29:1085\u20131100. https:\/\/doi.org\/10.1111\/clr.13372","journal-title":"Clin Oral Implants Res"},{"key":"3785_CR19","doi-asserted-by":"publisher","unstructured":"Happe A, Sielker S, Hanisch M, Jung S (2019) The biologic effect of particulate titanium contaminants of dental implants on human osteoblasts and gingival fibroblasts. Int J Oral Maxillofac Implants 34:673\u2013680. https:\/\/doi.org\/10.11607\/jomi.6929","DOI":"10.11607\/jomi.6929"},{"key":"3785_CR20","doi-asserted-by":"publisher","unstructured":"Yang F, Tang J, Dai K, Huang Y (2019) Metallic wear debris collected from patients induces apoptosis in rat primary osteoblasts via reactive oxygen species-mediated mitochondrial dysfunction and endoplasmic reticulum stress. Mol Med Rep 19:1629\u20131637. https:\/\/doi.org\/10.3892\/mmr.2019.9825","DOI":"10.3892\/mmr.2019.9825"},{"key":"3785_CR21","doi-asserted-by":"publisher","unstructured":"Su\u00e1rez-L\u00f3pez Del Amo F, Rudek I, Wagner VP et al Titanium activates the DNA damage response pathway in oral epithelial cells: a pilot study. Int J Oral Maxillofac Implants 32:1413\u20131420. https:\/\/doi.org\/10.11607\/jomi.6077","DOI":"10.11607\/jomi.6077"},{"key":"3785_CR22","doi-asserted-by":"publisher","unstructured":"Dodo CG, Meirelles L, Aviles-Reyes A, Ruiz KGS, Abranches J, Cury AADB (2017) Pro-inflammatory analysis of macrophages in contact with titanium particles and porphyromonas gingivalis. Braz Dent J 28:428\u2013434. https:\/\/doi.org\/10.1590\/0103-6440201701382","DOI":"10.1590\/0103-6440201701382"},{"key":"3785_CR23","doi-asserted-by":"publisher","unstructured":"Pettersson M, Kelk P, Belibasakis GN, Bylund D, Molin Thor\u00e9n M, Johansson A (2017) Titanium ions form particles that activate and execute interleukin-1$\u03b2$ release from lipopolysaccharide-primed macrophages. J Periodontal Res 52:21\u201332. https:\/\/doi.org\/10.1111\/jre.12364","DOI":"10.1111\/jre.12364"},{"key":"3785_CR24","doi-asserted-by":"publisher","unstructured":"He X, Hartlieb E, Rothmund L, Waschke J, Wu X, van Landuyt KL, Milz S, Michalke B, Hickel R, Reichl FX, H\u00f6gg C (2015) Intracellular uptake and toxicity of three different titanium particles. Dent Mater 31:734\u2013744. https:\/\/doi.org\/10.1016\/j.dental.2015.03.017","DOI":"10.1016\/j.dental.2015.03.017"},{"key":"3785_CR25","doi-asserted-by":"publisher","unstructured":"Rutkunas V, Bukelskiene V, Sabaliauskas V, Balciunas E, Malinauskas M, Baltriukiene D (2015) Assessment of human gingival fibroblast interaction with dental implant abutment materials. J Mater Sci Mater Med 26. https:\/\/doi.org\/10.1007\/s10856-015-5481-8","DOI":"10.1007\/s10856-015-5481-8"},{"key":"3785_CR26","doi-asserted-by":"publisher","unstructured":"Vall\u00e8s G, Gonz\u00e1lez-Melendi P, Salda\u00f1a L et al (2008) Rutile and titanium particles differentially affect the production of osteoblastic local factors. J Biomed Mater Res - Part A 84:324\u2013336. https:\/\/doi.org\/10.1002\/jbm.a.31315","DOI":"10.1002\/jbm.a.31315"},{"key":"3785_CR27","doi-asserted-by":"publisher","unstructured":"Valles G, Gonzalez-Melendi P, Gonzalez-Carrasco JL et al (2006) Differential inflammatory macrophage response to rutile and titanium particles. Biomaterials 27:5199\u20135211. https:\/\/doi.org\/10.1016\/j.biomaterials.2006.05.045","DOI":"10.1016\/j.biomaterials.2006.05.045"},{"key":"3785_CR28","doi-asserted-by":"publisher","unstructured":"Wang ML, Tuli R, Manner PA, Sharkey PF, Hall DJ, Tuan RS (2003) Direct and indirect induction of apoptosis in human mesenchymal stem cells in response to titanium