{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,14]],"date-time":"2026-03-14T19:03:03Z","timestamp":1773514983548,"version":"3.50.1"},"reference-count":145,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2025,4,24]],"date-time":"2025-04-24T00:00:00Z","timestamp":1745452800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,4,24]],"date-time":"2025-04-24T00:00:00Z","timestamp":1745452800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001871","name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia","doi-asserted-by":"publisher","award":["2022.06207.PTDC"],"award-info":[{"award-number":["2022.06207.PTDC"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001871","name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia","doi-asserted-by":"publisher","award":["PTDC\/EEI-EEE\/2846\/2021"],"award-info":[{"award-number":["PTDC\/EEI-EEE\/2846\/2021"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100008814","name":"Universidade do Minho","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100008814","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Biophys Rev"],"published-print":{"date-parts":[[2025,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Microneedles (MN) technology has emerged as a transformative tool within the biomedical field, offering innovative solutions to challenges in drug delivery, diagnostics, and therapeutic applications. This review article provides an in-depth exploration of the diverse perspectives and applications of MNs, shedding light on their pivotal role in shaping the future of biomedical research and clinical practice. It\u00a0begins by elucidating the fundamental principles of MNs:\u00a0design, fabrication techniques, and materials, highlighting their capacity for minimally invasive access to the skin and underlying tissues. These attributes have driven advancements in transdermal drug delivery, facilitating precise and controlled administration of therapeutics, vaccines, and biologics, thus improving patient compliance and treatment outcomes. Furthermore, this review investigates the growing range of applications for MNs, including biomarker extraction, interstitial fluid (ISF) analysis, and continuous glucose monitoring. MNs enable real-time and minimally invasive monitoring of biochemical markers and have the potential to revolutionize disease diagnostics, personalized medicine, and wellness monitoring. Their compatibility with microfluidic systems further enhances their potential for point-of-care testing. This review serves as a comprehensive guide, highlighting the breadth of opportunities and challenges in leveraging MNs to improve healthcare outcomes and emphasizing the need for continued research and development in this dynamic field.<\/jats:p>","DOI":"10.1007\/s12551-025-01317-7","type":"journal-article","created":{"date-parts":[[2025,4,24]],"date-time":"2025-04-24T09:39:12Z","timestamp":1745487552000},"page":"909-928","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":22,"title":["Recent advances and perspectives of MicroNeedles for biomedical applications"],"prefix":"10.1007","volume":"17","author":[{"given":"Renata Faria","family":"Maia","sequence":"first","affiliation":[]},{"given":"Pedro","family":"Machado","sequence":"additional","affiliation":[]},{"given":"Raquel O.","family":"Rodrigues","sequence":"additional","affiliation":[]},{"given":"Vera","family":"Faustino","sequence":"additional","affiliation":[]},{"given":"Helmut","family":"Sch\u00fctte","sequence":"additional","affiliation":[]},{"given":"Stefan","family":"Gassmann","sequence":"additional","affiliation":[]},{"given":"Rui A.","family":"Lima","sequence":"additional","affiliation":[]},{"given":"Gra\u00e7a","family":"Minas","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2025,4,24]]},"reference":[{"key":"1317_CR1","doi-asserted-by":"publisher","unstructured":"Aldawood, F.K. et al. (2021). A Comprehensive Review of Microneedles: Types, Materials, Processes, Characterizations and Applications. Polymers. https:\/\/doi.org\/10.3390\/polym13162815.","DOI":"10.3390\/polym13162815"},{"key":"1317_CR2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijpharm.2025.125387","author":"H Alfalasi","year":"2025","unstructured":"Alfalasi H et al (2025) Hydrogel-based microneedles for the delivery of catalase protein. Int J Pharm. https:\/\/doi.org\/10.1016\/j.ijpharm.2025.125387","journal-title":"Int J Pharm"},{"key":"1317_CR3","doi-asserted-by":"publisher","DOI":"10.1016\/j.jconrel.2020.12.019","author":"H Amani","year":"2021","unstructured":"Amani H et al (2021) Microneedles for painless transdermal immunotherapeutic applications. J Control Release. https:\/\/doi.org\/10.1016\/j.jconrel.2020.12.019","journal-title":"J Control Release"},{"key":"1317_CR4","doi-asserted-by":"publisher","DOI":"10.1007\/S11095-009-0019-8","author":"M Ameri","year":"2010","unstructured":"Ameri M et al (2010) Parathyroid hormone PTH(1\u201334) formulation that enables uniform coating on a novel transdermal microprojection delivery system. Pharm Res. https:\/\/doi.org\/10.1007\/S11095-009-0019-8","journal-title":"Pharm Res"},{"key":"1317_CR5","doi-asserted-by":"publisher","DOI":"10.1021\/acsami.9b22425","author":"U Angkawinitwong","year":"2020","unstructured":"Angkawinitwong U et al (2020) A Novel Transdermal Protein Delivery Strategy via Electrohydrodynamic Coating of PLGA Microparticles onto Microneedles. ACS Appl Mater Interfaces. https:\/\/doi.org\/10.1021\/acsami.9b22425","journal-title":"ACS Appl Mater Interfaces"},{"key":"1317_CR6","doi-asserted-by":"crossref","unstructured":"Aoyagi, S. et al. (2007). Laser fabrication of high aspect ratio thin holes on biodegradable polymer and its application to a microneedle. Sensors and Actuators A: Physical.","DOI":"10.1016\/j.sna.2006.11.022"},{"key":"1317_CR7","doi-asserted-by":"publisher","unstructured":"Au, A.K. et al. (2016). 3D-Printed Microfluidics. Angewandte Chemie (International ed. in English). https:\/\/doi.org\/10.1002\/ANIE.201504382.","DOI":"10.1002\/ANIE.201504382"},{"key":"1317_CR8","doi-asserted-by":"publisher","DOI":"10.3390\/MI12111321","author":"M Avcil","year":"2021","unstructured":"Avcil M, e \u00c7elik, A. (2021) Microneedles in Drug Delivery: Progress and Challenges. Micromachines. https:\/\/doi.org\/10.3390\/MI12111321","journal-title":"Micromachines"},{"key":"1317_CR9","doi-asserted-by":"publisher","DOI":"10.1149\/2.0141510JSS\/XML","author":"C Barrett","year":"2015","unstructured":"Barrett C et al (2015) Development of Low Cost Rapid Fabrication of Sharp Polymer Microneedles for In Vivo Glucose Biosensing Applications. ECS Journal of Solid State Science and Technology. https:\/\/doi.org\/10.1149\/2.0141510JSS\/XML","journal-title":"ECS Journal of Solid State Science and Technology"},{"key":"1317_CR10","doi-asserted-by":"publisher","DOI":"10.1109\/SENSORS43011.2019.8956509","author":"C Barrett","year":"2019","unstructured":"Barrett C et al (2019) Novel Surface Modified Polymer Microneedle based Biosensors for Interstitial Fluid Glucose