{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,24]],"date-time":"2026-02-24T07:59:55Z","timestamp":1771919995105,"version":"3.50.1"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2012,10,7]],"date-time":"2012-10-07T00:00:00Z","timestamp":1349568000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Mater Sci: Mater Med"],"published-print":{"date-parts":[[2013,1]]},"DOI":"10.1007\/s10856-012-4778-0","type":"journal-article","created":{"date-parts":[[2012,10,6]],"date-time":"2012-10-06T07:39:47Z","timestamp":1349509187000},"page":"231-239","source":"Crossref","is-referenced-by-count":9,"title":["Artifact level produced by different femoral head prostheses in CT imaging: diamond coated silicon nitride as total hip replacement material"],"prefix":"10.1007","volume":"24","author":[{"given":"Simone P.","family":"Rodrigues","sequence":"first","affiliation":[]},{"given":"Jos\u00e9 M.","family":"Paiva","sequence":"additional","affiliation":[]},{"given":"Silvia","family":"De Francesco","sequence":"additional","affiliation":[]},{"given":"Margarida I.","family":"Amaral","sequence":"additional","affiliation":[]},{"given":"Filipe J.","family":"Oliveira","sequence":"additional","affiliation":[]},{"given":"Rui F.","family":"Silva","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2012,10,7]]},"reference":[{"issue":"4","key":"4778_CR1","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1080\/00016470310017668","volume":"74","author":"S Santavirta","year":"2003","unstructured":"Santavirta S, B\u00f6hler M, Harris WH, Konttinen YT, Lappalainen R, Muratoglu O, et al. Alternative materials to improve total hip replacement tribology. Acta Orthop Scand. 2003;74(4):380\u20138.","journal-title":"Acta Orthop Scand"},{"key":"4778_CR2","doi-asserted-by":"crossref","first-page":"1137","DOI":"10.1098\/rsif.2008.0151","volume":"5","author":"M Navarro","year":"2008","unstructured":"Navarro M, Michiardi A, Casta\u00f1o O, Planell JA. Biomaterials in orthopaedics. J R Soc Interface. 2008;5:1137\u201358.","journal-title":"J R Soc Interface"},{"key":"4778_CR3","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1016\/j.ejrad.2006.08.008","volume":"60","author":"BV Berg","year":"2006","unstructured":"Berg BV, Malghem J, Maldague B, Lecouvet F. Multi-detector CT imaging in the postoperative orthopedic patient with metal hardware. Eur J Radiol. 2006;60:470\u20139.","journal-title":"Eur J Radiol"},{"issue":"1","key":"4778_CR4","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1007\/s00776-003-0744-5","volume":"9","author":"S Mitsuhashi","year":"2004","unstructured":"Mitsuhashi S, Harada Y, Yanagawa N, Kamikawa K, Kitahara H, Moriya H. Automatic measurement of polyethylene modification in metal-backed artificial hip joints using three-dimensional CT. J Orthop Sci. 2004;9(1):10\u20135.","journal-title":"J Orthop Sci"},{"key":"4778_CR5","doi-asserted-by":"crossref","first-page":"918","DOI":"10.1259\/bjr\/19559792","volume":"79","author":"M Aubin","year":"2006","unstructured":"Aubin M, Morin O, Chen J, Gillis A, Pickett B, Aubry JF, et al. The use of megavoltage cone-beam CT to complement CT for target definition in pelvic radiotherapy in the presence of hip replacement. Br J Radiol. 2006;79:918\u201321.","journal-title":"Br J Radiol"},{"issue":"4","key":"4778_CR6","doi-asserted-by":"crossref","first-page":"1224","DOI":"10.1016\/j.ijrobp.2005.02.052","volume":"62","author":"M Yazdia","year":"2005","unstructured":"Yazdia M, Gingras L, Beaulieu L. An adaptative approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: experimental and clinical studies. Int J Radiat Oncol Biol Phys. 2005;62(4):1224\u201331.","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"4778_CR7","doi-asserted-by":"crossref","first-page":"1679","DOI":"10.1148\/rg.246045065","volume":"24","author":"JF Barret","year":"2004","unstructured":"Barret JF, Keat N. Artifacts in CT: recognition and avoidance. RadioGraphics. 