particles. J Orthop Res 21:697\u2013707. https:\/\/doi.org\/10.1016\/S0736-0266(02)00241-3","DOI":"10.1016\/S0736-0266(02)00241-3"},{"key":"3785_CR29","doi-asserted-by":"publisher","unstructured":"Kraft CN, Diedrich O, Burian B, Schmitt O, Wimmer MA (2003) Microvascular response of striated muscle to metal debris. A comparative in vivo study with titanium and stainless steel. J Bone Joint Surg (Br) 85:133\u2013141. https:\/\/doi.org\/10.1302\/0301-620X.85B1.12749","DOI":"10.1302\/0301-620X.85B1.12749"},{"key":"3785_CR30","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1007\/s10006-015-0494-5","volume":"19","author":"MC Goiato","year":"2015","unstructured":"Goiato MC, Pellizzer EP, da Silva EVF, Bonatto LR, dos Santos DM (2015) Is the internal connection more efficient than external connection in mechanical, biological, and esthetical point of views? A systematic review. Oral Maxillofac Surg 19:229\u2013242. https:\/\/doi.org\/10.1007\/s10006-015-0494-5","journal-title":"Oral Maxillofac Surg"},{"key":"3785_CR31","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1016\/j.jdent.2012.02.009","volume":"40","author":"S Saidin","year":"2012","unstructured":"Saidin S, Abdul Kadir MR, Sulaiman E, Abu Kasim NH (2012) Effects of different implant-abutment connections on micromotion and stress distribution: prediction of microgap formation. J Dent 40:467\u2013474. https:\/\/doi.org\/10.1016\/j.jdent.2012.02.009","journal-title":"J Dent"},{"key":"3785_CR32","doi-asserted-by":"publisher","first-page":"148","DOI":"10.4103\/1305-7456.175677","volume":"10","author":"JP Macedo","year":"2016","unstructured":"Macedo JP, Pereira J, Vahey BR et al (2016) Morse taper dental implants and platform switching: the new paradigm in oral implantology. Eur J Dent 10:148\u2013154. https:\/\/doi.org\/10.4103\/1305-7456.175677","journal-title":"Eur J Dent"},{"key":"3785_CR33","doi-asserted-by":"publisher","unstructured":"Souza JCM, Henriques M, Teughels W, Ponthiaux P, Celis JP, Rocha LA (2015) Wear and corrosion interactions on titanium in oral environment: literature review. J Bio- Tribo-Corrosion 1. https:\/\/doi.org\/10.1007\/s40735-015-0013-0","DOI":"10.1007\/s40735-015-0013-0"},{"key":"3785_CR34","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1016\/S0921-5093(97)00806-X","volume":"243","author":"M Niinomi","year":"1998","unstructured":"Niinomi M (1998) Mechanical properties of biomedical titanium alloys. Mater Sci Eng A 243:231\u2013236. https:\/\/doi.org\/10.1016\/S0921-5093(97)00806-X","journal-title":"Mater Sci Eng A"},{"key":"3785_CR35","doi-asserted-by":"publisher","first-page":"960","DOI":"10.1016\/j.msec.2016.01.032","volume":"62","author":"FA Shah","year":"2016","unstructured":"Shah FA, Trobos M, Thomsen P, Palmquist A (2016) Commercially pure titanium (cp-Ti) versus titanium alloy (Ti6Al4V) materials as bone anchored implants \u2013 is one truly better than the other? Mater Sci Eng C 62:960\u2013966. https:\/\/doi.org\/10.1016\/j.msec.2016.01.032","journal-title":"Mater Sci Eng C"},{"key":"3785_CR36","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1016\/j.matchar.2006.03.020","volume":"58","author":"NK Kuromoto","year":"2007","unstructured":"Kuromoto NK, Sim\u00e3o RA, Soares GA (2007) Titanium oxide films produced on commercially pure titanium by anodic oxidation with different voltages. Mater Charact 58:114\u2013121. https:\/\/doi.org\/10.1016\/j.matchar.2006.03.020","journal-title":"Mater Charact"},{"key":"3785_CR37","doi-asserted-by":"publisher","first-page":"988","DOI":"10.1002\/jbm.b.33079","volume":"102","author":"L