Detection. Proceedings of IEEE Sensors. https:\/\/doi.org\/10.1109\/SENSORS43011.2019.8956509","journal-title":"Proceedings of IEEE Sensors"},{"key":"1317_CR11","doi-asserted-by":"publisher","DOI":"10.1007\/S11095-013-1137-X","author":"B Bediz","year":"2014","unstructured":"Bediz B et al (2014) Dissolvable microneedle arrays for intradermal delivery of biologics: fabrication and application. Pharm Res. https:\/\/doi.org\/10.1007\/S11095-013-1137-X","journal-title":"Pharm Res"},{"key":"1317_CR12","doi-asserted-by":"publisher","DOI":"10.1007\/s10856-021-06559-x","author":"RS Bhadale","year":"2021","unstructured":"Bhadale RS, e Londhe, V.Y. (2021) A systematic review of carbohydrate-based microneedles: current status and future prospects. J Mater Sci - Mater Med. https:\/\/doi.org\/10.1007\/s10856-021-06559-x","journal-title":"J Mater Sci - Mater Med"},{"key":"1317_CR13","doi-asserted-by":"publisher","DOI":"10.1016\/j.bioadv.2023.213659","author":"SI Bisgaard","year":"2023","unstructured":"Bisgaard SI et al (2023) Dermal tissue penetration of in-plane silicon microneedles evaluated in skin-simulating hydrogel, rat skin and porcine skin. Biomaterials Advances. https:\/\/doi.org\/10.1016\/j.bioadv.2023.213659","journal-title":"Biomaterials Advances"},{"key":"1317_CR14","doi-asserted-by":"publisher","DOI":"10.1039\/D0LC00567C","author":"CJW Bolton","year":"2020","unstructured":"Bolton CJW et al (2020) Hollow silicon microneedle fabrication using advanced plasma etch technologies for applications in transdermal drug delivery. Lab Chip. https:\/\/doi.org\/10.1039\/D0LC00567C","journal-title":"Lab Chip"},{"key":"1317_CR15","doi-asserted-by":"publisher","DOI":"10.1039\/C4TB00764F","author":"B Cai","year":"2014","unstructured":"Cai B et al (2014) Self-setting bioceramic microscopic protrusions for transdermal drug delivery. Journal of Materials Chemistry B. https:\/\/doi.org\/10.1039\/C4TB00764F","journal-title":"Journal of Materials Chemistry B"},{"key":"1317_CR16","doi-asserted-by":"publisher","DOI":"10.1016\/J.EJPB.2015.06.016","author":"B Cai","year":"2015","unstructured":"Cai B et al (2015) Bioceramic microneedles with flexible and self-swelling substrate. Eur J Pharm Biopharm. https:\/\/doi.org\/10.1016\/J.EJPB.2015.06.016","journal-title":"Eur J Pharm Biopharm"},{"key":"1317_CR17","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijpharm.2021.120455","author":"\u00c1 C\u00e1rcamo-Mart\u00ednez","year":"2021","unstructured":"C\u00e1rcamo-Mart\u00ednez \u00c1 et al (2021) Hollow microneedles: A perspective in biomedical applications. Int J Pharm. https:\/\/doi.org\/10.1016\/j.ijpharm.2021.120455","journal-title":"Int J Pharm"},{"key":"1317_CR18","doi-asserted-by":"publisher","DOI":"10.1063\/1.2936856\/376368","author":"S Chakraborty","year":"2008","unstructured":"Chakraborty S, e Tsuchiya, K. (2008) Development and fluidic simulation of microneedles for painless pathological interfacing with living systems. J Appl Phys. https:\/\/doi.org\/10.1063\/1.2936856\/376368","journal-title":"J Appl Phys"},{"key":"1317_CR19","doi-asserted-by":"publisher","DOI":"10.1007\/S10404-014-1542-4\/FIGURES\/6","author":"HN Chan","year":"2015","unstructured":"Chan HN et al (2015) Direct, one-step molding of 3D-printed structures for convenient fabrication of truly 3D PDMS microfluidic chips. Microfluid Nanofluid. https:\/\/doi.org\/10.1007\/S10404-014-1542-4\/FIGURES\/6","journal-title":"Microfluid Nanofluid"},{"key":"1317_CR20","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmapro.2020.02.024","author":"K-T Chang","year":"2020","unstructured":"Chang K-T et al (2020) Optimal design and fabrication of a microneedle arrays patch. J Manuf Process. https:\/\/doi.org\/10.1016\/j.jmapro.2020.02.024","journal-title":"J Manuf Process"},{"key":"1317_CR21","doi-asserted-by":"publisher","DOI":"10.3109\/03639045.2013.873447","author":"J Chen","year":"2015","unstructured":"Chen J et al (2015) Controllable coating of microneedles for transdermal drug delivery. Drug Dev Ind Pharm. https:\/\/doi.org\/10.3109\/03639045.2013.873447","journal-title":"Drug Dev Ind Pharm"},{"key":"1317_CR22","doi-asserted-by":"publisher","DOI":"10.1016\/j.jconrel.2018.08.042","author":"X Chen","year":"2018","unstructured":"Chen X et al (2018) Preparation, properties and challenges of the microneedles-based insulin delivery system. J Control Release. https:\/\/doi.org\/10.1016\/j.jconrel.2018.08.042","journal-title":"J Control Release"},{"key":"1317_CR23","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2023.09.010","author":"BZ Chen","year":"2023","unstructured":"Chen BZ et al (2023) Functional insulin aspart\/insulin degludec-based microneedles for promoting postprandial glycemic control. Acta Biomater. https:\/\/doi.org\/10.1016\/j.actbio.2023.09.010","journal-title":"Acta Biomater"},{"key":"1317_CR24","doi-asserted-by":"publisher","DOI":"10.1021\/acssensors.7b00350","author":"C Chiappini","year":"2017","unstructured":"Chiappini C (2017) Nanoneedle-Based Sensing in Biological Systems. ACS Sensors. https:\/\/doi.org\/10.1021\/acssensors.7b00350","journal-title":"ACS Sensors"},{"key":"1317_CR25","doi-asserted-by":"publisher","DOI":"10.1038\/nmat4249","author":"C Chiappini","year":"2015","unstructured":"Chiappini C et al (2015) Biodegradable silicon nanoneedles delivering nucleic acids intracellularly induce localized in vivo neovascularization. Nat Mater. https:\/\/doi.org\/10.1038\/nmat4249","journal-title":"Nat Mater"},{"key":"1317_CR26","doi-asserted-by":"publisher","DOI":"10.1007\/S00604-018-2770-1\/FIGURES\/6","author":"SR Chinnadayyala","year":"2018","unstructured":"Chinnadayyala SR et al (2018) Nonenzymatic determination of glucose at near neutral pH values based on the use of nafion and platinum black coated microneedle electrode array. Microchim Acta. https:\/\/doi.org\/10.1007\/S00604-018-2770-1\/FIGURES\/6","journal-title":"Microchim Acta"},{"key":"1317_CR27","doi-asserted-by":"publisher","DOI":"10.1016\/j.vaccine.2023.05.005","author":"Y Choi","year":"2023","unstructured":"Choi Y et al (2023) Hepatitis B vaccine delivered by microneedle patch: Immunogenicity in mice and rhesus macaques. Vaccine. https:\/\/doi.org\/10.1016\/j.vaccine.2023.05.005","journal-title":"Vaccine"},{"key":"1317_CR28","doi-asserted-by":"publisher","DOI":"10.1016\/J.SNA.2013.09.026","author":"B Chua","year":"2013","unstructured":"Chua B et al (2013) Effect of microneedles shape on skin penetration and minimally invasive continuous glucose monitoring in vivo. Sens Actuators, A. https:\/\/doi.org\/10.1016\/J.SNA.2013.09.026","journal-title":"Sens Actuators, A"},{"key":"1317_CR29","doi-asserted-by":"publisher","DOI":"10.1016\/J.BIOMATERIALS.2016.01.015","author":"JW Coffey","year":"2016","unstructured":"Coffey JW et al (2016) Dynamic application of microprojection arrays to skin induces circulating protein extravasation for enhanced biomarker capture and detection. Biomaterials. https:\/\/doi.org\/10.1016\/J.BIOMATERIALS.2016.01.015","journal-title":"Biomaterials"},{"key":"1317_CR30","doi-asserted-by":"publisher","DOI":"10.1002\/adtp.201900036","author":"P