{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,6]],"date-time":"2025-10-06T18:50:15Z","timestamp":1759776615800},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2012,1,31]],"date-time":"2012-01-31T00:00:00Z","timestamp":1327968000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Exp Mech"],"published-print":{"date-parts":[[2012,11]]},"DOI":"10.1007\/s11340-012-9596-2","type":"journal-article","created":{"date-parts":[[2012,1,30]],"date-time":"2012-01-30T18:13:33Z","timestamp":1327947213000},"page":"1267-1274","source":"Crossref","is-referenced-by-count":10,"title":["Experimental Measurement and Numerical Validation of Bone Cement Mantle Strains of an In Vitro Hip Replacement Using Optical FBG Sensors"],"prefix":"10.1007","volume":"52","author":[{"given":"A.","family":"Ramos","sequence":"first","affiliation":[]},{"given":"M. W.","family":"Schiller","sequence":"additional","affiliation":[]},{"given":"I.","family":"Abe","sequence":"additional","affiliation":[]},{"given":"P. A.","family":"Lopes","sequence":"additional","affiliation":[]},{"given":"J. A.","family":"Sim\u00f5es","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2012,1,31]]},"reference":[{"key":"9596_CR1","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1016\/S0021-9290(01)00213-5","volume":"35","author":"J Stolk","year":"2002","unstructured":"Stolk J, Verdonschot N, Cristofolini L, Toni A, Huiskes RJ (2002) Finite element and experimental models of cemented hip joint reconstructions can produce similar bone and cement strains in pre-clinical tests. J Biomech 35:499","journal-title":"J Biomech"},{"key":"9596_CR2","doi-asserted-by":"crossref","first-page":"2602","DOI":"10.1016\/j.jbiomech.2009.06.037","volume":"42","author":"A Ramos","year":"2009","unstructured":"Ramos A, Sim\u00f5es JA (2009) The influence of cement mantle thickness and stem geometry on fatigue damage in two different cemented hip femoral prostheses. J Biomech 42:2602\u20132610","journal-title":"J Biomech"},{"key":"9596_CR3","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1302\/0301-620X.73B4.2071634","volume":"73B","author":"M Jasty","year":"1991","unstructured":"Jasty M, Maloney WJ, Bragdon CR, O\u2019Connor DO, Haire T, Harris WH (1991) The initiation of failure in cemented femoral components of hip arthroplasties. J Bone Joint Surg 73B:551","journal-title":"J Bone Joint Surg"},{"key":"9596_CR4","doi-asserted-by":"crossref","first-page":"1173","DOI":"10.1016\/S0021-9290(97)00082-1","volume":"30","author":"DA Fisher","year":"1997","unstructured":"Fisher DA, Tsang AC, Paydar N, Milions S, Turner CH (1997) Cement mantle thickness affects cement strains in total hip replacement. J Biomech 30:1173","journal-title":"J Biomech"},{"key":"9596_CR5","doi-asserted-by":"crossref","first-page":"1294","DOI":"10.1016\/j.engfailanal.2008.08.018","volume":"16","author":"A Ramos","year":"2009","unstructured":"Ramos A, Sim\u00f5es JA (2009) In vitro fatigue crack analysis of the Lubinus SPII cemented hip stem. Eng Fail Anal 16:1294","journal-title":"Eng Fail Anal"},{"key":"9596_CR6","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1002\/(SICI)1097-4636(1999)48:2<121::AID-JBM5>3.0.CO;2-P","volume":"48","author":"MM Vila","year":"1999","unstructured":"Vila MM, Ginebra MP, Planell JA (1999) Effect of porosity and environment on the mechanical behavior of acrylic bone cement modified with acrylonitrilebutadiene- styrene particles: I. Fracture toughness. J Biomed Mater Res Part B 48:121","journal-title":"J Biomed Mater Res Part B"},{"issue":"2","key":"9596_CR7","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1016\/j.jbiomech.2010.10.020","volume":"44","author":"D Waanders","year":"2011","unstructured":"Waanders D, Janssen