Lara Rodriguez","year":"2014","unstructured":"Lara Rodriguez L, Sundaram PA, Rosim-Fachini E, Padovani AM, Diffoot-Carlo N (2014) Plasma electrolytic oxidation coatings on \u03b3tiAl alloy for potential biomedical applications. J Biomed Mater Res - Part B Appl Biomater 102:988\u20131001. https:\/\/doi.org\/10.1002\/jbm.b.33079","journal-title":"J Biomed Mater Res - Part B Appl Biomater"},{"key":"3785_CR38","doi-asserted-by":"publisher","unstructured":"Noumbissi S, Scarano A, Gupta S (2019) A literature review study on atomic ions dissolution of titanium and its alloys in implant dentistry. Mater (Basel, Switzerland) 12. https:\/\/doi.org\/10.3390\/ma12030368","DOI":"10.3390\/ma12030368"},{"key":"3785_CR39","doi-asserted-by":"publisher","first-page":"3161","DOI":"10.1098\/rsif.2012.0438","volume":"9","author":"O Addison","year":"2012","unstructured":"Addison O, Davenport AJ, Newport RJ, Kalra S, Monir M, Mosselmans JFW, Proops D, Martin RA (2012) Do \u201cpassive\u201d medical titanium surfaces deteriorate in service in the absence of wear? J R Soc Interface 9:3161\u20133164. https:\/\/doi.org\/10.1098\/rsif.2012.0438","journal-title":"J R Soc Interface"},{"key":"3785_CR40","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1016\/j.msec.2014.11.055","volume":"47","author":"JCM Souza","year":"2015","unstructured":"Souza JCM, Barbosa SL, Ariza EA, Henriques M, Teughels W, Ponthiaux P, Celis JP, Rocha LA (2015) How do titanium and Ti6Al4V corrode in fluoridated medium as found in the oral cavity? An in vitro study. Mater Sci Eng C 47:384\u2013393. https:\/\/doi.org\/10.1016\/j.msec.2014.11.055","journal-title":"Mater Sci Eng C"},{"key":"3785_CR41","doi-asserted-by":"publisher","first-page":"2747","DOI":"10.1007\/s00216-011-5232-8","volume":"401","author":"Y Nuevo-Ord\u00f3\u00f1ez","year":"2011","unstructured":"Nuevo-Ord\u00f3\u00f1ez Y, Montes-Bay\u00f3n M, Blanco-Gonz\u00e1lez E, Paz-Aparicio J, Raimundez JD, Tejerina JM, Pe\u00f1a MA, Sanz-Medel A (2011) Titanium release in serum of patients with different bone fixation implants and its interaction with serum biomolecules at physiological levels. Anal Bioanal Chem 401:2747\u20132754. https:\/\/doi.org\/10.1007\/s00216-011-5232-8","journal-title":"Anal Bioanal Chem"},{"key":"3785_CR42","doi-asserted-by":"publisher","first-page":"23615","DOI":"10.1038\/srep23615","volume":"6","author":"AR Ribeiro","year":"2016","unstructured":"Ribeiro AR, Gemini-Piperni S, Travassos R, Lemgruber L, C. Silva R, Rossi AL, Farina M, Anselme K, Shokuhfar T, Shahbazian-Yassar R, Borojevic R, Rocha LA, Werckmann J, Granjeiro JM (2016) Trojan-like internalization of anatase titanium dioxide nanoparticles by human osteoblast cells. Sci Rep 6:23615. https:\/\/doi.org\/10.1038\/srep23615","journal-title":"Sci Rep"},{"key":"3785_CR43","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1016\/S1470-2045(06)70651-9","volume":"7","author":"R Baan","year":"2006","unstructured":"Baan R, Straif K, Grosse Y, Secretan B, el Ghissassi F, Cogliano V (2006) Carcinogenicity of carbon black, titanium dioxide, and talc. Lancet Oncol 7:295\u2013296. https:\/\/doi.org\/10.1016\/S1470-2045(06)70651-9","journal-title":"Lancet Oncol"},{"key":"3785_CR44","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1016\/j.aquatox.2015.11.030","volume":"170","author":"F Girardello","year":"2016","unstructured":"Girardello F, Cust\u00f3dio Leite C, Vianna Villela I, da Silva Machado M, Luiz Mendes Juchem A, Roesch-Ely M, Neves Fernandes A, Salvador M, Antonio P\u00eagas Henriques J (2016) Titanium dioxide