Dardano","year":"2019","unstructured":"Dardano P et al (2019) Polymeric Microneedle Arrays: Versatile Tools for an Innovative Approach to Drug Administration. Advanced Therapeutics. https:\/\/doi.org\/10.1002\/adtp.201900036","journal-title":"Advanced Therapeutics"},{"key":"1317_CR31","doi-asserted-by":"publisher","DOI":"10.3390\/POLYM13040520","author":"P Dardano","year":"2021","unstructured":"Dardano P et al (2021) One-Shot Fabrication of Polymeric Hollow Microneedles by Standard Photolithography. Polymers. https:\/\/doi.org\/10.3390\/POLYM13040520","journal-title":"Polymers"},{"key":"1317_CR32","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2005.845240","author":"SP Davis","year":"2005","unstructured":"Davis SP et al (2005) Hollow metal microneedles for insulin delivery to diabetic rats. IEEE Trans Biomed Eng. https:\/\/doi.org\/10.1109\/TBME.2005.845240","journal-title":"IEEE Trans Biomed Eng"},{"key":"1317_CR33","doi-asserted-by":"publisher","DOI":"10.1016\/j.bioadv.2022.213169","author":"S De Martino","year":"2022","unstructured":"De Martino S et al (2022) Effect of microneedles shape on skin penetration and transdermal drug administration. Biomaterials Advances. https:\/\/doi.org\/10.1016\/j.bioadv.2022.213169","journal-title":"Biomaterials Advances"},{"key":"1317_CR34","doi-asserted-by":"publisher","DOI":"10.1002\/ADFM.202009850","author":"M Dervisevic","year":"2022","unstructured":"Dervisevic M et al (2022) Transdermal Electrochemical Monitoring of Glucose via High-Density Silicon Microneedle Array Patch. Adv Func Mater. https:\/\/doi.org\/10.1002\/ADFM.202009850","journal-title":"Adv Func Mater"},{"key":"1317_CR35","doi-asserted-by":"publisher","unstructured":"Economidou, S.N. et al. (2021). Optimisation of Design and Manufacturing Parameters of 3D Printed Solid Microneedles for Improved Strength, Sharpness, and Drug Delivery. Micromachines 2021, Vol. 12, Page 117. https:\/\/doi.org\/10.3390\/MI12020117.","DOI":"10.3390\/MI12020117"},{"key":"1317_CR36","doi-asserted-by":"publisher","DOI":"10.1016\/j.mfglet.2020.03.009","author":"T Evens","year":"2020","unstructured":"Evens T et al (2020) A novel method for producing solid polymer microneedles using laser ablated moulds in an injection moulding process. Manufacturing Letters. https:\/\/doi.org\/10.1016\/j.mfglet.2020.03.009","journal-title":"Manufacturing Letters"},{"key":"1317_CR37","doi-asserted-by":"publisher","DOI":"10.1016\/j.mfglet.2021.10.007","author":"Z Faraji Rad","year":"2021","unstructured":"Faraji Rad Z et al (2021) Rapid prototyping and customizable microneedle design: Ultra-sharp microneedle fabrication using two-photon polymerization and low-cost micromolding techniques. Manufacturing Letters. https:\/\/doi.org\/10.1016\/j.mfglet.2021.10.007","journal-title":"Manufacturing Letters"},{"key":"1317_CR38","doi-asserted-by":"publisher","DOI":"10.1002\/MABI.202000195","author":"DFS Fonseca","year":"2020","unstructured":"Fonseca DFS et al (2020) Swellable Gelatin Methacryloyl Microneedles for Extraction of Interstitial Skin Fluid toward Minimally Invasive Monitoring of Urea. Macromol Biosci. https:\/\/doi.org\/10.1002\/MABI.202000195","journal-title":"Macromol Biosci"},{"key":"1317_CR39","doi-asserted-by":"publisher","DOI":"10.1016\/J.JCONREL.2006.10.017","author":"HS Gill","year":"2007","unstructured":"Gill HS, e Prausnitz, M.R. (2007) Coated microneedles for transdermal delivery. J Control Release. https:\/\/doi.org\/10.1016\/J.JCONREL.2006.10.017","journal-title":"J Control Release"},{"key":"1317_CR40","doi-asserted-by":"publisher","DOI":"10.1088\/0960-1317\/22\/9\/095017","author":"AA Hamzah","year":"2012","unstructured":"Hamzah AA et al (2012) Optimization of HNA etching parameters to produce high aspect ratio solid silicon microneedles. J Micromech Microeng. https:\/\/doi.org\/10.1088\/0960-1317\/22\/9\/095017","journal-title":"J Micromech Microeng"},{"key":"1317_CR41","doi-asserted-by":"publisher","DOI":"10.1166\/JBN.2017.2474","author":"Y Hao","year":"2017","unstructured":"Hao Y et al (2017) Microneedles-Based Transdermal Drug Delivery Systems: A Review. J Biomed Nanotechnol. https:\/\/doi.org\/10.1166\/JBN.2017.2474","journal-title":"J Biomed Nanotechnol"},{"key":"1317_CR42","doi-asserted-by":"publisher","DOI":"10.3390\/MI14030615\/S1","author":"LV Hileghem","year":"2023","unstructured":"Hileghem LV et al (2023) Innovative Fabrication of Hollow Microneedle Arrays Enabling Blood Sampling with a Self-Powered Microfluidic Patch. Micromachines. https:\/\/doi.org\/10.3390\/MI14030615\/S1","journal-title":"Micromachines"},{"key":"1317_CR43","doi-asserted-by":"publisher","unstructured":"Holicky, M. et al. (2025). Wearable microneedle graphene field-effect transistor sensors. 2D Materials. https:\/\/doi.org\/10.1088\/2053-1583\/adac71.","DOI":"10.1088\/2053-1583\/adac71"},{"key":"1317_CR44","doi-asserted-by":"crossref","unstructured":"Hong, J.Y. et al. (2017). Efficacy and safety of a novel, soluble microneedle patch for the improvement of facial wrinkle. Journal of cosmetic dermatology.","DOI":"10.1111\/jocd.12426"},{"key":"1317_CR45","doi-asserted-by":"publisher","unstructured":"Horowitz LF et al (2020) Microfluidics for interrogating live intact tissues.\u00a0Microsyst Nanoeng. https:\/\/doi.org\/10.1038\/s41378-020-0164-0","DOI":"10.1038\/s41378-020-0164-0"},{"key":"1317_CR46","doi-asserted-by":"publisher","DOI":"10.1016\/j.jallcom.2023.169658","author":"Y-S Hsiao","year":"2023","unstructured":"Hsiao Y-S et al (2023) Microfluidic device using metallic nanostructure arrays for the isolation, detection, and purification of exosomes. J Alloy Compd. https:\/\/doi.org\/10.1016\/j.jallcom.2023.169658","journal-title":"J Alloy Compd"},{"key":"1317_CR47","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2025.123120","author":"L Huang","year":"2025","unstructured":"Huang L et al (2025) An approach for psoriasis of microneedle patch simultaneously targeting multiple inflammatory cytokines and relapse related T cells. Biomaterials. https:\/\/doi.org\/10.1016\/j.biomaterials.2025.123120","journal-title":"Biomaterials"},{"key":"1317_CR48","doi-asserted-by":"publisher","DOI":"10.1016\/J.BIOMATERIALS.2020.120491","author":"RSJ Ingrole","year":"2021","unstructured":"Ingrole RSJ et al (2021) Trends of microneedle technology in the scientific literature, patents, clinical trials and internet activity. Biomaterials. https:\/\/doi.org\/10.1016\/J.BIOMATERIALS.2020.120491","journal-title":"Biomaterials"},{"key":"1317_CR49","doi-asserted-by":"publisher","unstructured":"Invernale MA et al (2014) Microneedle electrodes toward an amperometric glucose-sensing smart patch.