{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T19:40:21Z","timestamp":1773258021478,"version":"3.50.1"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2019,6,29]],"date-time":"2019-06-29T00:00:00Z","timestamp":1561766400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,6,29]],"date-time":"2019-06-29T00:00:00Z","timestamp":1561766400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100001871","name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologi","doi-asserted-by":"publisher","award":["PTDC\/EEIAUT\/3024\/2014"],"award-info":[{"award-number":["PTDC\/EEIAUT\/3024\/2014"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100007601","name":"Horizon 2020","doi-asserted-by":"publisher","award":["766850"],"award-info":[{"award-number":["766850"]}],"id":[{"id":"10.13039\/501100007601","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2019,9]]},"DOI":"10.1007\/s11548-019-02021-0","type":"journal-article","created":{"date-parts":[[2019,6,29]],"date-time":"2019-06-29T14:02:38Z","timestamp":1561816958000},"page":"1529-1539","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":22,"title":["Video-based computer navigation in knee arthroscopy for patient-specific ACL reconstruction"],"prefix":"10.1007","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2884-5000","authenticated-orcid":false,"given":"Carolina","family":"Raposo","sequence":"first","affiliation":[]},{"given":"Jo\u00e3o P.","family":"Barreto","sequence":"additional","affiliation":[]},{"given":"Crist\u00f3v\u00e3o","family":"Sousa","sequence":"additional","affiliation":[]},{"given":"Luis","family":"Ribeiro","sequence":"additional","affiliation":[]},{"given":"Rui","family":"Melo","sequence":"additional","affiliation":[]},{"given":"Jo\u00e3o Pedro","family":"Oliveira","sequence":"additional","affiliation":[]},{"given":"Pedro","family":"Marques","sequence":"additional","affiliation":[]},{"given":"Fernando","family":"Fonseca","sequence":"additional","affiliation":[]},{"given":"David","family":"Barrett","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2019,6,29]]},"reference":[{"issue":"5","key":"2021_CR1","doi-asserted-by":"publisher","first-page":"833","DOI":"10.1302\/0301-620X.73B5.1894677","volume":"73","author":"DS Barrett","year":"1991","unstructured":"Barrett DS (1991) Proprioception and function after anterior cruciate reconstruction. J Bone Joint Surg Br 73(5):833\u2013837","journal-title":"J Bone Joint Surg Br"},{"key":"2021_CR2","doi-asserted-by":"crossref","unstructured":"Belhaoua A, Kornmann A, Radoux J (2014) Accuracy analysis of an augmented reality system. In: ICSP","DOI":"10.1109\/ICOSP.2014.7015184"},{"issue":"2","key":"2021_CR3","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1109\/34.121791","volume":"14","author":"PJ Besl","year":"1992","unstructured":"Besl PJ, McKay ND (1992) A method for registration of 3-d shapes. IEEE Trans Pattern Anal Mach Intell 14(2):239\u2013256","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"issue":"2","key":"2021_CR4","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1007\/s00264-012-1772-6","volume":"37","author":"CH Brown","year":"2013","unstructured":"Brown CH, Spalding T, Robb C (2013) Medial portal technique for single-bundle anatomical anterior cruciate ligament (ACL) reconstruction. Int Orthop 37(2):253\u2013269","journal-title":"Int Orthop"},{"issue":"5","key":"2021_CR5","doi-asserted-by":"publisher","first-page":"e1933","DOI":"10.1002\/rcs.1933","volume":"14","author":"WJ Cho","year":"2018","unstructured":"Cho WJ, Kim JM, Kim DE, Lee JG, Park JW, Han YH, Seo HG (2018) Accuracy of the femoral tunnel position in robot-assisted anterior cruciate ligament reconstruction using a magnetic resonance imaging-based navigation system: a preliminary report. Int J Med Robot Comput Assist Surg 14(5):e1933","journal-title":"Int J Med Robot Comput Assist