nanoparticles induce genotoxicity but not mutagenicity in golden mussel Limnoperna fortunei. Aquat Toxicol 170:223\u2013228. https:\/\/doi.org\/10.1016\/j.aquatox.2015.11.030","journal-title":"Aquat Toxicol"},{"key":"3785_CR45","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1016\/j.fct.2017.04.005","volume":"105","author":"AK Jain","year":"2017","unstructured":"Jain AK, Senapati VA, Singh D, Dubey K, Maurya R, Pandey AK (2017) Impact of anatase titanium dioxide nanoparticles on mutagenic and genotoxic response in Chinese hamster lung fibroblast cells (V-79): the role of cellular uptake. Food Chem Toxicol 105:127\u2013139. https:\/\/doi.org\/10.1016\/j.fct.2017.04.005","journal-title":"Food Chem Toxicol"},{"key":"3785_CR46","doi-asserted-by":"publisher","unstructured":"Boisen AMZ, Shipley T, Jackson P et al (2012) NanoTIO2 (UV-titan) does not induce ESTR mutations in the germline of prenatally exposed female mice. Part Fibre Toxicol 9(19). https:\/\/doi.org\/10.1186\/1743-8977-9-19","DOI":"10.1186\/1743-8977-9-19"},{"key":"3785_CR47","doi-asserted-by":"publisher","first-page":"60","DOI":"10.17305\/BJBMS.2018.3674","volume":"19","author":"TP Zdravkovi\u0107","year":"2019","unstructured":"Zdravkovi\u0107 TP, Zdravkovi\u0107 B, Lunder M, Ferk P (2019) The effect of micro-sized titanium dioxide on WM-266-4 metastatic melanoma cell line. Bosn J Basic Med Sci 19:60\u201366. https:\/\/doi.org\/10.17305\/BJBMS.2018.3674","journal-title":"Bosn J Basic Med Sci"},{"key":"3785_CR48","doi-asserted-by":"publisher","first-page":"792","DOI":"10.1563\/AAID-JOI-D-11-00045","volume":"38","author":"NB Bhatavadekar","year":"2012","unstructured":"Bhatavadekar NB (2012) Squamous cell carcinoma in association with dental implants: an assessment of previously hypothesized carcinogenic mechanisms and a case report. J Oral Implantol 38:792\u2013798","journal-title":"J Oral Implantol"},{"key":"3785_CR49","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1111\/cid.12566","volume":"20","author":"SE Wheelis","year":"2018","unstructured":"Wheelis SE, Wilson TG, Valderrama P, Rodrigues DC (2018) Surface characterization of titanium implant healing abutments before and after placement. Clin Implant Dent Relat Res 20:180\u2013190. https:\/\/doi.org\/10.1111\/cid.12566","journal-title":"Clin Implant Dent Relat Res"},{"key":"3785_CR50","doi-asserted-by":"publisher","first-page":"1269","DOI":"10.1902\/jop.2004.75.9.1269","volume":"75","author":"S Sato","year":"2004","unstructured":"Sato S, Kishida M, Ito K (2004) The comparative effect of ultrasonic scalers on titanium surfaces: an in vitro study. J Periodontol 75:1269\u20131273. https:\/\/doi.org\/10.1902\/jop.2004.75.9.1269","journal-title":"J Periodontol"},{"key":"3785_CR51","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1111\/j.1708-8208.2004.tb00038.x","volume":"6","author":"A Khraisat","year":"2004","unstructured":"Khraisat A, Abu-hammad O, Al-kayed AM (2004) Stability of the implant\/abutment joint in a single-tooth external-hexagon implant system: clinical and mechanical review. Clin Implant Dent Relat Res 6:222\u2013229","journal-title":"Clin Implant Dent Relat Res"},{"key":"3785_CR52","doi-asserted-by":"publisher","first-page":"99","DOI":"10.11607\/jomi.2014suppl.g2.2","volume":"29","author":"A Zembic","year":"2014","unstructured":"Zembic A, Kim S, Zwahlen M, Kelly JR (2014) Systematic review of the survival rate and incidence of biologic, technical, and esthetic complications of single implant abutments supporting fixed prostheses. Int J Oral Maxillofac Implants 