\u00a0Adv Healthc Mater. https:\/\/doi.org\/10.1002\/ADHM.201300142","DOI":"10.1002\/ADHM.201300142"},{"key":"1317_CR50","doi-asserted-by":"publisher","unstructured":"Ita K (2015) Transdermal delivery of drugs with microneedles\u2014potential and challenges. Pharmaceutics. https:\/\/doi.org\/10.3390\/pharmaceutics7030090","DOI":"10.3390\/pharmaceutics7030090"},{"key":"1317_CR51","doi-asserted-by":"publisher","DOI":"10.1016\/j.jddst.2018.03.021","author":"K Ita","year":"2018","unstructured":"Ita K (2018a) Modulation of transdermal drug delivery with coated microneedles. Journal of Drug Delivery Science and Technology. https:\/\/doi.org\/10.1016\/j.jddst.2018.03.021","journal-title":"Journal of Drug Delivery Science and Technology"},{"key":"1317_CR52","doi-asserted-by":"publisher","DOI":"10.1016\/J.JDDST.2018.01.004","author":"K Ita","year":"2018","unstructured":"Ita K (2018b) Ceramic microneedles and hollow microneedles for transdermal drug delivery: Two decades of research. Journal of Drug Delivery Science and Technology. https:\/\/doi.org\/10.1016\/J.JDDST.2018.01.004","journal-title":"Journal of Drug Delivery Science and Technology"},{"key":"1317_CR53","doi-asserted-by":"publisher","DOI":"10.1039\/C2RA20153D","author":"D Jenkins","year":"2012","unstructured":"Jenkins D et al (2012) High density and high aspect ratio solid micro-nanoprojection arrays for targeted skin vaccine delivery and specific antibody extraction. RSC Adv. https:\/\/doi.org\/10.1039\/C2RA20153D","journal-title":"RSC Adv"},{"key":"1317_CR54","doi-asserted-by":"publisher","unstructured":"Jeong HR et al\u00a0(2020) Safe coated microneedles with reduced puncture occurrence after administration. Micromachines 11:710. https:\/\/doi.org\/10.3390\/MI11080710","DOI":"10.3390\/MI11080710"},{"issue":"6","key":"1317_CR55","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41378-020-00206-1","volume":"2020","author":"X Jiang","year":"2020","unstructured":"Jiang X, e Lillehoj, P.B. (2020) Microneedle-based skin patch for blood-free rapid diagnostic testing. Microsyst Nanoeng 2020(6):1. https:\/\/doi.org\/10.1038\/s41378-020-00206-1","journal-title":"Microsyst Nanoeng"},{"key":"1317_CR56","doi-asserted-by":"publisher","DOI":"10.1177\/1932296814526191","author":"A Jina","year":"2014","unstructured":"Jina A et al (2014) Design, development, and evaluation of a novel microneedle array-based continuous glucose monitor. J Diabetes Sci Technol. https:\/\/doi.org\/10.1177\/1932296814526191","journal-title":"J Diabetes Sci Technol"},{"key":"1317_CR57","doi-asserted-by":"publisher","DOI":"10.1016\/J.BIOS.2020.112281","author":"YE Kang","year":"2020","unstructured":"Kang YE et al (2020) Nanochannel-driven rapid capture of sub-nanogram level biomarkers for painless preeclampsia diagnosis. Biosens Bioelectron. https:\/\/doi.org\/10.1016\/J.BIOS.2020.112281","journal-title":"Biosens Bioelectron"},{"key":"1317_CR58","doi-asserted-by":"publisher","unstructured":"Kashaninejad, N. et al. (2021). Microneedle Arrays for Sampling and Sensing Skin Interstitial Fluid. Chemosensors 2021, Vol. 9, Page 83. https:\/\/doi.org\/10.3390\/CHEMOSENSORS9040083.","DOI":"10.3390\/CHEMOSENSORS9040083"},{"key":"1317_CR59","doi-asserted-by":"publisher","DOI":"10.1007\/S00542-006-0221-0\/FIGURES\/7","author":"K Kim","year":"2007","unstructured":"Kim K, e Lee, J.B. (2007) High aspect ratio tapered hollow metallic microneedle arrays with microfluidic interconnector. Microsyst Technol. https:\/\/doi.org\/10.1007\/S00542-006-0221-0\/FIGURES\/7","journal-title":"Microsyst Technol"},{"key":"1317_CR60","doi-asserted-by":"publisher","DOI":"10.1111\/ics.12115","author":"M Kim","year":"2014","unstructured":"Kim M et al (2014) Novel cosmetic patches for wrinkle improvement: retinyl retinoate- and ascorbic acid-loaded dissolving microneedles. Int J Cosmet Sci. https:\/\/doi.org\/10.1111\/ics.12115","journal-title":"Int J Cosmet Sci"},{"key":"1317_CR61","doi-asserted-by":"publisher","unstructured":"Kim KB et al (2019) Continuous glucose monitoring using a microneedle array sensor coupled with a wireless signal transmitter.\u00a0Sens Actuators B: Chem. https:\/\/doi.org\/10.1016\/J.SNB.2018.10.081","DOI":"10.1016\/J.SNB.2018.10.081"},{"key":"1317_CR62","doi-asserted-by":"publisher","DOI":"10.1039\/C2LC40761B\/","author":"PJ Kitson","year":"2012","unstructured":"Kitson PJ et al (2012) Configurable 3D-Printed millifluidic and microfluidic \u00ablab on a chip\u00bb reactionware devices. Lab Chip. https:\/\/doi.org\/10.1039\/C2LC40761B\/","journal-title":"Lab Chip"},{"key":"1317_CR63","doi-asserted-by":"publisher","DOI":"10.1038\/s41378-019-0088-8","author":"KJ Krieger","year":"2019","unstructured":"Krieger KJ et al (2019) Simple and customizable method for fabrication of high-aspect ratio microneedle molds using low-cost 3D printing. Microsyst Nanoeng. https:\/\/doi.org\/10.1038\/s41378-019-0088-8","journal-title":"Microsyst Nanoeng"},{"key":"1317_CR64","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-021-20948-4","author":"S Kusama","year":"2021","unstructured":"Kusama S et al (2021) Transdermal electroosmotic flow generated by a porous microneedle array patch. Nat Commun. https:\/\/doi.org\/10.1038\/s41467-021-20948-4","journal-title":"Nat Commun"},{"key":"1317_CR65","doi-asserted-by":"publisher","DOI":"10.1016\/J.SNB.2015.08.013","author":"SJ Lee","year":"2016","unstructured":"Lee SJ et al (2016) A patch type non-enzymatic biosensor based on 3D SUS micro-needle electrode array for minimally invasive continuous glucose monitoring. Sens Actuators, B Chem. https:\/\/doi.org\/10.1016\/J.SNB.2015.08.013","journal-title":"Sens Actuators, B Chem"},{"key":"1317_CR66","doi-asserted-by":"publisher","DOI":"10.1186\/s12951-025-03119-1","author":"C Li","year":"2025","unstructured":"Li C et al (2025) Biomimetic polydopamine loaded with janus kinase inhibitor for synergistic vitiligo therapy via hydrogel microneedles. Journal of Nanobiotechnology. https:\/\/doi.org\/10.1186\/s12951-025-03119-1","journal-title":"Journal of Nanobiotechnology"},{"key":"1317_CR67","doi-asserted-by":"publisher","DOI":"10.1109\/MEMS51782.2021.9375246","author":"J Li","year":"2021","unstructured":"Li J et al (2021) Annular Micro-Needle Array as a Minimally Invasive Flexible Dry Electrode for on-Hair EEG Recording. Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS). https:\/\/doi.org\/10.1109\/MEMS51782.2021.9375246","journal-title":"Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)"},{"key":"1317_CR68","doi-asserted-by":"publisher","DOI":"10.1039\/C6RA26759A","author":"QY Li","year":"2017","unstructured":"Li QY et al (2017) A solid polymer microneedle patch pretreatment enhances the permeation of drug molecules into the skin. RSC Adv. https:\/\/doi.org\/10.1039\/C6RA26759A","journal-title":"RSC Adv"},{"key":"1317_CR69","doi-asserted-by":"publisher","DOI":"10.1021\/acs.chemrev.7b00074","author":"SC Ligon","year":"2017","unstructured":"Ligon SC et al (2017) Polymers for 3D Printing and Customized Additive Manufacturing. Chem Rev. https:\/\/doi.org\/10.1021\/acs.chemrev.7b00074","journal-title":"Chem Rev"},{"key":"1317_CR70","doi-asserted-by":"publisher","DOI":"10.1021\/acs.molpharmaceut.4c01266","author":"Y Lin","year":"2025","unstructured":"Lin Y et al (2025) Tailoring Design of Microneedles for Drug Delivery and Biosensing. Mol