{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,18]],"date-time":"2026-01-18T02:30:07Z","timestamp":1768703407750,"version":"3.49.0"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2017,3,20]],"date-time":"2017-03-20T00:00:00Z","timestamp":1489968000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100002322","name":"Coordena\u00e7\u00e3o de Aperfei\u00e7oamento de Pessoal de N\u00edvel Superior","doi-asserted-by":"publisher","award":["PVE 2014 (cod. 150787\/2015-4)"],"award-info":[{"award-number":["PVE 2014 (cod. 150787\/2015-4)"]}],"id":[{"id":"10.13039\/501100002322","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100005856","name":"Faculdade de Ci\u00eancias e Tecnologia, Universidade Nova de Lisboa","doi-asserted-by":"publisher","award":["EXCL\/EMSTEC\/0460\/2012"],"award-info":[{"award-number":["EXCL\/EMSTEC\/0460\/2012"]}],"id":[{"id":"10.13039\/501100005856","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Mater Sci: Mater Med"],"published-print":{"date-parts":[[2017,5]]},"DOI":"10.1007\/s10856-017-5879-6","type":"journal-article","created":{"date-parts":[[2017,3,20]],"date-time":"2017-03-20T08:07:28Z","timestamp":1489997248000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":20,"title":["Wear of Morse taper and external hexagon implant joints after abutment removal"],"prefix":"10.1007","volume":"28","author":[{"given":"Abra\u00e3o M.","family":"Prado","sequence":"first","affiliation":[]},{"given":"Jorge","family":"Pereira","sequence":"additional","affiliation":[]},{"given":"Filipe S.","family":"Silva","sequence":"additional","affiliation":[]},{"given":"Bruno","family":"Henriques","sequence":"additional","affiliation":[]},{"given":"Rubens M.","family":"Nascimento","sequence":"additional","affiliation":[]},{"given":"Cesar A. M.","family":"Benfatti","sequence":"additional","affiliation":[]},{"given":"Jos\u00e9","family":"L\u00f3pez-L\u00f3pez","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7999-4009","authenticated-orcid":false,"given":"J\u00falio C. M.","family":"Souza","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2017,3,20]]},"reference":[{"issue":"3","key":"5879_CR1","first-page":"233","volume":"19","author":"GD Giglio","year":"1999","unstructured":"Giglio GD, Abutment selection in implant-supported fixed prosthodontics. Int J Periodontics Restorative Dent. 1999;19(3):233\u201341.","journal-title":"Int J Periodontics Restorative Dent"},{"issue":"1","key":"5879_CR2","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1111\/j.1708-8208.2000.tb00104.x","volume":"2","author":"S Hansson","year":"2000","unstructured":"Hansson S, Implant-Abutment Interface: biomechanical study of flat top versus conical. Clin Implant Dent Relat Res. 2000;2(1):33\u201341.","journal-title":"Clin Implant Dent Relat Res"},{"issue":"4","key":"5879_CR3","doi-asserted-by":"crossref","first-page":"813","DOI":"10.11607\/jomi.4173","volume":"31","author":"J Pereira","year":"2016","unstructured":"Pereira J, Morsch CS, Henriques B, Nascimento RM, Benfatti CAM, Silva FS, L\u00f3pez-L\u00f3pez J, Souza JCM. Removal torque and biofilm accumulation at two dental implant-abutment joints after fatigue. Intern J Oral Maxillof Impl. 2016;31(4):813.","journal-title":"Intern J Oral Maxillof Impl"},{"issue":"4","key":"5879_CR4","doi-asserted-by":"crossref","first-page":"381","DOI":"10.11607\/ijp.4759","volume":"29","author":"AM Prado","year":"2016","unstructured":"Prado AM, Pereira J, Henriques B, Benfatti CAM, Magini RS, Silva FS, L\u00f3pez-L\u00f3pez J, Souza JCM. Biofilm affecting the mechanical integrity of implant-abutment joints. Intern J Prosthod. 2016;29(4):381.","journal-title":"Intern J Prosthod"},{"key":"5879_CR5","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1067\/mpr.2001.112796","volume":"85","author":"D Gratton","year":"2001","unstructured":"Gratton D, Aquilino S, Stanford C. Micromotion and dynamic fatigue properties of the dental implant\u2013abutment interface. J Prosthet Dent. 2001;85:47\u201352.","journal-title":"J Prosthet Dent"},{"issue":"2","key":"5879_CR6","first-page":"253","volume":"23","author":"HC Quek","year":"2008","unstructured":"Quek HC, Tan KB, Nicholls JI. Load fatigue performance of four implant-abutment interface designs: effect of torque level and implant system. Int J Oral Maxillofac Implants. 2008;23(2):253\u201362.