29:99\u2013116. https:\/\/doi.org\/10.11607\/jomi.2014suppl.g2.2","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"Suppl 1","key":"3785_CR53","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1034\/j.1600-0501.2000.011S1156.x","volume":"11","author":"MS Schwarz","year":"2000","unstructured":"Schwarz MS (2000) Mechanical complications of dental implants. Clin Oral Implants Res 11(Suppl 1):156\u2013158. https:\/\/doi.org\/10.1034\/j.1600-0501.2000.011S1156.x","journal-title":"Clin Oral Implants Res"},{"key":"3785_CR54","doi-asserted-by":"publisher","unstructured":"Noronha Oliveira M, Schunemann WVH, Mathew MT et al (2018) Can degradation products released from dental implants affect peri-implant tissues? J Periodontal Res 53. https:\/\/doi.org\/10.1111\/jre.12479","DOI":"10.1111\/jre.12479"},{"key":"3785_CR55","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.jmbbm.2012.05.019","volume":"15","author":"L Bolzoni","year":"2012","unstructured":"Bolzoni L, Esteban PG, Ruiz-Navas EM, Gordo E (2012) Mechanical behaviour of pressed and sintered titanium alloys obtained from master alloy addition powders. J Mech Behav Biomed Mater 15:33\u201345. https:\/\/doi.org\/10.1016\/j.jmbbm.2012.05.019","journal-title":"J Mech Behav Biomed Mater"},{"key":"3785_CR56","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1080\/08927011003767985","volume":"26","author":"JCM Souza","year":"2010","unstructured":"Souza JCM, Henriques M, Oliveira R, Teughels W, Celis JP, Rocha LA (2010) Do oral biofilms influence the wear and corrosion behavior of titanium? Biofouling 26:471\u2013478. https:\/\/doi.org\/10.1080\/08927011003767985","journal-title":"Biofouling"},{"key":"3785_CR57","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1016\/j.wear.2012.05.030","volume":"292\u2013293","author":"JCM Souza","year":"2012","unstructured":"Souza JCM, Barbosa SL, Ariza E, Celis JP, Rocha LA (2012) Simultaneous degradation by corrosion and wear of titanium in artificial saliva containing fluorides. Wear 292\u2013293:82\u201388. https:\/\/doi.org\/10.1016\/j.wear.2012.05.030","journal-title":"Wear"},{"key":"3785_CR58","doi-asserted-by":"publisher","first-page":"1428","DOI":"10.1016\/j.dental.2006.11.030","volume":"23","author":"C Manaranche","year":"2007","unstructured":"Manaranche C, Hornberger H (2007) A proposal for the classification of dental alloys according to their resistance to corrosion. Dent Mater 23:1428\u20131437. https:\/\/doi.org\/10.1016\/j.dental.2006.11.030","journal-title":"Dent Mater"},{"key":"3785_CR59","doi-asserted-by":"crossref","unstructured":"Kirmanidou Y, Sidira M, Drosou ME et al (2016) New Ti-alloys and surface modifications to improve the mechanical properties and the biological response to orthopedic and dental implants: a review. Biomed Res Int 2908570. 10.1155\/2016\/2908570","DOI":"10.1155\/2016\/2908570"},{"key":"3785_CR60","doi-asserted-by":"publisher","first-page":"1201","DOI":"10.1902\/jop.2006.050406","volume":"77","author":"RS Flateb\u00f8","year":"2006","unstructured":"Flateb\u00f8 RS, Johannessen AC, Gr\u00f8nnings\u00e6ter AG, B\u00f8e OE, Gjerdet NR, Grung B, Leknes KN (2006) Host response to titanium dental implant placement evaluated in a human oral model. J Periodontol 77:1201\u20131210. https:\/\/doi.org\/10.1902\/jop.2006.050406","journal-title":"J Periodontol"},{"key":"3785_CR61","doi-asserted-by":"publisher","first-page":"528","DOI":"10.1016\/j.jdent.2013.03.008","volume":"41","author":"JCM Souza","year":"2013","unstructured":"Souza JCM, Ponthiaux P, Henriques M, Oliveira R, Teughels W, Celis