Pharm. https:\/\/doi.org\/10.1021\/acs.molpharmaceut.4c01266","journal-title":"Mol Pharm"},{"key":"1317_CR71","doi-asserted-by":"publisher","DOI":"10.1016\/J.BIOMATERIALS.2019.119740","author":"GS Liu","year":"2020","unstructured":"Liu GS et al (2020) Microneedles for transdermal diagnostics: Recent advances and new horizons. Biomaterials. https:\/\/doi.org\/10.1016\/J.BIOMATERIALS.2019.119740","journal-title":"Biomaterials"},{"key":"1317_CR72","doi-asserted-by":"publisher","DOI":"10.1039\/C6RA07882F","author":"L Liu","year":"2016","unstructured":"Liu L et al (2016) Porous polymer microneedles with interconnecting microchannels for rapid fluid transport. RSC Adv. https:\/\/doi.org\/10.1039\/C6RA07882F","journal-title":"RSC Adv"},{"key":"1317_CR73","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijpharm.2023.123143","author":"MC Lobita","year":"2023","unstructured":"Lobita MC et al (2023) Development of fast dissolving polymer-based microneedles for delivery of an antigenic melanoma cell membrane. Int J Pharm. https:\/\/doi.org\/10.1016\/j.ijpharm.2023.123143","journal-title":"Int J Pharm"},{"key":"1317_CR74","doi-asserted-by":"publisher","DOI":"10.3389\/FBIOE.2022.851134","author":"H Lu","year":"2022","unstructured":"Lu H et al (2022) Microneedle-Based Device for Biological Analysis. Frontiers in Bioengineering and Biotechnology. https:\/\/doi.org\/10.3389\/FBIOE.2022.851134","journal-title":"Frontiers in Bioengineering and Biotechnology"},{"key":"1317_CR75","doi-asserted-by":"publisher","DOI":"10.1039\/C8LC00098K","author":"MA Luzuriaga","year":"2018","unstructured":"Luzuriaga MA et al (2018) Biodegradable 3D printed polymer microneedles for transdermal drug delivery. Lab Chip. https:\/\/doi.org\/10.1039\/C8LC00098K","journal-title":"Lab Chip"},{"key":"1317_CR76","doi-asserted-by":"publisher","DOI":"10.1007\/S10404-006-0083-X\/FIGURES\/13","author":"B Ma","year":"2006","unstructured":"Ma B et al (2006) A PZT insulin pump integrated with a silicon microneedle array for transdermal drug delivery. Microfluid Nanofluid. https:\/\/doi.org\/10.1007\/S10404-006-0083-X\/FIGURES\/13","journal-title":"Microfluid Nanofluid"},{"key":"1317_CR77","doi-asserted-by":"publisher","DOI":"10.1016\/J.JPHA.2022.12.004","author":"S Ma","year":"2023","unstructured":"Ma S et al (2023) Microneedle-based interstitial fluid extraction for drug analysis: Advances, challenges, and prospects. Journal of Pharmaceutical Analysis. https:\/\/doi.org\/10.1016\/J.JPHA.2022.12.004","journal-title":"Journal of Pharmaceutical Analysis"},{"key":"1317_CR78","doi-asserted-by":"publisher","unstructured":"Maia R et al (2024) PDMS porous microneedles used as engineered tool in advanced microfluidic devices and their proof-of-concept for biomarker detection.\u00a0Chem Eng J 485:149725. https:\/\/doi.org\/10.1016\/j.cej.2024.149725","DOI":"10.1016\/j.cej.2024.149725"},{"key":"1317_CR79","doi-asserted-by":"publisher","unstructured":"Maia R\u00a0et al (2023) Microneedles in advanced microfluidic systems: A systematic review throughout lab and organ-on-a-chip applications. Pharmaceutics 15(3):792. https:\/\/doi.org\/10.3390\/pharmaceutics15030792","DOI":"10.3390\/pharmaceutics15030792"},{"key":"1317_CR80","doi-asserted-by":"publisher","DOI":"10.1088\/0960-1317\/23\/8\/085011","author":"I Mansoor","year":"2013","unstructured":"Mansoor I et al (2013) Arrays of hollow out-of-plane microneedles made by metal electrodeposition onto solvent cast conductive polymer structures. J Micromech Microeng. https:\/\/doi.org\/10.1088\/0960-1317\/23\/8\/085011","journal-title":"J Micromech Microeng"},{"key":"1317_CR81","doi-asserted-by":"publisher","DOI":"10.1007\/s13346-024-01542-9","author":"M Mart\u00ednez-Navarrete","year":"2024","unstructured":"Mart\u00ednez-Navarrete M et al (2024) Cyclosporin A-loaded dissolving microneedles for dermatitis therapy: Development, characterisation and efficacy in a delayed-type hypersensitivity in vivo model. Drug Deliv Transl Res. https:\/\/doi.org\/10.1007\/s13346-024-01542-9","journal-title":"Drug Deliv Transl Res"},{"key":"1317_CR82","doi-asserted-by":"publisher","DOI":"10.1016\/J.IJPHARM.2011.05.064","author":"MG McGrath","year":"2011","unstructured":"McGrath MG et al (2011) Determination of parameters for successful spray coating of silicon microneedle arrays. Int J Pharm. https:\/\/doi.org\/10.1016\/J.IJPHARM.2011.05.064","journal-title":"Int J Pharm"},{"key":"1317_CR83","doi-asserted-by":"publisher","DOI":"10.1016\/j.jare.2020.07.017","author":"F Meng","year":"2020","unstructured":"Meng F et al (2020b) Polymeric-based microneedle arrays as potential platforms in the development of drugs delivery systems. J Adv Res. https:\/\/doi.org\/10.1016\/j.jare.2020.07.017","journal-title":"J Adv Res"},{"key":"1317_CR84","doi-asserted-by":"publisher","DOI":"10.1016\/j.pnsc.2020.09.016","author":"X Meng","year":"2020","unstructured":"Meng X et al (2020a) Micro\/nano needles for advanced drug delivery. Progress in Natural Science: Materials International. https:\/\/doi.org\/10.1016\/j.pnsc.2020.09.016","journal-title":"Progress in Natural Science: Materials International"},{"issue":"1063\/1","key":"1317_CR85","first-page":"3569945","volume":"10","author":"PR Miller","year":"2011","unstructured":"Miller PR et al (2011) Integrated carbon fiber electrodes within hollow polymer microneedles for transdermal electrochemical sensing. Biomicrofluidics Doi 10(1063\/1):3569945","journal-title":"Biomicrofluidics Doi"},{"key":"1317_CR86","doi-asserted-by":"publisher","DOI":"10.1016\/J.TALANTA.2011.11.046","author":"PR Miller","year":"2012","unstructured":"Miller PR et al (2012) Multiplexed microneedle-based biosensor array for characterization of metabolic acidosis. Talanta. https:\/\/doi.org\/10.1016\/J.TALANTA.2011.11.046","journal-title":"Talanta"},{"key":"1317_CR87","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6439\/AAD301","author":"R Mishra","year":"2018","unstructured":"Mishra R et al (2018) Development of SU-8 hollow microneedles on a silicon substrate with microfluidic interconnects for transdermal drug delivery. J Micromech Microeng. https:\/\/doi.org\/10.1088\/1361-6439\/AAD301","journal-title":"J Micromech Microeng"},{"key":"1317_CR88","doi-asserted-by":"publisher","DOI":"10.1016\/j.bios.2017.01.016","author":"AMV Mohan","year":"2017","unstructured":"Mohan AMV et al (2017) Continuous minimally-invasive alcohol monitoring using microneedle sensor arrays. Biosens Bioelectron. https:\/\/doi.org\/10.1016\/j.bios.2017.01.016","journal-title":"Biosens Bioelectron"},{"key":"1317_CR89","doi-asserted-by":"publisher","DOI":"10.1016\/J.PHRS.2019.104438","author":"AF Moreira","year":"2019","unstructured":"Moreira AF et al (2019) Microneedle-based delivery devices for cancer therapy: A review. Pharmacol Res. https:\/\/doi.org\/10.1016\/J.PHRS.2019.104438","journal-title":"Pharmacol Res"},{"key":"1317_CR90","doi-asserted-by":"publisher","DOI":"10.1016\/j.sna.2003.11.008","author":"EV Mukerjee","year":"2004","unstructured":"Mukerjee EV et al (2004) Microneedle array for transdermal biological fluid extraction and in situ analysis. Sens Actuators, A. https:\/\/doi.org\/10.1016\/j.sna.2003.11.008","journal-title":"Sens Actuators, A"},{"key":"1317_CR91","doi-asserted-by":"publisher","unstructured":"Najmi A et al (2021) Fabrication of a microdialysis-based nonenzymatic microfluidic sensor for regular glucose measurement.