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"4","key":"5879_CR7","first-page":"797","volume":"26","author":"YL Seetoh","year":"2011","unstructured":"Seetoh YL, Tan KB, Chua EK, Quek HC, Nicholls JI. Load fatigue performance of conical implant-abutment connections. Int J Oral Maxillofac Implants. 2011;26(4):797\u2013806.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"1","key":"5879_CR8","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1097\/ID.0b013e31823fcbce","volume":"21","author":"WG Assun\u00e7\u00e3o","year":"2012","unstructured":"Assun\u00e7\u00e3o WG, Delben JA, Tabata LF, Bar\u00e3o VAR, Gomes EA, Garcia IR. Preload evaluation of different screws in external hexagon joint. Implant Dent. 2012;21(1):46\u201350.","journal-title":"Implant Dent"},{"issue":"1","key":"5879_CR9","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.jpor.2010.05.002","volume":"55","author":"WG Assun\u00e7\u00e3o","year":"2011","unstructured":"Assun\u00e7\u00e3o WG, Bar\u00e3o VAR, Delben JA, Gomes \u00c9A, Garcia IR. Effect of unilateral misfit on preload of retention screws of implant-supported prostheses submitted to mechanical cycling. J Prosthodont Res. 2011;55(1):12\u20138.","journal-title":"J Prosthodont Res"},{"key":"5879_CR10","doi-asserted-by":"crossref","unstructured":"Gil FJ, Herrero-Climent M, L\u00e1zaro P, Rios JV, Implant-abutment connections: influence of the design on the microgap and their fatigue and fracture behavior of dental implants, J Mater Sci Mater Med. 2014;25(7):1825\u201330.","DOI":"10.1007\/s10856-014-5211-7"},{"key":"5879_CR11","doi-asserted-by":"crossref","first-page":"209","DOI":"10.11607\/jomi.3110","volume":"28","author":"CDA Vianna","year":"2013","unstructured":"Vianna CDA, Juliana DDS, Delben A, Bar\u00e3o VAR, Ferreira MB, Henrique P, Assun\u00e7ao WG. Torque stability of different abutment screws submitted to mechanical cycling. Int J Oral Maxillofac Implants. 2013;28:209\u201314.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"6","key":"5879_CR12","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1016\/j.jdent.2012.02.009","volume":"40","author":"S Saidin","year":"2012","unstructured":"Saidin S, Abdul Kadir MR, Sulaiman E, Abu Kasim NH. Effects of different implant-abutment connections on micromotion and stress distribution: prediction of microgap formation. J Dent. 2012;40(6):467\u201374.","journal-title":"J Dent"},{"issue":"7\u20138","key":"5879_CR13","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/S0300-5712(02)00065-9","volume":"30","author":"S Sahin","year":"2002","unstructured":"Sahin S, Cehreli MC, Yal\u00e7in E. The influence of functional forces on the biomechanics of implant-supported prostheses--a review. J Dent. 2002;30(7\u20138):271\u201382.","journal-title":"J Dent"},{"issue":"4","key":"5879_CR14","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1111\/j.1532-849X.2012.00941.x","volume":"22","author":"ARC Duarte","year":"2013","unstructured":"Duarte ARC, Neto JPS, Souza JCM, Bonachela WC. Detorque evaluation of dental abutment screws after immersion in a fluoridated artificial saliva solution. J Prosthodont. 2013;22(4):275\u201381.","journal-title":"J Prosthodont"},{"issue":"3","key":"5879_CR15","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1067\/mpr.2000.108758","volume":"84","author":"Ra Zavanelli","year":"2000","unstructured":"Zavanelli Ra, Henriques GEP, Ferreira I, Rollo JMDA. Corrosion-fatigue life of commercially pure titanium and Ti-6Al-4V alloys in different storage environments,. J Prosthet Dent. 2000;84(3):4\u20139.","journal-title":"J Prosthet Dent"},{"key":"5879_CR16","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1016\/j.wear.2012.05.030","volume":"292\u2013293","author":"JCM Souza","year":"2012","unstructured":"Souza JCM, Barbosa SL, Ariza E, Celis J-P, Rocha La. Simultaneous degradation by corrosion and wear of titanium in artificial saliva containing fluorides,. Wear. 2012;292\u2013293:82\u20138.","journal-title":"Wear"},{"issue":"12","key":"5879_CR17","doi-asserted-by":"crossref","first-page":"1470","DOI":"10.1177\/0022034510378428","volume":"89","author":"JCM Souza","year":"2010","unstructured":"Souza JCM, Henriques M, Oliveira R, Teughels W, Celis J-P, Rocha La. Biofilms inducing ultra-low friction on titanium. J Dent Res. 2010;89(12):1470\u20135.","journal-title":"J Dent Res"},{"issue":"4","key":"5879_CR18","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1080\/08927011003767985","volume":"26","author":"JCM Souza","year":"2010","unstructured":"Souza JCM, Henriques M, Oliveira R, Teughels W, Celis J-P, Rocha La. Do oral biofilms influence the wear and corrosion behavior of titanium? Biofouling. 