JP, Rocha LA (2013) Corrosion behaviour of titanium in the presence of Streptococcus mutans. J Dent 41:528\u2013534. https:\/\/doi.org\/10.1016\/j.jdent.2013.03.008","journal-title":"J Dent"},{"key":"3785_CR62","doi-asserted-by":"publisher","first-page":"306","DOI":"10.4041\/kjod.2017.47.5.306","volume":"47","author":"GY Huang","year":"2017","unstructured":"Huang GY, Jiang HB, Cha JY, Kim KM, Hwang CJ (2017) The effect of fluoride-containing oral rinses on the corrosion resistance of titanium alloy (Ti-6Al-4V). Korean J Orthod 47:306\u2013312. https:\/\/doi.org\/10.4041\/kjod.2017.47.5.306","journal-title":"Korean J Orthod"},{"key":"3785_CR63","doi-asserted-by":"publisher","unstructured":"Vieira AC, Ribeiro AR, Rocha LA, Celis JP. (2006)\u00a0Influence of pH and corrosion inhibitors on the tribocorrosion of titanium in artificial saliva. Wear 261(9):994-1001.\u00a0https:\/\/doi.org\/10.1016\/j.wear.2006.03.031","DOI":"10.1016\/j.wear.2006.03.031"},{"key":"3785_CR64","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1111\/clr.12607","volume":"28","author":"A Messias","year":"2017","unstructured":"Messias A, Rocha S, Calha N, Neto MA, Nicolau P, Guerra F (2017) Effect of intentional abutment disconnection on the micro-movements of the implant\u2013abutment assembly: a 3D digital image correlation analysis. Clin Oral Implants Res 28:9\u201316. https:\/\/doi.org\/10.1111\/clr.12607","journal-title":"Clin Oral Implants Res"},{"key":"3785_CR65","doi-asserted-by":"publisher","first-page":"2379","DOI":"10.1016\/j.actbio.2014.02.027","volume":"10","author":"H Matusiewicz","year":"2014","unstructured":"Matusiewicz H (2014) Potential release of in vivo trace metals from metallic medical implants in the human body: from ions to nanoparticles \u2013 a systematic analytical review. Acta Biomater 10:2379\u20132403. https:\/\/doi.org\/10.1016\/j.actbio.2014.02.027","journal-title":"Acta Biomater"},{"key":"3785_CR66","doi-asserted-by":"crossref","unstructured":"Delgado-Ruiz R, Romanos G (2018) Potential causes of titanium particle and ion release in implant dentistry: a systematic review. Int J Mol Sci 19","DOI":"10.3390\/ijms19113585"},{"key":"3785_CR67","doi-asserted-by":"publisher","first-page":"412","DOI":"10.1111\/j.1600-0714.2010.00958.x","volume":"40","author":"RS Flateb\u00f8","year":"2011","unstructured":"Flateb\u00f8 RS, H\u00f8l PJ, Leknes KN, Kosler J, Lie SA, Gjerdet NR (2011) Mapping of titanium particles in peri-implant oral mucosa by laser ablation inductively coupled plasma mass spectrometry and high-resolution optical darkfield microscopy. J Oral Pathol Med 40:412\u2013420. https:\/\/doi.org\/10.1111\/j.1600-0714.2010.00958.x","journal-title":"J Oral Pathol Med"},{"key":"3785_CR68","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1177\/154411130201300108","volume":"13","author":"W Geurtsen","year":"2002","unstructured":"Geurtsen W (2002) Biocompatibility of dental casting alloys. Crit Rev Oral Biol Med 13:71\u201384","journal-title":"Crit Rev Oral Biol Med"},{"key":"3785_CR69","doi-asserted-by":"publisher","first-page":"9309","DOI":"10.1038\/s41598-019-45797-6","volume":"9","author":"W Souza","year":"2019","unstructured":"Souza W, Piperni SG, Laviola P, Rossi AL, Rossi MID, Archanjo BS, Leite PE, Fernandes MH, Rocha LA, Granjeiro JM, Ribeiro AR (2019) The two faces of titanium dioxide nanoparticles bio-camouflage in 3D bone spheroids. Sci Rep 9:9309. https:\/\/doi.org\/10.1038\/s41598-019-45797-6","journal-title":"Sci Rep"},{"key":"3785_CR70","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1111\/j.1708-8208.2002.tb00149.x","volume":"4","author":"A