\u00a0Sens Actuators B: Chem.https:\/\/doi.org\/10.1016\/j.snb.2021.129569","DOI":"10.1016\/j.snb.2021.129569"},{"key":"1317_CR92","doi-asserted-by":"publisher","DOI":"10.1007\/S00170-018-2596-3\/METRICS","author":"SP Narayanan","year":"2019","unstructured":"Narayanan SP, e Raghavan, S. (2019) Fabrication and characterization of gold-coated solid silicon microneedles with improved biocompatibility. Int J Adv Manuf Technol. https:\/\/doi.org\/10.1007\/S00170-018-2596-3\/METRICS","journal-title":"Int J Adv Manuf Technol"},{"key":"1317_CR93","doi-asserted-by":"publisher","DOI":"10.1021\/ACSAMI.0C05750","author":"S Ni","year":"2021","unstructured":"Ni S et al (2021) Recent Progress in Aptamer Discoveries and Modifications for Therapeutic Applications. ACS Appl Mater Interfaces. https:\/\/doi.org\/10.1021\/ACSAMI.0C05750","journal-title":"ACS Appl Mater Interfaces"},{"key":"1317_CR94","doi-asserted-by":"publisher","DOI":"10.1016\/J.IJPHARM.2018.06.002","author":"D Nicholas","year":"2018","unstructured":"Nicholas D et al (2018) Rapid paper based colorimetric detection of glucose using a hollow microneedle device. Int J Pharm. https:\/\/doi.org\/10.1016\/J.IJPHARM.2018.06.002","journal-title":"Int J Pharm"},{"key":"1317_CR95","doi-asserted-by":"publisher","DOI":"10.1016\/j.jddst.2025.106768","author":"Y Pei","year":"2025","unstructured":"Pei Y et al (2025) Dendritic cells-targeted delivery of mRNA vaccines and dual siRNAs via microneedles effectively inhibits tumor growth. Journal of Drug Delivery Science and Technology. https:\/\/doi.org\/10.1016\/j.jddst.2025.106768","journal-title":"Journal of Drug Delivery Science and Technology"},{"key":"1317_CR96","doi-asserted-by":"publisher","DOI":"10.1016\/j.msec.2021.112226","author":"K Peng","year":"2021","unstructured":"Peng K et al (2021) Hydrogel-forming microneedles for rapid and efficient skin deposition of controlled release tip-implants. Mater Sci Eng, C. https:\/\/doi.org\/10.1016\/j.msec.2021.112226","journal-title":"Mater Sci Eng, C"},{"key":"1317_CR97","doi-asserted-by":"publisher","DOI":"10.1016\/J.IJPHARM.2018.03.031","author":"CPP Pere","year":"2018","unstructured":"Pere CPP et al (2018) 3D printed microneedles for insulin skin delivery. Int J Pharm. https:\/\/doi.org\/10.1016\/J.IJPHARM.2018.03.031","journal-title":"Int J Pharm"},{"key":"1317_CR98","doi-asserted-by":"publisher","DOI":"10.1007\/s00170-016-9698-6","author":"S Pradeep Narayanan","year":"2017","unstructured":"Pradeep Narayanan S, e Raghavan, S. (2017) Solid silicon microneedles for drug delivery applications. The International Journal of Advanced Manufacturing Technology. https:\/\/doi.org\/10.1007\/s00170-016-9698-6","journal-title":"The International Journal of Advanced Manufacturing Technology"},{"issue":"6","key":"1317_CR99","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/srep29075","volume":"2016","author":"SA Ranamukhaarachchi","year":"2016","unstructured":"Ranamukhaarachchi SA et al (2016) Integrated hollow microneedle-optofluidic biosensor for therapeutic drug monitoring in sub-nanoliter volumes. Sci Rep 2016(6):1. https:\/\/doi.org\/10.1038\/srep29075","journal-title":"Sci Rep"},{"key":"1317_CR100","doi-asserted-by":"publisher","unstructured":"Ren L\u00a0et al\u00a0(2018) Fabrication of flexible microneedle array electrodes for wearable bio-signal recording. Sensors (Basel, Switzerland). https:\/\/doi.org\/10.3390\/S18041191","DOI":"10.3390\/S18041191"},{"key":"1317_CR101","doi-asserted-by":"publisher","unstructured":"Ribet F et al (2018) Microneedle-based system for minimally invasive continuous monitoring of glucose in the dermal interstitial fluid. In: Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS). https:\/\/doi.org\/10.1109\/MEMSYS.2018.8346574","DOI":"10.1109\/MEMSYS.2018.8346574"},{"key":"1317_CR102","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2014.09.015","author":"AM R\u00f6mgens","year":"2014","unstructured":"R\u00f6mgens AM et al (2014) Monitoring the penetration process of single microneedles with varying tip diameters. J Mech Behav Biomed Mater. https:\/\/doi.org\/10.1016\/j.jmbbm.2014.09.015","journal-title":"J Mech Behav Biomed Mater"},{"key":"1317_CR103","doi-asserted-by":"publisher","DOI":"10.1109\/JMEMS.2007.907461","author":"N Roxhed","year":"2007","unstructured":"Roxhed N et al (2007) Penetration-enhanced ultrasharp microneedles and prediction on skin interaction for efficient transdermal drug delivery. J Microelectromech Syst. https:\/\/doi.org\/10.1109\/JMEMS.2007.907461","journal-title":"J Microelectromech Syst"},{"key":"1317_CR104","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-022-05912-6","author":"A Sadeqi","year":"2022","unstructured":"Sadeqi A et al (2022) Hard polymeric porous microneedles on stretchable substrate for transdermal drug delivery. Sci Rep. https:\/\/doi.org\/10.1038\/s41598-022-05912-6","journal-title":"Sci Rep"},{"key":"1317_CR105","doi-asserted-by":"publisher","DOI":"10.1021\/BM1009443\/SUPPL_FILE\/BM1009443_SI_001.PDF","author":"EM Saurer","year":"2010","unstructured":"Saurer EM et al (2010) Layer-by-layer assembly of DNA- and protein-containing films on microneedles for drug delivery to the skin. Biomacromol. https:\/\/doi.org\/10.1021\/BM1009443\/SUPPL_FILE\/BM1009443_SI_001.PDF","journal-title":"Biomacromol"},{"key":"1317_CR106","doi-asserted-by":"publisher","DOI":"10.1039\/C7LC00468K","author":"M Singh","year":"2017","unstructured":"Singh M et al (2017) 3D printed conformal microfluidics for isolation and profiling of biomarkers from whole organs. Lab Chip. https:\/\/doi.org\/10.1039\/C7LC00468K","journal-title":"Lab Chip"},{"key":"1317_CR107","doi-asserted-by":"publisher","DOI":"10.1117\/12.2299264","author":"R Smith","year":"2018","unstructured":"Smith R et al (2018). Silicon Microneedle Array for Minimally Invasive Human Health Monitoring. https:\/\/doi.org\/10.1117\/12.2299264","journal-title":"Silicon Microneedle Array for Minimally Invasive Human Health Monitoring"},{"key":"1317_CR108","doi-asserted-by":"publisher","DOI":"10.1016\/j.jddst.2022.103119","author":"V Sonetha","year":"2022","unstructured":"Sonetha V et al (2022) Step-wise micro-fabrication techniques of microneedle arrays with applications in transdermal drug delivery \u2013 A review. Journal of Drug Delivery Science and Technology. https:\/\/doi.org\/10.1016\/j.jddst.2022.103119","journal-title":"Journal of Drug Delivery Science and Technology"},{"key":"1317_CR109","doi-asserted-by":"publisher","DOI":"10.1016\/J.SNA.2015.10.041","author":"AK Srivastava","year":"2015","unstructured":"Srivastava AK et al (2015) Long term biopotential recording by body conformable photolithography fabricated low cost polymeric