D, Mann KA, Verdonschot N (2011) The behavior of the micro-mechanical cement-bone interface affects the cement failure in total hip replacement. J Biomech 44(2):228\u2013234","journal-title":"J Biomech"},{"key":"9596_CR8","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1302\/0301-620X.82B2 .9613","volume":"82B","author":"NA Ramaniraka","year":"2000","unstructured":"Ramaniraka NA, Rakotomanara LR, Leyvraz PF (2000) The fixation of the cemented femoral components. Effects of stem stiffness, cement thickness and the roughness of the cement bone surface. J Bone Joint Surg 82B:297","journal-title":"J Bone Joint Surg"},{"issue":"11","key":"9596_CR9","doi-asserted-by":"crossref","first-page":"1603","DOI":"10.1016\/S0021-9290(03)00191-X","volume":"36","author":"L Cristofolini","year":"2003","unstructured":"Cristofolini L, Teutonico AS, Monti L, Cappello A, Toni A (2003) Comparative in vitro study on the long term performance of cemented hip stems: validation of a protocol to discriminate between \"good\" and \"bad\" designs. J Biomech 36(11):1603\u20131615","journal-title":"J Biomech"},{"key":"9596_CR10","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.clinbiomech.2009.10.011","volume":"25","author":"A Completo","year":"2010","unstructured":"Completo A, Rego A, Foneseca F, Ramos A, Relvas C, Sim\u00f5es JA (2010) Biomechanical evaluation of proximal tibia behaviour with the use of femoral stems in revision TKA: an in vitro and finite element analysis. Clin Biomech 25:159\u2013165","journal-title":"Clin Biomech"},{"key":"9596_CR11","doi-asserted-by":"crossref","unstructured":"Ramos A, Ballu A, Mesnard M, Talaia P, Sim\u00f5es JA (2011) Numerical and experimental models of the mandible. Exp Mech (51);1053\u20131059","DOI":"10.1007\/s11340-010-9403-x"},{"key":"9596_CR12","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1243\/0309324001513982","volume":"35","author":"L Cristofolini","year":"2000","unstructured":"Cristofolini L, Viceconti M (2000) Development and validation of technique for strain measurement inside polymethyl mathacrylate. J Strain Anal 35:21","journal-title":"J Strain Anal"},{"key":"9596_CR13","volume-title":"Fiber bragg gratings\u2014fundamentals and applications in telecommunications and sensing","author":"A Othonos","year":"1999","unstructured":"Othonos A, Kalli K (1999) Fiber bragg gratings\u2014fundamentals and applications in telecommunications and sensing. Artech House, Boston"},{"key":"9596_CR14","unstructured":"Whelan MP, Kenny RP, Cavalli C, Lennon AB, Prendergast PJ (2000) Application of optical fibre bragg grating sensors to the study of PMMA curing. Presented at the 12th Conference of the European Society of Biomechanics, Royal Academy of Medicine in Ireland; Dublin, IR"},{"issue":"5","key":"9596_CR15","doi-asserted-by":"crossref","first-page":"1841","DOI":"10.1016\/j.matdes.2008.07.035","volume":"30","author":"C Frias","year":"2008","unstructured":"Frias C, Fraz\u00e3o O, Tavares S, Vieira A, Marques AT, Sim\u00f5es J (2008) Mechanical characterization of bone cement using fibber bragg grating sensors. Mater Des 30(5):1841\u20131844","journal-title":"Mater Des"},{"issue":"3","key":"9596_CR16","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1007\/s11340-007-9034-z","volume":"47","author":"PM Talaia","year":"2007","unstructured":"Talaia PM, Ramos A, Sim\u00f5es JA (2007) Plated and intact femur strains in fracture fixation using fiber bragg gratings and strain gauges. Exp Mech 47(3):355\u2013363","journal-title":"Exp Mech"},{"key":"9596_CR17","doi-asserted-by":"crossref","first-page":"833","DOI":"10.1016\/S1350-4533(03)00120-6","volume":"25","author":"AB Lennon","year":"2004","unstructured":"Lennon AB, McCormack BAO, Prendergast