Surg"},{"issue":"1","key":"2021_CR6","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1002\/(SICI)1522-712X(1995)1:1<59::AID-IGS9>3.0.CO;2-L","volume":"1","author":"V Dessenne","year":"1995","unstructured":"Dessenne V, Lavall\u00e9e S, Julliard R, Orti R, Martelli S, Cinquin P (1995) Computer-assisted knee anterior cruciate ligament reconstruction: first clinical tests. J Image Guided Surg 1(1):59\u201364","journal-title":"J Image Guided Surg"},{"issue":"6","key":"2021_CR7","doi-asserted-by":"publisher","first-page":"1418","DOI":"10.2106\/JBJS.I.00654","volume":"92","author":"B Forsythe","year":"2010","unstructured":"Forsythe B, Kopf S, Wong AK, Martins CAQ, Anderst W, Tashman S, Fu FH (2010) The location of femoral and tibial tunnels in anatomic double-bundle anterior cruciate ligament reconstruction analyzed by three-dimensional computed tomography models. J Bone Joint Surg Am 92(6):1418\u20131426","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"2021_CR8","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1177\/0363546517730577","volume":"46","author":"A Hart","year":"2018","unstructured":"Hart A, Sivakumaran T, Burman M, Powell T, Martineau PA (2018) A prospective evaluation of femoral tunnel placement for anatomic anterior cruciate ligament reconstruction using 3-dimensional magnetic resonance imaging. AM J Sports Med 46(1):192\u2013199","journal-title":"AM J Sports Med"},{"issue":"2","key":"2021_CR9","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1007\/s11548-006-0044-6","volume":"1","author":"P Jannin","year":"2006","unstructured":"Jannin P, Grova C, Calvin R, Maurer J (2006) Model for defining and reporting reference-based validation protocols in medical image processing. Int J CARS 1(2):63\u201373","journal-title":"Int J CARS"},{"issue":"5\u20136","key":"2021_CR10","first-page":"245","volume":"13","author":"JM Lavest","year":"2003","unstructured":"Lavest JM, Rives G, Lapreste JT (2003) Dry camera calibration for underwater applications. MVA 13(5\u20136):245\u2013253","journal-title":"MVA"},{"key":"2021_CR11","doi-asserted-by":"crossref","unstructured":"Louren\u00e7o M, Barreto JP, Fonseca F, Ferreira H, Duarte RM, Correia-Pinto J (2014) Continuous zoom calibration by tracking salient points in endoscopic video. In: MICCAI","DOI":"10.1007\/978-3-319-10404-1_57"},{"key":"2021_CR12","doi-asserted-by":"crossref","unstructured":"Mahmoud N, Cirauqui I, Hostettler A, Doignon C, Soler L, Marescaux J, Montiel JMM (2016) Orbslam-based endoscope tracking and 3d reconstruction. In: CARE@MICCAI","DOI":"10.1007\/978-3-319-54057-3_7"},{"issue":"8","key":"2021_CR13","doi-asserted-by":"publisher","first-page":"974","DOI":"10.1016\/j.media.2013.04.003","volume":"17","author":"L Maier-Hein","year":"2013","unstructured":"Maier-Hein L, Mountney P, Bartoli A, Elhawary H, Elson D, Groch A, Kolb A, Rodrigues M, Sorger J, Speidel S, Stoyanov D (2013) Optical techniques for 3d surface reconstruction in computer-assisted laparoscopic surgery. Med Image Anal 17(8):974\u2013996","journal-title":"Med Image Anal"},{"issue":"4","key":"2021_CR14","doi-asserted-by":"publisher","first-page":"1026","DOI":"10.1007\/s00167-013-2831-2","volume":"23","author":"J Margier","year":"2014","unstructured":"Margier J, Tchouda SD, Banihachemi JJ, Bosson JL, Plaweski S (2014) Computer-assisted navigation in acl reconstruction is attractive but not yet cost efficient. Knee Surg Sports Traumatol Arthrosc 23(4):1026\u20131034","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"6","key":"2021_CR15","doi-asserted-by":"publisher","first-page":"1352","DOI":"10.1109\/TRO.2008.2007941","volume":"24","author":"C Mei","year":"2008","unstructured":"Mei C, Benhimane S, Malis E, Rives P (2008) Efficient homography-based tracking and 3-d reconstruction for single-viewpoint sensors. IEEE Trans Robot 24(6):1352\u20131364","journal-title":"IEEE Trans Robot"},{"issue":"3","key":"2021_CR16","doi-asserted-by":"publisher","first-page":"634","DOI":"10.1109\/TBME.2011.2177268","volume":"59","author":"R