microneedle arrays. Sens Actuators, A. https:\/\/doi.org\/10.1016\/J.SNA.2015.10.041","journal-title":"Sens Actuators, A"},{"key":"1317_CR110","doi-asserted-by":"publisher","DOI":"10.1021\/ACSNANO.9B04783","author":"DA Sulaiman","year":"2019","unstructured":"Sulaiman DA et al (2019) Hydrogel-Coated Microneedle Arrays for Minimally Invasive Sampling and Sensing of Specific Circulating Nucleic Acids from Skin Interstitial Fluid. ACS Nano. https:\/\/doi.org\/10.1021\/ACSNANO.9B04783","journal-title":"ACS Nano"},{"key":"1317_CR111","doi-asserted-by":"publisher","DOI":"10.1007\/s13346-021-01050-0","author":"K Takeuchi","year":"2022","unstructured":"Takeuchi K et al (2022) Microfluidic chip connected to porous microneedle array for continuous ISF sampling. Drug Deliv Transl Res. https:\/\/doi.org\/10.1007\/s13346-021-01050-0","journal-title":"Drug Deliv Transl Res"},{"key":"1317_CR112","doi-asserted-by":"publisher","DOI":"10.1126\/sciadv.aat9365","author":"J Tang","year":"2018","unstructured":"Tang J et al (2018b) Cardiac cell\u2013integrated microneedle patch for treating myocardial infarction. Sci Adv. https:\/\/doi.org\/10.1126\/sciadv.aat9365","journal-title":"Sci Adv"},{"key":"1317_CR113","doi-asserted-by":"publisher","DOI":"10.1109\/JMEMS.2018.2843722","author":"Y Tang","year":"2018","unstructured":"Tang Y et al (2018a) Ultra Deep Reactive Ion Etching of High Aspect-Ratio and Thick Silicon Using a Ramped-Parameter Process. J Microelectromech Syst. https:\/\/doi.org\/10.1109\/JMEMS.2018.2843722","journal-title":"J Microelectromech Syst"},{"key":"1317_CR114","doi-asserted-by":"publisher","DOI":"10.1007\/s13346-017-0466-4","author":"TN Tarbox","year":"2018","unstructured":"Tarbox TN et al (2018) An update on coating\/manufacturing techniques of microneedles. Drug Deliv Transl Res. https:\/\/doi.org\/10.1007\/s13346-017-0466-4","journal-title":"Drug Deliv Transl Res"},{"key":"1317_CR115","doi-asserted-by":"publisher","DOI":"10.1039\/C1LC20885C","author":"J Trzebinski","year":"2012","unstructured":"Trzebinski J et al (2012) Microfluidic device to investigate factors affecting performance in biosensors designed for transdermal applications. Lab Chip. https:\/\/doi.org\/10.1039\/C1LC20885C","journal-title":"Lab Chip"},{"key":"1317_CR116","doi-asserted-by":"publisher","DOI":"10.1016\/j.bioadv.2023.213467","author":"JG Turner","year":"2023","unstructured":"Turner JG et al (2023) Antimicrobial releasing hydrogel forming microneedles. Biomaterials Advances. https:\/\/doi.org\/10.1016\/j.bioadv.2023.213467","journal-title":"Biomaterials Advances"},{"key":"1317_CR117","doi-asserted-by":"publisher","DOI":"10.1098\/rsos.171609","author":"A Ullah","year":"2018","unstructured":"Ullah A et al (2018) Porous polymer coatings on metal microneedles for enhanced drug delivery. Royal Society Open Science. https:\/\/doi.org\/10.1098\/rsos.171609","journal-title":"Royal Society Open Science"},{"key":"1317_CR118","doi-asserted-by":"publisher","DOI":"10.1007\/s13346-015-0238-y","author":"K van der Maaden","year":"2015","unstructured":"van der Maaden K et al (2015) Microneedle-based drug and vaccine delivery via nanoporous microneedle arrays. Drug Deliv Transl Res. https:\/\/doi.org\/10.1007\/s13346-015-0238-y","journal-title":"Drug Deliv Transl Res"},{"key":"1317_CR119","doi-asserted-by":"publisher","DOI":"10.1016\/J.JCONREL.2017.11.035","author":"K van der Maaden","year":"2018","unstructured":"van der Maaden K et al (2018) Hollow microneedle-mediated micro-injections of a liposomal HPV E743\u201363 synthetic long peptide vaccine for efficient induction of cytotoxic and T-helper responses. Journal of Controlled Release\u202f: Official Journal of the Controlled Release Society. https:\/\/doi.org\/10.1016\/J.JCONREL.2017.11.035","journal-title":"Journal of Controlled Release : Official Journal of the Controlled Release Society"},{"key":"1317_CR120","doi-asserted-by":"publisher","DOI":"10.1021\/ACS.ANALCHEM.0C04944\/SUPPL_FILE\/AC0C04944_SI_001.PDF","author":"B Venzac","year":"2021","unstructured":"Venzac B et al (2021) PDMS Curing Inhibition on 3D-Printed Molds: Why? Also, How to Avoid It? Anal Chem. https:\/\/doi.org\/10.1021\/ACS.ANALCHEM.0C04944\/SUPPL_FILE\/AC0C04944_SI_001.PDF","journal-title":"Anal Chem"},{"key":"1317_CR121","doi-asserted-by":"publisher","DOI":"10.1016\/j.biopha.2018.10.078","author":"T Waghule","year":"2019","unstructured":"Waghule T et al (2019) Microneedles: A smart approach and increasing potential for transdermal drug delivery system. Biomed Pharmacother. https:\/\/doi.org\/10.1016\/j.biopha.2018.10.078","journal-title":"Biomed Pharmacother"},{"key":"1317_CR122","doi-asserted-by":"publisher","DOI":"10.1021\/acs.nanolett.5b05030","author":"C Wang","year":"2016","unstructured":"Wang C et al (2016) Enhanced Cancer Immunotherapy by Microneedle Patch-Assisted Delivery of Anti-PD1 Antibody. Nano Lett. https:\/\/doi.org\/10.1021\/acs.nanolett.5b05030","journal-title":"Nano Lett"},{"key":"1317_CR123","doi-asserted-by":"publisher","DOI":"10.1016\/J.COBME.2021.100326","author":"H Wang","year":"2021","unstructured":"Wang H et al (2021b) Recent advances in transdermal sensors for glucose monitoring. Current Opinion in Biomedical Engineering. https:\/\/doi.org\/10.1016\/J.COBME.2021.100326","journal-title":"Current Opinion in Biomedical Engineering"},{"key":"1317_CR124","doi-asserted-by":"publisher","DOI":"10.1016\/J.SNB.2017.01.052","author":"R Wang","year":"2017","unstructured":"Wang R et al (2017) A microneedle electrode array on flexible substrate for long-term EEG monitoring. Sens Actuators, B Chem. https:\/\/doi.org\/10.1016\/J.SNB.2017.01.052","journal-title":"Sens Actuators, B Chem"},{"key":"1317_CR125","doi-asserted-by":"publisher","DOI":"10.1038\/s41551-020-00672-y","author":"Z Wang","year":"2021","unstructured":"Wang Z et al (2021a) Microneedle patch for the ultrasensitive quantification of protein biomarkers in interstitial fluid. Nature Biomedical Engineering. https:\/\/doi.org\/10.1038\/s41551-020-00672-y","journal-title":"Nature Biomedical Engineering"},{"key":"1317_CR126","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijbiomac.2024.138885","author":"Z Wang","year":"2025","unstructured":"Wang Z et al (2025) A review on recent advances in polymeric microneedle loading cells: Design strategies, fabrication technologies, transdermal application and challenges. Int J Biol Macromol. https:\/\/doi.org\/10.1016\/j.ijbiomac.2024.138885","journal-title":"Int J Biol Macromol"},{"key":"1317_CR127","doi-asserted-by":"publisher","DOI":"10.1016\/J.SNA.2005.05.017","author":"N Wilke","year":"2005","unstructured":"Wilke N et al (2005) Silicon microneedle electrode array with temperature monitoring for electroporation. Sens Actuators, A. https:\/\/doi.org\/10.1016\/J.SNA.2005.05.017","journal-title":"Sens Actuators, A"},{"key":"1317_CR128","doi-asserted-by":"publisher","DOI":"10.1002\/ELAN.201100361","author":"JR Windmiller","year":"2011","unstructured":"Windmiller JR et al (2011a) Bicomponent Microneedle Array Biosensor for Minimally-Invasive Glutamate Monitoring. Electroanalysis. https:\/\/doi.org\/10.1002\/ELAN.201100361","journal-title":"Electroanalysis"},{"key":"1317_CR129","doi-asserted-by":"publisher","DOI":"10.1039\/C1AN00012H","author":"JR Windmiller","year":"2011","unstructured":"Windmiller JR et al (2011b) Microneedle array-based carbon paste amperometric sensors and biosensors. Analyst. https:\/\/doi.org\/10.1039\/C1AN00012H","journal-title":"Analyst"},{"key":"1317_CR130","doi-asserted-by":"publisher","unstructured":"Woedtke TV et al (2002) Sterilization of enzyme glucose sensors: problems and concepts.