2004;24:1679\u201391.","journal-title":"RadioGraphics"},{"key":"4778_CR8","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1007\/s00256-008-0630-5","volume":"38","author":"PT Liu","year":"2009","unstructured":"Liu PT, Pavlicek WP, Peter MB, Spangehl MJ, Roberts CC, Paden RG. Metal artifact reduction image reconstruction algorithm for CT of implanted metal orthopedic devices: a work in progress. Skelet Radiol. 2009;38:797\u2013802.","journal-title":"Skelet Radiol"},{"issue":"3","key":"4778_CR9","doi-asserted-by":"crossref","first-page":"977","DOI":"10.1109\/23.856534","volume":"47","author":"BD Man","year":"2000","unstructured":"Man BD, Nuyts J, Dupont P, Marchal G, Suetens P. Reduction of metal streak artifacts in X-ray computed tomography using a transmission maximum a posteriori algorithm. IEEE Trans Nucl Sci. 2000;47(3):977\u201381.","journal-title":"IEEE Trans Nucl Sci"},{"issue":"2","key":"4778_CR10","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1097\/00004728-199703000-00024","volume":"21","author":"DD Robertson","year":"1997","unstructured":"Robertson DD, Yuan J, Wang G, Vannier MW. Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction. J Comput Assist Tomogr. 1997;21(2):293\u20138.","journal-title":"J Comput Assist Tomogr"},{"key":"4778_CR11","doi-asserted-by":"crossref","first-page":"2881","DOI":"10.1007\/s10856-008-3417-2","volume":"19","author":"M Mazzocchi","year":"2008","unstructured":"Mazzocchi M, Bellosi A. On the possibility of silicon nitride as a ceramic for structural orthopaedic implants. Part I: processing, microstructure, mechanical properties, cytotoxicity. J Mater Sci Mater Med. 2008;19:2881\u20137.","journal-title":"J Mater Sci Mater Med"},{"key":"4778_CR12","doi-asserted-by":"crossref","first-page":"1135","DOI":"10.1023\/B:JMSM.0000046396.14073.92","volume":"15","author":"A Neumann","year":"2004","unstructured":"Neumann A, Reske T, Held M, Jahnke K. Comparative investigation of the biocompatibility of various silicon nitride ceramic qualities in vitro. J Mater Sci Mater Med. 2004;15:1135\u201340.","journal-title":"J Mater Sci Mater Med"},{"issue":"2","key":"4778_CR13","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1007\/s11249-006-9032-9","volume":"21","author":"CS Abreu","year":"2006","unstructured":"Abreu CS, Oliveira FJ, Belmonte M, Fernandes AJS, Gomes JR, Silva RF. CVD diamond coated silicon nitride self-mated systems: tribological behaviour under high loads. Tribol Lett. 2006;21(2):141\u201351.","journal-title":"Tribol Lett"},{"key":"4778_CR14","doi-asserted-by":"crossref","first-page":"1962","DOI":"10.1016\/j.surfcoat.2009.11.015","volume":"204","author":"M Amaral","year":"2010","unstructured":"Amaral M, Abreu CS, Fernandes AJS, Oliveira FJ, Gomes JR, Silva RF. Nanodiamond-based tribosystems. Surf Coat Technol. 2010;204:1962\u20139.","journal-title":"Surf Coat Technol"},{"key":"4778_CR15","doi-asserted-by":"crossref","first-page":"1339","DOI":"10.1016\/j.matchar.2007.11.007","volume":"59","author":"CC Guedes e Silva","year":"2008","unstructured":"Guedes e Silva CC, K\u00f6nig B, Carbonaric MJ, Yoshimoto M, Allegrini S, Bressiani JC. Bone growth around silicon nitride implants\u2014an evaluation by scanning electron microscopy. Mater Charact. 2008;59:1339\u201341.","journal-title":"Mater Charact"},{"key":"4778_CR16","doi-asserted-by":"crossref","first-page":"2889","DOI":"10.1016\/j.actbio.2012.04.031","volume":"8","author":"BS Bal","year":"2012","unstructured":"Bal BS, Rahaman MN. Orthopedic applications of silicon nitride ceramics. Acta Biomater. 2012;8:2889\u201398.","journal-title":"Acta Biomater"},{"key":"4778_CR17","doi-asserted-by":"crossref","first-page":"2434","DOI":"10.1016\/j.actbio.2012.03.029","volume":"8","author":"R Sonntag","year":"2012","unstructured":"Sonntag R, Reinders J, Kretzer JP. What\u2019s next? Alternative materials for articulation in total joint replacement. Acta Biomater. 