PJ (2004) The relationship between cement fatigue damage and implant surface finish in proximal femoral prostheses. Med Eng Phys 25:833","journal-title":"Med Eng Phys"},{"key":"9596_CR18","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1016\/S0268-0033(03)00072-X","volume":"18","author":"V Waide","year":"2003","unstructured":"Waide V, Cristofolini L, Stolk J, Verdonschot N, Toni A (2003) Experimental investigation of bone remodeling using composite femurs. Clin Biomech 18:523","journal-title":"Clin Biomech"},{"key":"9596_CR19","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/S0021-9290(03)00258-6","volume":"37","author":"W Waide","year":"2004","unstructured":"Waide W, Cristofolini L, Stolk J, Verdonschot N, Boogaard GJ, Toni A (2004) Modeling the fibrous tissue layer in cemented hip replacements: experimental and finite element methods. J Biomech 37:13\u201326","journal-title":"J Biomech"},{"key":"9596_CR20","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1016\/0021-9290(95)00084-4","volume":"29","author":"L Cristofolini","year":"1996","unstructured":"Cristofolini L, Viceconti M, Cappello A, Toni A (1996) Mechanical validation of whole bone composite femur models. J Biomech 29:525\u2013535","journal-title":"J Biomech"},{"issue":"0","key":"9596_CR21","first-page":"313","volume":"33","author":"A Ramos","year":"2011","unstructured":"Ramos A, Completo A, Relvas C, Sim\u00f5es JA (2011) Design process of a novel cemented hip femoral stem concept. Mater Des 33(0):313\u2013321","journal-title":"Mater Des"},{"issue":"9","key":"9596_CR22","doi-asserted-by":"crossref","first-page":"2021","DOI":"10.1016\/j.jbiomech.2008.03.041","volume":"41","author":"S Gravius","year":"2008","unstructured":"Gravius S, Wirtz DC, Siebert CH, Andereya ST, Mueller-Rath R, Maus U, Mumme T (2008) In vitro interface and cement mantle analysis of different femur stem designs. J Biomech 41(9):2021\u20132028","journal-title":"J Biomech"},{"issue":"10","key":"9596_CR23","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1016\/S0142-1123(00)00056-6","volume":"22","author":"M Baleani","year":"2000","unstructured":"Baleani M, Viceconti M, Muccini R, Ansaloni M (2000) Endurance verification of custom-made hip prostheses. Int J Fatig 22(10):865\u2013871","journal-title":"Int J Fatig"},{"issue":"5","key":"9596_CR24","doi-asserted-by":"crossref","first-page":"894","DOI":"10.1016\/j.ijfatigue.2008.10.005","volume":"31","author":"P Heidi-Lynn","year":"2009","unstructured":"Heidi-Lynn P, Maja B, Urs PW (2009) Hip stem fatigue test prediction. Int J Fatig 31(5):894\u2013905","journal-title":"Int J Fatig"},{"key":"9596_CR25","doi-asserted-by":"crossref","first-page":"916","DOI":"10.1016\/j.medengphy.2005.12.006","volume":"28","author":"A Ramos","year":"2006","unstructured":"Ramos A, Sim\u00f5es JA (2006) Tetrahedral versus hexahedral finite elements in numerical modeling of the intact femur. Med Eng Phys 28:916\u2013924","journal-title":"Med Eng Phys"},{"issue":"Suppl. 1","key":"9596_CR26","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1016\/S0021-9290(98)80332-1","volume":"31","author":"J Stolk","year":"1998","unstructured":"Stolk J, Verdonschot N, Huiskes R (1998) Sensitivity of failure criteria of cemented total hip replacements to finite element mesh density. J Biomech 31(suppl 1):165","journal-title":"J Biomech"},{"issue":"9","key":"9596_CR27","doi-asserted-by":"crossref","first-page":"1206","DOI":"10.1002\/jor.20639","volume":"26","author":"PH Hsieh","year":"2008","unstructured":"Hsieh PH, Tai CL, Liaw JW, Chang YH (2008) Thermal damage potential during hip resurfacing in osteonecrosis of the femoral head: an experimental study. J Orthop Res 26(9):1206\u20131209","journal-title":"J