\u00a0Biosens Bioelectron. https:\/\/doi.org\/10.1016\/S0956-5663(01)00310-4","DOI":"10.1016\/S0956-5663(01)00310-4"},{"key":"1317_CR131","doi-asserted-by":"publisher","DOI":"10.1007\/s00604-025-07096-y","author":"N Xiao","year":"2025","unstructured":"Xiao N et al (2025) An electrochromism-equipped enzymatic biofuel cell system combined with hollow microneedle array for self-powered glucose sensing in interstitial fluid. Microchim Acta. https:\/\/doi.org\/10.1007\/s00604-025-07096-y","journal-title":"Microchim Acta"},{"key":"1317_CR132","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijpharm.2021.120815","author":"V Yadav","year":"2021","unstructured":"Yadav V et al (2021) 3D printed hollow microneedles array using stereolithography for efficient transdermal delivery of rifampicin. Int J Pharm. https:\/\/doi.org\/10.1016\/j.ijpharm.2021.120815","journal-title":"Int J Pharm"},{"key":"1317_CR133","doi-asserted-by":"publisher","DOI":"10.1016\/J.APSB.2019.03.007","author":"J Yang","year":"2019","unstructured":"Yang J et al (2019) Recent advances of microneedles for biomedical applications: drug delivery and beyond. Acta Pharmaceutica Sinica B. https:\/\/doi.org\/10.1016\/J.APSB.2019.03.007","journal-title":"Acta Pharmaceutica Sinica B"},{"key":"1317_CR134","doi-asserted-by":"publisher","DOI":"10.1016\/j.bioactmat.2021.01.014","author":"B Yang","year":"2021","unstructured":"Yang B et al (2021) Bilayer dissolving microneedle array containing 5-fluorouracil and triamcinolone with biphasic release profile for hypertrophic scar therapy. Bioactive Materials. https:\/\/doi.org\/10.1016\/j.bioactmat.2021.01.014","journal-title":"Bioactive Materials"},{"key":"1317_CR135","doi-asserted-by":"publisher","DOI":"10.1002\/adhm.202102547","author":"J Yang","year":"2022","unstructured":"Yang J et al (2022a) Recent Progress in Microneedles-Mediated Diagnosis, Therapy, and Theranostic Systems. Adv Healthcare Mater. https:\/\/doi.org\/10.1002\/adhm.202102547","journal-title":"Adv Healthcare Mater"},{"key":"1317_CR136","doi-asserted-by":"publisher","DOI":"10.1016\/j.cclet.2021.08.105","author":"J Yang","year":"2022","unstructured":"Yang J et al (2022b) An integrative review on the applications of 3D printing in the field of in vitro diagnostics. Chin Chem Lett. https:\/\/doi.org\/10.1016\/j.cclet.2021.08.105","journal-title":"Chin Chem Lett"},{"key":"1317_CR137","doi-asserted-by":"publisher","DOI":"10.1021\/acssensors.2c02635","author":"J Yang","year":"2023","unstructured":"Yang J et al (2023) Development of Smartphone-Controlled and Microneedle-Based Wearable Continuous Glucose Monitoring System for Home-Care Diabetes Management. ACS Sensors. https:\/\/doi.org\/10.1021\/acssensors.2c02635","journal-title":"ACS Sensors"},{"key":"1317_CR138","doi-asserted-by":"publisher","DOI":"10.1016\/j.bios.2021.113404","author":"K Yi","year":"2021","unstructured":"Yi K et al (2021) Aptamer-decorated porous microneedles arrays for extraction and detection of skin interstitial fluid biomarkers. Biosens Bioelectron. https:\/\/doi.org\/10.1016\/j.bios.2021.113404","journal-title":"Biosens Bioelectron"},{"key":"1317_CR139","doi-asserted-by":"publisher","DOI":"10.1016\/J.SNA.2009.01.020","author":"LM Yu","year":"2009","unstructured":"Yu LM et al (2009) A microfabricated electrode with hollow microneedles for ECG measurement. Sens Actuators, A. https:\/\/doi.org\/10.1016\/J.SNA.2009.01.020","journal-title":"Sens Actuators, A"},{"key":"1317_CR140","doi-asserted-by":"publisher","DOI":"10.1186\/s10033-025-01188-9","author":"Z Yuan","year":"2025","unstructured":"Yuan Z et al (2025) State-of-the-art Review of Metallic Microneedles: Structure, Fabrication, and Application. Chinese Journal of Mechanical Engineering. https:\/\/doi.org\/10.1186\/s10033-025-01188-9","journal-title":"Chinese Journal of Mechanical Engineering"},{"key":"1317_CR141","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijpharm.2021.120749","author":"L Zhang","year":"2021","unstructured":"Zhang L et al (2021a) Fabrication, evaluation and applications of dissolving microneedles. Int J Pharm. https:\/\/doi.org\/10.1016\/j.ijpharm.2021.120749","journal-title":"Int J Pharm"},{"key":"1317_CR142","doi-asserted-by":"publisher","DOI":"10.1016\/J.MICROC.2020.105830","author":"BL Zhang","year":"2021","unstructured":"Zhang BL et al (2021b) Microneedle-assisted technology for minimally invasive medical sensing. Microchem J. https:\/\/doi.org\/10.1016\/J.MICROC.2020.105830","journal-title":"Microchem J"},{"key":"1317_CR143","doi-asserted-by":"publisher","unstructured":"Zhang X et al (2019) Encoded microneedle arrays for detection of skin interstitial fluid biomarkers. Adv Mater. https:\/\/doi.org\/10.1002\/adma.201902825","DOI":"10.1002\/adma.201902825"},{"key":"1317_CR144","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejpb.2020.10.002","author":"J Zhuang","year":"2020","unstructured":"Zhuang J et al (2020) Study on the fabrication and characterization of tip-loaded dissolving microneedles for transdermal drug delivery. Eur J Pharm Biopharm. https:\/\/doi.org\/10.1016\/j.ejpb.2020.10.002","journal-title":"Eur J Pharm Biopharm"},{"key":"1317_CR145","doi-asserted-by":"publisher","unstructured":"Zhu DD et al (2020) Safety assessment of microneedle technology for transdermal drug delivery: a review.\u00a0Adv Ther. https:\/\/doi.org\/10.1002\/ADTP.202000033","DOI":"10.1002\/ADTP.202000033"}],"container-title":["Biophysical Reviews"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12551-025-01317-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12551-025-01317-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12551-025-01317-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,24]],"date-time":"2025-07-24T13:54:38Z","timestamp":1753365278000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12551-025-01317-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,24]]},"references-count":145,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025,6]]}},"alternative-id":["1317"],"URL":"https:\/\/doi.org\/10.1007\/s12551-025-01317-7","relation":{},"ISSN":["1867-2450","1867-2469"],"issn-type":[{"value":"1867-2450","type":"print"},{"value":"1867-2469","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,24]]},"assertion":[{"value":"12 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 April 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 April 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}