Tawse-Smith","year":"2002","unstructured":"Tawse-Smith A, Payne AGT, Kumara R, Thomson WM (2002) Early loading of unsplinted implants supporting mandibular overdentures using a one-stage operative procedure with two different implant systems: a 2-year report. Clin Implant Dent Relat Res 4:33\u201342","journal-title":"Clin Implant Dent Relat Res"},{"key":"3785_CR71","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1902\/jop.1994.65.2.147","volume":"65","author":"K Takahashi","year":"1994","unstructured":"Takahashi K, Takashiba S, Nagai A, Takigawa M, Myoukai F, Kurihara H, Murayama Y (1994) Assessment of Interleukin-6 in the pathogenesis of periodontal disease. J Periodontol 65:147\u2013153. https:\/\/doi.org\/10.1902\/jop.1994.65.2.147","journal-title":"J Periodontol"},{"key":"3785_CR72","doi-asserted-by":"publisher","first-page":"3757","DOI":"10.1016\/S0142-9612(02)00115-1","volume":"23","author":"R Kumazawa","year":"2002","unstructured":"Kumazawa R, Watari F, Takashi N, Tanimura Y, Uo M, Totsuka Y (2002) Effects of Ti ions and particles on neutrophil function and morphology. Biomaterials 23:3757\u20133764. https:\/\/doi.org\/10.1016\/S0142-9612(02)00115-1","journal-title":"Biomaterials"},{"key":"3785_CR73","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1002\/jbm.820280111","volume":"28","author":"AS Shanbhag","year":"1994","unstructured":"Shanbhag AS, Jacobs JJ, Black J, Galante JO, Glant TT (1994) Macrophage\/particle interactions: effect of size, composition and surface area. J Biomed Mater Res 28:81\u201390. https:\/\/doi.org\/10.1002\/jbm.820280111","journal-title":"J Biomed Mater Res"},{"key":"3785_CR74","doi-asserted-by":"publisher","first-page":"1933","DOI":"10.1007\/s10856-011-4375-7","volume":"22","author":"Y Zhang","year":"2011","unstructured":"Zhang Y, Yu W, Jiang X, Lv K, Sun S, Zhang F (2011) Analysis of the cytotoxicity of differentially sized titanium dioxide nanoparticles in murine MC3T3-E1 preosteoblasts. J Mater Sci Mater Med 22:1933\u20131945. https:\/\/doi.org\/10.1007\/s10856-011-4375-7","journal-title":"J Mater Sci Mater Med"},{"key":"3785_CR75","doi-asserted-by":"publisher","first-page":"469","DOI":"10.1016\/j.jprot.2014.06.011","volume":"108","author":"J Sund","year":"2014","unstructured":"Sund J, Palom\u00e4ki J, Ahonen N, Savolainen K, Alenius H, Puustinen A (2014) Phagocytosis of nano-sized titanium dioxide triggers changes in protein acetylation. J Proteome 108:469\u2013483. https:\/\/doi.org\/10.1016\/j.jprot.2014.06.011","journal-title":"J Proteome"},{"key":"3785_CR76","doi-asserted-by":"publisher","first-page":"555","DOI":"10.3109\/08820139.2013.822766","volume":"42","author":"PPC Souza","year":"2013","unstructured":"Souza PPC, Lerner UH (2013) The role of cytokines in inflammatory bone loss. Immunol Investig 42:555\u2013622. https:\/\/doi.org\/10.3109\/08820139.2013.822766","journal-title":"Immunol Investig"},{"key":"3785_CR77","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1016\/j.bone.2009.06.004","volume":"45","author":"M Darowish","year":"2009","unstructured":"Darowish M, Rahman R, Li P et al (2009) Reduction of particle-induced osteolysis by interleukin-6 involves anti-inflammatory effect and inhibition of early osteoclast precursor differentiation. Bone 45:661\u2013668. https:\/\/doi.org\/10.1016\/j.bone.2009.06.004","journal-title":"Bone"},{"key":"3785_CR78","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1016\/j.cytogfr.2003.10.005","volume":"15","author":"KT Steeve","year":"2004","unstructured":"Steeve