Orthop Res"},{"key":"9596_CR28","first-page":"163","volume-title":"Third international symposium on computer methods in biomechanics and biomedical engineering","author":"GR Starke","year":"1997","unstructured":"Starke GR, Birnie C, van den Blink PA (1997) Numerical modelling of cement polymerisation and thermal bone necrosis. In: Middleton J, Jones MN, Pande GN (eds) Third international symposium on computer methods in biomechanics and biomedical engineering. Gordon and Breach, London, pp 163\u2013172"},{"issue":"4","key":"9596_CR29","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1016\/j.clinbiomech.2006.09.001","volume":"22","author":"L Cristofolini","year":"2007","unstructured":"Cristofolini L, Erani P, Savigni P, Otto Thies TG, Viceconti M (2007) Increased long-term failure risk associated with excessively thin cement mantle in cemented hip arthroplasty: a comparative in vitro study. Clin Biomech 22(4):410\u2013421","journal-title":"Clin Biomech"},{"issue":"12","key":"9596_CR30","doi-asserted-by":"crossref","first-page":"2605","DOI":"10.1016\/j.jbiomech.2008.06.030","volume":"41","author":"N Nuno","year":"2008","unstructured":"Nuno N, Madrala A, Plamondon D (2008) Measurement of transient and residual stresses during polymerization of bone cement for cemented hip implants. J Biomech 41(12):2605\u20132611","journal-title":"J Biomech"},{"key":"9596_CR31","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1097\/00003086-197203000-00052","volume":"83","author":"CA Homsy","year":"1972","unstructured":"Homsy CA, Tullos HS, Anderson MS, Differant NM, King JW (1972) Some physiological aspect of prosthesis stabilization with acrylic polymer. Clin Orthop Relat Res 83:317\u2013328","journal-title":"Clin Orthop Relat Res"},{"key":"9596_CR32","doi-asserted-by":"crossref","first-page":"149","DOI":"10.2106\/00004623-197355010-00015","volume":"55-A","author":"JR Meyer","year":"1973","unstructured":"Meyer JR, Lautenschlager EP, Moore EK (1973) On the setting properties of acrylic bone cement. J Bone Joint Surg Br 55-A:149\u2013156","journal-title":"J Bone Joint Surg Br"},{"issue":"3","key":"9596_CR33","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1016\/S0021-9290(01)00216-0","volume":"35","author":"AB Lennon","year":"2002","unstructured":"Lennon AB, Prendergast PJ (2002) Residual stress due to curing can initiate damage in porous bone cement: experimental and theoretical evidence. J Biomech 35(3):311\u2013321","journal-title":"J Biomech"},{"key":"9596_CR34","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1002\/jor.1100100116","volume":"10","author":"TP Harrigan","year":"1992","unstructured":"Harrigan TP, Kareh JA, O\u2019Connor DO, Burke DW, Harris WH (1992) A finite element study of the initiation of failure of fixation in cemented femoral total hip components. J Orthop Res 10:134\u2013144","journal-title":"J Orthop Res"}],"container-title":["Experimental Mechanics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11340-012-9596-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11340-012-9596-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11340-012-9596-2","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,23]],"date-time":"2019-06-23T01:46:08Z","timestamp":1561254368000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11340-012-9596-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,1,31]]},"references-count":34,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2012,11]]}},"alternative-id":["9596"],"URL":"https:\/\/doi.org\/10.1007\/s11340-012-9596-2","relation":{},"ISSN":["0014-4851","1741-2765"],"issn-type":[{"value":"0014-4851","type":"print"},{"value":"1741-2765","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,1,31]]}}}