2012;8:2434\u201341.","journal-title":"Acta Biomater"},{"issue":"1","key":"4778_CR18","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.arth.2008.01.300","volume":"24","author":"BS Bal","year":"2009","unstructured":"Bal BS, Khandkar A, Lakshminarayanan R, Clarke I, Hoffman AA, Rahaman MN. Fabrication and testing of silicon nitride bearings in total hip arthroplasty: winner of the 2007 \u201cHAP\u201d PAUL Award. J Arthroplast. 2009;24(1):110\u20136.","journal-title":"J Arthroplast"},{"key":"4778_CR19","doi-asserted-by":"crossref","first-page":"848","DOI":"10.1016\/j.diamond.2007.12.070","volume":"17","author":"M Amaral","year":"2008","unstructured":"Amaral M, Abreu CS, Oliveira FJ, Gomes JR, Silva RF. Tribological characterization of NCD in physiological fluids. Diam Relat Mater. 2008;17:848\u201352.","journal-title":"Diam Relat Mater"},{"key":"4778_CR20","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2008\/894352","volume":"2008","author":"M Amaral","year":"2008","unstructured":"Amaral M, Gomes PS, Lopes MA, Santos JD, Silva RF, Fernandes MH. Nanocrystalline diamond as a coating for joint implants: cytotoxicity and biocompatibility assessment. J Nanomater. 2008;2008:1\u20139.","journal-title":"J Nanomater"},{"key":"4778_CR21","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1016\/j.actbio.2008.08.015","volume":"5","author":"M Amaral","year":"2009","unstructured":"Amaral M, Gomes PS, Lopes MA, Santos JD, Silva RF, Fernandes MH. Cytotoxicity evaluation of nanocrystalline diamond coatings by fibroblast cell cultures. Acta Biomater. 2009;5:755\u201363.","journal-title":"Acta Biomater"},{"issue":"1","key":"4778_CR22","doi-asserted-by":"crossref","first-page":"235","DOI":"10.3938\/jkps.51.235","volume":"51","author":"HK Kim","year":"2007","unstructured":"Kim HK, Kum O, Max NL. Computer-aided CT image analysis based on clustered hounsfield values. J Korean Phys Soc. 2007;51(1):235\u201344.","journal-title":"J Korean Phys Soc"},{"issue":"1591","key":"4778_CR23","first-page":"1603","volume":"48","author":"C Coolens","year":"2003","unstructured":"Coolens C, Childs PJ. Calibration of CT Hounsfield units for radiotherapy treatment planning of patients with metallic hip prostheses: the use of the extended CT-scale. Phys Med Biol. 2003;48(1591):1603.","journal-title":"Phys Med Biol"},{"key":"4778_CR24","unstructured":"Siemens (2005) AG Medical Solutions\u2014Somatom sensation 40\/64 application guide."},{"key":"4778_CR25","unstructured":"Seredy C, Zeiger S, AMEDICA\/US SPINE\u00ae Enters the reconstructive surgery market\u2014First silicon nitride total hip replacement. http:\/\/amedica.com\/company\/news\/02.17.11.pdf . Accessed July 2011."}],"updated-by":[{"DOI":"10.1007\/s10856-012-4792-2","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2012,11,11]],"date-time":"2012-11-11T00:00:00Z","timestamp":1352592000000}}],"container-title":["Journal of Materials Science: Materials in Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10856-012-4778-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10856-012-4778-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10856-012-4778-0","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,31]],"date-time":"2019-05-31T03:41:50Z","timestamp":1559274110000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10856-012-4778-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,10,7]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2013,1]]}},"alternative-id":["4778"],"URL":"https:\/\/doi.org\/10.1007\/s10856-012-4778-0","relation":{"correction":[{"id-type":"doi","id":"10.1007\/s10856-012-4792-2","asserted-by":"object"}]},"ISSN":["0957-4530","1573-4838"],"issn-type":[{"value":"0957-4530","type":"print"},{"value":"1573-4838","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,10,7]]}}}