KT, Marc P, Sandrine T, Dominique H, Yannick F (2004) IL-6, RANKL, TNF-alpha\/IL-1: interrelations in bone resorption pathophysiology. Cytokine Growth Factor Rev 15:49\u201360. https:\/\/doi.org\/10.1016\/j.cytogfr.2003.10.005","journal-title":"Cytokine Growth Factor Rev"},{"key":"3785_CR79","doi-asserted-by":"publisher","first-page":"6096","DOI":"10.1016\/j.biomaterials.2006.08.023","volume":"27","author":"SB Goodman","year":"2006","unstructured":"Goodman SB, Ma T, Chiu R, Ramachandran R, Lane Smith R (2006) Effects of orthopaedic wear particles on osteoprogenitor cells. Biomaterials 27:6096\u20136101. https:\/\/doi.org\/10.1016\/j.biomaterials.2006.08.023","journal-title":"Biomaterials"},{"key":"3785_CR80","doi-asserted-by":"publisher","first-page":"1334","DOI":"10.1016\/j.biocel.2007.10.024","volume":"40","author":"SE Gill","year":"2008","unstructured":"Gill SE, Parks WC (2008) Metalloproteinases and their inhibitors: regulators of wound healing. Int J Biochem Cell Biol 40:1334\u20131347. https:\/\/doi.org\/10.1016\/j.biocel.2007.10.024","journal-title":"Int J Biochem Cell Biol"},{"key":"3785_CR81","doi-asserted-by":"publisher","first-page":"660","DOI":"10.1359\/jbmr.2001.16.4.660","volume":"16","author":"X Zhang","year":"2001","unstructured":"Zhang X, Morham SG, Langenbach R, Young DA, Xing L, Boyce BF, Puzas EJ, Rosier RN, O'Keefe RJ, Schwarz EM (2001) Evidence for a direct role of cyclo-oxygenase 2 in implant wear debris-induced osteolysis. J Bone Miner Res 16:660\u2013670. https:\/\/doi.org\/10.1359\/jbmr.2001.16.4.660","journal-title":"J Bone Miner Res"},{"key":"3785_CR82","doi-asserted-by":"publisher","first-page":"943","DOI":"10.1093\/rheumatology\/35.10.943","volume":"35","author":"MJ Perry","year":"1996","unstructured":"Perry MJ, Ponsford FM, Mortuza FY et al (1996) Osteolytic properties of the synovial-like tissue from aseptically failed joint prostheses. Br J Rheumatol 35:943\u2013950. https:\/\/doi.org\/10.1093\/rheumatology\/35.10.943","journal-title":"Br J Rheumatol"},{"key":"3785_CR83","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1016\/j.cytogfr.2004.06.004","volume":"15","author":"S Theoleyre","year":"2004","unstructured":"Theoleyre S, Wittrant Y, Tat SK, Fortun Y, Redini F, Heymann D (2004) The molecular triad OPG\/RANK\/RANKL: involvement in the orchestration of pathophysiological bone remodeling. Cytokine Growth Factor Rev 15:457\u2013475. https:\/\/doi.org\/10.1016\/j.cytogfr.2004.06.004","journal-title":"Cytokine Growth Factor Rev"}],"container-title":["Clinical Oral Investigations"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00784-021-03785-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00784-021-03785-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00784-021-03785-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,16]],"date-time":"2021-03-16T07:30:30Z","timestamp":1615879830000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00784-021-03785-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,22]]},"references-count":83,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2021,4]]}},"alternative-id":["3785"],"URL":"https:\/\/doi.org\/10.1007\/s00784-021-03785-z","relation":{},"ISSN":["1432-6981","1436-3771"],"issn-type":[{"value":"1432-6981","type":"print"},{"value":"1436-3771","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,2,22]]},"assertion":[{"value":"6 October 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 January 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 February 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}