2010;26(4):471\u20138.","journal-title":"Biofouling"},{"issue":"2","key":"5879_CR19","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1590\/S0103-64402010000200006","volume":"21","author":"AP Ricomini Filho","year":"2010","unstructured":"Ricomini Filho AP, Fernandes FSDF, Straioto FG, da Silva WJ, Del Bel Cury AA. Preload loss and bacterial penetration on different implant-abutment connection systems. Braz Dent J. 2010;21(2):123\u20139.","journal-title":"Braz Dent J"},{"issue":"15","key":"5879_CR20","doi-asserted-by":"crossref","first-page":"3121","DOI":"10.1088\/0022-3727\/39\/15\/S01","volume":"39","author":"D Landolt","year":"2006","unstructured":"Landolt D. Electrochemical and materials aspects of tribocorrosion systems,. J Phys D Appl Phys. 2006;39(15):3121\u20137.","journal-title":"J Phys D Appl Phys"},{"issue":"2","key":"5879_CR21","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1590\/0103-6440201600625","volume":"27","author":"JCM Souza","year":"2016","unstructured":"Souza JCM, Mota R, Sordi MB, Passoni BB, Benfatti CAM, Magini RS. Biofilm formation on different materials used in oral rehabilitation. Braz Dent J. 2016;27(2):141\u20137.","journal-title":"Braz Dent J"},{"issue":"1","key":"5879_CR22","doi-asserted-by":"crossref","first-page":"415","DOI":"10.11607\/jomi.2727","volume":"28","author":"JRP Jorge","year":"2013","unstructured":"Jorge JRP, Bar\u00e3o VAR, Delben JA, Assun\u00e7\u00e3o WG. The Role of implant\/abutment system on torque maintenance of retention screws and vertical misfit of implant-supported crowns before and after mechanical cycling. Int J Oral Maxillofac Implants. 2013;28(1):415\u2013421.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"6","key":"5879_CR23","doi-asserted-by":"crossref","first-page":"e631","DOI":"10.1097\/SCS.0b013e318270fe0e","volume":"23","author":"MB Ferreira","year":"2012","unstructured":"Ferreira MB, Delben JA, Bar\u00e3o VAR, Faverani LP, Dos Santos PH, Assun\u00e7\u00e3o WG. Evaluation of torque maintenance of abutment and cylinder screws with Morse taper implants. J Craniofac Surg. 2012;23(6):e631\u20134.","journal-title":"J Craniofac Surg"},{"key":"5879_CR24","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1067\/mpr.2001.115250","volume":"40","author":"SA Hoyer","year":"2001","unstructured":"Hoyer SA, Stanford CM, Buranadham S, Fridrich T, Wagner J, Gratton D. Dynamic fatigue properties of the dental implant-abutment interface: joint opening in wide-diameter versus standard-diameter hex-type implants. J Prosthet Dent. 2001;40:599\u2013607.","journal-title":"J Prosthet Dent"},{"key":"5879_CR25","unstructured":"Cruz HV, Souza JCM, Henriques M, Rocha LA.\u00a0Tribocorrosion and bio-tribocorrosion in the oral environment: the case of dental Implants. In: Davim JP, editor. Biomedical Tribology. Hauppauge, NY: Nova Science Publishers; 2011. p 1\u201333."},{"key":"5879_CR26","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1007\/s40735-015-0013-0","volume":"1","author":"JCM Souza","year":"2015","unstructured":"Souza JCM, Henriques M, Teughels W, Ponthiaux P, Celis J-P, Rocha LA. Wear and corrosion interactions on titanium in oral environment: literature review. J Bio- Tribo Corros. 2015;1:13.","journal-title":"J Bio- Tribo Corros"}],"container-title":["Journal of Materials Science: Materials in Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10856-017-5879-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10856-017-5879-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10856-017-5879-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2018,1,12]],"date-time":"2018-01-12T07:13:18Z","timestamp":1515741198000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10856-017-5879-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,3,20]]},"references-count":26,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2017,5]]}},"alternative-id":["5879"],"URL":"https:\/\/doi.org\/10.1007\/s10856-017-5879-6","relation":{},"ISSN":["0957-4530","1573-4838"],"issn-type":[{"value":"0957-4530","type":"print"},{"value":"1573-4838","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,3,20]]},"article-number":"65"}}