Melo","year":"2012","unstructured":"Melo R, Barreto JP, Falcao G (2012) A new solution for camera calibration and real-time image distortion correction in medical endoscopy-initial technical evaluation. IEEE Trans Biomed Eng 59(3):634\u2013644","journal-title":"IEEE Trans Biomed Eng"},{"issue":"5","key":"2021_CR17","doi-asserted-by":"publisher","first-page":"1147","DOI":"10.1109\/TRO.2015.2463671","volume":"31","author":"R Mur-Artal","year":"2015","unstructured":"Mur-Artal R, Montiel JMM, Tard\u00f3s JD (2015) ORB-SLAM: a versatile and accurate monocular SLAM system. IEEE Trans Robot 31(5):1147\u20131163. \n                    https:\/\/doi.org\/10.1109\/TRO.2015.2463671","journal-title":"IEEE Trans Robot"},{"issue":"5","key":"2021_CR18","doi-asserted-by":"publisher","first-page":"279","DOI":"10.3109\/10929080109146093","volume":"6","author":"F Picard","year":"2001","unstructured":"Picard F, DiGioia AM, Moody J, Martinek V, Fu F, Rytel M, Nikou C, LaBarca RS, Jaramaz B (2001) Accuracy in tunnel placement for acl reconstruction. comparison of traditional arthroscopic and computer-assisted navigation techniques. Comput Aided Surg: Off J Int Soc Comput Aided Surg 6(5):279\u201389","journal-title":"Comput Aided Surg: Off J Int Soc Comput Aided Surg"},{"key":"2021_CR19","doi-asserted-by":"crossref","unstructured":"Plaweski S, Pearle A, Granchi C, Julliard R (2007) Praxim ACL navigation system using bone morphing. In: Navigation and MIS in orthopedic surgery","DOI":"10.1007\/978-3-540-36691-1_40"},{"key":"2021_CR20","doi-asserted-by":"crossref","unstructured":"Plaweski S, Schlatterer B, Saragaglia D, Computer Assisted Orthopedic Surgery - France (CAOS - France) (2015) The role of computer assisted navigation in revision surgery for failed anterior cruciate ligament reconstruction of the knee: a continuous series of 52 cases. Orthop Traumatol Surg Res 101(6 Suppl):S227\u2013S231","DOI":"10.1016\/j.otsr.2015.07.003"},{"key":"2021_CR21","doi-asserted-by":"crossref","unstructured":"Raposo C, Barreto JP (2018) 3d registration of curves and surfaces using local differential information. In: CVPR","DOI":"10.1109\/CVPR.2018.00969"},{"key":"2021_CR22","doi-asserted-by":"crossref","unstructured":"Raposo C, Sousa C, Ribeiro LL, Melo R, Barreto JP, Oliveira J, Marques P, Fonseca F (2018) Video-based computer aided arthroscopy for patient specific reconstruction of the anterior cruciate ligament. In: MICCAI","DOI":"10.1007\/978-3-030-00937-3_15"},{"key":"2021_CR23","unstructured":"Samitier G, Marcano AI, Alentorn-Geli E, Cugat R, Farmer KW, Moser MW (2015) Failure of anterior cruciate ligament reconstruction. In: ABJS"},{"issue":"3","key":"2021_CR24","first-page":"158","volume":"2","author":"R Treuting","year":"2000","unstructured":"Treuting R (2000) Minimally invasive orthopedic surgery: arthroscopy. Ochsner J 2(3):158\u2013163","journal-title":"Ochsner J"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-019-02021-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-019-02021-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-019-02021-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,6,27]],"date-time":"2020-06-27T23:21:51Z","timestamp":1593300111000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-019-02021-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6,29]]},"references-count":24,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2019,9]]}},"alternative-id":["2021"],"URL":"https:\/\/doi.org\/10.1007\/s11548-019-02021-0","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,6,29]]},"assertion":[{"value":"7 February 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 June 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 June 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All studies involving post-mortem subjects followed the procedures for informed consent that are described in the Declaration of Helsinki.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}