{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T12:34:15Z","timestamp":1740141255673,"version":"3.37.3"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2018,1,3]],"date-time":"2018-01-03T00:00:00Z","timestamp":1514937600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100001871","name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia","doi-asserted-by":"publisher","award":["UID\/BIO\/00645\/2013","IF\/00364\/2013"],"award-info":[{"award-number":["UID\/BIO\/00645\/2013","IF\/00364\/2013"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia (PT)","award":["UID\/EEA\/50009\/2013"],"award-info":[{"award-number":["UID\/EEA\/50009\/2013"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Magn Reson Mater Phy"],"published-print":{"date-parts":[[2018,6]]},"DOI":"10.1007\/s10334-017-0669-1","type":"journal-article","created":{"date-parts":[[2018,1,8]],"date-time":"2018-01-08T15:23:35Z","timestamp":1515425015000},"page":"449-456","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Distortion correction of echo planar images applying the concept of finite rate of innovation to point spread function mapping (FRIP)"],"prefix":"10.1007","volume":"31","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7425-5717","authenticated-orcid":false,"given":"Rita G.","family":"Nunes","sequence":"first","affiliation":[]},{"given":"Joseph V.","family":"Hajnal","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2018,1,3]]},"reference":[{"key":"669_CR1","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1002\/mrm.1910340111","volume":"34","author":"P Jezzard","year":"1995","unstructured":"Jezzard P, Balaban RS (1995) Correction for geometric distortion in echo planar images from B0 field variations. Magn Reson Med 34:65\u201373","journal-title":"Magn Reson Med"},{"key":"669_CR2","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1002\/mrm.1910380509","volume":"38","author":"MD Robson","year":"1997","unstructured":"Robson MD, Gore JC, Constable RT (1997) Measurement of the point spread function in MRI using constant time imaging. Magn Reson Med 38:733\u2013740","journal-title":"Magn Reson Med"},{"key":"669_CR3","doi-asserted-by":"crossref","first-page":"1156","DOI":"10.1002\/mrm.20261","volume":"52","author":"M Zaitsev","year":"2004","unstructured":"Zaitsev M, Hennig J, Speck O (2004) Point spread function mapping with parallel imaging techniques and high acceleration factors: fast, robust, and flexible method for echo-planar imaging distortion correction. Magn Reson Med 52:1156\u20131166","journal-title":"Magn Reson Med"},{"key":"669_CR4","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1002\/mrm.10200","volume":"48","author":"H Zeng","year":"2002","unstructured":"Zeng H, Constable RT (2002) Image distortion correction in EPI: comparison of field mapping with point spread function mapping. Magn Reson Med 48:137\u2013146","journal-title":"Magn Reson Med"},{"key":"669_CR5","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1007\/s10334-011-0275-6","volume":"25","author":"MH In","year":"2012","unstructured":"In MH, Speck O (2012) Highly accelerated PSF-mapping for EPI distortion correction with improved fidelity. Magn Reson Mater Phy Biol Med 25:183\u2013192","journal-title":"Magn Reson Mater Phy Biol Med"},{"key":"669_CR6","doi-asserted-by":"crossref","first-page":"1650","DOI":"10.1002\/mrm.24396","volume":"69","author":"I Dragonu","year":"2013","unstructured":"Dragonu I, Lange T, Baxan N, Snyder J, Hennig J, Zaitsev M (2013) Accelerated point spread function mapping using signal modeling for accurate echo-planar imaging geometric distortion correction. Magn Reson Med 69:1650\u20131656","journal-title":"Magn Reson Med"},{"key":"669_CR7","doi-asserted-by":"crossref","first-page":"1417","DOI":"10.1109\/TSP.2002.1003065","volume":"50","author":"M Vetterli","year":"2002","unstructured":"Vetterli M, Marziliano P, Blu T (2002) Sampling signals with finite rate of innovation. IEEE Trans Signal Process 50:1417\u20131428","journal-title":"IEEE Trans Signal Process"},{"key":"669_CR8","doi-asserted-by":"crossref","unstructured":"Dragotti PL, Homann F (2009) Sampling signals with finite rate of innovation in the presence of noise. In: 2009 IEEE Int. Conf. Acoust. Speech Signal Process. IEEE, pp 2941\u20132944","DOI":"10.1109\/ICASSP.2009.4960240"},{"key":"669_CR9","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1109\/MSP.2007.914998","volume":"25","author":"T Blu","year":"2008","unstructured":"Blu T, Dragotti P-L (2008) Sparse sampling of signal innovations. Signal Process Mag IEEE 25:31\u201340","journal-title":"Signal Process Mag IEEE"},{"key":"669_CR10","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1038\/nature11971","volume":"495","author":"D Ma","year":"2013","unstructured":"Ma D, Gulani V, Seiberlich N, Liu K, Sunshine JL, Duerk JL, Griswold MA (2013) Magnetic resonance fingerprinting. Nature 495:187\u2013192","journal-title":"Nature"},{"key":"669_CR11","doi-asserted-by":"crossref","first-page":"A45","DOI":"10.1186\/2197-7364-1-S1-A45","volume":"1","author":"RG Nunes","year":"2014","unstructured":"Nunes RG, Hajnal JV (2014) Highly accelerated Point-Spread Function mapping based on Finite Rate of Innovation for EPI distortion correction. EJNMMI Phys 1:A45","journal-title":"EJNMMI Phys"},{"key":"669_CR12","unstructured":"Oh C, Hilal S, Cho Z, Oh C, Hilal S CZ (1988) Selective partial inversion recovery (SPIR) in steady state for selective saturation magnetic resonance imaging (MRI). In: Proceedings of the 7th Annual Meeting of ISMRM, San Francisco, USA, p 324"},{"key":"669_CR13","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1002\/hbm.10062","volume":"17","author":"SM Smith","year":"2002","unstructured":"Smith SM (2002) Fast robust automated brain extraction. Hum Brain Mapp 17:143\u2013155","journal-title":"Hum Brain Mapp"},{"key":"669_CR14","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1002\/mrm.1910380114","volume":"38","author":"MH Buonocore","year":"1997","unstructured":"Buonocore MH, Gao L (1997) Ghost artifact reduction for echo planar imaging using image phase correction. Magn Reson Med 38:89\u2013100","journal-title":"Magn Reson Med"},{"key":"669_CR15","doi-asserted-by":"crossref","first-page":"782","DOI":"10.1016\/j.neuroimage.2011.09.015","volume":"62","author":"M Jenkinson","year":"2012","unstructured":"Jenkinson M, Beckmann CF, Behrens TEJ, Woolrich MW, Smith SM (2012) FSL. Neuroimage 62:782\u2013790","journal-title":"Neuroimage"},{"key":"669_CR16","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1002\/mrm.21187","volume":"57","author":"Q-S Xiang","year":"2007","unstructured":"Xiang Q-S, Ye FQ (2007) Correction for geometric distortion and N\/2 ghosting in EPI by phase labeling for additional coordinate encoding (PLACE). Magn Reson Med 57:731\u2013741","journal-title":"Magn Reson Med"},{"key":"669_CR17","doi-asserted-by":"crossref","first-page":"1239","DOI":"10.1002\/mrm.23317","volume":"68","author":"SH Oh","year":"2012","unstructured":"Oh SH, Chung JY, In MH, Zaitsev M, Kim YB, Speck O, Cho ZH (2012) Distortion correction in EPI at ultra-high-field MRI using PSF mapping with optimal combination of shift detection dimension. Magn Reson Med 68:1239\u20131246","journal-title":"Magn Reson Med"},{"key":"669_CR18","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0116320","author":"MH In","year":"2015","unstructured":"In MH, Posnansky O, Beall EB, Lowe MJ, Speck O (2015) Distortion correction in EPI using an extended PSF method with a reversed phase gradient approach. PLoS One. https:\/\/doi.org\/10.1371\/journal.pone.0116320","journal-title":"PLoS One"},{"key":"669_CR19","unstructured":"Bowtell R, McIntyre DJO, Commandre M-J, Glover PM, Mansfield P (1994) Correction of geometric distortion in echo planar images. In: Proceedings of the 2nd Annual Meeting of ISMRM, San Francisco, USA, p 411"},{"key":"669_CR20","doi-asserted-by":"crossref","first-page":"870","DOI":"10.1016\/S1053-8119(03)00336-7","volume":"20","author":"JLR Andersson","year":"2003","unstructured":"Andersson JLR, Skare S, Ashburner J (2003) How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging. Neuroimage 20:870\u2013888","journal-title":"Neuroimage"},{"key":"669_CR21","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/j.neuroimage.2009.11.044","volume":"50","author":"D Holland","year":"2010","unstructured":"Holland D, Kuperman JM, Dale AM (2010) Efficient correction of inhomogeneous static magnetic field-induced distortion in Echo Planar Imaging. Neuroimage 50:175\u2013183","journal-title":"Neuroimage"},{"key":"669_CR22","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1007\/s10334-011-0251-1","volume":"24","author":"JY Chung","year":"2011","unstructured":"Chung JY, In MH, Oh SH, Zaitsev M, Speck O, Cho ZH (2011) An improved PSF mapping method for EPI distortion correction in human brain at ultra high field (7T). Magn Reson Mater Phy Biol Med 24:179\u2013190","journal-title":"Magn Reson Mater Phy Biol Med"},{"key":"669_CR23","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1002\/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S","volume":"42","author":"KP Pruessmann","year":"1999","unstructured":"Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P (1999) SENSE: sensitivity encoding for fast MRI. Magn Reson Med 42:952\u2013962","journal-title":"Magn Reson Med"}],"container-title":["Magnetic Resonance Materials in Physics, Biology and Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10334-017-0669-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10334-017-0669-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10334-017-0669-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2018,5,29]],"date-time":"2018-05-29T02:40:15Z","timestamp":1527561615000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10334-017-0669-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,1,3]]},"references-count":23,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2018,6]]}},"alternative-id":["669"],"URL":"https:\/\/doi.org\/10.1007\/s10334-017-0669-1","relation":{},"ISSN":["0968-5243","1352-8661"],"issn-type":[{"type":"print","value":"0968-5243"},{"type":"electronic","value":"1352-8661"}],"subject":[],"published":{"date-parts":[[2018,1,3]]}}}